Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Zecre Technology CO.,Ltd 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Zecre Technology CO.,Ltd Address: RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Product Name: Trail Camera FCC ID: 2BLWP-960S Model(s): PH960S, PH980W, PH980S 2.911(d)(5)(i) Equipment Type We, [Shenzhen Zecre Technology CO.,Ltd] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: jinguang Xu Date: Aug. 28, 2025 Signature: Title and Company name: R & D manager / Shenzhen Zecre Technology CO.,Ltd NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Shenzhen Zecre Technology CO.,Ltd 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Zecre Technology CO.,Ltd Address: RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Product Name: Trail Camera FCC ID: 2BLWP-960S Model(s): PH960S, PH980W, PH980S 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Zecre Technology CO.,Ltd] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to §1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: jinguang Xu Date: Aug. 28, 2025 Signature: Title and Company name: R & D manager / Shenzhen Zecre Technology CO.,Ltd NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhenZecreTechnologyCO.,Ltd 2.911(d)(7)USAAgentv1.4 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:ShenzhenZecreTechnologyCO.,Ltd Address:RM501BLDGBAREACSHANGXUEINDUSTRIALPARK,XINXUE COMMUNITY,BANTIAN,LONGGANG,SHENZHEN,CHINA ProductName:TrailCamera FCCID:2BLWP-960S Model(s):PH960S,PH980W,PH980S 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ShenzhenZecreTechnologyCO.,Ltd](“theapplicant”)designate[TRANS-PAC CHINALLC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfofthe applicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. ShenzhenZecreTechnologyCO.,Ltd 2.911(d)(7)USAAgentv1.4 USAAgent Companyname: TRANS-PACCHINALLC Address: 3715S182ndStreet,C120Seatac,WA 98188UnitedStates FCCRegistrationNumber(FRN): 0036394526 ContactName:LisaLee TelephoneNo:+18188180538 Email:[email protected] Applicant Companyname:ShenzhenZecre TechnologyCO.,Ltd Address:RM501BLDGBAREAC SHANGXUEINDUSTRIALPARK,XINXUE COMMUNITY,BANTIAN,LONGGANG, SHENZHEN,CHINA FCCGranteeCode:2BLWP FRNNumber:0036196731 ContactName:jinguangXu TelephoneNo:18675794321 Email:[email protected] Signature: Title: Signature: Title:R&Dmanager Date:Aug.29,2025Date:Aug.29,2025 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
Shenzhen Zecre Technology CO.,Ltd Agent Authorization Company: Shenzhen Zecre Technology CO.,Ltd Address: RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, China Product Name: Trail Camera Model Number(s): PH960S, PH980W, PH980S Product Description: Trail Camera We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Aug. 28, 2025 Name: jinguang Xu Title: R & D manager Company: Shenzhen Zecre Technology CO.,Ltd
Shenzhen Zecre Technology CO.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Aug. 28, 2025 Subject; Request for Confidentiality FCC ID: 2BLWP-960S To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software security requirement In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: jinguang Xu Title: R & D manager
Shenzhen Zecre Technology CO.,Ltd Model Difference Declaration To Whom It May Concern, We, Shenzhen Zecre Technology CO.,Ltd (Trail Camera); Trade Mark: N/A, Model Number: PH960S, PH980W, PH980S; All model's the function, software and electric circuit are the same, only with product color and model named different. Test sample model: PH960S Please contact me if you have any question. Si gnature: Date: Aug. 28, 2025 Name: jinguang Xu Title: R & D manager
FCC ID LABEL: Ca. 10mm x 40mm Label Location FCC ID: 2BLWP-960S
MPE ESTIMATION FCC ID: 2BLWP-960S 1,Per FCC Part 2.1091 Radiofrequency radiation exposure evaluation: mobile devices, the limit for General Population/ Uncontrolled Exposures Frequency Power density (mW/ cm 2 ) Averaging time(minutes) 300MHz----1.5GHz F/1500 30 1.5GHz---100GHz 1.0 30 Note: F= Frequency in MHz 2, Estimation Result When the minimum test separation distance is >20 cm, a distance of 20 cm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.01611 mW/cm² which is< 1.0mW/cm², RF Exposure testing is not required. -------The End------- Mode Frequency (MHz) Max PK Output power(dBm) Tune Up Power(dBm) Max Tune Up power(mW) Antenna Gain(dBi) Antenna Gain (linear) MPE (mW/cm²) 2.4g WIFI 2462 14.54 14±1(15) 31.62 3.93 2.47 0.01555 BLE 2440 1.14 1±1(2) 1.58 2.49 1.77 0.00056 Note: Note: The estimation distance is 20cm Note: PK Output power= conducted power in mW. G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna in cm Conducted power see the test report HK2507304199-1E/2E , antenna gain=3.93dBi(2.4g WIFI), 2.49dBi(BLE) BLE MPE (max)=0.00056 (mW/cm²) 2.4G Wifi (max)= 0.01555 (mW/cm²) simultaneously MPE=0.00056+0.01555=0.01611<1.0
