2BLCJ-DH773 in 1 wireless charger

Dongguan Dingdian Electronic Technology Co., Ltd.
3 in 1 wireless charger - FCC ID 2BLCJ-DH77 - Dongguan Dingdian Electronic Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Oct 08, 2024
Application Purpose
Original Equipment
Date of Application
Oct 08, 2024
Equipment Note
3 in 1 wireless charger
Frequency Range
0.30000000 - 0.35000000
Company
Dongguan Dingdian Electronic Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

Dongguan Dingdian Electronic Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/26/2024 U.S. Agent Designation Don gguan Dingdian Electronic Technology Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BLCJ-DH77): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Dongguan Dingdian Electronic Technology Co., Ltd.. Dongguan Dingdian Electronic Technology Co., Ltd. with the FRN 0035992619 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature Jianping Zou Corporation Dongguan Dingdian Electronic Technology Co., Ltd. Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BLCJ-DH77 DH77 We, Applicant Company Name: Dongguan Dingdian Electronic Technology Co., Ltd. Address: Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Phone: +86-15079468964 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-26 Signature Date Name / Title: Jianping Zou / Corporation Company: Dongguan Dingdian Electronic Technology Co., Ltd. Address: Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Phone: +86-15079468964 Fax: +86-15079468964 Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BLCJ-DH77 DH77 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2024-09-26 Signature Date Name / Title: Jianping Zou / Corporation Company: Dongguan Dingdian Electronic Technology Co., Ltd. Address: Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Phone: +86-15079468964 Fax: +86-15079468964 Email: [email protected]

Cover Letter(s)

Dongguan Dingdian Electronic Technology Co., Ltd. Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Date: September 26, 2024 FCC ID: 2BLCJ-DH77 Model Number: DH77 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Dongguan Dingdian Electronic Technology Co., Ltd. hereby declare that our product (3 in 1 wireless charger) Model Number: DH77 meet item 5.2 of KDB 680106v03r01 as follow; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operates in the frequency range 110 KHz - 205 KHz (Charge Phone and AirPods), 300-350KHz (Charge Watch) The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. Yes Charge Phone: The maximum output power of the primary coil is 15W. Charge Watch The maximum output power of the primary coil is 2.5W. Charge AirPods: The maximum output power of the primary coil is 3W A client device providing the maximum permitted load is placed in physical contact with the transmitter (i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact) Yes Client device is placed directly in contact with the transmitter. Only § 2.1091- Mobile exposure conditions apply (i.e., this provision does not cover § 2.1093-Portable exposure conditions). Yes Mobile exposure conditions only The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% Yes The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top Dongguan Dingdian Electronic Technology Co., Ltd. Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China of the applicable MPE limit, per KDB 447498, Table 1. These measurements shall be taken along the principal axes of the device, with one axis oriented along the direction of the estimated maximum field strength, and for three points per axis or until a 1/d (inverse distance from the emitter structure) field strength decay is observed. Symmetry considerations may be used for test reduction purposes. The device shall be operated in documented worst-case compliance scenarios (i.e., the ones that lead to the maximum field components), and while all the radiating structures (e.g., coils or antennas) that by design can simultaneously transmit are energized at their nominal maximum power. surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. For systems with more than one radiating structure, the conditions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing maximum power available), and with all the radiating structures operating at maximum power at the same time, as per design conditions. If the design allows one or more radiating structures to be powered at a higher level while other radiating structures are not powered, then those cases must be tested as well. For instance, a device may use three RF coils powered at 5 W, or one coil powered at 15 W: in this case, both scenarios shall be tested Yes Only one radiating structure and tested at maximum Output Power Please contact me if you have any question. Dongguan Dingdian Electronic Technology Co., Ltd. Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Sincerely, (Signed) Name/Title: Jianping Zou / Corporation Company: Dongguan Dingdian Electronic Technology Co., Ltd. Address: Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province 523695, China Tel: +86-15079468964 Fax: +86-15079468964 E-Mail: [email protected]

External Photos

Page 1 of 5 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9

ID Label/Location Info

Page 1 of 1 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 4.0cm x W 3.5cm) Label Location 3 in 1 wireless charger Model: DH77 FCC ID: 2BLCJ-DH77

Internal Photos

Page 1 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Coil Antenna 2 Page 4 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Coil Antenna 3 Coil Antenna 1 Page 8 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18 Page 10 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 19 Fig. 20 Page 11 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 21 Fig. 22 Page 12 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 23 Fig. 24 Page 13 of 13 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 25

