FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Shenjiujiu Supply Chain Management Co., Ltd./
  3. 2BM9V-S680

2BM9V-S680Apple Magsafe Wireless Charge

Shenzhen Shenjiujiu Supply Chain Management Co., Ltd.
Apple Magsafe Wireless Charge - FCC ID 2BM9V-S680 - Shenzhen Shenjiujiu Supply Chain Management Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 26, 2026
Application Purpose
Original Equipment
Equipment Note
Apple Magsafe Wireless Charge
Frequency Range
0.11500000 - 0.20500000
Company
Shenzhen Shenjiujiu Supply Chain Management Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

6. TYPE-C线 *1 Thank you for purchasing and using this product. In order to bring you For a better user experience, please read this manual carefully. User Manual for Vacuum Magnetic Wireless Charging Bracket Packaging List and Parameter Description packing list 6.TYPE-C line * 1 1. Host * 1 2. Magnetic attraction plate * 1 3. Instruction manual * 1 4. Circular gasket * 1 5. Cleaning kit * parameter information Product Name: Vacuum Magnetic Wireless Charging Input voltage/current: 5-9V3A recommended for use with QC3.0 charging head Output power: 5W/7.5W/10W/15W (Max) Output frequency: 110K-205KHz Supporting specifications: Charging in accordance with QI wireless charging protocol Best wireless charging distance: 0-2mm Device interface: Type-C 1 Instructions for use 1. Wipe with a wet towel/cloth towel to absorb the negative position before Wipe the surface dust with a dry towel cloth. 3. Adjust the required position of the through the three hinges,and the is automatically absorbed on the magnetic suction component. 4. When you need to move the suction cup position/take away thi s product At that time, it is necessary to transfer 90 degrees counterclockwise to turn the base Back to the unlock position, gently buckle the bottom of the bracket with your finger The suction cup takes away the product, and the product can be folded and stored. 2. Put this product clean and need to be adsorbed. The smooth surface, and then adjust the appropriate angle and Press the product to turn the base 90 degrees clockwise. At this time, the suction cup will be f irmly attached to the specified position. precautions 1. Do not excessively squeeze or collide with the equipment 2. Do not use wireless chargers in severely high-temperature, humid, or corrosive environments to avoid damaging the device's circuitry. 3. USB application requires a device connected to the QC3.0 car charger head to function properly. (Connecting to the car's built-in USB port can easily cause charging and other issues) Thank you for using this product! Certificate of conformity Inspector: Ex-factory date: The pictures are for reference only,and the actual product shall prevail The interpretation right of this product belongs to the original manufacturer 60x81mm Function Description Product Introduction A: Magnetic wireless charging component B: 180 degree rotation axis C: 360 degree rotation axis D: Rotating locking mechanism E: Suction cup component This product adopts a suction cup negative pressure structure. By rotating the base to slide the pull shaft to the highest position of the slope, the suction cup is stretched to form negative pressure, achieving rapid suction and fixation on the car (home) windshield or other smooth surface (display screen) car interior panel (smooth marble/tile/smooth desktop). The phone can be directly placed on the movable seat and fixed by magnetic suction: through the cooperation of three rotating sha fts, the height and rotation angle of the movable seat can be adjusted at any time to adjust the phone to the desired position and angle; When it needs to be removed, rotate the base back to the unlocking position, and use your fingers to lightly tap the suction cup at the bottom of the bracket to remove this product. The operation is simple and convenient. In addition, during rotation, it has a rotating locking sound effect, providing additional feedback and prompt functions. This product supports wireless charging function Function Introduction Connecting the power supply Connect the USB end of the data cable to the rechargeable port on the car (it is not recommended to use the car's original USB port, it is recommended to connect the cigarette lighter charging head) 3 in 1 本产品解释权归原厂家

Attestation Statements

ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Jan.21,26 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BM9V-S680 ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd.(“theapplicant”)certifiesthat,asofthe dateofthefilingoftheapplication,theapplicantisnotidentifiedontheCoveredList,established pursuantto§1.50002ofreferencechapter,asanentityproducing“covered”communicationequipment. Theequipmentforwhichauthorizationissoughtisnot“covered”telecommunicationsequipmentand videosurveillanceequipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthat prohibitedfromreceivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:lanfangWu Title:CEO Address:A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Tel.:+8613027941006 Email:[email protected]

