Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Oddy Idea LLC Certification Designating Applicant as FCC US Agent To: Federal Communications Commission Date: 10/4/2025 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BNF7-9275 Oddy Idea LLC (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledge the applicant’s consent and the designated agent for service of process’s obligation to accept service of process. The applicant acknowledge the applicant’s acceptance to maintain an agent for service of process for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledge the responsibility to inform the FCC whenever the agent information changes. Designated U.S. Agent from Applicant Company Company Name: Oddy Idea LLC Contact Person: Michael Campaignio Address: 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 Tel.: 302-656-1950 Email: [email protected] FCC FRN: Sincerely yours, (Signature) Name: Michael Campaignio Title: President 0036521672
Oddy Idea LLC Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 10/4/2025 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BNF7-9275 Oddy Idea LLC / 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 (“the applicant”) certifies that, a s of the date of the filing of the application, the applicant is not identified on the Covered List ( as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, By: _ ____ _Michael Campaignio, President___ (Signature) (Name) Tel: 302-656-1950 Email: [email protected]
Oddy Idea LLC Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 10/4/2025 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BNF7-9275 Oddy Idea LLC / 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 (“the applicant”) certifies that t he equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely, By: _ ____ Michael Campaignio, President___ (Signature) (Name) Tel: 302-656-1950 Email: [email protected]
Page 1 of 1 Authority to Act as Agent Date: 10/4/2025 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint __ TUV Rheinland (Shenzhen) Co., Ltd. _to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with _Oddy Idea LLC / 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826____. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: ________12 Months_______ Agreement is valid for 12 months from the above date. By: _ ____ Michael Campaignio ____ (Signature) (Print name) President _ ___ 302-656-1950 ____ (Title) (Telephone) On behalf of: Oddy Idea LLC (Company Name)
TCB FCC Request for Confidentiality Letter Date: 10/4/2025 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BNF7-9275 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction Oddy Idea LLC has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _ ____ _Michael Campaignio, President ____ (Signature) (Name) Tel: 302-656-1950 Email: [email protected]
Page 1 of 1 Declaration Letter for Module Intended Use Date: 2025-06-04 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BNF7-9275 IC: 33468-9275 HVIN: P6G8HZ Model Number: P6G8HZ To Whom It May Concern: We, Oddy Idea LLC, 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 would like to declare: 60 GHz radar transceiver m odule P6G8HZ will sell to specific Television OEM and will be installed and maintained to Television (type: power supplied by AC mains) as the end product only, will not for other products. Also this module will not place on the market for using alone. The OEM will be told each specific host TV shall follw FCC C2PC procedure to ensuring the compliance of the end product. Thank you, By: _ ____ _ Michael Campaignio _ (Signature) (Print name) _President _ 302-656-1950___ _ _ (Title) (Telephone) On behalf of: _Oddy Idea LLC, 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 (Company Name and Address)
Module Approve Request Letter Date: 10/4/2025 FCC ID: 2BNF7-9275, IC: 33468-9275 To whom it may concern: The requirements of KDB 996369 have been met and shown on the following statements. Type of Module: Limited Single Modular Approval No. Requirements Device Conditions Comply (Y/N) 1 The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements. Without Shielding N 2 The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with part 15 requirements under conditions of excessive data rates or over-modulation. Y 3 The modular transmitter must have its own power supply regulation. Y 4 The modular transmitter must comply with the antenna and transmission system requirements of §15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler. Antenna in Radar chip package Y 5 The modular transmitter must be tested in a stand- alone configuration, i.e., the module must not be inside another device during testing for compliance with part 15 requirements. Y 6 The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. Y 7 The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Y 8 The modular transmitter must comply with any applicable RF eeifjcbfvgefeccudkbngrgclbxposure requirements in its final configuration. Y If you have any questions regarding this, please don’t hesitate to contact us. Sincerely, By: _ ____ _ Michael Campaignio, President__ (Signature) (Name) Tel: 302-656-1950 Email: [email protected]
