Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCCStatement Thisequipmenthasbeentestedandfoundtocomplywiththe limitsforaClassBdigitaldevice,pursuanttopart15oftheFCC Rules.Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferenceinaresidentialinstallation.This equipmentgenerates,usesandcanradiateradiofrequencyenergy and,ifnotinstalledandusedinaccordancewiththeinstructions, maycauseharmfulinterferencetoradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurin aparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbe determinedbyturningtheequipmentoffandon,theuseris encouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfrom thattowhichthereceiverisconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenot explicitlyapprovedbymanufacturercouldvoidyourauthorityto operatethisequipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationis subjecttothefollowingtwoconditions:(1)Thisdevicemaynot causeharmfulinterference,and(2)thisdevicemustacceptany interferencereceived,includinginterferencethatmaycause undesiredoperation. RFExposureInformation ThisequipmentcomplieswithFCCradiationexposurelimitsset forthforanuncontrolledenvironment.Thisequipmentshouldbe installedandoperatedwithminimumdistance20cmbetweenthe radiatorandyourbody.
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BKUI-XY-CEI-24W XY-CEI-24W, YB8007/300, XY-CEI-36W, XY-LD-18W, XY-LD-24W, XY-LD-28W, XY-LD-36W, XY-LD-48W, XY-CP-18W, XY-CP-24W, XY-CP-28W, XY-CP-36W We, Applicant Company Name: Zhongshan XUYI Lighting Co., Ltd. Address: 2nd floor, Lefeng 6 Road, Henglan Town, Zhongshan city, Guangdong Province 528400, China Phone: +86-760-22277535 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc.. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-14 Signature Date Name / Title: ZHONG LI / Manager Company: Zhongshan XUYI Lighting Co., Ltd. Address: 2nd floor, Lefeng 6 Road, Henglan Town, Zhongshan city, Guangdong Province 528400, China Phone: +86-760-22277535 Fax: N/A E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BKUI-XY-CEI-24W XY-CEI-24W, YB8007/300, XY-CEI-36W, XY-LD-18W, XY-LD-24W, XY-LD-28W, XY-LD-36W, XY-LD-48W, XY- CP-18W, XY-CP-24W, XY-CP-28W, XY-CP-36W For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-14 Signature Date Name / Title: ZHONG LI / Manager Company: Zhongshan XUYI Lighting Co., Ltd. Address: 2nd floor, Lefeng 6 Road, Henglan Town, Zhongshan city, Guangdong Province 528400, China Phone: +86-760-22277535 Fax: N/A E-Mail: [email protected]
Zhongshan XUYI Lighting Co., Ltd. 2nd floor, Lefeng 6 Road, Henglan Town, Zhongshan city, Guangdong Province 528400, China Date: September 14, 2024 FCC ID: 2BKUI-XY-CEI-24W Model Number: XY-CEI-24W, YB8007/300, XY-CEI-36W, XY-LD-18W, XY-LD-24W, XY-LD-28W, XY-LD-36W, XY-LD-48W, XY-CP-18W, XY-CP-24W, XY-CP-28W, XY-CP-36W To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Zhongshan XUYI Lighting Co., Ltd. hereby declare that our product (LED Ceiling lamp) Model Number: XY-CEI-24W, YB8007/300, XY-CEI-36W, XY-LD-18W, XY-LD-24W, XY-LD-28W, XY-LD-36W, XY-LD-48W, XY-CP-18W, XY-CP-24W, XY-CP-28W, XY-CP-36W board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: ZHONG LI / Manager Company: Zhongshan XUYI Lighting Co., Ltd. Address: 2nd floor, Lefeng 6 Road, Henglan Town, Zhongshan city, Guangdong Province 528400, China Phone: +86-760-22277535 Fax: N/A E-Mail: [email protected]
Page1of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7
Page1of1FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L6.0cmx5.0cm) LabelLocation LEDCeilinglamp Model:XY-CEI-24W FCCID:2BKUI-XY-CEI-24W
Page1of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Antenna Page6of6FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11
Page1of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation EUTLEDCeilinglamp TestModelXY-CEI-24W AdditionalModelNo.YB8007/300,XY-CEI-36W,XY-LD-18W,XY-LD-24W,XY-LD-28W, XY-LD-36W,XY-LD-48W,XY-CP-18W,XY-CP-24W,XY-CP-28W, XY-CP-36W ModelDeclarationPCBboard,structureandinternalofthesemodel(s)arethesame, Sonoadditionalmodelsweretested PowerSupply Input:AC100-240V,50/60Hz,24W HardwareVersion / SoftwareVersion / FrequencyRange5800MHz(±75MHz) ChannelNumber1channel ModulationTypeGFSK AntennaDescriptionInternalAntenna,2.3dBi(Max.) Exposurecategory Generalpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice Page2of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationmethodandLimit SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. 3.Limit 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:portabledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequency band Maximum antennagain Notes InternalInternalAntenna5800MHz2.3dBi5.8GAntenna 6.ConductedPower TestProcedure TXfrequencyrange:5800MHz(Worstresult) Devicecategory:MobileDevice(Distance:20cm) Max.FieldStrength:91.78dBuV/m@3m EIRP=E-104.7+20logD=91.78-104.7+20log3=-3.38dBm MaximumConductedOutputPower:-3.38dBm Tune-up:-3±1 7.EvaluationResults AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. Modulation Type Outputpower AntennaGain (dBi) Antenna Gain(linear) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK-2.00.63102.31.69820.00021.0000 Remark: 1.Outputpowerincludingtuneuptolerance; 2.Outputpowerwasadjusttodutycycleat100%ifmeasureddutycyclelessthan98%; 3.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer. 8.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRFExposureand SARExclusionThresholdperKDB447498v06. Page4of4FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity .......................THEENDOFREPORT.........................
