FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou Wenzhong Technology Co., Ltd/
  3. 2BKXNYK433G40504

2BKXNYK433G40504remote control

Hangzhou Wenzhong Technology Co., Ltd
remote control - FCC ID 2BKXNYK433G40504 - Hangzhou Wenzhong Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 26, 2024
Application Purpose
Original Equipment
Date of Application
Sep 26, 2024
Equipment Note
remote control
Frequency Range
433.92000000 - 433.92000000
Company
Hangzhou Wenzhong Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 / 2 Operation Guide 一、 Remote control button function: :In standby mode, short press this button to start the treadmill after 3 seconds count down , the default speed is 1.0 km/h. In operation mode , short press this button switch to stop and speed reduce slowly till stop. : To customize workout target ( Ex : Time / Distance/ Calrioes) and count down. :Increase speed by 0.1 km/h :Reduce speed by 0.1 km/h 2 / 2 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition, compliance with exposure requirements.

Attestation Statements

HangzhouWenzhongTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 9/27/24 U.S.AgentDesignation HangzhouWenzhongTechnologyCo.,Ltdacknowledgestheirconsentforthefollowingcontactlocatedinthe UnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCC ID:2BKXNYK433G40504): NameandcompanyofU.S.agent:AOCECorporationInc. PhysicalU.S.addressofagent: 6547NAcademyBivd#2266,ColoradoSprings,CO,80918 UnitedStates FRNofU.S.agent:0033401381 EmailaddressofU.S.agent:[email protected] AOCECorporationInc.acknowledgestheirobligationtoacceptserviceofprocessonbehalfofHangzhou WenzhongTechnologyCo.,Ltd. HangzhouWenzhongTechnologyCo.,LtdwiththeFRN0035929306acceptsitsobligationtomaintainan agentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature fengzhou Manager HangzhouWenzhongTechnologyCo.,Ltd Signature Johnson.wang Manager AOCECorporationInc. 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BKXNYK433G40504 WE-005, YK433MG40503 We, Applicant Company Name: Hangzhou Wenzhong Technology Co., Ltd Address: Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province 310000, China Phone: +86-15606699189 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-27 Signature Date Name / Title: Feng Zhou / Manager Company: Hangzhou Wenzhong Technology Co., Ltd Address: Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province 310000, China Phone: +86-15606699189 Fax: +86-15606699189 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BKXNYK433G40504 WE-005, YK433MG40503 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-27 Signature Date Name / Title: Feng Zhou / Manager Company: Hangzhou Wenzhong Technology Co., Ltd Address: Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province 310000, China Phone: +86-15606699189 Fax: +86-15606699189 E-Mail: [email protected]

Cover Letter(s)

Hangzhou Wenzhong Technology Co., Ltd Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province 310000, China Date: September 27, 2024 FCC ID: 2BKXNYK433G40504 Model Number: WE-005, YK433MG40503 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Hangzhou Wenzhong Technology Co., Ltd hereby declare that our product (remote control) Model Number: WE-005, YK433MG40503 board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Feng Zhou / Manager Company: Hangzhou Wenzhong Technology Co., Ltd Address: Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province 310000, China Phone: +86-15606699189 Fax: +86-15606699189 E-Mail: [email protected]

External Photos

Page 1 of 4 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7

ID Label/Location Info

Page 1 of 1 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 2.0cm x W 1.0cm) Label Location remote control Model: WE-005 FCC ID: 2BKXNYK433G40504

Internal Photos

Page 1 of 3 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Antenna Page 3 of 3 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5

RF Exposure Info

Page 1 of 3 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information Applicant Hangzhou Wenzhong Technology Co., Ltd Address Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Product name remote control Test Model WE-005 Additional Model No. YK433MG40503 Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Ratings DC 3.0V by 2*AAA battery Hardware Version / Software Version / Frequency Range 433.92MHz Channel Number 1 Modulation Type ASK Antenna Description Internal Antenna, 1.2dBi(Max) Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable Device 2.Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: Page 2 of 3 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b) The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Test Procedure TX frequency range: 433.92MHz Device category: Portable device (Distance: 5mm) Max. Field Strength: 63.14dBuV/m @3m EIRP=E-104.8+20logD=63.14-104.8+20log3=-32.12dBm Maximum Conducted Output Power: -32.12dBm Tune up: -32±1 5. Evaluation Results Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclusion Threshold SAR Test Exclusion dBm mW ASK 0.43392 5 -31 0.0008 0.0001< 3.0 Yes Remark: 1. Output power including tune up tolerance; 2. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. Page 3 o…

Text truncated - open the document above for the full version.

Test Report

Manufacturer: Hangzhou Wenzhong Technology Co., Ltd Address: Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Antenna size(mm) Antenna Model : WE-005 Frequenc Range: 433.92MHz Antenna Type : PCB Antenna Antenna Gain : 1.2dBi (Max) We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required.

Test Report

Page 1 of 28 FCC ID: 2BKXNYK433G40504 Report No.: LCSA09024253EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Hangzhou Wenzhong Technology Co., Ltd remote control Test Model: WE-005 Additional Model No.: YK433MG40503 Prepared for : Hangzhou Wenzhong Technology Co., Ltd Address : Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 05, 2024 Number of tested samples : 2 Sample No. : A240905017-1, A240905017-2 Serial number : Prototype Date of Test : September 05, 2024 ~ September 13, 2024 Date of Report : September 14, 2024 Page 2 of 28 FCC ID: 2BKXNYK433G40504 Report No.: LCSA09024253EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.231) Report Reference No. .............. : LCSA09024253EA Date of Issue ............................... : September 14, 2024 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ...................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ....... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ...................... : Hangzhou Wenzhong Technology Co., Ltd Address ...................................... : Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Test Specification Standard ..................................... : FCC CFR 47 PART 15 Subpart C, ANSI C63.10-2013 Test Report Form No. ............... : TRF-4-E-176 A/0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ................................. : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : remote control Trade Mark ................................. : N/A Test Model .................................. : WE-005 Ratings ....................................... : DC 3.0V by 2*AAA battery Result ........................................ : Positive Compiled by: Supervised by: Approved by: Nadia Zhou/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 28 FCC ID: 2BKXNYK433G40504 Report No.: LCSA09024253EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT EUT......................................... : remote control Test Model........................... : WE-005 Applicant............................... : Hangzhou Wenzhong Technology Co., Ltd Address.................................. : Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Telephone............................... : / Fax.......................................... : / Manufacturer....................... : Hangzhou Wenzhong Technology Co., Ltd Address................................... : Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Telephone............................... : / Fax.......................................... : / Factory....................... : Hangzhou Wenzhong Technology Co., Ltd Address................................... : Zhudong Village, Linpu Town, Xiaoshan District, Hangzhou City, Zhejiang Province China Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA09024253EA September 14, 2024 Date of issue Page 4 of 28 FCC ID: 2BKXNYK433G40504 Report No.: LCSA09024253EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 September 14, 2024 Initial Issue -- Page 5 of 28 FCC ID: 2BKXNYK433G40504 Report No.: LCSA09024253EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 FCC ID: 2BKXNYK433G40504 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

feng zhou
[email protected]15606699189Fax: 15606699189

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.