Page 1 of 42 Report No.: HK2507304199-1E FCC Test Report Test report On Behalf of Shenzhen Zecre Technology CO.,Ltd For Trail Camera Model No.: PH960S, PH980W, PH980S FCC ID: 2BLWP-960S Prepared For : Shenzhen Zecre Technology CO.,Ltd RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Jul. 30, 2025 ~ Aug. 13, 2025 Date of Report: Aug. 13, 2025 Report Number: HK2507304199-1E Page 2 of 42 Report No.: HK2507304199-1E Test Result Certification Applicant’s name ................... : Shenzhen Zecre Technology CO.,Ltd Address .................................... : RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Manufacturer's Name ............. : Shenzhen Zecre Technology CO.,Ltd Address .................................... : RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Product description Trade Mark: N/A Product name ............................. : Trail Camera Model and/or type reference .. : PH960S, PH980W, PH980S Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10: 2020 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of performance of tests ................ : Jul. 30, 2025 ~ Aug. 13, 2025 Date of Issue ............................................. : Aug. 13, 2025 Test Result ................................................. : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 42 Report No.: HK2507304199-1E Contents Page 1 Test Summary ................................................................................................................................................ 5 1.1 Test Description ......................................................................................................................................... 5 1.2 Measurement Uncertainty ......................................................................................................................... 6 1.3 Information of the Test Laboratory ............................................................................................................ 6 2 General Information ....................................................................................................................................... 7 2.1 General Description of EUT ...................................................................................................................... 7 2.2 Description of Test Conditions .................................................................................................................. 9 2.3 Description of Test Setup ........................................................................................................................ 10 2.4 Description of Support Units .................................................................................................................... 11 3 Equipments List for All Test Items ............................................................................................................. 12 4 Test Result .................................................................................................................................................... 13 4.1 Antenna Requirement.............................................................................................................................. 13 4.2 AC Power Line Conducted Emission ...................................................................................................... 14 4.3 Radiated Emissions Measurement .......................................................................................................... 18 4.4 Maximum Peak Output Power Measurement ......................................................................................... 27 4.5 Power Spectral Density ........................................................................................................................... 28 4.6 6db Bandwidth ......................................................................................................................................... 31 4.7 Occupied Bandwidth ................................................................................................................................ 33 4.8 Band Edge ............................................................................................................................................... 34 4.9 Conducted Spurious Emissions .............................................................................................................. 36 5 Test Setup Photos of the EUT .................................................................................................................... 40 6 Photos of the EUT ........................................................................................................................................ 42 Page 4 of 42 Report No.: HK2507304199-1E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Aug. 13, 2025 Jason Zhou Page 5 of 42 Report No.: HK2507304199-1E 1 Test Summary 1.1 Test Description Test Item Test Requirement Result Antenna Requirement §15.203/§15.247(b)(4) PASS AC Power Line Conducte…
Text truncated - open the document above for the full version.