第 1 页共 2 页 AntennaTestReportData 1.ANTSPECSummary: a)ModelName:5.8GANT b)AntennaType:Patch: c)WorkingFrequency:5.8GHZ d)AntennaGain:2.3dbi e)Impedance:50ohm f)OverallDimentions:12.65mm*12.65mm g)Manufacture:ROHOSENPhotoelectricTechnologyCo.,Ltd. 2 . An t e nn a Ph o t o a n d Dim e n t i o n s : T o p v i ew Address: Room 308, No. 2, Lane 168, Taihong Road, Minhang District, Shanghai, China 第 2 页共 2 页 3.3DAntennaGain: 4.2DAntennaGain:
Page1of33FCCID:2BKUI-XY-CEI-24WReportNo.:LCSA09034060EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ZhongshanXUYILightingCo.,Ltd. LEDCeilinglamp TestModel:XY-CEI-24W AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ZhongshanXUYILightingCo.,Ltd. Address: 2ndfloor,Lefeng6Road,HenglanTown,Zhongshancity, GuangdongProvincee,CN Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September05,2024 Numberoftestedsamples:2 SampleNo.:A240902063-1,A240902063-2 Serialnumber:Prototype DateofTest:September05,2024~September11,2024 DateofReport:September12,2024 Page2of33FCCID:2BKUI-XY-CEI-24WReportNo.:LCSA09034060EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.249) ReportReferenceNo......................:LCSA09034060EA DateofIssue.......................................:September12,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ZhongshanXUYILightingCo.,Ltd. Address................................................: 2ndfloor,Lefeng6Road,HenglanTown,Zhongshancity, GuangdongProvincee,CN TestSpecification Standard..............................................:FCCCFR47PART15C(15.249)/ANSIC63.10:2013 TestReportFormNo.........................:TRF-4-E-189A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:LEDCeilinglamp TradeMark..........................................:N/A TestModel...........................................:XY-CEI-24W Ratings.................................................:PleaseRefertoPage6 Result..................................................: Positive Compiledby:Supervisedby:Approvedby: JokerHu/Administrator CaryLuo/TechniqueprincipalGavinLiang/Manager Page3of33FCCID:2BKUI-XY-CEI-24WReportNo.:LCSA09034060EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA09034060EA September12,2024 Dateofissue TestModel..............................:XY-CEI-24W EUT.........................................:LEDCeilinglamp Applicant...............................:ZhongshanXUYILightingCo.,Ltd. Address..................................: 2ndfloor,Lefeng6Road,HenglanTown,Zhongshancity, GuangdongProvincee,CN Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ZhongshanXUYILightingCo.,Ltd. Address...................................: 2ndfloor,Lefeng6Road,HenglanTown,Zhongshancity, GuangdongProvincee,CN Telephone...............................:/ Fax..........................................:/ Factory...................................:ZhongshanXUYILightingCo.,Ltd. Address...................................: 2ndfloor,Lefeng6Road,HenglanTown,Zhongshancity, GuangdongProvincee,CN Telephone...............................:/ Fax..........................................:/ Page4of33FCCID:2BKUI-XY-CEI-24WReportNo.:LCSA09034060EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000September12,2024InitialIssue--- Page5of33FCCID:2BKUI-XY-CEI-24WReportNo.:LCSA09034060EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION......................................................................................................6 1.1DescriptionofDevice(EUT).............................................................................................................6 1.2.SupportEquipmentList....................................................................................................................7 1.3.ExternalI/O......................................................................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2BKUI-XY-CEI-24W ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.72 GHz - 5.88 GHz | - |