RF Exposure Info

Page 1 of 17 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information Applicant Dongguan Dingdian Electronic Technology Co., Ltd. Address Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province, China FCC ID: 2BLCJ-DH77 Product Name 3 in 1 wireless charger Model Number DH77 Power Supply Input: 5V3A, 9V2A, 12V1.5A Output: 15W/10W/7.5W/5W Watch Output: 2.5W Headphone Output: 3W Modulation Type ASK Frequency Range Coil1: For Phone: 110.0~205kHz Coil2: For Earphone: 110.0~205kHz Coil3: Watch: 300~350kHz Antenna Type Coil Antenna Hardware version / Software version / Accessories Phone*1, Apple Watch*1, AirPods*1 Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Wireless power transfer devices must comply with RF exposure requirements for all design configurations in which they can operate. At a minimum, RF exposure must be evaluated for the worst-case scenario, typically when the transmitter, while delivering energy to a client device, is operating at maximum output power. RF exposure compliance for equipment authorization must be determined following the guidance of KDB447498, which includes consideration of the different test requirements for Mobile Device and Portable Device exposure categories, as defined in §§ 2.1091 and 2.1093 of the Rules. 2) The RF exposure limits, as set forth in § 1.1310, do not cover the frequency range below 100 kHz for Specific Absorption Rate (SAR) and below 300 kHz for Maximum Permitted Exposure (MPE). In addition, present limitations of RF exposure evaluation systems prevent an accurate evaluation of SAR below 4 MHz. For these reasons, a specific MPE-based RF Exposure compliance procedure for devices operating in the aforementioned low-frequency ranges has been set in place. This procedure is applicable to Equipment Authorization of all RF devices, thus including, but not limited to, Part 18 and WPT devices. Accordingly, for § 2.1091-Mobile devices, the MPE limits between 100 kHz to 300 kHz are to be considered the same as those at 300 kHz in Table 1 of § 1.1310, that is, 614 V/m and 1.63 A/m, for the electric field and magnetic field, respectively. For § 2.1093-Portable devices below 4 MHz and down to 100 kHz, the MPE limits in § 1.1310 (with the 300 kHz limit applicable all the way down to 100 kHz) can be used for Page 2 of 17 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity the purpose of equipment authorization in lieu of SAR evaluations. Furthermore, consistent with FCC’s equipment authorization RF exposure guidance, any device (both portable and mobile) operating at frequencies below 100 kHz is considered compliant for the purpose of equipment authorization when the external (unperturbed) temporal peak field strengths do not exceed the following reference levels: 83 V/m for the electric field strength (E) and 90 A/m for the magnetic field strength (H) These data may be provided through measurements and/or numerical simulations, and for all the positions in space relevant for any possible body exposure. 3) “Large size” probes may prevent the measurement of E- and/or H-fields near the surface of the radiating structure (e.g., a WPT source coil), as in the example shown in Figure 1. If the center of the probe sensing element is located more than 5 mm from the probe outer surface, the field strengths need to be estimated through modeling for those positions that are not reachable. The estimates may be done either via numerical calculation, or via analytic model: e.g., approximated formulas for circular coils, dipoles, etc., may be acceptable if it is shown that the model is applicable for the design parameters considered. A typical example is the use of a quasi-static approximation formula for a low-frequency magnetic field source. These estimates shall include points spaced no more than 2 cm from each other. Thus, in the example of Figure 1, at least the estimates at 0 cm2 and 2 cm are required, while only one point would not be sufficient. In addition, the model needs to be validated through the probe measurements for the two closest points to the device surface, and with 2-cm increments, as indicated in Figure 1. In that example, the same model must also be applied to the 4 cm and 6 cm positions, and then compared with the measured data, for validation purposes. The validation is considered sufficient if a 30% agreement between the model and the (E- and/or H-field) probe measurements is demonstrated. If such a level of agreement cannot be shown, a more accurate model (and/or a smaller probe) shall be used. 4) Part 18 Wireless Power Transfer up to One-Meter Distance. This section applies only to WPT transmitters that, by design, can provide power to a load located at a distance no greater than one meter. This distance shall be measured between the closest points between the transmitter and the receiver enclosure surfaces. For instance, two coils positioned as in Figure 2-a may be operated and considered under the provisions of this section, because both receivers are within one-meter distance from the transmitter. However, the case in Figure 2-b cannot be considered Page 3 of 17 FCC ID: 2BLCJ-DH77 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Sh…

Text truncated - open the document above for the full version.