Attestation Statements

ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Jan.21,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2BM9V-S680] ProductName:[AppleMagsafeWirelessCharge] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:lanfangWu Title:CEO Address:A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Tel.:+8613027941006 Email:[email protected] ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Jan.26,26 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:2BM9V-S680 ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd.(“theapplicant”)certifiesthat,asofthe dateofthefilingoftheapplication,[LOBOSIOWAINC](“theagent”)isourdesignatedU.S.agent forserviceofprocessfortheabovereferenceFCCID.Theapplicantacceptstomaintainanagent forserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., ortheconclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingthe equipment,whicheverislater.Theapplicantfurtheracknowledgesitisourresponsibilitytoinform theFCCwhenevertheagentinformationchanges. [LOBOSIOWAINC]("theagent)understanditistheagent'sobligationtoacceptserviceofprocess intheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agent CompanyName:LOBOSIOWAINC FRN:0036413961 Address:4623BittercreekDrColoradoSpringsco 80922Us Signature: ContactPerson:HarleyLi Tel:(818)818-0538Email:[email protected] Applicant CompanyName:ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. FRN:0036473817 Address:A1-013,Floor1,MingtongDigitalCity,No. 23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Signature: ContactPerson:lanfangWu Tel:+8613027941006Email:[email protected]

Cover Letter(s)

ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China 1/26/2026 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BM9V-S680 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram  Schematics OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. Sincerely, (Signature) PrintedName:lanfangWu Title:CEO Address:A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Tel.:+8613027941006 Email:[email protected]

Cover Letter(s)

ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Date:Jan.26,26 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BM9V-S680 I,theundersigned,herebyauthorize(CTSLTesting(Dongguan)Co.,Ltd.)toactonourbehalfinall mattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(CTSLTesting(Dongguan)Co.,Ltd.)shallhavethesameeffectasourownandI acknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification,as specifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(ShenzhenShenjiujiu SupplyChainManagementCo.,Ltd.). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, ApplicantSignature: PrintedName:lanfangWu Title:CEO Address:A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity,Huaqiang NorthStreet,FutianDistrict,Shenzhen,China Tel.:+8613027941006 Email:[email protected]

External Photos

Page1of5 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexA. EUTExternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com AnnexA. EUTExternalPhotos Photo1ExternalphotosofEUT Photo2ExternalphotosofEUT Page2of5 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexA. EUTExternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com Photo3ExternalphotosofEUT Photo4ExternalphotosofEUT Page3of5 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexA. EUTExternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com Photo5ExternalphotosofEUT Photo6ExternalphotosofEUT Page4of5 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexA. EUTExternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com Photo7ExternalphotosofEUT Photo8ExternalphotosofEUT Page5of5 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexA. EUTExternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com Photo8ExternalphotosofEUT ------------------------------------------EndofEUTExternalPhotos------------------------------------------

ID Label/Location Info

LabelandLabelLocation FCCID:2BM9V-S680 L*W:10mm*5mm labelandWhitefont

Internal Photos

Page1of2 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexB. EUTInternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com AnnexB. EUTInternalPhotos Photo1InternalphotosofEUT Photo2InternalphotosofEUT Antennaposition Page2of2 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexB. EUTInternalPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com Photo3InternalphotosofEUT Photo4InternalphotosofEUT ------------------------------------------EndofEUTInternalPhotos------------------------------------------

