Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 02, 2024
Application Purpose
Original Equipment
Date of Application
Sep 29, 2024
Equipment Note
Smart Pet Feeder
Frequency Range
2412.00000000 - 2462.00000000
Company
Ningbo Thriving Intelligent Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

02 丨 Connect the power supply ◎ Plug the 5V/1A power adapter into the wall socket and connect the device. ◎ After plugging in, the bottom of the equipment is a rocker switch, which needs to turn on.and the LED light will light up, indicating that the feeder is powered on. bottom of the feeder and install 3 pcs Size power failure Note: 2) Before turning on the power, make sure ◎ Complete assembly according to the steps. 01 丨 Installation Instructions Button Description Feed: of food. 尺寸:840X160MM,单页120X160MM,七折页 Reset:Long press for 7 seconds (reset) to emit " reset successfully" three sounds, red/blue indicator light is always on for 6 seconds to switch to slow allocation. (Repeat long-press operation to switch between the two modes) 2 times to dispense 04 丨 Feed 7、Main page, you can choose the number of servings according to your needs, and tap "Feed" to feed immediately. watch pey" to view pet dynamics at one-key feeding feeding" to add timed feeding.of portions according to the pet's 8、Point the main interface "Add 11、Into the setup options, select the number of voice playback, can offline reminders, modify the device night vision switch 9、You can set the time and number ea ting pattern, set it to daily, you can choose Monday to Sunday, tap save. 12、Point settings can be turned on namerestore the factory settings, infraredany time, support for remote Simple Troubleshooting Programs for problem solving Ningbo Thriving Intelligent Technology Co., LTD Q:The App can't connect to the feeder A:1) Please check if the Wi-Fi name and password are in Chinese or longer than 12 digits, and make sure the Wi-Fi type is 2.4G. automatically on boot, turn on the Bluetooth and positioning of your phone, Q:The feeder does not dispense food properly or does not dispense food at all A:Please check if there is too much grain in the food bowl or if it causes blockage of the grain passage, if so, please clean the grain passage and the A:Please check whether the distance of the feeder from your home router is walls in the middle, according to the characteristics of Wi-Fi, the Wi-Fi signal across the wall will drop sharply, and the connection appears to be unstable, Q:No response to power on A:Please make sure the power is plugged in. If the check is correct and the device still does not power on normally, please contact your dealer or 7S 05丨 Reset ◎ Press and hold for 7 seconds to make a " reset successfully" sound, schedule, feeding records, etc. ◎ After reset, you can re-distribute the network. 7S X2 VideoType Instruction Manual Model: PF002V Please Read the Manual Carefully Before Using the Product User Manual Packing List After opening the product package, please make sure the pet feeder is intact, please check the list to make sure the accessories are complete. 2 Power Cord 4 User Manual 1 Food bowl Accessories Product Image Front view Bottom view Indicator light color equipment status Indicator light color Indicator light signal equipment status Blue Red 03 丨 Pour the pet food ◎ Open the lid by holding the buckles on both sides to open it outward; ◎ Close the lid and press the buckle on both sides to secure it. Notes: 1) Do not place canned, wet or damp pet food. 2) Recommended pet food size range is 3-13 mm. 1、Download the App to register an exclusive account 4、Enter the Wi-Fi password (the name cannot use Chinese, and the password cannot use special symbols) 2、Enter the App home page and add devices 5、Wait for the device to connect to the network 3、Open the phone Bluetooth, wait corresponding device 6、The device is added successfully, click Finish. 3 Power Adapter (selectable) Cleaning and Maintenance 1. For your pet's health, regular cleaning of the unit is recommended. can remove the food cover to clean it. 3. Use a soft damp cloth to clean the base of the appliance which contains the control panel. 4. Do not wet the appliance and do not use running water for cleaning. 5.Do not put the product in the dishwasher as it will be permanently damaged! Food tank capacity: 4L Power supply: DC 5V/1A power adapter; 3pcs alkaline batteries Power adapter: AC110-240V input, DC5V output Size: 31.05*18.5 *33.4CM Cleaning Instructions (2)The base of the main unit can be wiped with a damp towel, do not rinse with water (1)Rinse in water or with food-grade detergent Safety Instructions 1. When using this product with children, please use it with a parent. 2. Do not use the feeder on pets that cannot reach the food dish or have physical disabilities. 4. Do not immerse the feeder in water to avoid component damage. 5. Do not place canned or wet food in the feeder. 6. Do not disassemble or modify the equipment by yourself. pet feeder by yourself, contact your dealer immediately and resolve the problem. 8. Be sure to unplug the product when not in use or before cleaning the product. 10.Do not allow your pet to chew or swallow any of the accessories. 11.Do not use damaged power cords or plugs. 12.Do not install or store the pet feeder in an exposed area. The ambient temperature for storage should be within the range of -10°C~40°C. 13. Use alkaline 1 size batteries for power supply. Do not use rechargeable batteries. you are traveling for a long time or on business. 15.Do not lift the feeder directly by the lid, food bucket or food tray. Use both position. or block the food opening. 17.Ensure that the pet food is fresh,it is recommended that user replacethe packaging. Please read the instruction manual carefully before using the product and keep it in a safe place. Base Lid Food tank Control panel Food dish Food Chute Food tank bottom Desiccant 304 stainless steel bowl 185mm 334mm 310.5mm Flashing Stay on Stay on Flashing Flashing Yellow Green To be set network Network connected Network connecting failure Food get stuck Feeding ②Installing the bucket Put the bucket into the corresponding buckle track according to the illustration, align with the mark, and rotate clockwise from ① to ② until you hear a click. Tighten it, and…

