Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CONTENTS A.MONOINPUTCHANNELSECTION B.MASTERSECTION C.EFFECTSECTION D.MP3PLAYERSECTION E.MIXEROUTPUTSECTION F.REARVIEWSECTION G.INSTALLATION H.CONNECTIONS I.APPENDIX Ultralownoise8,12,16,24ChannelMic/Line/USBMixer ▲8,12,16,24MonoInputChannelswithXLRandUn/BalancedLine,INSERTInputs ▲2/4groupswithINSERTjack ▲2/3/4AuxSendperchannelforexternaleffectsandmonitoring ▲AUX1-2equipwithPre/Postfaderswitch(Optionalfunctionwithdifferencemodel) ▲Footswitchjack,Monitorjack,CD/TAPEinputandoutput ▲LowCutswitchoneachchannel. ▲EffectsendtoAUXwithindividualvolumecontrolknobs(Optionalfunction) ▲LongLEDLightwithswitch(Optionalfunctionwithdifferencemodel) ▲Mp3playerwithLCD,recordingandBluetooth.(Optionalfunctionwithdifferencemodel) ▲+48VPhantomPowerwithmainswitch ▲Uitra-musical4-bandEQonallchannels ▲PeakLEDsonallChannels, ▲Builtin200kindsDSPeffectprocessorwithLCDdislay. ▲4Highlyaccurate10segmentBargraphMetersforGROUPandMAINL/Routputs ▲Built-inswitchingpowersupply.(Externaladapterisoptionalwithdifferencemodel) 1-2 3 4-6 7 8 9 9 10-11 12 SAFETYINSTRUCTIONS CAUTION:Toreducetheriskofelectricalshock,donotremovethe cover(orback).Nouserserviceablepartsinside; referservicingtoqualifiedpersonnel. WARNING:Toreducetheriskoffireorelectricalshock,donot exposethisappliancetorainormoisture. CAUTION RISKOFELECTRICSHOCK D0NOTOPEN Thissymbol,whereveritappears,alertsyoutothe presenceofuninsulateddangerousvoltageinside theenclosure-voltagethatmaybesufficient toconstituteariskofshock. Thissymbol,whereveritappears,alerts youtoimportantoperatingand maintenanceinstructionsinthe manual. accompanyingliterature.Readthe - - 10. FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Miyako USA Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/19/2024 U.S. Agent Designation Miyako USA acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BKZN-FEUR2024): Name and company of U.S. agent: Miyako USA Physical U.S. address of agent: 1598 NW 108th Avenue. Miami, Florida 33172 United States FRN of U.S. agent: 0035930122 Email address of U.S. agent: [email protected] Miyako USA acknowledges their obligation to accept service of process on behalf of Miyako USA. Miyako USA with the FRN 0035930122 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Alejandro Rodriguez COO/VP Miyako USA Signature Alejandro Rodriguez COO/VP Miyako USA 48_[model] US_Agent_2.911(d)(7) - U, V05
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BKZN-FEUR2024 FU-AUL10, VZ-PROM8-AMP, FU-AUL16-AMP, FU-AUL16, FU-AUL24, P.A.0842, P.A.1242, P.A.1642, P.A.2442, LIVE AN8, LIVE AN12, LIVE AN16, GREY II6, GREY II8, KN PRO 8, KN PRO 12, KN PRO 16, KC 12 PRO, KC 16 PRO, KC 24 PRO, KC 32 PRO, KE 12 PRO, KE 16 PRO, KE 24 PRO, KC 4 PRO, KR 8 We, Applicant Company Name: Miyako USA Address: 1598 NW 108th Avenue. Miami, Florida 33172, United States Phone: +1-305-594-7855 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-19 Signature Date Name / Title: Alejandro Rodriguez / COO/VP Company: Miyako USA Address: 1598 NW 108th Avenue. Miami, Florida 33172, United States Phone: +1-305-594-7855 Fax: N/A E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BKZN-FEUR2024 FU-AUL10, VZ-PROM8-AMP, FU-AUL16-AMP, FU-AUL16, FU-AUL24, P.A.0842, P.A.1242, P.A.1642, P.A.2442, LIVE AN8, LIVE AN12, LIVE AN16, GREY II6, GREY II8, KN PRO 8, KN PRO 12, KN PRO 16, KC 12 PRO, KC 16 PRO, KC 24 PRO, KC 32 PRO, KE 12 PRO, KE 16 PRO, KE 24 PRO, KC 4 PRO, KR 8 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-19 Signature Date Name / Title: Alejandro Rodriguez / COO/VP Company: Miyako USA Address: 1598 NW 108th Avenue. Miami, Florida 33172, United States Phone: +1-305-594-7855 Fax: N/A E-Mail: [email protected]