RF Exposure Info

FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RFExposureEvaluation FCCID:2BM9V-S680 Applicant Name ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. Applicant Address A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity, HuaqiangNorthStreet,FutianDistrict,Shenzhen,China Manufacturer Name ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. Manufacturer Address A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity, HuaqiangNorthStreet,FutianDistrict,Shenzhen,China TradeMark ProductnameAppleMagsafeWirelessCharge MainTest Model S680 SeriesModels-- Standard FCCCFR47part1,1.1307(b),1.1310,47CFRS2.1091: KDB680106WirelessPowerTransferD01V04 TestLocation ISO/IEC17025byILAC-MRAisA2LA7556.01 CTSLTesting(Dongguan)Co.,Ltd. Room112,Building1,No.15,JiaoyuansongshanHetianVillage,HoujieTown DongguanCity,Guangdong,People’sRepublicofChina ReceiptDate2025.8.28Testperiod2025.8.28-2025.11.20IssueDate2025.11.20 Conclusion Theequipmentundertestwasfoundtobecompliancewiththerequirementsof thestandardsapplied. Performs Testing: EthanZhao TestReport Reviewer: SteveQin TestReport Authorizer: AlanLi Page 2 of 6 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) 4TestSetup 1MeasuringStandard KDB680106WirelessPowerTransferD01V04 2Requirements AllrequirementsrefertoSection3ofKDB680106D01V04: 1.Thedevicesmaybeconsideredtomeetthe§2.1091-Mobileconditions(“generallybeusedinsucha waythataseparationdistanceofatleast20centimetersisnormallymaintainedbetweentheRF source'sradiatingstructure(s)and[thenearestperson]”) 2.DevicesOperatingatFrequenciesBelow4MHz. 3.For§2.1091-Mobiledevices,theMPElimitsbetween100kHzto300kHzaretobeconsideredthe sameasthoseat300kHzinTable1of§1.1310,thatis,614V/mand1.63A/m,fortheelectricfieldand magneticfield,respectively. Page 3 of 6 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(20cmfromthetop)whichisbetween theedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01WirelessPower Transferv04. 6. MeasurementUncertainty (95%confidencelevels,k=2) ItemUncertainty UncertaintyforH-Field2.36dB UncertaintyforE-Field2.42dB UncertaintyforconductedRFPower0.62dB Uncertaintyfortemperature0.2°C Uncertaintyforhumidity1.1% UncertaintyforDCandlowfrequencyvoltages0.06% 7.Equipmentlist TestEquipmentManufacturerModelNo.SN.Last calibration Calibrated until Electricand Magnetic field probe-Analyzer NardaEHP-200AN03565Aug25,2025Aug24,2026 7PlacementMode4Photo Page 4 of 6 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 8Testmode Mode1Phone(5W) Mode2Phone(7.5W) Mode3Phone(10W) Mode4Phone(15W) Page 5 of 6 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 9Necessaryaccessories EquipmentMfr/BrandModel/TypeNo.SerialNo.Note 1PhoneXiaomixiaomi12sultraN/A Thisisfortestingonlyin report. 2VoltagesourceZHAOXINRXN-605D-IIN/ATestuse 3AdapterXiaomiAD652GN/A Thisisfortestingonly inreport. 10TestResult PlacementMode4(Worst) E-FiledStrengthat20cmfromtheedgessurroundingtheEUT(V/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Positio nC Test Positio nD Limit s (V/m) Result 1%0.115-0.2051.261.220.490.48614 PASS 50%0.115-0.2051.351.290.440.45614 PASS 95%0.115-0.2051.201.320.470.49614 PASS E-FiledStrengthat20cmfromthetopoftheEUT(V/m) Battery power Frequency Range(MHz) Test PositionE Limits (V/m) Result 1%0.115-0.2051.17614 PASS 50%0.115-0.2051.19614 PASS 95%0.115-0.2051.16614 PASS H-FiledStrengthat20cmfromtheedgessurroundingtheEUT(A/m) Page 6 of 6 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) Result 1%0.115-0.2050.390.610.580.591.63PASS 50%0.115-0.2050.370.620.560.551.63PASS 95%0.115-0.2050.400.590.520.531.63PASS H-FiledStrengthat20cmfromthetopoftheEUT(A/m) Battery power Frequency Range(MHz) Test PositionE Limits (A/m) Result 1%0.115-0.2050.45 1.63PASS 50%0.115-0.2050.45 1.63PASS 95%0.115-0.2050.48 1.63PASS ※※※※※ENDOFTHEREPORT※※※※※

Test Report

Document Number Product Name Product size A 20.5±0.5 B 39.0±1.0 C 43.5±0.5 D 35±2 E 4 0AX F 1.17±0.1 G 0.6±0.1 H Φ 39 1.8±0.1 .0*20.5 Wire Test frequency Testing method material Number of turns Disk size L Coil size 100KHZ Series testing Customer feedback Tabulation Chen Confirm Lihua 2023062 Date 6 Unit:mm 0.08*48thighWinding method Single-line winding type N o t e The coil is in a countercloc kwise direction 11 Ts Φ 43.5*Φ 5*0.6 6.8±10% Shenzhen Yongman Digital Co., Ltd. 2nd Floor, Building 1, Tiantong Industrial Park, Gaofeng Community, Dalang Street, Longhua District, Shenzhen Wireless charging transmitter coil module Φ 43.5*Φ 5*H1.8 Bonding method Hot air self-adhesive Tabulation

