2BKQVSHG2501-2Smart Grips

Qudong Future (Shenzhen) Technology Co., Ltd.
Smart Grips - FCC ID 2BKQVSHG2501-2 - Qudong Future (Shenzhen) Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 08, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Grips
Frequency Range
2402.00000000 - 2480.00000000
Company
Qudong Future (Shenzhen) Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

S1SeriesSmartHomeGym UserManual WELCOME TO AEKE Individualcodenumber:91440300MA5HDDFB3Q ThankyouforchoosingtheS1SeriesSmartHomeGym. Beforeusingtheproduct,pleasereadtheproduct informationandprecautionsprovidedinthismanual Howtogetsupport? Weareheretohelpwheneveryouneedus.Youcan contactusinthefollowingways: WEBSITE:www.aeke.com EMAIL:[email protected] DISCLAIMER QudongFuture(Shenzhen)TechnologyCo.,Ltd.,hereinafterreferredtoas "theCompany,"andtheS1SeriesSmartHomeGymanditsrelated accessories,hereinafterreferredtoas"theProduct." Toprotectyourlegalrights,pleasecarefullyreadthismanualandits disclaimerbeforeusingtheProduct.YouarerequiredtousetheProduct strictlyinaccordancewiththeinstructionsprovidedherein.Byactivating andusingtheProduct,youaredeemedtohaveread,understood,acknowl- edged,andacceptedalltermsandconditionsofthismanualanditsdisclaim- er.Usersundertaketoberesponsiblefortheirownactionsandallconse- quencesarisingtherefrom.UsersagreetousetheProductsolelyforlegiti- matepurposesandtocomplywithanycurrentorfuturepoliciesorguide- linesestablishedbytheCompany. DuringtheuseandmaintenanceoftheProduct,youmuststrictlyadhereto andfollowallrequirementsoutlinedinthismanual,includingbutnotlimited toitsinstructions.TheCompanyshallnotbeliableforanypersonalinjury, accidents,propertydamage,legaldisputes,orotheradverseeventsresult- inginconflictsofinterestcausedbyfailuretofollowtheseinstructionsor duetounforeseeablecircumstancesbeyondourcontrol.TheCompanyshall notbearanyresponsibilityforanyactionsarisingdirectlyorindirectlyfrom theuseoftheProductthatviolateapplicablelawsorregulations.Usersshall assumefullresponsibilityandliabilityforsuchincidentsandlosses.Ifany operationseemsoverlycomplexorunsafe,werecommendcontactingour supportteamforprofessionalguidance. Thisdeviceis"forconsumeruseonly."Theownershallprovideuserswithall necessarywarningsandinstructions. CONTENTS 01 02 03 04 05 SafetyInformation 01 ProductOverview ProductDiagram06 PackageContents09 ProductSpecifications11 InstallationandPlacement Pre-Unpacking12 Unpacking13 Moving14 Installing15 Placement16 ProductOperation PowerOn/Off18 Standby/Reset/TurningOff18 BluetoothConnection19 Wi-FiSetup20 AccessoriesOverview SmartGripsView21 Cross-bar&ResistanceController25 TricepsRopeView27 Smart8Electrodescale28 HeartRateArmband28 Cameracover31 06 07 08 09 10 Troubleshooting SNLookup ResistanceCableCanNotRetract TechnicalSupport MaintenanceandCare DeviceCleaning ScreenMaintenance PowerMaintenance ResistanceCableReplacement Prohibitions Precautions Permanentmarker Warrantyand After-SalesService Overview LimitedProductWarranty FreeRepairConditions Exclusions HowtoGetService Returnand Refundpolicy FCC&CEStatement 32 32 33 34 34 34 34 34 35 36 37 37 38 38 38 39 41 SAFETYINFORMATION 01 01 01SAFETYINFORMATION TheS1SeriesSmartHomeGymisadigitalstrengthtrainingsystem