Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Attestation Statements (September 2, 2024) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2BKQX-P7 ) (SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD), the undersigned, hereby authorize (NEWENERGYER LIMITED) to act as our designated U.S. agent for service of process, (SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (NEWENERGYER LIMITED) accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD Contact Name: BENDY QIU Address: 202BUILDING 9 BLOCK B XUEZIWEI INDUSTRIAL PARK SHAJING STREET BAOAN DISTRICT SHENZHEN China Telephone No: 13538214502 Email: [email protected] FRN: 0035896976 Signature [BENDY QIU] U.S. Agent Information: Company Name: NEWENERGYER LIMITED Address: 1818 S Patton Ct, Denver, CO, 80219 Contact Name: CHUN LIU Telephone No: 213 289 5042 Email: [email protected] FRN: 0034665885 Signature [CHUN LIU]
(SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD) (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BKQX-P7) [SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) BENDY QIU (SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD) (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BKQX-P7) [SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) BENDY QIU
SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD Model Difference Data:September 2, 2024 Product description: Kids camera Model name: P7, P0, P1, P2, P3, P4, P5, P6, P8, P9, P10, P11, P12, P13, P15 Trade Name: N/A FCC ID: 2BKQX-P7 All models are the same circuit and RF module, only the appearance is different. Regards Sincerely Client’s signature : Client’s name / title : BENDY QIU(MANAGER) Contact information / address:202BUILDING 9 BLOCK B XUEZIWEI INDUSTRIAL PARK SHAJING STREET BAOAN DISTRICT SHENZHEN China
SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Kids camera / P7, P0, P1, P2, P3, P4, P5, P6, P8, P9, P10, P11, P12, P13, P15 / FCC ID: 2BKQX-P7) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: BENDY QIU Title: MANAGER
SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD (September 2, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: BENDY QIU Title: MANAGER
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: P7 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4
FCC ID LABEL: Label Location: FCC ID: 2BKQX-P7 Model No.: P7
Anenna describe: 1 Antenna describe Al Antenna gain0dBi Freuencrange24GHZ2480GHZ Antenna platePCB antenna Make name/model name LX-D02 Location of mearement(company name) Shenzhen SVAKOM Technology Co.,Ltd Frequency range2.4GHZ-2.480GHZ Connector typedirect 2External view drawing: picture of antenna 3 Antenna Radiation Parrerm Radiation [email protected] Phi 04590135180235270315 Gi -0.1 -0.3 -0.8 -0.5 -0.2 -0.6 -0.8 -0.5 Gain Phi Total Average Gain:-0.275 dbi Radiaton [email protected] Phi 04590135180235270315 Gain 0-0.1 -0.3 -0.6 -0.1 -0.2 -0.6 -0.4 Total Average Gain:-0.237 dbi Radiation [email protected] Phi 04590135180235270315 Gain 0-0.1 -0.2 -0.50-0.3 -0.6 -0.2 Gain Rediation Pattern PHI=0 PHI=90 THETA=180 Manufacturer: SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD Address: 202BUILDING 9 BLOCK B XUEZIWEI INDUSTRIAL PARK SHAJING STREET BAOAN DISTRICT SHENZHEN China
TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Kids camera FCC ID: 2BKQX-P7 Trademark: N/A Model Number: P7, P0, P1, P2, P3, P4, P5, P6, P8, P9, P10, P11, P12, P13, P15 Prepared For: SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD Address: 202BUILDING 9 BLOCK B XUEZIWEI INDUSTRIAL PARK SHAJING STREET BAOAN DISTRICT SHENZHEN China Manufacturer: SHENZHEN BINBINYOULI TECHNOLOGY CO., LTD Address: 202BUILDING 9 BLOCK B XUEZIWEI INDUSTRIAL PARK SHAJING STREET BAOAN DISTRICT SHENZHEN China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Aug. 21, 2024 Sample tested Date: Aug. 21, 2024 to Aug. 26, 2024 Issue Date: Aug. 26, 2024 Report No.: CTB240826021RFX Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB240826021RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 35 TABLE OF CONTENT Test Report Declaration Page 1. VERSION .......................................................................................................................................... 3 2. TEST SUMMARY ............................................................................................................................. 4 3. MEASUREMENT UNCERTAINTY ................................................................................................... 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................. 6 4.1 Product Information ............................................................................................................................ 6 4.2 Test Setup Configuration ................................................................................................................... 6 4.3 Support Equipment ............................................................................................................................ 6 4.4 Channel List ....................................................................................................................................... 7 4.5 Test Mode .......................................................................................................................................... 7 4.6 Test Environment ............................................................................................................................... 7 5. TEST FACILITY AND TEST INSTRUMENT USED ......................................................................... 8 5.1 Test Facility ........................................................................................................................................ 8 5.2 Test Instrument Used ......................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION .................................................................................. 11 6.1 Block Diagram Of Test Setup ........................................................................................................... 11 6.2 Limit .................................................................................................................................................. 11 6.3 Test procedure ................................................................................................................................. 11 6.4 Test Result ....................................................................................................................................... 13 7. RADIATED SPURIOUS EMISSION ............................................................................................... 15 7.1 Block Diagram Of Test Setup ........................................................................................................... 15 7.2 Limit .................................................................................................................................................. 15 7.3 Test procedure ................................................................................................................................. 16 7.4 Test Result ....................................................................................................................................... 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ................................................ 24 8.1 Block Diagram Of Test Setup ........................................................................................................... 24 8.2 Limit .................................................................................................................................................. 24 8.3 Test procedure ................................................................................................................................. 24 8.4 Test Result ....................................................................................................................................... 25 9. COUDUCTED OUTPUT POWER ............................................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: P7 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions
202BUILDING 9 BLOCK B XUEZIWEI · SHENZHEN · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.09 mW |

Kids camera
Equipment Class
DTS - Digital Transmission System