Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
(Shenzhen iLockey Technology Co.,Ltd) (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BKPU-K5) [Shenzhen iLockey Technology Co.,Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Sophia Hsia (Shenzhen iLockey Technology Co.,Ltd) (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BKPU-K5) [Shenzhen iLockey Technology Co.,Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Sophia Hsia
Shenzhen iLockey Technology Co.,Ltd Model Difference Data:September 2, 2024 Product description: Electronic Lock Model name: K5, K3, K7, K8, K9 Trade Name: iLockey FCC ID: 2BKPU-K5 All the model are the same circuit and RF module, only different for model name. Regards Sincerely Client’s signature : Client’s name / title : Sophia Hsia(Sales manager) Contact information / address:2009 Shuipan Building, No 3193 Binghe Avenue, Futian District, Shenzhen City, Guangdong, China
Shenzhen iLockey Technology Co.,Ltd (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Electronic Lock / K5, K3, K7, K8, K9 / FCC ID: 2BKPU-K5) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Sophia Hsia Title: Sales manager
Shenzhen iLockey Technology Co.,Ltd (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Sophia Hsia Title: Sales manager
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: K5 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
FCC ID LABEL: Label Location: FCC ID: 2BKPU-K5 Model No.: K5 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2BKPU-K5 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result BLE 1M GFSK& MCH -4±1 -3 0.5012 1.2274 (0.89dBi) 0.0001 1 Pass BLE 2M GFSK& MCH -4±1 -3 0.5012 1.2274 (0.89dBi) 0.0001 1 Pass
Antenna test report Manufacturer: Zhongshan Smartek Security Technology Co., LTD. Manufacturer address: 2F, Building B, No.8 Baocheng Rd.Baofeng, Xiaolan Town, Zhongshan City, Guangdong, China OTA-800 Brand:ETS Frequency range:370MHz-8.5GHz Function: passive, active test; G network, C network, 2G/3G/4G, WIFI, BT and other standard TRP, TIS test. Device under test 5071C Brand:安捷伦 Frequency range:9KHz-8.5GHz Function: 2G/3G/4G/BT/WIFI antenna comprehensive passive test. 8960 Brand:安捷伦 Function :292MHz-2700GHz功能: Meet 2G/3G active test. CMW500 Brand:罗德与施瓦茨 Function:70KHz-6GHz Functions: 2G/3G/4G/BT/WIFI/ NB-LOT and other antennas comprehensive active test. 3.Physical picture of antenna assembly position antenna size 电性能指标Electrical Parameter 频率范围(MHz) Frequency Range (MHz)2400~2500 电压驻波比 VSWR≤7.0 输入阻抗(Ω) Input Impedance(Ω)50 增益(dBi) Gain(dBi)0.89 极化形式(°)Polarization(°) vertical 最大功率(W) Max power(W)10 天线类型 Antenna TypeMonopole 工作温度(°C)Working Temperature(°C) -40~+80 4.Electrical performance index 5.Antenna passive data FreqEffiGain (MHz)(%)(dBi) 2400 1.6 0.86 2410 1.360.87 2420 1.77 0.89 2430 1.450.85 2440 1.420.79 2450 1.180.78 2460 1.630.77 2470 1.010.76 2480 10.69 2490 0.730.61 2500 1.420.67 6.Antenna gain/efficiency /3D Apple diagram 7.Antenna pattern
TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Electronic Lock FCC ID: 2BKPU-K5 Trademark: iLockey Model Number: K5, K3, K7, K8, K9 Prepared For: Shenzhen iLockey Technology Co.,Ltd Address: 2009 Shuipan Building, No 3193 Binghe Avenue, Futian District, Shenzhen City, Guangdong, China Manufacturer: Shenzhen iLockey Technology Co.,Ltd Address: 2009 Shuipan Building, No 3193 Binghe Avenue, Futian District, Shenzhen City, Guangdong, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Aug. 12, 2024 Sample tested Date: Aug. 12, 2024 to Aug. 28, 2024 Issue Date: Aug. 28, 2024 Report No.: CTB240823063RFX Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB240826021RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 41 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 3 2. TEST SUMMARY ........................................................................................................................... 4 3. MEASUREMENT UNCERTAINTY ................................................................................................. 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 6 4.1 Product Information .......................................................................................................................... 6 4.2 Test Setup Configuration .................................................................................................................. 6 4.3 Support Equipment........................................................................................................................... 6 4.4 Channel List ..................................................................................................................................... 7 4.5 Test Mode ........................................................................................................................................ 7 4.6 Test Environment ............................................................................................................................. 7 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 8 5.1 Test Facility ...................................................................................................................................... 8 5.2 Test Instrument Used ....................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 11 6.1 Block Diagram Of Test Setup ......................................................................................................... 11 6.2 Limit ................................................................................................................................................ 11 6.3 Test procedure ............................................................................................................................... 11 6.4 Test Result ..................................................................................................................................... 13 7. RADIATED SPURIOUS EMISSION ............................................................................................. 15 7.1 Block Diagram Of Test Setup ......................................................................................................... 15 7.2 Limit ................................................................................................................................................ 15 7.3 Test procedure ............................................................................................................................... 16 7.4 Test Result ..................................................................................................................................... 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 24 8.1 Block Diagram Of Test Setup ......................................................................................................... 24 8.2 Limit ................................................................................................................................................ 24 8.3 Test procedure ............................................................................................................................... 24 8.4 Test Result ..................................................................................................................................... 25 9. COUDUCTED OUTPUT POWER ................................................................................................. 29 9.1 Block Diagram Of Test Setup .....................................................…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: K5 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions
2009 Shuipan Building, No 3193 Binghe Avenue, Futi · Shenzhen City, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 370.00 µW |