FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TELICA Inc./
  3. 2BN7U-AP6256

2BN7U-AP6256WLAN Module

TELICA Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 13, 2026
Application Purpose
Original Equipment
Equipment Note
WLAN Module
Frequency Range
2412.00000000 - 2462.00000000
Company
TELICA Inc.
Country
South Korea

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

TELICA Inc. Covered Equipment Certification Attestation Letter 4/24/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BN7U-AP6256 TELICA Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes certifying that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. TELICA Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Aaron Kim Title: Principal Research Engineer Company Name: TELICA Inc. Date: 4/24/2026

Attestation Statements

TELICA Inc. * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter May 11, 2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2BN7U-AP6256 Per section 2.911(d)(7) of the FCC rules, TELICA Inc. (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. Designated agent* for service of process: Company Name: Ascendant Alliance Partners Physical U.S. Company Address: 154 Brindle Lane Alpharetta Georgia, 30009, United States Agent name: John Shin Agent Email Address: [email protected] FRN: 0036821205 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant): Signed: Signed: Printed name: Aaron Kim Printed name: John Shin Title: Principal Research Engineer Title: Managing Director Company Name: TELICA Inc. Company Name: Ascendant Alliance Partners Date: May 6, 2026 Date: May 6, 2026

Cover Letter(s)

TELICA Inc. 4/24/2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint ONETECH Corp., to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Signed: Printed name: Aaron Kim

Cover Letter(s)

TELICA Inc. May 11, 2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2BN7U-AP6256 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Aaron Kim Title: Principal Research Engineer Company Name: TELICA Inc.

Cover Letter(s)

TELICA Inc. Date (24/04/2026) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Modular Approval Request FCC ID: 2BN7U-AP6256 The following attestation addresses the requirements to support modular approval: Modular approval requirement Yes (provide brief statement) No * (a) The radio elements must have the radio frequency circuitry shielded. Physical components and tuning capacitor(s) may be located external to the shield, but must be on the module assembly Refer to the external photo (b) The module must have buffered modulation/data inputs to ensure that the device will comply with Part 15 requirements with any type of input signal All input to the modules are buffered through microprocessor inputs. (c) The module must contain power supply regulation on the module Internal power regulators Refer to the Block-diagram (d) The module must contain a permanently attached antenna, or contain a unique antenna connector, and be marketed and operated only with specific antenna(s), per Sections 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b) Refer to the internal photo (e) The module must demonstrate compliance in a stand-alone configuration The EUT was tested in a standalone configuration via a SD extension cable Refer to the test setup photo (f) The module must be labelled with its permanently affixed FCC ID label, or use an electronic display (See KDB Publication 784748 about labelling requirements) Refer to the external photo (g) The module must comply with all specific rules applicable to the transmitter. The grantee must provide comprehensive instructions to explain compliance requirements Refer to the user manual Modular approval requirement Yes (provide brief statement) No * (h) The module must comply with RF exposure requirements Refer to the RF exposure statement for more details. * Please provide a detailed explanation if the answer is “No.” Sincerely, Signed: Printed name: Aaron Kim Title: Principal Research Engineer

ID Label/Location Info

Page 1 of 1 IDENTIFICATION LABEL: PROPOSED LABEL The shall be permanently affixed in the rear side of the equipment