Page 1 of 72 Report No.: HK2507304199-2E FCC Test Report Test Report On Behalf of Shenzhen Zecre Technology CO.,Ltd For Trail Camera Model No.: PH960S, PH980W, PH980S FCC ID: 2BLWP-960S Prepared For: Shenzhen Zecre Technology CO.,Ltd RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Jul. 30, 2025 ~ Aug. 13, 2025 Date of Report: Aug. 13, 2025 Report Number: HK2507304199-2E Page 2 of 72 Report No.: HK2507304199-2E Test Result Certification Applicant’s Name .................. : Shenzhen Zecre Technology CO.,Ltd Address .................................. : RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Manufacturer's Name ........... : Shenzhen Zecre Technology CO.,Ltd Address .................................. : RM 501 BLDG B AREA C SHANGXUE INDUSTRIAL PARK, XINXUE COMMUNITY, BANTIAN, LONGGANG, SHENZHEN, CHINA Product Description Trade Mark ............................. : N/A Product Name ......................... : Trail Camera Model and/or Type Reference : PH960S, PH980W, PH980S Standards ............................... : FCC Rules and Regulations Part 15 Subpart C Section 15.247 ANSI C63.10: 2020 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Jul. 30, 2025 ~ Aug. 13, 2025 Date of Issue ........................................... : Aug. 13, 2025 Test Result ............................................... : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 72 Report No.: HK2507304199-2E Table of Contents 1. Test Result Summary ............................................................................... 5 1.1 Test Procedures and Results ........................................................................................................... 5 1.2 Information of the Test Laboratory ................................................................................................. 5 1.3 Measurement Uncertainty ................................................................................................................ 6 2. EUT Description ........................................................................................ 7 2.1 General Description of EUT ............................................................................................................. 7 2.2 Carrier Frequency of Channels ........................................................................................................ 8 2.3 Operation of EUT during Testing ..................................................................................................... 8 2.4 Description of Test Setup ................................................................................................................. 9 3. General Information ................................................................................ 10 3.1 Test Environment and Mode .......................................................................................................... 10 3.2 Description of Support Units ......................................................................................................... 12 4. Test Results and Measurement Data .................................................... 13 4.1 AC Conducted Emission ................................................................................................................ 13 4.2 Test Result ....................................................................................................................................... 15 4.3 Maximum Peak Conducted Output Power .................................................................................... 17 4.4 Emission Bandwidth ....................................................................................................................... 20 4.5 Power Spectral Density .................................................................................................................. 26 4.6 Conducted Band Edge and Spurious Emission Measurement .................................................. 33 4.7 Radiated Spurious Emission Measurement ................................................................................. 43 4.8 Antenna Requirement ..................................................................................................................... 69 5. Photographs of Test ............................................................................... 70 6. Photos of the EUT ................................................................................... 72 Page 4 of 72 Report No.: HK2507304199-2E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Aug. 13, 2025 Jason Zhou Page 5 of 72 Report No.: HK2507304199-2E 1. Test Result Summary 1.1 Test Procedures and Results Requirement CFR 47 Section Result Antenna Requirement §15.203/§15.247(b)(4) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247(b)(3) PASS 6dB Emission Bandwidth §15.247(a)(2) PASS Power Spectral Density §15.247(e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test ob…
Text truncated - open the document above for the full version.