Miyako USA 1598 NW 108th Avenue. Miami, Florida 33172, United States Date: September 19, 2024 FCC ID: 2BKZN-FEUR2024 Model Number: FU-AUL10, VZ-PROM8-AMP, FU-AUL16-AMP, FU-AUL16, FU-AUL24, P.A.0842, P.A.1242, P.A.1642, P.A.2442, LIVE AN8, LIVE AN12, LIVE AN16, GREY II6, GREY II8, KN PRO 8, KN PRO 12, KN PRO 16, KC 12 PRO, KC 16 PRO, KC 24 PRO, KC 32 PRO, KE 12 PRO, KE 16 PRO, KE 24 PRO, KC 4 PRO, KR 8 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Miyako USA hereby declare that our product (MIXING CONSOLE) Model Number: FU-AUL10, VZ-PROM8-AMP, FU-AUL16-AMP, FU-AUL16, FU-AUL24, P.A.0842, P.A.1242, P.A.1642, P.A.2442, LIVE AN8, LIVE AN12, LIVE AN16, GREY II6, GREY II8, KN PRO 8, KN PRO 12, KN PRO 16, KC 12 PRO, KC 16 PRO, KC 24 PRO, KC 32 PRO, KE 12 PRO, KE 16 PRO, KE 24 PRO, KC 4 PRO, KR 8 board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Alejandro Rodriguez / COO/VP Company: Miyako USA Address: 1598 NW 108th Avenue. Miami, Florida 33172, United States Phone: +1-305-594-7855 Fax: N/A E-Mail: [email protected]
Page 1 of 5 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10
Page 1 of 1 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 10.0cm x W 3.0cm) Label Location MIXING CONSOLE Model: FU-AUL10 FCC ID: 2BKZN-FEUR2024
Page 1 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 BT ANT Page 4 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 9 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18
Page 1 of 4 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information FCC ID : 2BKZN-FEUR2024 EUT : MIXING CONSOLE Test Model : FU-AUL10 Additional Model No. : VZ-PROM8-AMP,FU-AUL16-AMP,FU-AUL16,FU-AUL24,P.A.0842, P.A.1242,P.A.1642,P.A.2442,LIVE AN8,LIVE AN12,LIVE AN16, GREY II6,GREY II8,KN PRO 8,KN PRO 12,KN PRO 16,KC 12 PRO, KC 16 PRO,KC 24 PRO,KC 32 PRO,KE 12 PRO,KE 16 PRO, KE 24 PRO, KC 4 PRO,KR 8 Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply : Input: 110-240V AC, 50/60Hz Hardware Version : / Software Version : / Bluetooth Frequency Range : 2402MHz~2480MHz Channel Number : 79 channels for Bluetooth V5.0(DSS) 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 1MHz for Bluetooth V5.0 (DSS) 2MHz for Bluetooth V5.0 (DTS) Modulation Type : GFSK, π/4-DQPSK for Bluetooth V5.0(DSS) GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Description : PCB Antenna, -0.68dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power Page 2 of 4 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna Page 3 of 4 FCC ID:2BKZN-FEUR2024 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Antenna Information PCB Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna PCB Antenna 2402MHz ~ 2480MHz -0.68dBi Bluetooth Antenna 6. Conducted Power [BT] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.6 39 2441 0.67 79 2480 0.41 π/4-DQPSK 0 2402 0.29 39 2441 0.19 79 2480 -0.16 [BT LE] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.53 19 2440 -0.07 39 2480 -0.12 7. Manufacturing Tolerance <BT> GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 0 0 0 Tolerance ± (dB) 1.0 1.0 1.0 π/4DQPSK (Peak) Ch…
Text truncated - open the document above for the full version.