RF Exposure Info

Page 1 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMF TEST REPORT Test Report No. : OT-264-RWD-060 Reception No. : 2602000614 Applicant : TELICA Inc. Address : Tower A-411, 40 Imi-ro, Uiwang-Si, Gyeonggi-do, 16006, South Korea Manufacturer : AMPAK Technology Inc. Address : 6F., No.23, Hunake 1st Rd., Zubei City, Hsinchu Country 302047, Taiwan Type of Equipment : WLAN Module FCC ID. : 2BN7U-AP6256 Model Name : TE-AP6256 Multiple Model Name : N/A Serial number : N/A Total page of Report : 7 pages (including this page) Date of Incoming : March 16, 2026 Date of issue : April 24, 2026 SUMMARY The equipment complies with the regulation; CFR §2.1091 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. This test report is not associated with the accreditation granted by the Korean Laboratory Accreditation Scheme (KOLAS). Tested by Ye-Bhin, Park / Project Engineer ONETECH Corp. Reviewed by Tae-Ho, Kim / Chief Engineer ONETECH Corp. Approved by Jae-Ho, Lee / Director ONETECH Corp. Page 2 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS Page 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 4 2. GENERAL INFORMATION ............................................................................................................................................ 5 2.1 PRODUCT DESCRIPTION ................................................................................................................................................. 5 2.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 5 3. MAXIMUM PERMISSIBLE EXPOSURE ...................................................................................................................... 6 3.1 LIMIT AND CALCULATION METHOD ................................................................................................................. 6 4. MPE Calculations ............................................................................................................................................................... 7 5. CALCULATED RESULTS ............................................................................................................................................... 7 5.1 LIMIT AND CALCULATION .................................................................................................................................... 7 Page 3 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) Revision History Rev. No. Issue Report No. Issued Date Revisions Section Affected 0 OT-264-RWD-060 April 24, 2026 Initial Release All Page 4 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 1. VERIFICATION OF COMPLIANCE Applicant : TELICA Inc. Address : Tower A-411, 40 Imi-ro, Uiwang-Si, Gyeonggi-do, 16006, South Korea Contact Person : Aaron, Kim / Principal Research Engineer Telephone No. : +82-10-9580-1067 FCC ID : 2BN7U-AP6256 Model Name : TE-AP6256 Brand Name : - Serial Number : N/A Date : April 24, 2026 E.U.T. DESCRIPTION Modular Transmitter, WLAN Module THIS REPORT CONCERNS Original Grant MEASUREMENT PROCEDURES KDB 447498 D01 General RF Exposure Guidance v06 TYPE OF EQUIPMENT TESTED Pre-Production KIND OF EQUIPMENT AUTHORIZATION REQUESTED Certification Modifications on the Equipment to Achieve Compliance None -. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 5 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 2. GENERAL INFORMATION 2.1 Product Description The TELICA Inc., Model TE-AP6256 (referred to as the EUT in this report) is a WLAN Module. The product specification described herein was obtained from product data sheet or user’s manual. DEVICE TYPE WLAN Module Temperature Range -30 °C ~ 85 °C OPERATING FREQUENCY WLAN 2.4 GHz 2 412 MHz ~ 2 462 MHz (802.11b/g/n(HT20)) MODULATION TYPE WLAN 2.4 GHz 802.11b: DSSS Modulation(DBPSK/DQPSK/CCK) 802.11g/n(HT20): OFDM Modulation(BPSK/QPSK/16QAM/64QAM) ANTENNA TYPE PCB Antenna List of each Osc. or crystal Freq.(Freq. >= 1 MHz) 32.768 kHz, 37.4 MHz 2.2 Alternative type(s)/model(s); also covered by this test report. -. None Page 6 of 7 Report No.: OT-264-RWD-060 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 3. MAXIMUM PERMISSIBLE EXPOSURE 3.1 LIMIT AND CALCUL…

Text truncated - open the document above for the full version.

Test Report

Appendix Data 1. DUTY CYCLE 2. MINIMUM 6 DB BANDWIDTH 3. 99% OCCUPIED BANDWIDTH 4. PEAK POWER SPECTRAL DENSITY 5. 100 KHZ BANDWIDTH OUTSIDE THE FREQUENCY BAND 6. RADIATED EMISSION Test ItemNo.ModeChannelBandwitdh RU ToneRB indexVerdict Duty Cycle 1b2412 20 MHz --Pass Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 Duty Cycle Test ItemNo.ModeChannelBandwitdh RU ToneRB indexVerdict Duty Cycle 1g2412 20 MHz --Pass Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 Duty Cycle Test ItemNo.ModeChannelBandwitdh RU ToneRB indexVerdict Duty Cycle 1 n(HT20) 2412 20 MHz --Pass Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 Duty Cycle Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1b241220 MHz--Pass 2b243720 MHz--Pass 3b246220 MHz--Pass 6dB BW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 6dB BW 6dB BW 3 6dB BW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1g241220 MHz--Pass 2g243720 MHz--Pass 3g246220 MHz--Pass 6dB BW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 6dB BW 6dB BW 3 6dB BW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1n(HT20)241220 MHz--Pass 2n(HT20)243720 MHz--Pass 3n(HT20)246220 MHz--Pass 6dB BW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 6dB BW 6dB BW 3 6dB BW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1b241220 MHz--Pass 2b243720 MHz--Pass 3b246220 MHz--Pass OBW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 OBW OBW 3 OBW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1g241220 MHz--Pass 2g243720 MHz--Pass 3g246220 MHz--Pass OBW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 OBW OBW 3 OBW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1n(HT20)241220 MHz--Pass 2n(HT20)243720 MHz--Pass 3n(HT20)246220 MHz--Pass OBW Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 OBW OBW 3 OBW Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1b241220 MHz--Pass 2b243720 MHz--Pass 3b246220 MHz--Pass PSD Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 PSD PSD 3 PSD Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1g241220 MHz--Pass 2g243720 MHz--Pass 3g246220 MHz--Pass PSD Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 PSD PSD 3 PSD Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1n(HT20)241220 MHz--Pass 2n(HT20)243720 MHz--Pass 3n(HT20)246220 MHz--Pass PSD Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 PSD PSD 3 PSD Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1b241220 MHz--Pass 2b241220 MHz--Pass 3b241220 MHz--Pass 4b243720 MHz--Pass 5b243720 MHz--Pass 6b243720 MHz--Pass 7b246220 MHz--Pass 8b246220 MHz--Pass 9b246220 MHz--Pass 100 kHz BW Outside Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 100 kHz BW Outside 100 kHz BW Outside 3 4 100 kHz BW Outside 100 kHz BW Outside 5 6 100 kHz BW Outside 100 kHz BW Outside 7 8 100 kHz BW Outside 100 kHz BW Outside 9 100 kHz BW Outside Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1g241220 MHz--Pass 2g241220 MHz--Pass 3g241220 MHz--Pass 4g243720 MHz--Pass 5g243720 MHz--Pass 6g243720 MHz--Pass 7g246220 MHz--Pass 8g246220 MHz--Pass 9g246220 MHz--Pass 100 kHz BW Outside Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 100 kHz BW Outside 100 kHz BW Outside 3 4 100 kHz BW Outside 100 kHz BW Outside 5 6 100 kHz BW Outside 100 kHz BW Outside 7 8 100 kHz BW Outside 100 kHz BW Outside 9 100 kHz BW Outside Test ItemNo.ModeChannelBandwitdhRU ToneRB indexVerdict 1n(HT20)241220 MHz--Pass 2n(HT20)241220 MHz--Pass 3n(HT20)241220 MHz--Pass 4n(HT20)243720 MHz--Pass 5n(HT20)243720 MHz--Pass 6n(HT20)243720 MHz--Pass 7n(HT20)246220 MHz--Pass 8n(HT20)246220 MHz--Pass 9n(HT20)246220 MHz--Pass 100 kHz BW Outside Test BandWLAN_2.4GHz_SISO AntennaANT0 Test Parameters for Channel Bandwidths 1 2 100 kHz BW Outside 100 kHz BW Outside 3 4 100 kHz BW Outside 100 kHz BW Outside 5 6 100 kHz BW Outside 100 kHz BW Outside

Test Report

5 6 Harmonic Harmonic 7 8 Harmonic Harmonic 9 10 Harmonic Harmonic 11 12 Harmonic Harmonic 13 14 Harmonic Harmonic 15 16 Harmonic Harmonic 17 18 Harmonic Harmonic 19 20 Harmonic Harmonic 21 22 Harmonic Harmonic 23 24 Harmonic Harmonic Test ItemNo.ModeFrquencyBandwidthDetectorHarmonicPolarization Harmonic1802.11 n(HT20)4824 20 MHz AVG2Horizontal Harmonic2802.11 n(HT20)4824 20 MHz PEAK2Horizontal Harmonic3802.11 n(HT20)4824 20 MHz AVG2Vertical Harmonic4802.11 n(HT20)4824 20 MHz PEAK2Vertical Harmonic5802.11 n(HT20)7236 20 MHz AVG3Horizontal Harmonic6802.11 n(HT20)7236 20 MHz PEAK3Horizontal Harmonic7802.11 n(HT20)7236 20 MHz AVG3Vertical Harmonic8802.11 n(HT20)7236 20 MHz PEAK3Vertical Harmonic9802.11 n(HT20)4874 20 MHz AVG2Horizontal Harmonic10802.11 n(HT20)4874 20 MHz PEAK2Horizontal Harmonic11802.11 n(HT20)4874 20 MHz AVG2Vertical Harmonic12802.11 n(HT20)4874 20 MHz PEAK2Vertical Harmonic13802.11 n(HT20)7311 20 MHz AVG3Horizontal Harmonic14802.11 n(HT20)7311 20 MHz PEAK3Horizontal Harmonic15802.11 n(HT20)7311 20 MHz AVG3Vertical Harmonic16802.11 n(HT20)7311 20 MHz PEAK3Vertical Harmonic17802.11 n(HT20)4924 20 MHz AVG2Horizontal Harmonic18802.11 n(HT20)4924 20 MHz PEAK2Horizontal Harmonic19802.11 n(HT20)4924 20 MHz AVG2Vertical Harmonic20802.11 n(HT20)4924 20 MHz PEAK2Vertical Harmonic21802.11 n(HT20)7386 20 MHz AVG3Horizontal Harmonic22802.11 n(HT20)7386 20 MHz PEAK3Horizontal Harmonic23802.11 n(HT20)7386 20 MHz AVG3Vertical Harmonic24802.11 n(HT20)7386 20 MHz PEAK3Vertical Test BandWLAN_2GHz AntennaANT 0 Test Parameters 1 2 Harmonic Harmonic 3 4 Harmonic Harmonic 5 6 Harmonic Harmonic 7 8 Harmonic Harmonic 9 10 Harmonic Harmonic 11 12 Harmonic Harmonic 13 14 Harmonic Harmonic 15 16 Harmonic Harmonic 17 18 Harmonic Harmonic 19 20 Harmonic Harmonic 21 22 Harmonic Harmonic 23 24 Harmonic Harmonic Test ItemNo.ModeChannelBandwitdhDetectorPolarization Restricted Band1802.11 b241220MHzAVGHorizontal Restricted Band2802.11 b241220MHzPEAKHorizontal Restricted Band3802.11 b241220MHzAVGVertical Restricted Band4802.11 b241220MHzPEAKVertical Restricted Band5802.11 b246220MHzAVGHorizontal Restricted Band6802.11 b246220MHzPEAKHorizontal Restricted Band7802.11 b246220MHzAVGVertical Restricted Band8802.11 b246220MHzPEAKVertical AntennaANT 0 Test Parameters Test BandWLAN_2GHz 1 2 Restricted Band Restricted Band 3 4 Restricted Band Restricted Band 5 6 Restricted Band Restricted Band 7 8 Restricted Band Restricted Band Test ItemNo.ModeChannelBandwitdhDetectorPolarization Restricted Band1802.11 g241220 MHzAVGHorizontal Restricted Band2802.11 g241220 MHzPEAKHorizontal Restricted Band3802.11 g241220 MHzAVGVertical Restricted Band4802.11 g241220 MHzPEAKVertical Restricted Band5802.11 g246220 MHzAVGHorizontal Restricted Band6802.11 g246220 MHzPEAKHorizontal Restricted Band7802.11 g246220 MHzAVGVertical Restricted Band8802.11 g246220 MHzPEAKVertical Test BandWLAN_2GHz AntennaANT 0 Test Parameters 1 2 Restricted Band Restricted Band 3 4 Restricted Band Restricted Band 5 6 Restricted Band Restricted Band 7 8 Restricted Band Restricted Band Test ItemNo.ModeChannelBandwitdhDetectorPolarization Restricted Band1802.11 n(HT20)241220 MHzAVGHorizontal Restricted Band2802.11 n(HT20)241220 MHzPEAKHorizontal Restricted Band3802.11 n(HT20)241220 MHzAVGVertical Restricted Band4802.11 n(HT20)241220 MHzPEAKVertical Restricted Band5802.11 n(HT20)246220 MHzAVGHorizontal Restricted Band6802.11 n(HT20)246220 MHzPEAKHorizontal Restricted Band7802.11 n(HT20)246220 MHzAVGVertical Restricted Band8802.11 n(HT20)246220 MHzPEAKVertical Test BandWLAN_2GHz AntennaANT 0 Test Parameters 1 2 Restricted Band Restricted Band 3 4 Restricted Band Restricted Band 5 6 Restricted Band Restricted Band 7 8 Restricted Band Restricted Band