Page 39 of 72 Report No.: HK2507304199-2E 802.11n (HT20) Modulation Lowest Channel Highest Channel Band Edge Band Edge Spurious Emission Spurious Emission Page 40 of 72 Report No.: HK2507304199-2E Middle Channel Spurious Emission Page 41 of 72 Report No.: HK2507304199-2E 802.11n (HT40) Modulation Lowest Channel Highest Channel Band Edge Band Edge Spurious Emission Spurious Emission Page 42 of 72 Report No.: HK2507304199-2E Middle Channel Spurious Emission Page 43 of 72 Report No.: HK2507304199-2E 4.7 Radiated Spurious Emission Measurement Test Specification Test Requirement: FCC Part15 C Section 15.209 Test Method: ANSI C63.10: 2020 Frequency Range: 9 kHz to 25 GHz Measurement Distance: 3 m Antenna Polarization: Horizontal & Vertical Operation Mode: Transmitting mode with modulation Receiver Setup: Frequency Detector RBW VBW Remark 9kHz- 150kHzQuasi-peak200Hz 1kHz Quasi-peak Value 150kHz- 30MHz Quasi-peak9kHz 30kHz Quasi-peak Value 30MHz-1GHzQuasi-peak120KHz300KHz Quasi-peak Value Above 1GHz Peak 1MHz 3MHz Peak Value Peak 1MHz 10Hz Average Value Limit: Frequency Field Strength (microvolts/meter) Measurement Distance (meters) 0.009-0.490 2400/F(KHz) 300 0.490-1.705 24000/F(KHz) 30 1.705-30 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Frequency Field Strength (microvolts/meter) Measurement Distance (meters) Detector Above 1GHz 500 3 Average 5000 3 Peak Test Setup: For radiated emissions below 30MHz Page 44 of 72 Report No.: HK2507304199-2E 30MHz to 1GHz Above 1GHz Test Procedure: 1. For the radiated emission test below 1GHz: The EUT was placed on a turntable with 0.8 meter above ground. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the top of a variable height antenna tower. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high PASS filter are used for the test in order to get better signal level. 2. For the radiated emission test above 1GHz: Place the measurement antenna on a turntable with 1.5 meter above ground, which is away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. Page 45 of 72 Report No.: HK2507304199-2E The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. 3. Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level 4. For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. 5. Use the following spectrum analyzer settings: (1) Span shall wide enough to fully capture the emission being measured; (2) Set RBW=120 kHz for f < 1 GHz; VBW ≥RBW; Sweep = auto; Detector function = peak; Trace = max hold; (3) Set RBW = 1 MHz, VBW= 3MHz for f 1 GHz for peak measurement. 6.For average measurement: VBW = 10 Hz, when duty cycle is no less than 98 percent.VBW ≥ 1/T, when duty cycle is less than 98 percent where T is the minimum transmission duration over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Test Results: PASS Page 46 of 72 Report No.: HK2507304199-2E Test Instruments Radiated Emission Test Site (966) Name of Equipment Manufacturer Model Serial Number Calibration Date Calibration Due Spectrum analyzer Agilent N9020A HKE-025 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer Agilent N9020A HKE-117 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer R&S FSV3044 HKE-126 Feb. 19, 2025 Feb. 18, 2026 Preamplifier EMCI EMC051845SHKE-006 Feb. 19, 2025 Feb. 18, 2026 Preamplifier Schwarzbeck BBV 9743 HKE-016 Feb. 19, 2025 Feb. 18, 2026 Preamplifier A.H. Systems SAS-574 HKE-182 Feb. 19, 2025 Feb. 18, 2026 6dB Attenuator Pasternack 6db HKE-184 Feb. 19, 2025 Feb. 18, 2026 EMI Test Receiver Rohde & Schwarz ESR-7 HKE-010 Feb. 19, 2025 Feb. 18, 2026 Broadband Antenna Schwarzbeck VULB9168 HKE-167 Feb. 21, 2024 Feb. 20, 2026 Loop Antenna COM-POWER AL-130R HKE-014 Feb. 21, 2024 Feb. 20, 2026 Horn Antenna Schewarzbeck 9120D HKE-013 Feb. 21, 2024 Feb. 20, 2026 EMI Test Software Tonscend JS32-RE 5.0.0HKE-082 / / RSE Test Software Tonscend JS36-RSE 5.0.0 HKE-184 / / Page 47 of 72 Report No.: HK2507304199-2E Test Data All the test modes completed for test. Only the worst result was reported as below: Below 1GHz Horizontal: Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level; Page 48 of 72 Report No.: HK2507304199-2E Vertical: Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level; Harmonics and Spurious Emissions Frequency Range (9kHz-30MHz) Frequency (MHz) Level@3m (dBμV/m) Limit@3m (dBμV/m) -- -- -- -- -- -- -- -- -- -- -- -- Note:1. Emission Level=Reading+ Cable loss-Antenna factor-Amp factor. 2. The emission levels are 20 dB below the limit value, which are not reported. It is deemed to comply with the requirement. Page 49 of 72 Report No.: HK2507304199-2E Above 1GHz Radiated Emission Test LOW CH1 (802.11b Mode)/2412 Horizontal: FrequencyReading ResultFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 482448.72-3.6445.087428.92peak 482442.18-3.6438.545415.46AVG 723648.57-0.95…
Text truncated - open the document above for the full version.
Test Model:PH960S Radiated Emissions AC Conducted Emission RF Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.30 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 28.44 mW |