Text truncated - open the document above for the full version.

Attestation Statements

AttestationStatements Date:2024-09-23 TO:FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046,USA RE:AttestationStatementsPart2.911(d)(7)requestfor(FCCID:2BKZO-PF) NingboThrivingIntelligentTechnologyCo.,LTD,theundersigned,herebyauthorize BellababyMedicalDeviceInctoactasourdesignatedU.S.agentforserviceofprocess, NingboThrivingIntelligentTechnologyCo.,LTDacceptstomaintainanagentforno lessthanoneyearafterthegranteehasterminatedallmarketingandimportationor theconclusionofanyCommission-relatedproceedinginvolvingtheequipment. BellababyMedicalDeviceIncacceptstheresponsibilitytoactasdesignatedU.S.agent forserviceofprocess. Applicant Information : Company name: Ningbo Thriving Intelligent Technology Co., LTD Contact Name: JACK ZHANG Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Telephone No: 86 13336865152 Email:[email protected] FRN: 0035934173 Signature: U.S.AgentInformation: Com pa ny Name: Bellaba by Medi cal Devi ce Inc Addr ess: 30 N GOULD ST STE R SHER IDAN WY 82801 USA FRN:0035983436 Cont act Name: JACK ZH ANG Te lephone No: +626- 8100060 Em ail: [email protected] Signature:

Cover Letter(s)

Effective Date: April 2, 2020 QSF7.6.4-8– Agent Authorization Letter Template Page1 of1 Revision Date: Revision: 0 Ningbo Thriving Intelligent Technology Co., LTD Date:9/20/2024 Product Model Number: PF002V,PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V,PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V FCC ID:2BKZO-PF To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 NorthFraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare thatQAI Laboratories Ltd. is allowed toforward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By:JACK ZHANG Contact Listed on FCC Wesbite Title: RA Email:[email protected] On behalf of: Ningbo Thriving Intelligent Technology Co., LTD

Cover Letter(s)

Ningbo Thriving Intelligent Technology Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date:September 20, 2024 Subject; Request for Confidentiality FCC ID:2BKZO-PF To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might beharmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: JACK ZHANG Title:RA

Cover Letter(s)

Ningbo Thriving Intelligent Technology Co., LTD Declaration Letter of Model Difference Date: 9/20/2024 Tested Model Number: PF002V Adding Model Number(s): PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W,PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V All Adding Model Number(s)is/are same electrically identical as Tested Model Number. Only model namesare different for marketpurpose. Yours Sincerely, Applicant: Ningbo Thriving Intelligent Technology Co., LTD Address:45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Contact Person:JACK ZHANG Tel.:86 13336865152 Email: [email protected] Sincerely, Signature:

Cover Letter(s)