Test Report

1 Confidential Antenna Location Pattern Antenna < Antenna side >< Antenna opposite > Pattern Antenna 2 Confidential Patten Antenna x y z 2. 3D Result Summary 1. Antenna Axis Direction Freq.[GHz] θ-Pol(H)φ-Pol(V) Eff.[%]Avg.[dBi]Peak[dBi]θ[deg]φ[deg]Eff.[%]Avg.[dBi]Peak[dBi]θ[deg]φ[deg] 2.413.98-8.543.4618024028.97-5.382.81180330 2.4116.71-7.774.2318024034.67-4.63.49180315 2.4216.81-7.754.2518024035.27-4.533.31180345 2.4318.34-7.374.6318024039.17-4.073.7180315 2.4419.78-7.044.9818024042.1-3.763.94180150 2.4518.84-7.254.8918024041.15-3.863.82180315 2.4617.05-7.684.618024038.61-4.133.51180315 2.4718.29-7.384.918024041.99-3.773.92180330 2.4817.77-7.54.7318024040.47-3.933.72180330 2.4919.22-7.164.9818024043.7-3.64.08180315 2.518.86-7.244.8418024042.31-3.743.95180315 3 Confidential 3. Radiation Pattern Pattern Antenna

Test Report

Page 1 of 42 Report No.: OT-264-RWD-059 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) RADIO PERFORMANCE TEST REPORT Test Report No. : OT-264-RWD-059 Reception No. : 2602000614 Applicant : TELICA Inc. Address : Tower A-411, 40 Imi-ro, Uiwang-Si, Gyeonggi-do, 16006, South Korea Manufacturer : AMPAK Technology Inc. Address : 6F., No.23, Hunake 1st Rd., Zubei City, Hsinchu Country 302047, Taiwan Type of Equipment : WLAN Module FCC ID. : 2BN7U-AP6256 Model Name : TE-AP6256 Multiple Model Name : N/A Serial number : N/A Total page of Report : 42 pages (including this page) Date of Incoming : March 16, 2026 Date of issue : April 24, 2026 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. This test report is not associated with the accreditation granted by the Korean Laboratory Accreditation Scheme (KOLAS). Tested by Ye-Bhin, Park / Project Engineer ONETECH Corp. Reviewed by Tae-Ho, Kim / Chief Engineer ONETECH Corp. Approved by Jae-Ho, Lee / Director ONETECH Corp. Page 2 of 42 Report No.: OT-264-RWD-059 It should not be reproduced except in full, without the written approval of ONETECH Corp. OTC-TRF-RF-001(0) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS Page 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 5 2. TEST SUMMARY .............................................................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 3.2 ANTENNA CONFIGURATIONS ......................................................................................................................................... 8 3.3 MAXIMUM OUTPUT POWER .......................................................................................................................................... 9 3.4 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 9 4. EUT MODIFICATIONS .................................................................................................................................................... 9 5. SYSTEM TEST CONFIGURATION ............................................................................................................................. 10 5.1 JUSTIFICATION ............................................................................................................................................................. 10 5.2 PERIPHERAL EQUIPMENT ............................................................................................................................................ 10 5.3 MODE OF OPERATION DURING THE TEST .................................................................................................................... 11 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................. 12 5.5 ANTENNA REQUIREMENT ............................................................................................................................................ 12 6. MEASUREMENT UNCERTAINTY .............................................................................................................................. 13 7. PRELIMINARY TEST .................................................................................................................................................... 13 7.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ....................................................................................................... 13 7.2 GENERAL RADIATED EMISSIONS TESTS ..................................................................................................................... 13 7.3 LIST OF TEST EQUIPMENT ................................................................................................................................... 14 8. DESCRIPTION OF TEST ............................................................................................................................................... 15 8.1 DUTY CYCLE…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Aaron Kim(Principal Research Engineer)
[email protected]Fax: -

Technical Contact

Ascendant Alliance PartnersJohn Shin
[email protected]

154 Brindle Lane · Alpharetta, 30009 · United States

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz34.52 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Approval. Output power listed is conducted. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing and authorization process as required. The module shall only be used with the internal on-board antenna which has been tested and certified with this module. External antennas are not supported. The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical assessment to the FCC rules, including the transmitter operation and should refer to guidance in KDB 996369.

Other Applications from TELICA Inc.

2BN7U-MS200

Zigbee Module

Apr 16, 2026

Equipment Class

DTS - Digital Transmission System