2BLAA-FE-4601Eye massager

Xiamen Healthpal Electronic Co.,ltd.
Eye massager - FCC ID 2BLAA-FE-4601 - Xiamen Healthpal Electronic Co.,ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 28, 2024
Application Purpose
Original Equipment
Date of Application
Sep 27, 2024
Equipment Note
Eye massager
Frequency Range
2402.00000000 - 2480.00000000
Company
Xiamen Healthpal Electronic Co.,ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Air pressure function FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition, compliance with exposure requirements.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BLAA-FE-4601 FE-4601, FE-4615, FE-4616, FE-4619, FE-4608, FE-4611, FE-4609, FE-4613, FE-4614, FE-4654, FE-4605, FE-4600, FE-4602, FE-4603, FE-4604, FE-4652, FE-4612 We, Applicant Company Name: Xiamen Healthpal Electronic Co., ltd. Address: NO.148 BINGLANGXILI, SIMINGDISTRICT, XIAMEN, FUJIAN 361000, China Phone: +86-15985815020 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-24 Signature Date Name / Title: Yating Fang / Merchandiser Company: Xiamen Healthpal Electronic Co., ltd. Address: NO.148 BINGLANGXILI, SIMINGDISTRICT, XIAMEN, FUJIAN 361000, China Phone: +86-15985815020 Fax: +86-592-5360446 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BLAA-FE-4601 FE-4601, FE-4615, FE-4616, FE-4619, FE-4608, FE-4611, FE-4609, FE-4613, FE-4614, FE-4654, FE-4605, FE-4600, FE-4602, FE-4603, FE-4604, FE-4652, FE-4612 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-24 Signature Date Name / Title: Yating Fang / Merchandiser Company: Xiamen Healthpal Electronic Co., ltd. Address: NO.148 BINGLANGXILI, SIMINGDISTRICT, XIAMEN, FUJIAN 361000, China Phone: +86-15985815020 Fax: +86-592-5360446 E-Mail: [email protected]

Cover Letter(s)

Xiamen Healthpal Electronic Co., ltd. NO.148 BINGLANGXILI, SIMINGDISTRICT, XIAMEN, FUJIAN 361000, China Date: September 24, 2024 FCC ID: 2BLAA-FE-4601 Model Number: FE-4601, FE-4615, FE-4616, FE-4619, FE-4608, FE-4611, FE-4609, FE-4613, FE-4614, FE-4654, FE-4605, FE-4600, FE-4602, FE-4603, FE-4604, FE-4652, FE-4612 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Xiamen Healthpal Electronic Co., ltd. hereby declare that our product (Eye massager) Model Number: FE-4601, FE-4615, FE-4616, FE-4619, FE-4608, FE-4611, FE-4609, FE-4613, FE-4614, FE-4654, FE-4605, FE-4600, FE-4602, FE-4603, FE-4604, FE-4652, FE-4612 board, Schematic, Hardware version, Software version, structure and internal photos are same, named and appearance differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Yating Fang / Merchandiser Company: Xiamen Healthpal Electronic Co., ltd. Address: NO.148 BINGLANGXILI, SIMINGDISTRICT, XIAMEN, FUJIAN 361000, China Phone: +86-15985815020 Fax: +86-592-5360446 E-Mail: [email protected]

External Photos

Page1of4FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.0cmxW2.0cm) LabelLocation Eyemassager Model:FE-4601 FCCID:2BLAA-FE-4601

Internal Photos

Page1of5FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of5FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Antenna Page4of5FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10