designedexclusivelyforindooruse,compliantwithCLASSHequipment certification(ISO20957).Itisnotintendedforhigh-precisionapplications butfeaturesaheavyloadcapacityandmotorthatgeneratessubstantial resistance(2.5–50kgperside).Improperuseofthisdeviceoritsaccessories mayresultinequipmentdamageorpersonalinjury. TheS1SeriesSmartHomeGymmodelsSHG2501-1,SHG2601-1, SHG2701-1,SHG2801-1,andSHG2901-1.Thesemodelsdifferonlyincolor andmarketdistributionregions;allotherspecificationsremainidentical.The operationalprinciples,intendeduserdemographics,andexercisemodesof theseproductsarefullyconsistent. •Beforeusingtheproduct,pleaseinspectitanditsaccessoriesforanydamageIfany abnormalitiesaredetected,discontinueuseimmediatelyandcontactofficialcustomer service •Donotattempttorepairtheproductyourself,anddisassemblyisstrictlyprohibited •Donotremoveordamagethewarninglabelsorsignageontheproductoritsaccessories Iflabelsorsignagearefoundtobedamaged,illegible,orremoved,pleasecontactofficial customerservice MaximumUserWeight≤150kg AdjustableArmTrainingLoad:≤150kg UsageCategoryPrecision:HC Thedeviceanditspedalstrainingload≥150kg. TheMotorSubstantialResistance(2.5-50kgperside) MotorGearIntervals:Precise0.5kgAdjustment Donotexceedthedevice'ssetcapacity Beforeusingtheproduct,pleasereadtheproductinformationandprecautionsprovidedin thismanual.AdequatewarningsfollowingtheguidelinesofSpecificationF1749andF2276. Allthewarninginformationmarkedontheproductisalsopresentedintheusermanual. Donothangonarms. Stayclearduringadjustment.Ensurethefootboardissecurelylockedbeforeuse Keepchildrenaway.Anobservermustbepresentwhenusingthedevice. Forconsumeruseonly Standards:ENISO20957-1、ENISO20957-2 thatusingthemachineforsupportduringstretchingorallowingresistancestraps,ropesor othermeanstobeattachedtoitmayresultinseriousinjury. XXXXXXXXX 02 01SAFETYINFORMATION InstallationSafety GROUNDREQUIREDORIGINAL3-PRONGPOWERKEEPAREACLEAN •InstalltheProductstrictlyaccordingtothisusermanual. •Usetheoriginal3-prongpowercordandconnectonlytoaproperlygroundedoutlet(⏚). •PlacetheProductonastable,levelhardsurface(e.g.,marble,hardwood,ortile).Donot placeitonsoftsurfacessuchascarpetorfelt. •KeeptheareaaroundtheProductclearofclutter,heavyobjects,anditemsthatcouldfallto preventinstabilityordamagetothemirroredscreen. ElectricalSafety NOFLAMMABLESNODAMPNOOPENFLAME •Theproductisnotwaterproofandmustbeusedinadry,well-ventilatedenvironmentDonot splashwateronit,andpreventwaterfromenteringthepowerport,mirroredscreen,or internalgapsbetweentheframetoavoidshortcircuitsorotherdamage •Duringsevereweatherconditionssuchasthunderstorms,unplugthepowercordto preventdamagetotheproduct •useonlypoweroutletscertifiedforsafetybynationalstandards,andavoidoverloading electricalcircuits 03 01SAFETYINFORMATION •usetheoriginalpowercordprovidedwiththeproductDonotusepowerequipmentfrom otherbrandstopowertheproduct •keeptheproductawayfromhighelectromagneticinterferenceenvironments,suchas mobilephonebasestationsorhigh-powertransmissiondevices,duringuse •Ifyounoticeunusualnoises,odors,smoke,oranyotherirregularitiesduringuse,immedi- atelyturnoffthepower,unplugthecord,andcontactofficialcustomerservice OperationalSafety •Avoidst…

