FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Lijiang Trading Co., Ltd./
  3. 2BM7O-A02

2BM7O-A02Aquarium light

Guangzhou Lijiang Trading Co., Ltd.
Aquarium light - FCC ID 2BM7O-A02 - Guangzhou Lijiang Trading Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 07, 2025
Application Purpose
Original Equipment
Equipment Note
Aquarium light
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangzhou Lijiang Trading Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCCStatement ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewith theinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereis noguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferenceby oneormoreofthefollowingmeasures: •Reorientorrelocatethereceivingantenna. •Increasetheseparationbetweentheequipmentandreceiver. •Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. • Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenotexplicitlyapprovedbymanufacturer couldvoidyourauthoritytooperatethisequipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. RFExposureInformation ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance20cm betweentheradiatorandyourbody.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BM7O-A02 A02 We, Applicant Company Name: Guangzhou Lijiang Trading Co., Ltd. Address: 522, No. 3 Wangting Road, Xinhua Street, Huadu District, Guangzhou, Guangdong 510815, China Phone: +86-757-25589568 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2025-01-06 Signature Date Printed Name of Signee / Title: Chunlu Liu / Manager Company: Guangzhou Lijiang Trading Co., Ltd. Address: 522, No. 3 Wangting Road, Xinhua Street, Huadu District, Guangzhou, Guangdong 510815, China Phone: +86-757-25589568 Fax: N/A Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BM7O-A02 A02 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Parts Lists • the Tune Up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2025-01-06 Signature Date Printed Name of Signee / Title: Chunlu Liu / Manager Company: Guangzhou Lijiang Trading Co., Ltd. Address: 522, No. 3 Wangting Road, Xinhua Street, Huadu District, Guangzhou, Guangdong 510815, China Phone: +86-757-25589568 Fax: N/A Email: [email protected]

External Photos

Page1of4FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L2.0cmxW1.0cm) LabelLocation Aquariumlight Model:A02 FCCID:2BM7O-A02

Internal Photos

Page1of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 Fig.10 Antenna Page6of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12 Page7of7FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.13

RF Exposure Info

Page1of3FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation EUT:Aquariumlight TestModel:A02 Ratings:Input:110-240V~,50/60Hz Output:24V-130V HardwareVersion:/ SoftwareVersion:/ BluetoothFrequencyRange:2402MHz~2480MHz ChannelNumber:40channelsforBluetoothV5.0(DTS) ChannelSpacing:2MHzforBluetoothV5.0(DTS) ModulationType:GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:PCBAntenna,-0.58dBi(Max.) Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice DateofTest :December17,2024~December24,2024 DateofReport : December25,2024 Page2of3FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthe publicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevice wherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissible Exposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumofthe MPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioof eachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsand exposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthe testfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulations maybeusedtodeterminetheMPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimple calculationsbasedonfar-fieldplane-waveequivalentconditions.Theantennainstallationandoperating requirementsforthehostdevicemustmeettheminimumtestseparationdistancesrequiredbyallantennas,inboth standaloneandsimultaneoustransmissionoperations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic,and ElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4Ď€R² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna Page3of3FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Notes InternalPCBAntenna2400MHz-2500MHz-0.58dBiBTAntenna 6.ConductedPower [BTLE] ModeChannelFrequency(MHz) PeakConductedOutputPower (dBm) GFSK 002402-0.09 192440-0.11 392480-1.19 7.ManufacturingTolerance [BTLE] GFSK(Peak) ChannelChannel00Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 8.MeasurementResults 8.1StandaloneMPEEvaluation AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromanybodypart oftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparationdistance,r=20cm, aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensitycanbeobtained. [BTLE] ModulationType OutputpowerAntenna Gain (dBi) AntennaGain (linear) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW BTLE1.0 1.2589 -0.58 0 . 875 00.000 2 1.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.Outputpowerwasadjusttodutycycleat100%ifmeasureddutycyclelessthan98%; 3.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer. 8.2SimultaneousTransmissionMPEEvaluation TheEUTequipedwithonemoduleandoneantenna.Sononeedconsidersimultaneoustransmission. 9.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureofmobile device. ----------------THEENDOFREPORT---------------