RF Exposure Info

Page1of3FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation Productname:Eyemassager TestModel:FE-4601 AdditionalModelNo.:FE-4615,FE-4616,FE-4619,FE-4608,FE-4611,FE-4609, FE-4613,FE-4614,FE-4654,FE-4605,FE-4600,FE-4602, FE-4603,FE-4604,FE-4652,FE-4612 ModelDeclaration:PCBboard,structureandinternalofthesemodel(s)arethe same,Sonoadditionalmodelsweretested Ratings:DC3.7VbyRechargeableLi-ionBattery,2500mAh HardwareVersion:V1.0 SoftwareVersion:V003 BluetoothFrequencyRange:2402MHz~2480MHz ChannelNumber:79channelsforBluetoothV5.0(DSS) ChannelSpacing:1MHzforBluetoothV5.0(DSS) ModulationType:GFSK,π/4-DQPSKforBluetoothV5.0(DSS) BluetoothVersion:V5.0 AntennaDescription:PCBAntenna,1.54dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:PortableDevice Page2of3FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationmethodandLimit AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulation exposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.22Theminimumtestseparationdistance isdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,toany partofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval,in lieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets, laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]¡[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is≤ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices Page3of3FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPowerResults <BT> ModeChannelFrequency(MHz)PeakConductedOutputPower(dBm) GFSK 02402-0.15 392441-0.32 7824800.21 π/4DQPSK 024020.19 3924410.85 782480-0.36 5.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 ToleranceÂą(dB)1.01.01.0 π/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 ToleranceÂą(dB)1.01.01.0 6.EvaluationResults 6.1StandaloneEvaluation Band/Mode Frequ ency (GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW BT GFSK2.48051.01.25890.3965<3.0Yes π/4DQPSK2.48051.01.25890.3965<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)insection 4.1isappliedtodetermineSARtestexclusion. 6.2SimultaneousTransmissionforSARExclusion ThesamplesupportoneBTmodular.Noneedconsidersimultaneoustransmission. 7.Conclusion Themeasurementresultscomplyw…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 37 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR XiamenHealthpalElectronicCo.,Ltd. Eyemassager TestModel:FE-4601 AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:XiamenHealthpalElectronicCo.,Ltd. Address: NO.148BINGLANGXILI,SIMINGDISTRICT,XIAMEN,FUJIAN, CHINA Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September05,2024 Numberoftestedsamples:2 SampleNo.:A240904084-1,A240904084-2 Serialnumber:Prototype DateofTest:September05,2024~September13,2024 DateofReport:September14,2024 Page 2 of 37 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA09034142EA DateofIssue.......................................:September14,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:XiamenHealthpalElectronicCo.,Ltd. Address................................................: NO.148BINGLANGXILI,SIMINGDISTRICT,XIAMEN,FUJIAN, CHINA TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:TRF-4-E-148A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:Eyemassager TradeMark..........................................:N/A TestModel...........................................:FE-4601 Ratings.................................................:DC3.7VbyRechargeableLi-ionBattery,2500mAh Result..................................................:Positive Compiledby:Supervisedby:Approvedby: JokerHu/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 37 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA09034142EA September14,2024 Dateofissue TestModel.............................. : FE-4601 EUT......................................... : Eyemassager Applicant...............................:XiamenHealthpalElectronicCo.,Ltd. Address...................................:NO.148BINGLANGXILI,SIMINGDISTRICT,XIAMEN,FUJIAN, CHINA Telephone...............................: / Fax..........................................:/ Manufacturer.........................:XiamenVanflyHealthScience&TechnologyCo.,Ltd Address...................................:4F,No.1019-2,WanjiachunRoad,TorchHigh-Technic Zone(Xiang'an)IndustrialPark,Xiamen Telephone...............................: / Fax..........................................:/ Factory...................................:XiamenVanflyHealthScience&TechnologyCo.,Ltd Address...................................: 4F,No.1019-2,WanjiachunRoad,TorchHigh-Technic Zone(Xiang'an)IndustrialPark,Xiamen Telephone...............................:/ Fax..........................................:/ Page 4 of 37 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000September14,2024InitialIssue--- Page 5 of 37 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION.................................................................................................................6 1.1DescriptionofDevice(EUT)........................................................................................................................6 1.2SupportequipmentList.................................................................................................................................7 1.3ExternalI/OCable..........................…

Text truncated - open the document above for the full version.

