Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
DRDLLC 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:DRDLLC Address:5016SchusterSt.LasVegasNV88901UnitedStatesOfAmerica ProductName:ElectricalApparatus FCCID:2BLGBSWITCHGO Model(s):SwitchGO 2.911(d)(5)(i)EquipmentType We,[DRDLLC](“theapplicant”)certifythattheequipmentforwhichauthorizationissoughtthrough certificationisnot:  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:LinaZhuDate:2026-2-28 TitleandCompanyname:GeneralManager/DRDLLC NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
DRDLLC 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:DRDLLC Address:5016SchusterSt.LasVegasNV88901UnitedStatesOfAmerica ProductName:ElectricalApparatus FCCID:2BLGBSWITCHGO Model(s):SwitchGO 2.911(d)(5)(ii)Applicantfiling We,[DRDLLC](“theapplicant”)certifythat,asofthedateofthefilingoftheapplication,the applicantisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto§1.50002of thischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:LinaZhuDate:2026-2-28 TitleandCompanyname:GeneralManager/DRDLLC NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
DRDLLC OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-2-28 Subject;RequestforConfidentiality FCCID:2BLGBSWITCHGO ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:LinaZhu Title:GeneralManager
DRDLLC LetterofAuthorization Company:DRDLLC Address:5016SchusterSt.LasVegasNV88901UnitedStatesOfAmerica ProductName:ElectricalApparatus ModelNumber(s):SwitchGO ProductDescription:ElectricalApparatus FCCID:2BLGBSWITCHGO WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date: 2026-2-28 Name:LinaZhu Title:GeneralManager Company:DRDLLC
Page1of1FCCID:2BLGBSWITCHGO ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:2.0cmxW:1.0cm) LabelLocation ElectricalApparatus Model:SwitchGO FCCID:2BLGBSWITCHGO
Page1of9FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation For DRDLLC ElectricalApparatus TestModel:SwitchGO Preparedfor:DRDLLC Address:5016SchusterStLasVegas,NV89118USA Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:January21,2026 Numberoftestedsamples:2 SampleNo.:A260120052-1,A260120052-2 Serialnumber:Prototype DateofTest:January21,2026~February03,2026 DateofReport:February04,2026 Page2of9FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation ReportReferenceNo......................:LCSA01196155EB DateofIssue.......................................:February04,2026 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocationProcedure.............:FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:DRDLLC Address................................................:5016SchusterStLasVegas,NV89118USA TestSpecification Standard..............................................: FCCKDBpublication447498D01GeneralRFExposureGuidance v06 FCCCFR47part11.1310 FCCCFR47part22.1093 TestReportFormNo......................:TRF-4-E-215A0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:ElectricalApparatus TradeMark..........................................: TestModel...........................................:SwitchGO Ratings.................................................:PleaseRefertoPage6 Result..................................................:PASS Compiledby:Supervisedby:Approvedby: NickPeng/AdministratorsKevinHuang/RFManagerGavinLiang/Manager Page3of9FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation TestModel..........................:SwitchGO EUT....................................:ElectricalApparatus Applicant...........................:DRDLLC Address..............................:5016SchusterStLasVegas,NV89118USA Telephone..........................:/ Fax.....................................:/ : Manufacturer.....................:FOCUSHI-TECHCO.,LTD Address..............................:BuildingC,JingfukangIndustrialzone,FengHuangRoad No.9,Torchdevelopmentdistrict,Zhongshan,China, 528437 Telephone..........................:/ Fax.....................................:/ : Factory..............................:FOCUSHI-TECHCO.,LTD Address..............................:BuildingC,JingfukangIndustrialzone,FengHuangRoad No.9,Torchdevelopmentdistrict,Zhongshan,China, 528437 Telephone..........................:/ Fax.....................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA01196155EB February04,2026 Dateofissue Page4of9FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000February04,2026InitialIssue-- Page5of9FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.PRODUCTINFORMATION....................................................................................................................................6 2.EVALUATIONMETHODANDLIMIT....................................................................................................................7 3.REFEREVALUATIONMETHOD..........................................................................................................................8 4.CONDUCTEDPOWERRESULTS........................................................................................................................8 5.MANUFACTURINGTOLERANCE........................................................................................................................8 6.EVALUATIONRESU…
Text truncated - open the document above for the full version.