Text truncated - open the document above for the full version.

Attestation Statements

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:April7,2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BKQVSHG2501-2 QudongFuture(Shenzhen)TechnologyCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§ 1.50002ofreferencechapter,asanentityproducing“covered”communicationequipment.The equipmentforwhichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideo surveillanceequipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibited fromreceivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:ZhangpingHe Title:Manager Address:1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China Tel.:0755-23573094 Email:[email protected]

Attestation Statements

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:April7,2026 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2BKQVSHG2501-2] ProductName:[SmartGrips] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:ZhangpingHe Title:Manager Address:1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China Tel.:0755-23573094 Email:[email protected] QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) compliance ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck SBOM(SoftwareBillofMaterials)[ForDeviceisnotInherentcompliance] SectionComponentNameVersionSupplier 1 2 3

Attestation Statements

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Apr.29,26 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:[2BKQVSHG2501-2] [QudongFuture(Shenzhen)TechnologyCo.,Ltd.](“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,[WeFaSelectionTradeTechnologyCo.,LTD](“theagent”)isour designatedU.S.agentforserviceofprocessfortheabovereferenceFCCID.Theapplicantaccepts tomaintainanagentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereither thegranteehaspermanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater.Theapplicantfurtheracknowledgesitisour responsibilitytoinformtheFCCwhenevertheagentinformationchanges. [WeFaSelectionTradeTechnologyCo.,LTD]("theagent)understanditistheagent'sobligationto acceptserviceofprocessintheUnitedStatesformattersrelatedtotheapplicableequipment,and atthephysicalU.S.addressandemailaddress. DesignatedU.S.Agent CompanyName:WeFaSelectionTradeTechnologyCo.,LTD FRN:0033767856 Address: 30N.GOULDST.STENSHERIDAN WY,SHERIDAN,WY82801,UnitedStates Signature: Tel:3023719847Email:[email protected] Applicant CompanyName: QudongFuture(Shenzhen)TechnologyCo.,Ltd. FRN :0035896968 Address: 1001,WanhaiBuilding,No.1031,Gongye5th Road,Nanshan,Shenzhen,China Signature: ContactPerson:ZhangpingHe Tel:0755-23573094Email:[email protected]

Cover Letter(s)

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) (April7,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BKQVSHG2501-2 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription (Etc.) Sincerely, (Signature) Title:Manager Address:1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China Tel.:0755-23573094 Email:[email protected]

Cover Letter(s)

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) (April14,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BKQVSHG2501-2 I,theundersigned,herebyauthorize(ShenzhenHaiyunStandardTechnicalCO.,Ltd.)toactonourbehalf inallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenHaiyunStandardTechnicalCO.,Ltd.)shallhavethesameeffectasour ownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification, asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(QudongFuture (Shenzhen)TechnologyCo.,Ltd.). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) (FullnameofcontactpersonlistedonFCC’swebsite)ZhangpingHe (Title)Manager Tel.:0755-23573094 Fax:/ Email:[email protected]

Cover Letter(s)

QudongFuture(Shenzhen)TechnologyCo.,Ltd. (1001,WanhaiBuilding,No.1031,Gongye5thRoad,Nanshan,Shenzhen,China) APPLICANTCOMPANYLETTERHEAD We(QudongFuture(Shenzhen)TechnologyCo.,Ltd.)Producemodel SHG2501-2,andseriesmodels:SHG2601-2、SHG2701-2、HG2801-2、 SHG2901-2,theyaresameinsafetykeyparts,circuitdiagramprinciple, structure,voltage,current,etc.,onlytheproductnameandappearance aredifferent. Company:QudongFuture(Shenzhen)TechnologyCo.,Ltd. Date:2026-4-7 Signature:

External Photos

FCCID:2BKQVSHG2501-2 Page1/3 EUTEXTERNALPHOTO EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page2/3 EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page3/3 EUTPhoto EUTPhoto

ID Label/Location Info

Lableand location

Internal Photos

FCCID:2BKQVSHG2501-2 Page1/5 EUTINTERNALPHOTOS EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page2/5 EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page3/5 EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page4/5 EUTPhoto EUTPhoto FCCID:2BKQVSHG2501-2 Page5/5 EUTPhoto