Test Report

1 Antenna Test Report Manufacture : Xiamen Luoerte Technology Co., Ltd ProductName : PCBAntenna AntennaType : PCB TestDate : 2024/09/05 Tested by: Judson Du Approvedby : 2 1. General Description Manufacturer Xiamen Luoerte Technology Co., Ltd Address 301D2,No. 34-1 Guanri Road, Phase II, Software Park, Siming District, Xiamen city Test Location No. 113, Pingkang Road, Dalang Town, Dongguan City, Guangdong Province Product NamePCB Antenna Antenna Type PCB Test Items Gain; Efficiency; Radiation Pattern Test Frequency 2402-2480MHz 3 2. TestConfigurations Test Environment Temperature ( °C ) 22.3 Humidity (%RH)54.3 Atmospheric Pressure (kPa)101.9 Test Equipment Test Instrument Agilent ZNB8 4 3. TestResults Gain and Efficiency Frequency (MHz)Peak Gain (dBi) Efficiency (%) 2402-0.5833.63 24400.6145.49 2480 1.5455.44 4. RadiationPattern 2402MHz 3D Theta=90,Phi=0 Theta = 0, Phi = 0 Theta = 90, Phi = 270 Theta=90,Phi=90 Theta = 90, Phi = 180 Theta = 180, Phi = 0 5 6 2440MHz 3D Theta=90,Phi=0 Theta = 0, Phi = 0 Theta = 90, Phi = 270 Theta=90,Phi=90 Theta = 90, Phi = 180 Theta = 180, Phi = 0 7 2480MHz 3D Theta=90,Phi=0 Theta = 0, Phi = 0 Theta = 90, Phi = 270 Theta=90,Phi=90 Theta = 90, Phi = 180 Theta = 180, Phi = 0 8 5. EUTPhoto Antenna 6. TestSetupPhoto

Test Report

Page 1 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBT(ConductedMeasurement) ProductName:Eyemassager TestModel:FE-4601 EnvironmentalConditions Temperature: 23.8  C RelativeHumidity:52.1% ATMPressure:100.0kPa TestEngineer:JerryChu Supervisedby:NickPeng Page 2 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-20dBBandwidth ConditionModeFrequency(MHz)Antenna-20dBBandwidth(MHz)Limit-20dBBandwidth(MHz)Verdict NVNT1-DH52402Ant11.016N/APass NVNT1-DH52441Ant10.941N/APass NVNT1-DH52480Ant10.943N/APass NVNT2-DH52402Ant11.317N/APass NVNT2-DH52441Ant11.285N/APass NVNT2-DH52480Ant11.281N/APass Page 3 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page 5 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page 6 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaTotalPower (dBm) Limit(dBm)Verdict NVNT1-DH52402Ant1-0.1521Pass NVNT1-DH52441Ant1-0.3221Pass NVNT1-DH52480Ant10.2121Pass NVNT2-DH52402Ant10.1921Pass NVNT2-DH52441Ant10.8521Pass NVNT2-DH52480Ant1-0.3621Pass Page 7 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 8 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page 9 of 42 FCCID:2BLAA-FE-4601ReportNo.:LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page 10 of 42 FCCID:2BLAA-FE-4601ReportNo.: LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1(MHz)HoppingFreq2(MHz)HFS(MHz)Limit(MHz)Verdict NVNT1-DH5Ant12401.822403.0241.2040.677Pass NVNT2-DH5Ant12402.022403.1541.1340.878Pass Page 11 of 42 FCCID:2BLAA-FE-4601ReportNo.: LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs CFSNVNT1-DH52402MHzAnt1 CFSNVNT2-DH52402MHzAnt1 Page 12 of 42 FCCID:2BLAA-FE-4601ReportNo.: LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.4DwellTime ConditionModeFrequency (MHz) AntennaPulseTime (ms) TotalDwellTime (ms) Burst Count PeriodTime (ms) Limit (ms) Verdict NVNT1-DH52402Ant12.91279.369631600400Pass NVNT2-DH52402Ant12.898330.37211431600400Pass Page 13 of 42 FCCID:2BLAA-FE-4601ReportNo.: LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs DwellNVNT1-DH52402MHzAnt1OneBurst DwellNVNT1-DH52402MHzAnt1Accumulated Page 14 of 42 FCCID:2BLAA-FE-4601ReportNo.: LCSA09034142EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2BLAA-FE-4601 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3

Contact Information

Applicant

Ya Ting Fang
[email protected]15985815020Fax: 0086-592-5360446

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.