Xinhengyang Antenna Test Data Report Customer Name Anfu Youyou Project Name AFU0099 U R Proj ect Hsiang 1 frequ ency band 2400-2500MHZ 2 Project Type Pet food dispenser 3 Ter mina ls Generation 4 Feed Point Type doubly-fed 5 Line lengt h Wire diameter: 1.13 L = 170MM 6 Antenna Type PIFA 7 Antenna Material FPC 8 Rem arks Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen Directory 1 Test darkroom profile 2. machine picture 3. Antenna assembly 4. Passive standing wave diagram 5. Passive field pattern diagram six. Passive Efficiency & Gain Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen 1. Introduction to Test Darkroom 1. Active test: support 2.3.4.5G standard multi-mode measurement NB-loT, eMTC,CAT- 1,Bluetooth1-5 ,WIFI 802.11 abgn, measurable TRP TIS 2. Passive test: can test gain, efficiency 3.TWS Headset Test Head Model Full Head Hand Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen 2 Antenna picture Antenna Length: 14mm x 35mm Wire diameter: 1.13 L = 170mm Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen 3 Antenna assembly Antenna assembly as shown Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen 4 passive standing wave diagram Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen 5 passive field pattern diagram E1 ( XZ) E2 (YZ) H (XY) Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen VI. Passive Efficiency & Gain Freq (MHz) Effi (%) Gain (dBi) 2400 55.46 3.13 2410 55.40 3.00 2420 56.10 2.79 2430 56.30 2.70 2440 58.09 3.00 2450 58.59 3.11 2460 58.55 3.15 2470 58.77 3.06 2480 60.41 3.06 2490 62.25 3.01 2500 64.86 3.23 Manufacturer : Shenzhen Xinhengyang Technology Co., Ltd. Room 7A-909, 8th Floor, West Block, Kanghe Sheng Building, No.1 Xili Chuangsheng Road, Nanshan District, Shenzhen Thank you

External Photos

Page 1 of 4 Report No.: LGT24I029 Appendix - External Photographs of EUT Constructional Details Model: PF002V Photo 1 Photo 2 Page 2 of 4 Report No.: LGT24I029 Photo 3 Photo 4 Page 3 of 4 Report No.: LGT24I029 Photo 5 Photo 6 Page 4 of 4 Report No.: LGT24I029 Photo 7 Photo 8

ID Label/Location Info

Label FCC ID: 2BKZO-PF

Internal Photos

Page 1 of 6 Report No.: LGT24I029 Appendix - Internal Photographs of EUT Constructional Details Model: PF002V Photo 1 Photo 2 Page 2 of 6 Report No.: LGT24I029 Photo 3 Photo 4 ANT Page 3 of 6 Report No.: LGT24I029 Photo 5 Photo 6 Page 4 of 6 Report No.: LGT24I029 Photo 7 Photo 8 Page 5 of 6 Report No.: LGT24I029 Photo 9 Photo 10 Page 6 of 6 Report No.: LGT24I029 Photo 11 Photo 12

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China RF TEST REPORT Product Name: Smart Pet Feeder Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V FCC ID: 2BKZO-PF Issued For : Ningbo Thriving Intelligent Technology Co., LTD 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT24I029HA03 Sample Received Date: Sep. 06, 2024 Date of Test: Sep. 06, 2024 ~ Sep. 19, 2024 Date of Issue: Sep. 19, 2024 Report No.: LGT24I029HA03 Page 2 of 9 TEST REPORT CERTIFICATION Applicant: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Manufacture: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Product Name: Smart Pet Feeder Trademark: N/A Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1091 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT24I029HA03 Page 3 of 9 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 EUT OPERATION CONDITION 7 2.4 CLASSIFICATION 7 2.5 TEST RESULT 8 APPENDIX I - PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS 9 Report No.: LGT24I029HA03 Page 4 of 9 Revision History Rev. Issue Date Revisions 00 Sep. 19, 2024 Initial Issue Report No.: LGT24I029HA03 Page 5 of 9 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Smart Pet Feeder Trademark: N/A Model Name: PF002V Series Model: PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V Model Difference: Only the model is different. Frequency Bands: BLE 2402~2480 MHz 2.4G WLAN 802.11b/g/n(20MHz): 2412~2462MHz 802.11n(40MHz):2422~2452MHz Rating: Input: DC 5V 1A Hardware Version: N/A Software Version: N/A 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate A2LA Certificate No.: 6727.01 FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT24I029HA03 Page 6 of 9 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 0.3-3.0 614 1.63 *(100) 3.0-30 1842/f 4.89/f *(900/f 2 ) 30-300 61.4 0.163 1.0 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 1.34-30 824/f 2.19/f *(180/f 2 ) 30-300 27.5 0.073 0.2 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F= Frequency in MHz * = Plane-wave equivalent power density. Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Report No.: LGT24I029HA03 Page 7 of 9 2.3 EUT OPERATION CONDITION EUT was enabled to transmit and receive at lowest, middle and highest channels. 2.4 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. Report No.: LGT24I029HA03 Page 8 of 9 2.5 TEST RESULT Turn up Result Mode Turn up Power BLE-GFSK 1±1dBm 2.4G WIFI-802.11b 16±1dBm 2.4G WIFI-802.11g 15…