FCC ID: 2BNF7-9275 IC: 33468-9275 P6G8HZ (Label is on the Module PCB)
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25SFXG 002 Auftrags-Nr.: Order no.: 168539771 Seite 1 von 6 Page 1 of 6 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2024-12-16 Auftraggeber: Client: Oddy Idea LLC 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 Prüfgegenstand: Test item: Presence Sensor Module Bezeichnung / Typ-Nr.: Identification / Type no.: P6G8HZ Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: FCC CFR Title 47, Part 2.1091 RSS-102 Issue 6 Wareneingangsdatum: Date of sample receipt: 2024-12-18 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003890968-002 Prüfzeitraum: Testing period: 2024-12-18 to 2025-04-25 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2025-06-09 Ausstellungsdatum: Issue date: 2025-06-09 Stellung / Position: Sachverständige(r) / Expert Stellung / Position: Sachverständige(r) / Expert Sonstiges / Other: FCC ID: 2BNF7-9275 IC: 33468-9275 HVIN: P6G8HZ This report is for stand-alone configuration module P6G8HZ, and additional testing for HOSTs (HOSTs A, B, C, D configurations were tested, refer to Appendix B_CN25SFXG 001 for details of HOST). Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518000, China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25SFXG 002 Test report no.: Seite 2 von 6 Page 2 of 6 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in ac…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25SFXG 001 Auftrags-Nr.: Order no.: 168539771 Seite 1 von 24 Page 1 of 24 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2024-12-16 Auftraggeber: Client: Oddy Idea LLC 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 Prüfgegenstand: Test item: Presence Sensor Module Bezeichnung / Typ-Nr.: Identification / Type no.: P6G8HZ Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: FCC CFR Title 47, Part 15, Subpart C, Section 15.255 RSS-210 Issue 11 RSS-Gen Issue 5 KDB 364244 D01 Meas 15.255 Radars v01 Wareneingangsdatum: Date of sample receipt: 2024-12-18 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003890968-002 Prüfzeitraum: Testing period: 2024-12-18 to 2025-04-25 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2025-06-09 Ausstellungsdatum: Issue date: 2025-06-09 Stellung / Position: Sachverständige(r) / Expert Stellung / Position: Sachverständige(r) / Expert Sonstiges / Other: FCC ID: 2BNF7-9275 IC: 33468-9275 HVIN: P6G8HZ This report is for stand-alone configuration module P6G8HZ, and additional testing for HOSTs (HOSTs A, B, C, D configurations were tested, refer to Appendix B_CN25SFXG 001 for details of HOST). Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518000, China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25SFXG 001 Test report no.: Seite 2 von 24 Page 2 of 24 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in thi…
Text truncated - open the document above for the full version.
Antenna Report FCC ID: 2BNF7-9275 IC: 33468-9275 Oddy Idea LLC 8880 Cal Center Drive, 4th Floor, Sacramento, CA 95826 Module Manufacturer: Infineon Technologies AG Manufacturer of RF IC and Antenna: Am Campeon 1-15 85579 Neubiberg Germany BGT60UTR13D Parameter Value Unit Condition Min. Typ. M·ax. RXr,w 61 GHz Receiver antenna TXaw 61 GHz Transmitter antenna GTX 3.0 dBi Antenna gain of a single TXantenna G,x 3.0 dBi Antenna gain of a single RX antenna HPBWRX..E 120 Deg Half.power beam width of asingle RXantenna in the E-plane direction HPBWRX..H 90 Deg Half.power beam width of asingle RXantenna in the H.plane direction HPBWru 120 Deg Half.power beam width of asingle TX antenna in the E.plane direction HPBWTX..N 90 Deg Half.power beam width of asingle TX antenna in the H.plane direction Operation Descriptions_ATN Gain Operation Descriptions_ATN Gain
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.255 | 57.00 GHz - 61.56 GHz | 6.90 mW |
| 2 | 15.255 | 61.00 GHz - 61.50 GHz | 18.50 mW |