Test Report

1.外观标准:/1. Appearance standard: c) PCB颜色: 绿油白字 /c) PCB color: green oil white characters . Shenzhen Yongman digital Co., LTD Product specification for Phone PRODCT SPECIFICATION FOR APPROVAL CUSTOMER/客户名称: Type of product ion/产品类别: 无线快充座/Wireless fast charging seat 。 Customer 'S PART NO 客户型号: 。 Mode No:机种名称 : YM-X455-V0.3 。 Date:/制订日期:2023/07/31 。 Edition: 版本:V0.3 。 CUSTOMER ADMIT/客户承认 Design By: 拟定Check. By:/检查Auditing:/审查 a) PCBA焊接要求符合 IPC-A-610-E ;/a) PCBA welding requirements meet IPC-A-610-E; 特殊要求(按客户要求执行)/Special requirements (as required by customer) b) PCB表面丝印标识:/b) Screen printing on PCB surface: 开发商(或制造商)标识: YM / Developer (or manufacturer) ID: YM . 客户型号:/Customer Model:. . PCB版本/PCB version: YM-X455-V0.3 . PCB设计日期/PCB design date 2023/07/22 . d) PCB接口板材:FR4 /d) PCB interface board: FR4 e) 板 厚/e) Plate thickness: 0.9MM-1.1MM 2nd Floor, Building 1, Tiantong Industrial Park, Gaofeng Community, Dalang Street, Longhua District, Shenzhen, China 序号 /Serial number 类别 /category测试标准/Test standard 测试条件/Test condition 1 2 带FOD 功能/With FOD function 1块硬币大小可以检测/1 coin size can be detected 蓝灯闪/Blue light flash 3 输入电压/Input voltage 9V 支持QC2.0/QC3.0/PD QC2.0/QC3.0/PD is supported 4 输入电流/Input current 9V/2A 5 输出电流/Output current 9V/1.66A 6 输入电压/Input voltage 9V 7 输入电流/Input current 9V1.65A 8 输出电流/Output current 9V1.1A 9 输入电压/Input voltage 5V 10 输入电流/Input current 5V/1.5A 11 输出电流/Output current 5V/1.0A 12 无线充适合距离/Wireless charging is suitable for distance 2MM-6MM 最好2MM Preferably 2MM 13 无线充效率/Wireless charging efficiency 70-75% 14 蓝灯常亮 15 蓝灯呼吸亮 16 17 2.电性能标准:/2. Electrical performance standard: 符合 QI1.2 标准,兼容所有 QI 无线充电设备/Comply with QI1.2 standard, compatible with all QI wireless charging devices 无 线 充 性 能/Linear charge energy LED灯显示 性能/LED lights display performance 15W无线充 /15W wireless charge 10W无线充 /10W wireless charge 5W无线充/5W wireless charge 电性能项目/Electrical performance item 空载/unloaded 带载/on-load 3.PCB图档/3. PCB drawing file 3.2 TOP layer 3.3 BOTTOM layer 3.1 PCB尺寸图:PCB长宽公差正负:0.15MM,厚度:1.0MM+/—0.13MM 3.1 PCB size diagram: PCB length and width tolerance: 0.15MM, thickness: 1.0MM+/ - 0.13MM 4.环保要求:根据客户要求环保 4. Environmental protection requirements: Environmental protection according to customer requirements 4.PCBA图片/4.PCBA picture PCBA正面图 PCDA反面图 5.线/5.Coil Size (Unit: mm) 90.0±1.5 We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required. 1.CONSTRUCTION DIMENSION(UNIT:mm) Product Name 无线充发射线圈 DRAWING NO NSDKS A11-6.5UH-001 DOC TYPE AA版 SPECIFICATION FOR TWS Coil PART NO A11-6.5UH-001 MODEL A11 内径Φ20.5*Φ42 Φ 0.08*105P丝包线*10TS Φ50*Φ5.3*T1.0 感量6.5UH 引 线长60.0mm REV AA版 ■REMARK:1.D为磁片外引线长度;2.J不包含进线; Shenzhen Yongman digital Co., LTD 2nd Floor, Building 1, Tiantong Industrial Park, Gaofeng Community, Dalang Street, Longhua District, Shenzhen, China We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required. 客 户 /C l ient 名称 /TYPE 发射线圈 44MM (环保状况: RoHS+HF ) 产品型号 Model NO SG - A1144 - 6.6UH 产品编号 SG - A11 - 030 Part nunbering systey 客户料号 C l ient p/NO 工程编号 Enginrer NO TQE 1800510003 日期 /Date 2021 - 10 - 9 编制/Prepared 审核/Checked 认可/Approved DuanJiaWang XieLiang XieXiaoZai 客户认可回签/Authorixed Signaturure Company Chop 工程/ Enginrer 认可/QC APProved 认可日期/APProved 一、 线圈工艺/Winding Procese: NO 绕组 线规 匝数 绕线方向 备注 本公司工程部/For Enginer Departner Only 修改内容/Rrvised Content 认可日期/APProved Date Guangdong Pingfa Technology Co., Ltd. 4th Floor, Jingxing Factory, Xiangfeng Street, Yangwu First Industrial Zone, Dalingshan Town, Dongguan City, Guangdong, China SPECIFICATION FOR Watch Coil 1 N1 2UEW-B-0.08*24P*2 10TS CCW 2 二.