Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
功能键 开关机按键 长按按键开机 手机扫描手表 二维码下载软 件 打开包装,首 次使用建议 充电�-�小时 FUNCTION KEY POWER KEY Scan the QR code on the watch with your phone to download the software Long press the button to turn on �. 关机状态长按可让手表开机 �. 开机状态长按出现关机页面 �. 在表盘页面按一下可以进入菜单,快速 按键两下可切换菜单风格 �.其余页面下按一下按钮都可返回表盘页 面 功能键 FUNCTION KEY �. When the watch is off, long press to power it on. �. When the watch is on, long press to open the power-off interface. �. Press once on the dial screen to enter the menu. Double press quickly to switch menu style. �. Press the button once on other screens to return to the dial screen. FCC Caution. This device complies with part �� of the FCC Rules. Operation is subject to the following two conditions: (�)This device may not cause harmful interference, and (�) this device must accept any interference received,including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could voidthe user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part �� of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates uses and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions, may cause harmfulinterference to radio communications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:-Reorient or relocate the receiving antenna -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. *RF warning for Portable device: The device has been evaluated to meet general RF exposure requirement. The device can be sed inportable exposure condition without restriction.
ShenzhenYuxiangTechnologyCo.,Ltd CoveredEquipmentCertificationAttestationLetter 4/17/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2BMSW-Y9 ShenzhenYuxiangTechnologyCo.,Ltd(“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. ShenzhenYuxiangTechnologyCo.,Ltd(“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,theapplicantisnotidentifiedontheCoveredListasanentity producing“covered”equipment. ShenzhenYuxiangTechnologyCo.,Ltd(“theapplicant”)certifiesthattheequipmentfor whichauthorizationissoughtdoesnotincludecybersecurityoranti-virussoftware producedorprovidedbyKasperskyLab,Inc.oranyofitssuccessorsandassignees, includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Signed: Printedname:ZhangYu Title:Manager CompanyName:ShenzhenYuxiangTechnologyCo.,Ltd Date:4/17/2026
ShenzhenYuxiangTechnologyCo.,Ltd 4/20/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa,Ontario,Canada K1V1H2 REQUESTFORCONFIDENTIALITY-FCC FCCID:2BMSW-Y9 PursuanttoSections0.457(d)(1)(ii)and0.459oftheCommission’sRulesandFCCGuidance document726920,weherebyrequestconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: PERMANENTLONG-TERMCONFIDENTIALITY: Schematics BlockDiagrams TheoryofOperation Theaboveinformationcontainstradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthisinformationmightbeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors.TheApplicantunderstandsthatpursuanttoRule 0.457(d)(1)(ii),disclosureofthisApplicationandallaccompanyingmaterialswillnotbemadebefore thedateoftheGrantforthisApplication. Sincerely, Signed: Printedname:ZhangYu Title:Manager
FCCID:2BMSW-Y9 FCCID:2BMSW-Y9 FCCID:2BMSW-Y9 FCCID:2BMSW-Y9 FCCID:2BMSW-Y9
LabelandLabelLocation FCCID:2BMSW-Y9
FCCID:2BMSW-Y9 FCCID:2BMSW-Y9 FCCID:2BMSW-Y9 ANT
Page 1 of 2 RF EXPOSURE EVALUATION FCC ID: 2BMSW-Y9 Product Name : Smart watch Model Name : Y9 Bluetooth Version : BT 5.4 BDR+EDR+BLE Operating frequency : 2402-2480MHz Numbers of Channel : 79 channels for BDR+EDR 40 channels For DTS Antenna Type : Integrated antenna Antenna Gain : -0.76dBi Type of Modulation : GFSK, Π/4-DQPSK,8DPSK For DSS GFSK, For DTS Power supply : Input: DC 5V Li-ion Battery : 471932 Rated Voltage: 3.7V Capacity: 250mAh Hardware Version : V1.0 Software Version : V102 Page 2 of 2 Standard Requirement According to § 15.247(i) and § 1.1307b(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. See KDB 447498 D01 General RF Exposure Guidance v06, section 4. 3. 1. The 1-g and 10-g SAR test exclusion thresholds for 100MHz to 6GHz at test separation distances ≤ 50mm are determined by: [ (max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]*[ √f(GHz)] ≤3.0 for 1-g SAR and ≤7.5 for 10-g SAR extremity SAR, where ⚫ f(GHz) is the RF channel transmit frequency in GHz ⚫ Power and distance are rounded to the nearest mW and mm before calculation ⚫ The result is rounded to one decimal place for comparison. The test exclusions are applicable only when the minimum test separation distance is ≤ 50mm and for transmission frequencies between 100MHz and 6GHz. When the minimum test separation distance is <5mm, a distance of 5mm is applied to determine SAR test exclusion. Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval. Channel (MHz) Maximum output power (dBm) Tune up tolerance (dBm) Max Tune Up Power (mW) Distance (mm) Calculation results Limit Operating Mode 2402 1.43 1.43±1 1.749847 5 0.542396 3 2DH5 2402 1.09 1.09±1 1.618080 5 0.501553 3 BLE_1M According to KDB 447498, The device only support BT function, and no simultaneous SAR measurement is required. Signature Simon Pu Manager Date: 2026-04-12