Text truncated - open the document above for the full version.

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China RF TEST REPORT Product Name: Smart Pet Feeder Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V FCC ID: 2BKZO-PF Issued For : Ningbo Thriving Intelligent Technology Co., LTD 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT24I029RF03 Sample Received Date: Sep. 06, 2024 Date of Test: Sep. 06, 2024 ~ Sep. 19, 2024 Date of Issue: Sep. 19, 2024 Report No.: LGT24I029RF03 Page 2 of 46 TEST REPORT CERTIFICATION Applicant: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Manufacturer: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Product Name: Smart Pet Feeder Trademark: N/A Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2013 KDB558074 D01 15.247 Meas Guidance v05r02 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT24I029RF03 Page 3 of 46 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 12 3.1 CONDUCTED EMISSION MEASUREMENT 12 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 EUT OPERATING CONDITIONS 13 3.5 TEST RESULTS 14 4. RADIATED EMISSION MEASUREMENT 16 4.1 RADIATED EMISSION LIMITS 16 4.2 TEST PROCEDURE 18 4.3 TEST SETUP 18 4.4 EUT OPERATING CONDITIONS 19 4.5 FIELD STRENGTH CALCULATION 19 4.6 TEST RESULTS (BAND EDGE REQUIREMENTS) 25 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 27 5.1 LIMIT 27 5.2 TEST PROCEDURE 27 5.3 TEST SETUP 27 5.4 EUT OPERATION CONDITIONS 27 5.5 TEST RESULTS 27 6. POWER SPECTRAL DENSITY TEST 28 6.1 LIMIT 28 6.2 TEST PROCEDURE 28 6.3 TEST SETUP 28 6.4 EUT OPERATION CONDITIONS 28 Report No.: LGT24I029RF03 Page 4 of 46 6.5 TEST RESULTS 28 7. BANDWIDTH TEST 29 7.1 LIMIT 29 7.2 TEST PROCEDURE 29 7.3 TEST SETUP 29 7.4 EUT OPERATION CONDITIONS 29 7.5 TEST RESULTS 29 8. PEAK OUTPUT POWER TEST 30 8.1 LIMIT 30 8.2 TEST PROCEDURE 30 8.3 TEST SETUP 30 8.4 EUT OPERATION CONDITIONS 30 8.5 TEST RESULTS 30 9. ANTENNA REQUIREMENT 31 9.1 STANDARD REQUIREMENT 31 9.2 EUT ANTENNA 31 APPENDIX I - TEST RESULTS 32 MAXIMUM PEAK CONDUCTED OUTPUT POWER 32 -6DB BANDWIDTH 33 OCCUPIED CHANNEL BANDWIDTH 35 MAXIMUM POWER SPECTRAL DENSITY LEVEL 37 BAND EDGE 39 CONDUCTED RF SPURIOUS EMISSION 42 APPENDIX II - MEASUREMENT PHOTOS 45 APPENDIX III - PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS 46 Report No.: LGT24I029RF03 Page 5 of 46 Revision History Rev. Issue Date Revisions 00 Sep. 19, 2024 Initial Issue Report No.: LGT24I029RF03 Page 6 of 46 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 Part 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2013. Report No.: LGT24I029RF03 Page 7 of 46 1.1 TEST FACTORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate A2LA Certificate No.: 6727.01 FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.68dB 2 Unwanted Emissions, conducted ±2.988dB 3 All emissions, radiated 9K-30MHz ±2.84dB 4 All emissions, radiated 30M-1GHz ±4.39dB 5 All emissions, radiated 1G-6GHz ±5.10dB 6 All emissions, radiated>6G ±5.48dB 7 Conducted Emission (9KHz-150KHz) ±2.79dB 8 Conducted Emission (150KHz-30MHz) ±2.80dB Note: The measurement uncertainty is not included in the test result. Report No.: LGT24I029RF03 Page 8 of 46 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Smart Pet Feeder Trademark: N/A Model Name: PF002V Series Model: PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S,…

Text truncated - open the document above for the full version.