电气性能/FEATURES: 1.测试条件(Test conditions):25°C,65%RH@100KHz/1V 1.1 电感量(Inductance) 1.11 L0A(单独线圈)=3.8uH±20% 1.12 L0A(线圈+磁片)=6.3uH±10% 1.2 Q值=70MIN 1.3 直流电阻(DCR):55mΩ MAX 1.4 工作温度(Operating Temperature):-25°C~85°C 2.测试仪器(Test instrument):L:创达1068+1310;DCR:502BC;SIZE:Callipers 3.材料清单/ Bill of materials NO item Materials 1 WIRE ¢0.08*24p*2 2UEW-1.0mm 2 FERRITE 43.5*4.7* 0.8L double slot ferrite hard magnetic 3 GLUE White glue 4 SOLDER XCD-907B 5 Adhesive Double-sided adhesive 6 High temperature adhesive 8MM high temperature tape 7 8 Guangdong Pingfa Technology Co., Ltd. 4th Floor, Jingxing Factory, Xiangfeng Street, Yangwu First Industrial Zone, Dalingshan Town, Dongguan City, Guangdong, China 三.电路图/CIRCUIT DIAGRAM 单位: MM 四.外形图/OUTSIDE DIAGRA Note: Wrap 8MM (ref) high temperature adhesive paper around coil outlet position 注:线圈出线位置缠绕8MM(ref)高温胶纸 标准 A B C D E F I T STD 43.5±1 20.5±0.5 4.7±0.5 30±2 2-5 39±1.2 0.8±0.2 1.6Max unit单位: MM We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required. Guangdong Pingfa Technology Co., Ltd. 4th Floor, Jingxing Factory, Xiangfeng Street, Yangwu First Industrial Zone, Dalingshan Town, Dongguan City, Guangdong, China 五.包装/PACKAGE 5.3包装以现有包装盘为参照标准,以实际出货包装为准,如有特需要求可以定制。 The packaging shall be based on the exusting packing plate and the actual delivery package shall prevail .If there is any requirement,we can customize it. 1400 Guangdong Pingfa Technology Co., Ltd. 4th Floor, Jingxing Factory, Xiangfeng Street, Yangwu First Industrial Zone, Dalingshan Town, Dongguan City, Guangdong, China 六、贮存和使用条件 Storage and Use condition 6.1 贮存条件 Storage condition 6.1.1 建议贮存条件:温度-25°C~ 85°C ,湿度70% (Max.) Recommended keeping conditions: -25°C ~85°C, 70%RH (Max.) 6.1.2 贮存期限:自生产之日起六个月内 Storage life : Within the limits of six months from being produced. 6.2 使用条件 Use condition 使用条件限制:温度=-25°C~ 85°C, 湿度≤ 90% Use condition limit: T=-25°C~85°C, RH≤ 90%. Guangdong Pingfa Technology Co., Ltd. 4th Floor, Jingxing Factory, Xiangfeng Street, Yangwu First Industrial Zone, Dalingshan Town, Dongguan City, Guangdong, China

Test Report

Page 1 of 25 FCC ID: 2BLCJ-DH77 Report No.: LCSA09124040EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Dongguan Dingdian Electronic Technology Co., Ltd. 3 in 1 wireless charger Test Model: DH77 Prepared for : Dongguan Dingdian Electronic Technology Co., Ltd. Address : Room 502, Chengfeng Building, No. 22 Fengyuan Road, Fenggang Town, Dongguan City, Guangdong Province, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 13, 2024 Number of tested samples : 2 Serial number : A240912039-1(Engineer sample), A240912039-2(Normal sample) Date of Test : September 13, 2024 ~ September 19, 2024 Date of Report : September 20, 2024 Page 2 of 25 FCC ID: 2BLCJ-DH77 Report No.: LCSA09124040EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: webma…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jianping Zou
[email protected]15079468964Fax: 15079468964

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C0.3 MHz - 0.35 MHz-
Confidentiality
Long Term