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dBi Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Address No. 333 Kexing Road, Xiangzhou District, Zhuhai, China Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Page1of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBLE(ConductedMeasurement) ProductName:Aquariumlight TestModel:A02 EnvironmentalConditions Temperature: 23.8ď‚°C RelativeHumidity: 52.1% ATMPressure: 100.0kPa TestEngineer: JayLuo Supervisedby: NickPeng Page2of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.6720.5Pass NVNTBLE1M2440Ant10.6580.5Pass NVNTBLE1M2480Ant10.6560.5Pass Page3of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 Page4of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity -6dBBandwidthNVNTBLE1M2480MHzAnt1 Page5of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2MaximumPeakConductedOutputPower ConditionModeFrequency(MHz)AntennaTotalPower(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant1-0.0930Pass NVNTBLE1M2440Ant1-0.1130Pass NVNTBLE1M2480Ant1-1.1930Pass Page6of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2440MHzAnt1 Page7of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PowerNVNTBLE1M2480MHzAnt1 Page8of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3MaximumPowerSpectralDensityLevel ConditionModeFrequency(MHz)AntennaConductedPSD(dBm/3kHz)Limit(dBm/3kHz)Verdict NVNTBLE1M2402Ant1-16.638Pass NVNTBLE1M2440Ant1-16.778Pass NVNTBLE1M2480Ant1-18.128Pass Page9of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 Page10of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity PSDNVNTBLE1M2480MHzAnt1 Page11of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.4BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-56.41-20Pass NVNTBLE1M2480Ant1-55.07-20Pass Page12of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission Page13of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission Page14of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.5ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-53.62-20Pass NVNTBLE1M2440Ant1-54.61-20Pass NVNTBLE1M2480Ant1-53.62-20Pass Page15of23FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDi…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 34 FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For GuangzhouLijiangTradingCo.,Ltd. Aquariumlight TestModel:A02 Preparedfor:GuangzhouLijiangTradingCo.,Ltd. Address:522,No.3WangtingRoad,XinhuaStreet,HuaduDistrict, Guangzhou Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:December17,2024 Numberoftestedsamples:2 SampleNo.:A241203033-1,A241203033-2 Serialnumber:Prototype DateofTest:December17,2024~December24,2024 DateofReport:December25,2024 Page 2 of 34 FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA12064192EA DateofIssue.......................................:December25,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:GuangzhouLijiangTradingCo.,Ltd. Address................................................:522,No.3WangtingRoad,XinhuaStreet,HuaduDistrict, Guangzhou TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................: TRF-4-E-145A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................: Aquariumlight TradeMark..........................................: N/A TestModel...........................................: A02 Ratings.................................................:Input:110-240V~,50/60Hz Output:24V-130V Result...................................................: Positive Compiledby:Supervisedby:Approvedby: JokerHu/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 34 FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestModel...............................:A02 EUT.........................................:Aquariumlight Applicant...............................:GuangzhouLijiangTradingCo.,Ltd. Address..................................:522,No.3WangtingRoad,XinhuaStreet,HuaduDistrict, Guangzhou Telephone...............................:/ Fax..........................................:/ Manufacturer........................:GuangzhouLijiangTradingCo.,Ltd. Address...................................:522,No.3WangtingRoad,XinhuaStreet,HuaduDistrict, Guangzhou Telephone...............................: / Fax..........................................: / Factory...................................:GuangzhouLijiangTradingCo.,Ltd. Address...................................:522,No.3WangtingRoad,XinhuaStreet,HuaduDistrict, Guangzhou Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA12064192EA December25,2024 Dateofissue Page 4 of 34 FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000December25,2024InitialIssue--- Page 5 of 34 FCCID:2BM7O-A02ReportNo.:LCSA12064192EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)........................................................................................................................6 1.2.SUPPORTEQUIPMENTLIST.................................................................................................................................7 1.3.EXTERNALI/OCABLE..........................................................................................................................................7 1.4.DESCRIPTIONOFTESTF…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of2FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2BM7O-A02 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3

Contact Information

Applicant

chunlu liu
[email protected]Fax: 0757-25589568

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz980.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing.