FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Meifu Electronics Co., Ltd/
  3. 2BLJ8-ML701D

2BLJ8-ML701DSmart Body Scale

Shenzhen Meifu Electronics Co., Ltd

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 14, 2024
Application Purpose
Original Equipment
Date of Application
Oct 14, 2024
Equipment Note
Smart Body Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Meifu Electronics Co., Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

LABEL: Ca: 5mm x 20mm Label Location FCC ID: 2BLJ8-ML701D

RF Exposure Info

FCC RF Exposure Product Name: Smart Body Scale FCC ID: 2BLJ8‐ML701D Model(s): ML701D 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√ f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation Frequency (MHz) Output power (dBm) Tune Up Power (dBm) Max Tune Up power dBm/mW Min test separatio n distance mm Result Limit (mW/cm 2 ) SAR Test Exclusion 2402 ‐0.63 0±1 1/1.26 5 0.39 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2409245520‐E, antenna gain=‐0.58dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.39 which is<= 3, RF Exposure testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f (GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm

Test Report

Inverted F Antenna Specification ITEMANT SPEC Model NamePASSIVE2.4G Center Frequency HorizontalVertical 2400MHz 2450MHz 2500MHz2400MHz 2450MHz 2500MHz -1.26-0.76-0.58-5.25-2.46-1.86 MAX. Gain - 0.58dB PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length38.20mm ManufactureLANXUN TECHNOLOGY CO.,LTD Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div

Test Report

Page 1 of 41 Report No.: HK2409245520-E FCC Test Report Test Report On Behalf of Shenzhen Meifu Electronics Co., Ltd For Smart Body Scale Model No.: ML701D, FG2019LB-F, ML702C, ML703C, ML705C, ML818C, ML828C, ML838C, ML858C, ML868C FCC ID: 2BLJ8-ML701D Prepared For: Shenzhen Meifu Electronics Co., Ltd 101, Building C1, No.12 Jiaye Road, Hehua Community, Pinghu Street, Longgang District, Shenzhen, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Sep. 23, 2024 ~ Sep. 30, 2024 Date of Report: Sep. 30, 2024 Report Number: HK2409245520-E Page 2 of 41 Report No.: HK2409245520-E Test Result Certification Applicant’s Name ................... : Shenzhen Meifu Electronics Co., Ltd Address .................................... : 101, Building C1, No.12 Jiaye Road, Hehua Community, Pinghu Street, Longgang District, Shenzhen, China Manufacturer's Name ............. : Shenzhen Meifu Electronics Co., Ltd Address .................................... : 101, Building C1, No.12 Jiaye Road, Hehua Community, Pinghu Street, Longgang District, Shenzhen, China Product Description Trade Mark ................................. : Meilen Product Name ............................ : Smart Body Scale Model and/or Type Reference .. : ML701D, FG2019LB-F, ML702C, ML703C, ML705C, ML818C, ML828C, ML838C, ML858C, ML868C Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of Performance of Tests ............... : Sep. 23, 2024 ~ Sep. 30, 2024 Date of Issue ............................................. : Sep. 30, 2024 Test Result ................................................. : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 41 Report No.: HK2409245520-E Contents Page 1 Test Summary ................................................................................................................................................ 5 1.1 Test Description ......................................................................................................................................... 5 1.2 Measurement Uncertainty ......................................................................................................................... 6 1.3 Information of the Test Laboratory ............................................................................................................ 6 2 General Information ....................................................................................................................................... 7 2.1 General Description of EUT ...................................................................................................................... 7 2.2 Description of Test Conditions .................................................................................................................. 9 2.3 Description of Test Setup ........................................................................................................................ 10 2.4 Description of Support Units .................................................................................................................... 11 3 Equipments List for All Test Items ............................................................................................................. 12 4 Test Result .................................................................................................................................................... 13 4.1 Antenna Requirement.............................................................................................................................. 13 4.2 Conduction Emissions Measurement ...................................................................................................... 14 4.3 Radiated Emissions Measurement .......................................................................................................... 17 4.4 Maximum Output Power Measurement ................................................................................................... 26 4.5 Power Spectral Density ........................................................................................................................... 27 4.6 6dB Bandwidth ........................................................................................................................................ 30 4.7 Occupied Bandwidth ................................................................................................................................ 33 4.8 Band Edge ............................................................................................................................................... 34 4.9 Conducted Spurious Emissions .............................................................................................................. 36 5 Test Setup Photos ....................................................................................................................................... 40 6 Photos of the EUT ........................................................................................................................................ 41 Page 4 of 41 Report No.: HK2409245520-E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Sep. 30, 2024 Jas…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Yu(Manager)
[email protected]13544081840Fax: 075584002869

Technical Contact

Shenzhen Meifu Electronics Co., Ltd
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz860.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.