Page 1 of 37 FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For DRDLLC ElectricalApparatus TestModel:SwitchGO Preparedfor:DRDLLC Address:5016SchusterStLasVegas,NV89118USA Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:January21,2026 Numberoftestedsamples:2 SampleNo.:A260120052-1,A260120052-2 Serialnumber:Prototype DateofTest:January21,2026~February03,2026 DateofReport:February04,2026 Page 2 of 37 FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA01196155EA DateofIssue.......................................:February04,2026 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:DRDLLC Address................................................:5016SchusterStLasVegas,NV89118USA TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo......................:TRF-4-E-145A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:ElectricalApparatus TradeMark..........................................: TestModel...........................................:SwitchGO Ratings.................................................:PleaseRefertoPage6 Result..................................................:PASS Compiledby:Supervisedby:Approvedby: NickPeng/AdministratorsKevinHuang/RFManagerGavinLiang/Manager Page 3 of 37 FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestModel...............................:SwitchGO EUT.........................................:ElectricalApparatus Applicant...............................:DRDLLC Address..................................:5016SchusterStLasVegas,NV89118USA Telephone...............................:/ Fax..........................................:/ Manufacturer........................:FOCUSHI-TECHCO.,LTD Address...................................:BuildingC,JingfukangIndustrialzone,FengHuangRoadNo.9, Torchdevelopmentdistrict,Zhongshan,China,528437 Telephone...............................: Fax..........................................: Factory...................................:FOCUSHI-TECHCO.,LTD Address...................................:BuildingC,JingfukangIndustrialzone,FengHuangRoadNo.9, Torchdevelopmentdistrict,Zhongshan,China,528437 Telephone...............................:/ Fax..........................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA01196155EA February04,2026 Dateofissue Page 4 of 37 FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000February04,2026InitialIssue--- Page 5 of 37 FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)........................................................................................................................6 1.2.SUPPORTEQUIPMENTLIST.................................................................................................................................7 1.3.EXTERNALI/OCABLE..........................................................................................................................................7 1.4.DESCRIPTIONOFTESTFACILITY......................................................................................................…
Text truncated - open the document above for the full version.
PB-03FSpecificationV1.0.0 Antennaparameters Testconditionsfortheantenna Figure7Antennatestconditions Copyright©2021ShenzhenAi-ThinkerTechnologyCo.,LtdAllRightsReserved Page12of22 PB-03FSpecificationV1.0.0 AntennaSparameter Figure8AntennaSparameters AntennaGainandEfficiency Table7AntennaGainandefficiency FrequencyID1234567891011 Frequency(MHz)2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 Gain(dBi)1.991.842.151.681.701.521.381.451.781.471.62 Efficiency(%)77.7676.1481.0873.6074.8071.8968.9269.5572.8366.5369.30 Copyright©2021ShenzhenAi-ThinkerTechnologyCo.,LtdAllRightsReservedPage13of22 PB-03FSpecificationV1.0.0 Antennafieldtypediagram Figure9Antennafieldtypediagram
Page1of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBTLE(ConductedMeasurement) ProductName:ElectricalApparatus TestModel:GSeries EnvironmentalConditions Temperature: 24.2  C RelativeHumidity:53.5% ATMPressure:100.0kPa TestEngineer:JerryChu Supervisedby:CanKun Page2of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.64870.5Pass NVNTBLE1M2440Ant10.65450.5Pass NVNTBLE1M2480Ant10.65870.5Pass NVNTBLE2M2402Ant11.1620.5Pass NVNTBLE2M2440Ant11.1780.5Pass NVNTBLE2M2480Ant11.1320.5Pass Page3of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 Page4of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 Page5of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 Page6of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConducted Power(dBm) Limit Conducted(dBm) Verdict NVNTBLE1M2402Ant1-2.6630Pass NVNTBLE1M2440Ant1-0.1930Pass NVNTBLE1M2480Ant1-1.1530Pass NVNTBLE2M2402Ant1-2.7630Pass NVNTBLE2M2440Ant1-0.3130Pass NVNTBLE2M2480Ant1-1.2930Pass Page7of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 Page8of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 Page9of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 Page10of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-19.458Pass NVNTBLE1M2440Ant1-16.688Pass NVNTBLE1M2480Ant1-17.68Pass NVNTBLE2M2402Ant1-22.448Pass NVNTBLE2M2440Ant1-19.728Pass NVNTBLE2M2480Ant1-20.858Pass Page11of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 Page12of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 Page13of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 Page14of34FCCID:2BLGBSWITCHGOReportNo.:LCSA01196155EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.4BandEdge ConditionModeFrequency(MHz)AntennaMaxV…
Text truncated - open the document above for the full version.
1408 Pinon Place Fullerton, CA 92835 United States · California, 92835 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 960.00 µW |