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China RF TEST REPORT Product Name: Smart Pet Feeder Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V FCC ID: 2BKZO-PF Issued For : Ningbo Thriving Intelligent Technology Co., LTD 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT24I029RF04 Sample Received Date: Sep. 06, 2024 Date of Test: Sep. 06, 2024 ~ Sep. 19, 2024 Date of Issue: Sep. 19, 2024 Report No.: LGT24I029RF04 Page 2 of 66 TEST REPORT CERTIFICATION Applicant: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Manufacturer: Ningbo Thriving Intelligent Technology Co., LTD Address: 45-1# Bei Yi Huan Road, Zhang qi Town, Cixi City, Ningbo, Zhejiang Province, China Product Name: Smart Pet Feeder Trademark: N/A Model Name: PF002V, PF002S, PF002W, PF001S, PF001W, PF001V, PF003S, PF003W, PF003V, PF004S, PF004W, PF004V, PF005S, PF005W, PF005V, PF006S, PF006W, PF006V, PF007S, PF007W, PF007V, PF008S, PF008W, PF008V, PF009S, PF009W, PF009V Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2013 KDB558074 D01 15.247 Meas Guidance v05r02 PASS Prepared by: Approved by: Zane Shan Vita Li Engineer Technical Director Report No.: LGT24I029RF04 Page 3 of 66 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 RADIATED EMISSION MEASUREMENT 17 4. CONDUCTED SPURIOUS & BAND EDGE EMISSION 28 4.1 LIMIT 28 4.2 TEST PROCEDURE 28 4.3 DEVIATION FROM STANDARD 28 4.4 TEST SETUP 28 4.5 EUT OPERATION CONDITIONS 28 4.6 TEST RESULTS 28 5. POWER SPECTRAL DENSITY TEST 29 5.1 LIMIT 29 5.2 TEST PROCEDURE 29 5.3 DEVIATION FROM STANDARD 29 5.4 TEST SETUP 29 5.5 EUT OPERATION CONDITIONS 29 5.6 TEST RESULTS 29 6. BANDWIDTH TEST 30 6.1 LIMIT 30 6.2 TEST PROCEDURE 30 6.3 DEVIATION FROM STANDARD 30 6.4 TEST SETUP 30 6.5 EUT OPERATION CONDITIONS 30 6.6 TEST RESULTS 30 Report No.: LGT24I029RF04 Page 4 of 66 7. PEAK OUTPUT POWER TEST 31 7.1 LIMIT 31 7.2 TEST PROCEDURE 31 7.3 DEVIATION FROM STANDARD 31 7.4 TEST SETUP 31 7.5 EUT OPERATION CONDITIONS 31 7.6 TEST RESULTS 31 8. ANTENNA REQUIREMENT 32 8.1 STANDARD REQUIREMENT 32 8.2 EUT ANTENNA 32 APPENDIX I - TEST RESULTS 33 MAXIMUM PEAK CONDUCTED OUTPUT POWER 33 -6DB BANDWIDTH 34 OCCUPIED CHANNEL BANDWIDTH 39 MAXIMUM POWER SPECTRAL DENSITY LEVEL 44 BAND EDGE 49 CONDUCTED RF SPURIOUS EMISSION 56 APPENDIX II - MEASUREMENT PHOTOS 65 APPENDIX III - PHOTOGRAPHS OF…

Text truncated - open the document above for the full version.

Contact Information

Applicant

JACK ZHANG(RA)
[email protected]86 13336865152Fax: 86 13336865152

Technical Contact

Ningbo Thriving Intelligent Technology Co., LTD
[email protected]

China

Test Firm

Shenzhen LGT Test Service Co., Ltd.Wen Wen
[email protected]0755-89668180

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz43.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.