Test Report

FCCPART15SUBPARTC FCCPART15.209 TESTREPORT FCCID:2BM9V-S680 ReportNo:CTSL2521220066 ProductName:AppleMagsafeWirelessCharge MainTestModel:S680 SeriesModels:-- Applicant: ShenzhenShenjiujiuSupplyChainManagementCo., Ltd. EXECUTIVESUMMARY AsampleofthisproductwastestedandfoundtobeincompliancewithFCCPART15C, FCCPART15SUBPARTC(15.209). Anyreproductionofthisdocumentmustbedoneinfull.Nosinglepartofthisdocumentmay bereproducedwithoutpermissionfromCTSL;AllTestDataPresentedinthisreportisonly applicabletopresentedTestsample. CTSLTesting(Dongguan)Co.,Ltd. Building1,HoujieRoadHoujieTown,GuangdongProvince,DongguanCityP.R.C. Page 2 of 24 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 TestReport FCCID:2BM9V-S680 Applicant Name ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. Applicant Address A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity, HuaqiangNorthStreet,FutianDistrict,Shenzhen,China Manufacturer Name ShenzhenShenjiujiuSupplyChainManagementCo.,Ltd. Manufacturer Address A1-013,Floor1,MingtongDigitalCity,No.23,HuafaNorthRoad,LicunCommunity, HuaqiangNorthStreet,FutianDistrict,Shenzhen,China TradeMark ProductnameAppleMagsafeWirelessCharge MainTest Model S680 SeriesModels-- Standard FCCPart15SubpartC(15.209) ANSIC63.10:2020 FCCKDB558074D0115.209MeasGuidancev05r02 TestLocation ISO/IEC17025byILAC-MRAisA2LA7556.01 CTSLTesting(Dongguan)Co.,Ltd. Room112,Building1,No.15,JiaoyuansongshanHetianVillage,HoujieTown DongguanCity,Guangdong,People’sRepublicofChina ReceiptDate2025.8.28Testperiod2025.8.28-2025.11.20IssueDate2025.11.20 Conclusion Theequipmentundertestwasfoundtobecompliancewiththerequirementsof thestandardsapplied. Performs Testing: EthanZhao TestReport Reviewer: SteveQin TestReport Authorizer: AlanLi Page 3 of 24 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................5 1.1TESTFACTORY................................................................................................................6 1.2MEASUREMENTUNCERTAINTY.....................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................8 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS..................9 2.4TESTEQUIPMENT..........................................................................................................10 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................12 3.1LIMIT................................................................................................................................12 3.2TESTPROCEDURE........................................................................................................12 3.3TESTSETUP...................................................................................................................13 3.4TESTRESULTS...............................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................16 4.1LIMIT................................................................................................................................16 4.2TESTPROCEDURE........................................................................................................17 4.3TESTSETUP...................................................................................................................18 4.4TESTRESULTS...............................................................................................................19 (30MHZ-1000MHZ)................................................................................................................20 5.20DBBANDWIDTHTEST.....................................................................................................22 5.1LIMIT................................................................................................................................22 5.2TESTPROCEDURE........................................................................................................22 5.3TESTSETUP...................................................................................................................22 5.4TESTRESULTS...............................................................................................................23 6.ANTENNAREQUIREMENT...................................................................................................24 6.1STANDARDREQUIREMENT..........................................................................................24 6.2EUTANTENNA................................................................................................................24 Page 4 of 24 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 RevisionHistory Rev.IssueDateEffectPageContents 002025.11.20N/AN/A Page 5 of 24 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 1.SUMMARYOFTESTRESULTS FCCRulesandRegulationsPart15SubpartC,Section209 Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.209(a)(f)RadiatedSpuriousEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2020 Page 6 of 24 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 1.1TESTFACTORY EMCLab: A2LACertificateNumber:7556.01; CTSLTesting(Dongguan)Co.,Ltd.hasbeenlistedbyAmerican AssociationforLaboratoryAccreditationtoperformelectromagneticemissionmeasurement. The3m-SemianechoictestsitefulfilsCISPR16-1-4accordingtoANSIC63.10andCISPR 16-1-4:2010…

Text truncated - open the document above for the full version.

Test Setup Photos

Page1of1 CTSLTesting(Dongguan)Co.,Ltd. ReportNo.:CTSL2521220066 AnnexC. TestSetupPhotos FCCID:2BM9V-S680 Room112,Building1,No.15,Jiaoyuansongshan,HetianVilltage,HoujieTown,DongguanCity,Guangdong,China. Tel:0769-86009597E-mail:[email protected]://www.ctsl-lab.com AnnexC. TestSetupPhotos Photo1TestSetupPhotosofRadiatedEmissionTest(9K-30MHz) Photo2TestSetupPhotosofACPowerLineConductedEmissions ------------------------------------------EndofTestSetupPhotos------------------------------------------

Contact Information

Applicant

Wu lan fang
[email protected]Fax: +8613027941006

Technical Contact

LOBOS IOWA INCHarley Li
[email protected]

4623 Bittercreek Dr Colorado · Springs, Colorado, 80922 · United States

Test Firm

CTSL Testing (Dongguan) Co., Ltd.Liz Zhang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Shenjiujiu Supply Chain Management Co., Ltd.

2BM9V-M9L

Car wireless charger

Dec 04, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz