FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nanjing Toua Robot Technology Co.,Ltd/
  3. 2BN5V-C1

2BN5V-C1Robotic Pool Cleaner

Nanjing Toua Robot Technology Co.,Ltd
Robotic Pool Cleaner - FCC ID 2BN5V-C1 - Nanjing Toua Robot Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 18, 2026
Application Purpose
Original Equipment
Equipment Note
Robotic Pool Cleaner
Frequency Range
2402.00000000 - 2480.00000000
Company
Nanjing Toua Robot Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

100g 80g 251211

Attestation Statements

Rev1/26/2023 (NanjingTouaRobotTechnologyCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:03-13-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BN5V-C1 [NanjingTouaRobotTechnologyCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. [NanjingTouaRobotTechnologyCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedby KasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwithintegratedKaspersky Lab,Inc.(oranyofitssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24- 886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (BinMa) Rev1/26/2023 (NanjingTouaRobotTechnologyCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:03-13-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BN5V-C1 [NanjingTouaRobotTechnologyCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (BinMa)

Attestation Statements

NanjingTouaRobotTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:03-13-2026 SUBJECT:FCCID:2BN5V-C1 ToWhomItMayConcern: I,theundersigned,herebystatesthisequipmenthasbeentestedandfoundtocomply withthelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules,and willapplytheSupplier'sDeclarationofConformityproceduretotheclassB computerperipheralportionofthiscompositedevice.IunderstandthefollowingFCC requirements: 1.DevicessubjecttotheSDoCprocedurearerequiredtobetestedtoshow compliancewiththeFCCtechnicalregulationsbyarecognizedaccreditedtesting laboratory.ThetestinglaboratorymustbeaccreditedbyaCommissionapproved accreditationbodyordesignatedunderthetermsofagovernment-to-government MutualRecognitionAgreement(MRA).Alistingofthoseaccreditedtesting laboratoriesthathavebeenrecognizedbytheCommissionispublishedontheFCC Webpage:https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Selectthe "accredited"optiontosearchforFCCrecognizedaccreditedtestfirms.) 2.Pt2.1077containsthelistofinformationthatmustbeincludedintheSupplier's DeclarationofConformity,whichmustbesuppliedwitheachproductsold.The SDoCcomplianceinfoshallbeincludedintheUser’sManualorasaseparate sheet.Theinfomustcontainthename,address,andphonenumberofthe responsibleparty,whichmustbelocatedwithintheUnitedStates.Accordingto 2.909(b),theresponsiblepartyiseithertheManufactureroriftheproductis importedtheImporter. Regards, NanjingTouaRobotTechnologyCo.,Ltd ------------------------------- ( BinMa )

Attestation Statements

[NanjingTouaRobotTechnologyCo.,Ltd] [Room501,No.69,ShangQinhuaiStreet,JiangningDistrict,] [NanjingCity,JiangsuProvince] [China] Date:[03-13-2026] FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:2BN5V-C1 FRNoftheApplicant:[0036766723] USAgent–AttestationStatement/Part2.911(d)(7) [NanjingTouaRobotTechnologyCo.,Ltd]certifies,thatasof[03-13-2026],wehavedesignated FCCUSAgent,LLCtoacceptserviceofprocessonourbehalfforFCCID:2BN5V-C1. [NanjingTouaRobotTechnologyCo.,Ltd],acceptstomaintainanagentofserviceofprocessin theUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofany Commission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. FCCUSAgent,LLC,acceptsasofthedateofthefilingofthisapplication,theobligationofbeing thedesignatedagentforthepurposeofacceptingserviceofprocessonbehalfof[NanjingToua RobotTechnologyCo.,Ltd]forFCCID:2BN5V-C1. DesignatedAgentInformation: CompanyName:FCCUSAgent,LLC FRN:0033402884 Address:3722IllinoisAvenue,SaintCharles,IL,60174,USA ContactPerson:TimPayne Phone:708-571-3148 Email:[email protected] Sincerely, Company:[NanjingTouaRobotTechnology Co.,Ltd] DesignatedAgent:FCCUSAgent,LLC CompanyRepresentative:[BinMa]DesignatedAgentRepresentative:TimPayne Signature:Signature:

Cover Letter(s)

NanjingTouaRobotTechnologyCo.,Ltd Rev11/20/07 FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2BN5V-C1 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram Schematics OperationalDescription BlockDiagram Schematics OperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,Wealsorequestingthe commissiontograntshort-termconfidentialityrequestonthefollowingattachmentsuntil180 daysaftertheGrantDateofEquipmentAuthorizations. ExhibitTypeFileName Sincerely, BinMa 03-13-2026

Cover Letter(s)

NanjingTouaRobotTechnologyCo.,Ltd Declarationonmodeldifference Wetheundersignedherebyconfirmthatthesemodelsareidentical,andallmodelshavethesame RFmodule,PCBlayout,Antenna,schematicsandcomponent.Onlydifferentonmodelnumber, brandsandappearanceshape. ProductionnameTrademarkFCCModelno. RoboticPool Cleaner N/A2BN5V-C1TYPC1,TalosboC1,C1,**C1(**be singleormultipledigitsbyany alphabetsandpunctuationmarks denotingdifferentmodelnumber, brandsandappearanceshape) Confirmedby: BinMa NanjingTouaRobotTechnologyCo.,Ltd 03-13-2026

Cover Letter(s)

NanjingTouaRobotTechnologyCo.,Ltd FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:03-13-2026 SUBJECT:FCCApplicationforFCCID:2BN5V-C1 ToWhomItMayConcern: We,theundersigned,herebyauthorizeSamLv.atEMTEK(DONGGUAN)CO.,LTD.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyEMTEK(DONGGUAN)CO.,LTD.onourbehalfshallhave thesameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, Sincerely, BinMa 03-13-2026

External Photos

ReportNo.ENS2602030159W003Page1of6Ver.1.0 FCCID:2BN5V-C1 ReportNo.ENS2602030159W003Page2of6Ver.1.0 ReportNo.ENS2602030159W003Page3of6Ver.1.0 ReportNo.ENS2602030159W003Page4of6Ver.1.0 ReportNo.ENS2602030159W003Page5of6Ver.1.0 ReportNo.ENS2602030159W003Page6of6Ver.1.0

ID Label/Location Info

size:45mm*27mm C1

Internal Photos

ReportNo.ENS2602030159W003Page1of9Ver.1.0 FCCID:2BN5V-C1 ReportNo.ENS2602030159W003Page2of9Ver.1.0 ReportNo.ENS2602030159W003Page3of9Ver.1.0 ReportNo.ENS2602030159W003Page4of9Ver.1.0 BT/BLE/WIFIANT ReportNo.ENS2602030159W003Page5of9Ver.1.0 ReportNo.ENS2602030159W003Page6of9Ver.1.0 ReportNo.ENS2602030159W003Page7of9Ver.1.0 ReportNo.ENS2602030159W003Page8of9Ver.1.0 ReportNo.ENS2602030159W003Page9of9Ver.1.0

RF Exposure Info

ReportNo.ENS2602030159W00304RPage1of7Ver.1.0 $二维码$ TESTREPORT ProductName:RoboticPoolCleaner ModelNumber: TYPC1,TalosboC1,C1,**C1(**besingleor multipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentmodel number,brandsandappearanceshape) FCCID:2BN5V-C1 Preparedfor:NanjingTouaRobotTechnologyCo.,Ltd Address:Room501,No.69,ShangQinhuaiStreet,Jiangning District,NanjingCity,JiangsuProvince,China Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China TEL:(0755)26954280 FAX:(0755)26954282 ReportNumber:ENS2602030159W00304R Dateofsamplereceipt:Feb03,2026 Date(s)ofTests:Feb03,2026toMar04,2026 Dateofissue:Mar05,2026 $二维码$ ReportNo.ENS2602030159W00304RPage2of7Ver.1.0 TableofContents 1.TESTRESULTCERTIFICATION...............................................................................................................................................3 2.EUTSPECIFICATION.................................................................................................................................................................5 3.TESTREQUIREMENT:...............................................................................................................................................................6 RFEXPOSUREEVALUATION...................................................................................................................................................6 4.MEASUREMENTRESULT.........................................................................................................................................................7 ReportNo.ENS2602030159W00304RPage3of7Ver.1.0 1.TESTRESULTCERTIFICATION Applicant:NanjingTouaRobotTechnologyCo.,Ltd Address: Room501,No.69,ShangQinhuaiStreet,JiangningDistrict,NanjingCity, JiangsuProvince,China Manufacturer:NanjingTouaRobotTechnologyCo.,Ltd Address: Room501,No.69,ShangQinhuaiStreet,JiangningDistrict,NanjingCity, JiangsuProvince,China Factory:AnhuiTouaRobotCo.,Ltd. Address: Building4#,No.29,RunzhouRoad,DanyangTown,BowangDistrict, Maanshan,AnhuiProvince,P.R.China EUT:RoboticPoolCleaner ModelName: TYPC1,TalosboC1,C1,**C1(**besingleormultipledigitsbyanyalphabets andpunctuationmarksdenotingdifferentmodelnumber,brandsand appearanceshape) Trademark:N/A MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT §15.247(i),§2.1091PASS TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththeprocedures giveninANSIC63.10(2020)andtheenergyemittedbythesampleEUTtestedasdescribedinthisreportisin compliancewiththerequirementsofFCCRulesFCC§15.247(i),§2.1091. Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:Feb03,2026toMar04,2026 Preparedby: YuXiaolan/Editor Reviewer: XiaLilu/Supervisor Approve&AuthorizedSigner:WangLi/Manager ReportNo.ENS2602030159W00304RPage4of7Ver.1.0 ModifiedHistory VersionReportNo.RevisionDateSummary ENS2602030159W00304R/OriginalReport ReportNo.ENS2602030159W00304RPage5of7Ver.1.0 2. EUTSpecification CharacteristicsDescription Product:RoboticPoolCleaner ModelNumber: TYPC1,TalosboC1,C1,**C1(**besingleormultipledigitsbyanyalphabets andpunctuationmarksdenotingdifferentmodelnumber,brandsand appearanceshape) (Note:Thesemodelsarethesame,exceptforthemodelnumber,brandsand appearanceshape.TYPC1wasselectedforfulltest.) Sample:2# DeviceType: BT/BLE 2.4GWIFI DataRate: 802.11b 802.11g 802.11n(20MHzchannelbandwidth) 802.11n(40MHzchannelbandwidth) 1MbpsforGFSKmodulation 2Mbpsforπ/4-DQPSKmodulation 3Mbpsfor8DPSKmodulation 1MbpsforGFSKmodulation Modulation: DSSSwithDBPSK/DQPSK/CCKfor802.11b; OFDMwithBPSK/QPSK/16QAM/64QAMfor802.11g/n; GFSK,π/4-DQPSK,8DPSK OperatingFrequency Range(s): 2412-2462MHzfor802.11b/g/n(HT20); 2422-2452MHzfor802.11n(HT40); 2402-2480MHz NumberofChannels: 11channelsfor802.11b/g/n(HT20); 7Channelsfor802.11n(HT40); BT:79channels BLE:40channels TransmitPowerMax: BT:2.26dBm(0.001683W) BLE:-2.29dBm(0.000590W) 2.4GWIFI:15.47dBm(0.035237W) AntennaType:PCBAntenna AntennaGain: 2.33dBi Powersupply: DC22Vfromadapter Adapter:Model:FY0632202500U INPUT:100-240V~50/60Hz1.8A Output:22.0V⎓2.5A DC19.2Vbuilt-inbattery Evaluationapplied:MPEEvaluation SAREvaluation ReportNo.ENS2602030159W00304RPage6of7Ver.1.0 3. TestRequirement: RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironment impactofhumanexposuretoradiofrequency(RF)Radiationasspecifiedin§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=20,distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinputtotheantenna,through thecalculation,wewillknowthedistancewheretheMPElimitisreached. ReportNo.ENS2602030159W00304RPage7of7Ver.1.0 MeasurementResult Antennagain: 2.4G:2.33dBi Channel Freq. (MHz) modulation conducted power Tune-up power (dBm) MaxAntenna Evaluation result Power density Limits (dBm) tune-uppowerGain (mW/cm2)(mW/cm2) (dBm)(mW)(dBi)Numeric 2412 11B 14.4214±11531.6232.331.710.01081 243714.2714±11531.6232.331.710.01081 246215.4715±11639.8112.331.710.01351 2412 11G 11.7311±11215.8492.331.710.00541 243711.7711±11215.8492.331.710.00541 246213.4113±11425.1192.331.710.00851 2412 11N20SISO 11.6911±11215.8492.331.710.00541 243711.6211±11215.8492.331.710.00541 246213.2413±11425.1192.331.710.00851 2422 11N40SISO 10.8110±11112.5892.331.710.00431 243711.1511±11215.8492.331.710.00541 245211.8211±11215.8492.331.710.00541 Antennag…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ENS2602030159W00301RPage1of74Ver.1.0 $二维码$ TESTREPORT ProductName:RoboticPoolCleaner ModelNumber: TYPC1,TalosboC1,C1,**C1(**besingleor multipledigitsbyanyalphabetsand punctuationmarksdenotingdifferentmodel number,brandsandappearanceshape) FCCID:2BN5V-C1 Preparedfor:NanjingTouaRobotTechnologyCo.,Ltd Address:Room501,No.69,ShangQinhuaiStreet,Jiangning District,NanjingCity,JiangsuProvince,China Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China TEL:(0755)26954280 FAX:(0755)26954282 ReportNumber:ENS2602030159W00301R Dateofsamplereceipt:Feb03,2026 Date(s)ofTests:Feb03,2026toMar04,2026 Dateofissue:Mar05,2026 ReportNo.ENS2602030159W00301RPage2of74Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION.....................................................................................................................................................3 2EUTTECHNICALDESCRIPTION.....................................................................................................................................................5 3SUMMARYOFTESTRESULT...........................................................................................................................................................6 4TESTMETHODOLOGY.......................................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS.............................................................................................................7 4.2MEASUREMENTEQUIPMENTUSED..........................................................................................................................................7 4.3DESCRIPTIONOFTESTMODES............................................................................................................................................8 5FACILITIESANDACCREDITATIONS............................................................................................................................................9 5.1FACILITIES...........................................................................................................................................................................9 5.2EQUIPMENT.............................................................................................................................................................................9 5.3LABORATORYACCREDITATIONSANDLISTINGS.................................................................................................................9 6TESTSYSTEMUNCERTAINTY.......................................................................................................................................................10 7SETUPOFEQUIPMENTUNDERTEST..........................................................................................................................................11 7.1RADIOFREQUENCYTESTSETUP1....................................................................................................................................11 7.2RADIOFREQUENCYTESTSETUP2....................................................................................................................................11 7.3CONDUCTEDEMISSIONTESTSETUP..................................................................................................................................13 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM.......................................................................................................14 7.5SUPPORTEQUIPMENT...........................................................................................................................................................14 8FREQUENCYHOPPINGSYSTEMREQUIREMENTS..........................................................................................................................15 8.1StandardApplicable......................................................................................................................................................15 8.2EUTPseudorandomFrequencyHoppingSequence....................................................................................................15 8.3EqualHoppingFrequencyUse......................................................................................................................................16 8.4FrequencyHoppingSystem............................................................................................................................................16 9TESTREQUIREMENTS...................................................................................................................................................................17 9.120DB&99%BANDWIDTH...........................................................................................................................................................17 9.2CARRIERFREQUENCYSEPARATION....................................................................................................................................29 9.3NUMBEROFHOPPINGFREQUENCIES..................................................................................................................................32 9.4AVERAGETIMEOFOCCUPANCY(DWELLTIME)...............................................................................................................35 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER.....................................................................................................................45 9.6CONDUCTEDSUPRIOUSEMISSION......................................................................................................................................51 9.7RADIATEDSPURIOUSEMISSION........................................................................................................................................61 9.8CONDUCTEDEMISSIONTEST....................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ENS2602030159W00301RPage41of74Ver.1.0 2DH5-Ant1-Hop-PASS ReportNo.ENS2602030159W00301RPage42of74Ver.1.0 3DH1-Ant1-Hop-PASS ReportNo.ENS2602030159W00301RPage43of74Ver.1.0 3DH3-Ant1-Hop-PASS ReportNo.ENS2602030159W00301RPage44of74Ver.1.0 3DH5-Ant1-Hop-PASS ReportNo.ENS2602030159W00301RPage45of74Ver.1.0 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER 9.5.1ApplicableStandard AccordingtoFCCPart15.247(b)(1)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-247.5.4andRSS-Gen6.12 9.5.2ConformanceLimit ThemaxForfrequencyhoppingsystemsoperatinginthe2400-2483.5MHzbandemployingatleast75 non-overlappinghoppingchannels:1watt.Forallotherfrequencyhoppingsystemsinthe2400-2483.5MHzband: 0.125watts. 9.5.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.5.4TestProcedure Asanalternativetoapeakpowermeasurement,compliancewiththelimitcanbebasedonameasurementofthe maximumconductedoutputpower. Usethefollowingspectrumanalyzersettings: SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel(about8MHz) SetRBW>the20dBbandwidthoftheemissionbeingmeasured(about3MHz) SetVBW  RBW SetSweep=auto SetDetectorfunction=peak SetTrace=maxhold Allowthetracetostabilize.Usethemarker-to-peakfunctiontosetthemarkertothepeakoftheemissionto determinethepeakamplitudelevel. TestResults Temperature: 25 ̊C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Test Mode AntennaFrequency[MHz] ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict DH5Ant12402-1.56≤20.97PASS DH5Ant12441-1.69≤20.97PASS DH5Ant12480-0.12≤20.97PASS 2DH5Ant124020.62≤20.97PASS 2DH5Ant124410.55≤20.97PASS 2DH5Ant124801.93≤20.97PASS 3DH5Ant124020.89≤20.97PASS 3DH5Ant124410.87≤20.97PASS 3DH5Ant124802.26≤20.97PASS ReportNo.ENS2602030159W00301RPage46of74Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2441-PASS ReportNo.ENS2602030159W00301RPage47of74Ver.1.0 DH5-Ant1-2480-PASS 2DH5-Ant1-2402-PASS ReportNo.ENS2602030159W00301RPage48of74Ver.1.0 2DH5-Ant1-2441-PASS 2DH5-Ant1-2480-PASS ReportNo.ENS2602030159W00301RPage49of74Ver.1.0 3DH5-Ant1-2402-PASS 3DH5-Ant1-2441-PASS ReportNo.ENS2602030159W00301RPage50of74Ver.1.0 3DH5-Ant1-2480-PASS ReportNo.ENS2602030159W00301RPage51of74Ver.1.0 9.6CONDUCTEDSUPRIOUSEMISSION 9.6.1ApplicableStandard AccordingtoFCCPart15.247(d)andKDB558074D0115.247MEASGUIDANCEv05r02 AccordingtoICRSS-2475.5 9.6.2ConformanceLimit Inany100kHzbandwidthoutsidethefrequencybandinwhichthespreadspectrumintentionalradiatoris operating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbeatleast20dBbelowthat inthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,basedoneitheran RFconducted,providedthetransmitterdemonstratescompliancewiththepeakconductedpowerlimits. 9.6.3TestConfiguration Testaccordingtoclause7.1radiofrequencytestsetup1 9.6.4TestProcedure Thetransmitteroutput(antennaport)wasconnectedtothespectrumanalyzer Referencelevelmeasurement Establishareferencelevelbyusingthefollowingprocedure: SetinstrumentcenterfrequencytoDSSchannelcenterfrequency. SetSpan=approximately5timesthe20dBbandwidth,centeredonahoppingchannel. SettheRBW=100kHz.SettheVBW≥3xRBW. SetDetector=peak.SetSweeptime=autocouple. SetTracemode=maxhold.Allowtracetofullystabilize. UsethepeakmarkerfunctiontodeterminethemaximumMaximumconducetedlevel. Notethatthechannelfoundtocontainthemaximumconducetedlevelcanbeusedtoestablishthereference level. Band-edgemeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeakleveloftheemissionoperatingonthechannelclosesttotheband-edge, aswellasanymodulationproductswhichfalloutsideoftheauthorizedbandofoperation SetRBW  1%ofthespan=100kHzSetVBW  3xRBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkerontheemissionatthebandedge,oronthehighestmodulation productoutsideoftheband,ifthislevelisgreaterthanthatatthebandedge.Enablethemarker-deltafunction, thenusethemarker-to-peakfunctiontomovethemarkertothepeakofthein-bandemission.Themarker-delta valuenowdisplayedmustcomplywiththelimitspecifiedinthisSection. Now,usingthesameinstrumentsettings,enablethehoppingfunctionoftheEUT.Allowthetracetostabilize. Followthesameprocedurelistedabovetodetermineifanyspuriousemissionscausedbythehoppingfunction alsocomplywiththespecifiedlimit. Emissionlevelmeasurement Usethefollowingspectrumanalyzersettings: Span=wideenoughtocapturethepeaklevelofthein-bandemissionandallspuriousemissions(e.g.,harmonics) fromthelowestfrequencygeneratedintheEUTupthroughthe10thharmonic.(30MHzto25GHz).SetRBW= 100kHzSetVBW  RBW SetSweep=autoSetDetectorfunction=peakSetTrace=maxhold Allowthetracetostabilize.Setthemarkeronthepeakofanyspuriousemissionrecorded.Theleveldisplayed mustcomplywiththelimitspecifiedinthisSection. ReportNo.ENS2602030159W00301RPage52of74Ver.1.0 9.6.5TestResults Temperature: 25 ̊ C RelativeHumidity:45% ATMPressure:1011mbar Note:N/A Alltheantennaandmodesmodehavebeentested,andtheworstresultrecordedwasreportasbelow: Bandedgemeasurements TestModeAntennaChNameFrequency[MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1Low2402-2.42-47.41≤-22.42PASS DH5Ant1High2480-0.44-48.37≤-20.44PASS DH5Ant1LowHop_2402-2.32-47.85≤-22.32PASS DH5Ant1HighHop_2480-3.46-47.39≤-23.46PASS ReportNo.ENS2602030159W00301RPage53of74Ver.1.0 DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS ReportNo.ENS2602030159W00301RPage54of74Ver.1.0 DH5-Ant1-Hop_2402-PASS DH5-Ant1-Hop_2480-PASS ReportNo.ENS2602030159W00301RPage55of74Ver.1.0 ConductedSpuriousEmission TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant124020~Reference-2.60-2.60---PASS DH5Ant1240230~1000-2.60-53.14≤-22.6PASS DH5Ant124021000~26500-2.60-46.23≤-22.6PASS DH5Ant124410~Reference-2.53-2.53---PASS DH5Ant1244130~1000-2.53-51.91≤-22.53PASS DH5Ant124411000~26500-2.53-48.48≤-22.53PASS DH5Ant124800~Reference-0.90-0.90---PASS DH5Ant1248030~1000-0.90-53.15≤-20.9PASS DH5Ant124801000~26500-0.90-49.27≤-20.9PASS ReportNo.ENS2602030159W00301RPage56of74Ver.1.0 DH5-Ant1-2402-0~Reference-PASS DH5-Ant1-2402-30~1000-PASS R…

Text truncated - open the document above for the full version.

Test Report

1 SPECIFICATIONFORAPPROVAL Nameofthecompany : Nameofanarticle : 2.4GPCBantenna Materialcode : HX-PCB24-379-120B1 Customeritemnumber : Specifications:Seethespecification Date : 2023-01-03 Customercountersignature: DepartmentofEngin eering QualitydepartmentApprove ShenzhenhongxintechnologyelectronicsCo.Ltd: DepartmentofEngin eering QualitydepartmentApprove ZhuangWeifengZhangHuanLiuLu 2 One:antennaparameters DesignSpecificationsTypicalUnits AntennaformPCBantenna workingFrequency2400-2500MHZ GainDB2.33i Antennaefficiency35~80% VSWR<1.8 Ploriaztionverticalpolarization 辐射方向(Radiationpattern)omnidirection impedance50ohm Powerhandling33dbm InterfaceIPEX-1 Overaldimensions37*9mm WeightNorequirement OperatinTemp-30-70°C StoringTemp-30-70°C 3 Two: Antennaphysicaldiagram Fill:1.Theantennaparametersaretestedaccordingtothesimula tedenvironment,andtherewillbeperformancedeviationsfordi fferentproducts. 2.Thefunctionoftheantennaissensitive.Pleaseinformusto evaluateifthereisanychangeintheperipheralstructureof themainbody. Three:VSWR/ReturnLoss/SmithChart/AntennaPattern/Gainand efficiency VSWR 4 ReturnLoss SmithChart 5 AntennaPattern Gainandefficiency four : Storageenvironment Workingtemperature :-30to70 º C reservetemperature :-30to70 º C 6 five : D imensions HX-PCB24-379-120B1 .000 ±0.05 GENERAL TOLERANCE DIMENTION .0 .00 . ±0.15 ±0.10 ±0.20 .0 .00 ANGLES . ±1° ±1° ±2° T 37±0.3 9±0.3 3 2 120±2 1 4 Media number Total number of old basemap Total number of basemap Date Sign Yan qinghua 1 page in total Serial No Name Specifications/Color 1RF cable RF1.13/Black 2backHPr 3 base material PCB 4IPEX-1 B1/golden mm 1:1 Charting Trace Width Unit: Proportion: Material: General processing: Surface roughness Surface treatment Name: Dash number: Approve: Check:Radio frequency: Draw: Design: Color: Quantity: Page 1

Test Setup Photos

ReportNo.ENS2602030159W003Page1of2Ver.1.0 FCCID:2BN5V-C1 ReportNo.ENS2602030159W003Page2of2Ver.1.0

Contact Information

Applicant

Bin ma
[email protected]Fax: N/A

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, · Saint Charles, Illinois, 60174 · United States

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.68 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.