RF Exposure Info

HY-FCC 2.1091 Ver.1.1 Page 1 of 5 Report No.: RF260127032-02-004 FCC RF EXPOSURE REPORT FCC ID: 2BKQVSHG2501-2 T est Report No...........: RF260127032-02-004 Product(s) Name.........: Smart Grips Model(s)....................: SHG2501-2, SHG2601-2, SHG2701-2 , HG2801-2, SHG2901-2 Trade Mark................: AEKE Applicant...................: Qudong Future (Shenzhen) Technology Co., Ltd. Address....................: 1001, Wanhai Building, No.1031,Gongye 5th Road, Nanshan, Shenzhen, China Receipt Date..............: 2026.01.27 Test Date...................: 2026.01.19 ~ 2026.03.10 Issued Date................: 2026.03.16 Standards..................: CFR47 FCC Part 1: Section 1.1310; CFR47 FCC Part 2: Section 2.1091 FCC KDB Publication 447498 D01v06 Testing Laboratory......: Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By: Checked By: Approved By: Jason Huang Black Ding Tim Zhang HY-FCC 2.1091 Ver.1.1 Page 2 of 5 Report No.: RF260127032-02-004 History of this test report Original Report Issue Date: 2026.03.16 ● No additional attachment ○ Additional attachments were issued following record Attachment No. Issue Date Description HY-FCC 2.1091 Ver.1.1 Page 3 of 5 Report No.: RF260127032-02-004 1. TEST FACILITY Company: Shenzhen Haiyun Standard Technical Co., Ltd. Address: No. 110-113, 115, 116, Block B, Jinyuan Business Building, Bao'an District, Shenzhen, China CNAS Registration Number: CNAS L18252 CAB identifier: CN0145 A2LA Certificate Number: 6823.01 2. MPE CALCULATION METHOD  Product Classification This device defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at 20 cm is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons.  Radio Frequency Exposure Limit Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm²) 300-1,500 -- -- f/1500 1,500-100,000 -- -- 1.0  Radio Frequency Exposure Calculation Formula HY-FCC 2.1091 Ver.1.1 Page 4 of 5 Report No.: RF260127032-02-004  Table for Filed Antenna For BLE Ant. Brand Antenna Type Connector Gain (dBi) 1 N/A PCB N/A -0.06 3. TEST RESULTS Worst case as below Operating Mode Freq. Maximum conducted output power Directional Antenna Gain Calculated maximum EIRP MPE Limit MPE Value (MHz) (dBm) (dBi) (dBm) (mW) (mW/cm 2 ) BLE 2402-2480 -3.63 -0.06 -3.69 0.43 1 0.0001 Note: Note: 1. The calculated distance is 20 cm.  Conclusion Result: Complies HY-FCC 2.1091 Ver.1.1 Page 5 of 5 Report No.: RF260127032-02-004 Statement 1. The report is invalid without the official seal or special seal of Shenzhen Haiyun Standard Technical Co., Ltd. (hereinafter referred to as the unit). 2. The report is invalid without the signature of the approver. 3. The report is invalid if altered arbitrarily. 4. The report shall not be partially copied without the written approval of the unit. 5. The reported test results are only valid for the tested samples. 6. If there is any objection to the test report, it shall be submitted to the test unit within 15 days from the date of receiving the report, and the overdue shall not be accepted. Shenzhen Haiyun Standard Technical Co., Ltd. Address: Room 110, 111, 112, 113, 115, 116, Block B, Jinyuan Business Building, No. 302, Xixiang Avenue, Labor Community, Xixiang Street, Baoan District, Shenzhen, China (END OF REPORT)

Test Report

Latestve- rsion V1.4 Weilintong(Shanghai)CommunicationTechnologyCo.,Ltd. COPYRIGHT©2011-2023 WLT8016AntennaSpecification Wi-linktech www.wi-linktech.com 24/08/2023 1 1.Summary ThisantennaspecificationdocumentdescribestheRFperformanceoftheWLT8016module's onboardantenna,ensuringaVSWRbelow2at2.4GHzISMfrequencywhenconnectedtoa50-ohm source.Italsodetailstheantenna'sgainpatternacrossdifferentdirections,alongwithitsefficiencyand gainvaluesforvariousfrequencybands. Figure1-1:WLT8016Module WLT8016moduleantennasize WLT8016AntennaInformation Wi-linktech 3.Returnloss、 VSW R VSWR Returnloss V SWR 2.TestingFacility Wi-linktech 4.DirectionandGainDiagram Etheta[Unit:dBi] www.wi-linktech.com 2 24/08/2023 Wi-linktech Ephi[Unit:dBi] www.wi-linktech.co gain: -0.72 Gain:-1.90dBi dBi Gain:-0.06dBi m 4 24/08/2023 Wi-linktech 5.AntennaGainTable Frequency/MHzEfficiency/%Gain/dBi 240022.29-1.90 241024.61-1.52 242026.72-1.15 243028.62-0.77 244027.97-0.72 245030.65-0.17 246030.04-0.16 247028.77-0.17 248028.70-0.06 249026.38-0.34 250025.77-0.40 www.wi-linktech.com4 24/08/2023