Shenzhen Fbetter Electronics Co.,Ltd Unit 1007, Building C2, Phase II, Chuangzhi Yuncheng, Xili Street, Nanshan District, Shenzhen Notesforantennainstallation Model Name: Y9 Notesforantennainstallation Electronicwireinstallationrecommendations: 1:Theelectronlinelengthisinthe24.60mm. 2:Theelectronicwireisinstalledonthesideofthehorn. 3:Theendoftheelectronicwireisfixedwithadhesive papertomaketheconsistencyofthebatchproductiongood. Antennaparameters Freq2.4GHz2.5GHzspce VSWR1.481.79 < 2 LogMag-14.15-10.93 < -10 Antennaparameters Frequency/MhzEfficiency / %Gain/dBi 24004.2-1.84 24104.21-1.62 24204.33-1.42 24304.38-1.30 24404.4-1.05 24504.66-0.86 24604.8-0.76 24705.01-0.82 24804.7-1.23 24904.65-1.39 25004.29-1.64
Report No.: PTC26020503003E-FC01 Page 1 of 88 FCC TEST REPORT FCC ID: 2BMSW-Y9 Product : Smart watch Model Name : Y9 Brand : N/A Report No. : PTC26020503003E-FC01 Prepared for Shenzhen Yuxiang Technology Co., Ltd Room 216, Building A, No. 33 Gonghe Industrial Road, Gongle Community, Xixiang Street, Bao'an District, Shenzhen City Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC26020503003E-FC01 Page 2 of 88 1 TEST RESULT CERTIFICATION Applicant’s name : Shenzhen Yuxiang Technology Co., Ltd Address : Room 216, Building A, No. 33 Gonghe Industrial Road, Gongle Community, Xixiang Street, Bao'an District, Shenzhen City Manufacture's name : Shenzhen Yuxiang Technology Co., Ltd Address : Room 216, Building A, No. 33 Gonghe Industrial Road, Gongle Community, Xixiang Street, Bao'an District, Shenzhen City Product name : Smart watch Model name : Y9 Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10-2020 Test Date : Mar. 17, 2026 to Apr. 12, 2026 Date of Issue : Apr. 12, 2026 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC26020503003E-FC01 Page 3 of 88 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 3 TEST FACILITY ............................................................................................................................................................ 5 4 GENERAL INFORMATION ........................................................................................................................................ 6 4.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 6 4.2 TEST MODE ........................................................................................................................................................ 7 5 EQUIPMENT DURING TEST ..................................................................................................................................... 9 5.1 EQUIPMENTS LIST............................................................................................................................................... 9 5.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 5.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 6 CONDUCTED EMISSION ......................................................................................................................................... 13 6.1 E.U.T. OPERATION ........................................................................................................................................... 13 6.2 EUT SETUP ...................................................................................................................................................... 13 6.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 6.4 MEASUREMENT PROCEDURE: .......................................................................................................................... 14 6.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 6.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 6.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 7 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 7.1 EUT OPERATION .............................................................................................................................................. 17 7.2 TEST SETUP ..................................................................................................................................................... 18 7.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 19 7.4 TEST PROCEDURE ............................................................................................................................................ 20 7.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 21 8 MAXIMUM PEAK OUTPUT POWER TEST .......................................................................................................... 28 8.1 TEST STANDARD AND LIMIT .............................................................................................................................. 28 8.2 TEST SETUP ..................................................................................................................................................... 28 8.3 TEST PROCEDURE ............…
Text truncated - open the document above for the full version.
FCCID:2BMSW-Y9 ConductedEmissions RadiatedSpuriousEmissions From30MHz-1000MHz FCCID:2BMSW-Y9 TestfrequencyfromAbove1GHz
19 GEORGETOWN · IRVINE, California, 92612 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.39 mW |

Smart watch
Equipment Class
DTS - Digital Transmission System