InvertedFAntennaSpecification Summary ITEMANTSPEC ModelName2.4GANT Center HorizontalVertical 2400MHz2400MHz2500MHz2400MHz2400MHz2500MHz Frequency -1.73-0.84-0.68-6.15-3.70-2.32 MAX.Gain-0.68 PolarizationHorizontalandVertical AzimuthBeam Omni-directional Pattern Impedance50Ohm AntennaLength38.20mm ManufactureZHUHAIJIELITECHNOLOGYCO.,LTD AntennaPhoto&Length(mm) Address No. 333 Kexing Road, Nanping Town, Zhuhai, China Horizontal:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-40Scale:5/div FrequencyGain(dBi) (MHz)MaxMinAvg 2400-1.73178-30.0815-8.48713 2450-0.845801-38.5605-7.88012 2500-0.685586-24.0318-6.79139 Vertical:2400MHz2450MHz2500MHz Power(dBm) Max:0Min:-30Scale:5/div FrequencyGain(dBi) (MHz)MaxMinAvg 2400-6.1530-24.1420-13.0295 2450-3.7054-26.5836-10.6700 2500-2.32122-30.4301-9.70536 ANTTestLabs : AttestationofGlobalComplianceCo.,Ltd.
Page 1 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B RF Test Data for BT LE (Conducted Measurement) Product Name: MIXING CONSOLE Test Model: FU-AUL10 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Paddi Chen Supervised by: Nick Peng Page 2 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 2402 Ant 0.643 >=0.5 Pass NVNT BLE 2440 Ant 0.655 >=0.5 Pass NVNT BLE 2480 Ant 0.656 >=0.5 Pass Page 3 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 2402MHz Ant -6dB Bandwidth NVNT BLE 2440MHz Ant Page 4 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2480MHz Ant Page 5 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT BLE 2402 Ant -0.53 30 Pass NVNT BLE 2440 Ant -0.07 30 Pass NVNT BLE 2480 Ant -0.12 30 Pass Page 6 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 2402MHz Ant Power NVNT BLE 2440MHz Ant Page 7 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2480MHz Ant Page 8 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 2402 Ant -17.38 8 Pass NVNT BLE 2440 Ant -16.64 8 Pass NVNT BLE 2480 Ant -16.96 8 Pass Page 9 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 2402MHz Ant PSD NVNT BLE 2440MHz Ant Page 10 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 2480MHz Ant Page 11 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 2402 Ant -55.47 -20 Pass NVNT BLE 2480 Ant -56.76 -20 Pass Page 12 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 2402MHz Ant Ref Band Edge NVNT BLE 2402MHz Ant Emission Page 13 of 23 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs…
Text truncated - open the document above for the full version.
Page 1 of 34 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For MIYAKO USA MIXING CONSOLE Test Model: FU-AUL10 Additional Model No.: Please Refer to Page 6 Prepared for : MIYAKO USA Address : 1598 NW 108TH AVENUE. MIAMI, FLORIDA 33172, USA Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 04, 2024 Number of tested samples : 2 Sample No. : A240902067-1, A240902067-2 Serial number : Prototype Date of Test : September 04, 2024 ~ September 12, 2024 Date of Report : September 13, 2024 Page 2 of 34 FCC ID:2BKZN-FEUR2024 Report No.: LCSA09024170EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA09024170EB Date of Issue .................................. : September 13, 2024 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : MIYAKO USA Address .......................................... : 1598 NW 108TH AVENUE. MIAMI, FLORIDA 33172, USA Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : TRF-4-E-145 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rig…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 980.00 µW |