Test Report

HY-FCC part 15C-BLE Ver.1.1 Page 1 of 48 Report No.: RF260127032-02-003 RF TEST REPORT FCC ID: 2BKQVSHG2501-2 Test Report No...........:RF260127032-02-003 Product(s) Name.........: Smart Grips Model(s)....................: SHG2501-2, SHG2601-2, SHG2701-2, HG2801-2, SHG2901-2 Trade Mark................:AEKE Applicant...................:Qudong Future (Shenzhen) Technology Co., Ltd. Address.....................:1001, Wanhai Building, No.1031,Gongye 5th Road, Nanshan, Shenzhen, China Receipt Date..............: 2026.01.18 Test Date...................: 2026.01.19 ~ 2026.03.10 Issued Date................: 2026.03.16 Standards..................:47 CFR FCC Part 15, Subpart C(Section 15.247) ANSI C63.10:2020+Cor 1-2023 Testing Laboratory......:Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By:Checked By:Approved By: Jason HuangBlack DingTim Zhang HY-FCC part 15C-BLE Ver.1.1 Page 2 of 48 Report No.: RF260127032-02-003 Table of Contents REPORT ISSUED HISTORY4 1 . SUMMARY OF TEST RESULTS5 1.1 TEST FACILITY6 1.2 MEASUREMENT UNCERTAINTY6 1.3 TEST ENVIRONMENT CONDITIONS6 2 . GENERAL INFORMATION7 2.1 GENERAL DESCRIPTION OF EUT7 2.2 DESCRIPTION OF TEST MODES8 2.3 PARAMETERS OF TEST SOFTWARE9 2.4 SUPPORT UNITS9 3 . AC POWER LINE CONDUCTED EMISSIONS10 3.1 LIMIT10 3.2 TEST PROCEDURE10 3.3 DEVIATION FROM TEST STANDARD10 3.4 TEST SETUP11 3.5 EUT OPERATING CONDITIONS11 3.6 TEST RESULTS11 4 . RADIATED EMISSIONS12 4.1 LIMIT12 4.2 TEST PROCEDURE13 4.3 DEVIATION FROM TEST STANDARD14 4.4 TEST SETUP14 4.5 EUT OPERATING CONDITIONS15 4.6 TEST RESULT - 9 KHZ TO 30 MHZ15 4.7 TEST RESULT - 30 MHZ TO 1000 MHZ15 4.8 TEST RESULT - ABOVE 1000 MHZ15 5 . BANDWIDTH16 5.1 LIMIT16 5.2 TEST PROCEDURE16 5.3 DEVIATION FROM STANDARD16 5.4 TEST SETUP16 5.5 EUT OPERATION CONDITIONS16 5.6 TEST RESULTS16 6 . MAXIMUM OUTPUT POWER17 6.1 LIMIT17 HY-FCC part 15C-BLE Ver.1.1 Page 3 of 48 Report No.: RF260127032-02-003 6.2 TEST PROCEDURE17 6.3 DEVIATION FROM STANDARD17 6.4 TEST SETUP17 6.5 EUT OPERATION CONDITIONS17 6.6 TEST RESULTS17 7 . CONDUCTED SPURIOUS EMISSION18 7.1 LIMIT18 7.2 TEST PROCEDURE18 7.3 DEVIATION FROM STANDARD18 7.4 TEST SETUP18 7.5 EUT OPERATION CONDITIONS18 7.6 TEST RESULTS18 8 . POWER SPECTRAL DENSITY19 8.1 LIMIT19 8.2 TEST PROCEDURE19 8.3 DEVIATION FROM STANDARD19 8.4 TEST SETUP19 8.5 EUT OPERATION CONDITIONS19 8.6 TEST RESULTS19 9 . MEASUREMENT INSTRUMENTS LIST20 10 . ANTENNA REQUIREMENT21 APPENDIX A- RADIATED EMISSION - 9 KHZ TO 30 MHZ22 APPENDIX B- RADIATED EMISSION - 30 MHZ TO 1000 MHZ23 APPENDIX C- RADIATED EMISSION - ABOVE 1000 MHZ26 APPENDIX D BANDWIDTH27 APPENDIX E- MAXIMUM OUTPUT POWER34 APPENDIX F- CONDUCTED SPURIOUS EMISSION38 APPENDIX G POWER SPECTRAL DENSITY44 HY-FCC part 15C-BLE Ver.1.1 Page 4 of 48 Report No.: RF260127032-02-003 REPORT ISSUED HISTORY Original Report Issue Date: 2026.03.16 ● No additional attachment ○ Additional attachments were issued following record Attachment No.Issue DateDescription HY-FCC part 15C-BLE Ver.1.1 Page 5 of 48 Report No.: RF260127032-02-003 1.. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC CFR Title 47, Part 15, Subpart C Standard(s) SectionTest ItemTest ResultJudgmentRemark 15.207 AC Power Line Conducted Emissions ------------ N/A 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX A APPENDIX B APPENDIX C PASS ------ 15.247(a)(2) BandwidthAPPENDIX DPASS ------ 15.247(b)(3) Maximum Output PowerAPPENDIX EPASS ------ 15.247(d) Conducted Spurious Emission APPENDIX FPASS ------ 15.247(e) Power Spectral DensityAPPENDIX GPASS ------ 15.203 Antenna Requirement------PASS Note(2) Note: (1) “N/A” denotes test is not applicable to this device. (2) The device what use a permanently attached antenna were considered sufficient to comply with the provisions of 15.203. HY-FCC part 15C-BLE Ver.1.1 Page 6 of 48 Report No.: RF260127032-02-003 1.1. TEST FACILITY Company: Shenzhen Haiyun Standard Technical Co., Ltd. Address: No. 110-113, 115, 116, Block B, Jinyuan Business Building, Bao'an District, Shenzhen, China CNAS Registration Number: CNAS L18252 CAB identifierCN0145 A2LA Certificate Number6823.01 1.2. MEASUREMENT UNCERTAINTY ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)) Uncertainty ParameterUncertainty Occupied Channel Bandwidth±102kHz RF power conducted±0.243dB Power Spectral Density ±0.743dB Conducted Spurious Emission±1.328dB Conducted emission(9kHz~30MHz) AC main±2.68dB Radiated emission(9kHz~30MHz)±3.50dB Radiated emission (30MHz~1GHz)±4.20dB Radiated emission (1GHz~18GHz)±5.10dB Radiated emission (18GHz~40GHz)±5.26dB Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into account to declare the compliance or non-compliance to the specification. 1.3. TEST ENVIRONMENT CONDITIONS Test ItemTemperatureHumidityTest VoltageTested By Radiated Emissions-9 kHz to 30 MHz24.8°C54%DC 3.7VKeith Huang Radiated Emissions-30 MHz to 1000 MHz24.8°C54%DC 3.7VKeith Huang Radiated Emissions-Above 1000 MHz24.8°C54%DC 3.7VKeith Huang Bandwidth23.4°C46%DC 3.7VLemon He Maximum Output Power 23.4°C46%DC 3.7VLemon He Conducted Spurious Emission23.4°C46%DC 3.7VLemon He Power Spectral Density23.4°C46%DC 3.7VLemon He HY-FCC part 15C-BLE Ver.1.1 Page 7 of 48 Report No.: RF260127032-02-003 2.. GENERAL INFORMATION 2.1. GENERAL DESCRIPTION OF EUT Sample No.POC260127032-S002 Product nameSmart Grips Model nameSHG2501-2, SHG2601-2, SHG2701-2, HG2801-2, SHG2901-2 Test modelSHG2501-2 Model differenceOnly the model name and appearance are different. Trade MarkAEKE Power supplyDC 3 V from adapter Operate temperature 0°C-45°C Operation Frequency2402 MHz ~ 2480 MHz Modulation TypeGFSK Bit Rate of Transmitter1Mbps Max. Output Power-3.63dBm (0.0004W) Antenna gain-0.06dBi Antenna typePCB Antenna Note: 1. For a more detailed features desc…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BKQVSHG2501-2 Page 1 / 1 APPENDIX1PHOTOSOFTESTSETUP RadiatedSpuriousEmission,Below1GHz RadiatedSpuriousEmission,Above1GHz

Contact Information

Applicant

Zhangping He
[email protected]Fax: 0755-23573094

Technical Contact

WeFa Selection Trade Technology Co., LTDJoson Ye
[email protected]

30 N. GOULD ST. STE N · SHERIDAN, Wyoming, 82801 · United States

Test Firm

Shenzhen Haiyun Standard Technical CO., Ltd.Lin Chen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz434.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.