FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HWLT_FZE/
  3. 2BNPTW-103A

2BNPTW-103AWireless Charger

HWLT_FZE

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 28, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Charger
Frequency Range
0.11900000 - 0.20500000
Company
HWLT_FZE
Country
United Arab Emirates

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

HWLT_FZE Section 2.911(d)(7) USA Agent for Service of Process Company name: HWLT_FZE Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates FCC ID: 2BNPTW-103A 2.911(d)(7) USA Designated Agent for Service of Process We, [HWLT_FZE] designate [Linkwld LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Applicant Company name: Linkwld LLC Company name: HWLT_FZE USA Address: 7595 Technology Way Ste 100, Denver, CO 80237, US Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates FRN Number: 0033625682 Grantee FRN Number: 0036660595 Contact Name: Timothy Zhu FCC Grantee Code: 2BNPT Telephone No: (747) 717-2691 Contact Name: Aleksei Deviatkin Email: [email protected] Telephone No: +7 913 398 0235 Email: [email protected] Signature: Title: Manager Signature: Title: Manager Date: 2026-07-13 Date: 2026-07-13 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nationa l-security-threats-to-the-communications-supply-chain-through-the 2.911 (d)(7)USA Agent v1.5

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: HWLT_FZE Grantee code: 2BNPT FCC ID: 2BNPTW-103A FRN: 0036660595 Contact Name: Aleksei Deviatkin Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Telephone No:+7 913 398 0235 Fax No: / Email: [email protected] i. [HWLT_FZE] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [HWLT_FZE] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [HWLT_FZE] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: August 24, 2026 Applicant’s Name: Aleksei Deviatkin Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

HWLT_FZE Code 00018768 Ed. 1 Item 1. The device is able to install software/program installation? ☐ Yes, go to Item 2. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A Device Wireless Charger Company name HWLT_FZE Grantee code 2BNPT FCC ID 2BNPTW-103A FRN 0036660595 Contact name Aleksei Deviatkin Address Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Telephone number +7 913 398 0235 E-mail [email protected] Chipset/module information SWH4610 Operating System (if applicable) N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 3 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; N/A After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software 4 Item 3. Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: Aleksei Deviatkin Date: August 24, 2026 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

TCB CALL página 1 File FCC ID: 2BNPTW-103A Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : Search | coloradosos.gov TCB CALL página 2 TCB CALL página 3 TCB CALL página 4 TCB CALL página 5 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 HWLT_FZE OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026-08-24 Subject:RequestforConfidentiality FCCID:2BNPTW-103A ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-TermConfidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☒ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☒ User’sManual ☐ NOTE 1 ☒ InternalPhotos ☐ NOTE 1 ☒ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselectedabove arewithheldfrompublicviewforaperiodof___180___daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Name:AlekseiDeviatkin Title:Manager 2026/8/24

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization HWLT_FZE Company: HWLT_FZE Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Product Name: Wireless Charger Model Number: W-103A FCC Identifier: 2BNPTW-103A We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Aleksei Deviatkin Date: August 24, 2026 Title: Manager Signature of applicant:

ID Label/Location Info

center Interface FCC ID:2BNPTW-103A FCC ID:2BNPTW-103A 2 2

RF Exposure Info

Page 1 of 10 Code:AB-RF-05-b FCC Test Report Report No.:1812C60379812502 Applicant:HWLT_FZE Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Product Name:Wireless Charger Report Date:2026-08-24 Shenzhen Anbotek Compliance Laboratory Limited #资质章# #检测章# #报告二维码# Report No.: 1812C60379812502 Page 2 of 10 FCC ID: 2BNPTW-103A Code:AB-RF-05-b Contents 1. General Information ............................................................................................................................5 1.1. Client Information ......................................................................................................................5 1.2. Description of Device (EUT) .....................................................................................................5 1.3. Auxiliary Equipment Used During Test .....................................................................................6 1.4. Description of Test Modes ........................................................................................................6 1.5. Test Equipment List ..................................................................................................................6 1.6. Measurement Uncertainty .........................................................................................................6 1.7. Description of Test Facility ........................................................................................................7 1.8. Disclaimer .................................................................................................................................7 2. Measurement and Result ....................................................................................................................8 2.1. Limits For Maximum Permissible Exposure (MPE)...................................................................8 2.2. Test Setup.................................................................................................................................8 2.3. Test Procedure .........................................................................................................................9 2.4. Test Result ................................................................................................................................9 APPENDIX I -- TEST SETUP PHOTOGRAPH .....................................................................................10 APPENDIX II -- EXTERNAL PHOTOGRAPH .......................................................................................10 APPENDIX III -- INTERNAL PHOTOGRAPH .......................................................................................10 Report No.: 1812C60379812502 Page 3 of 10 FCC ID: 2BNPTW-103A Code:AB-RF-05-b TEST REPORT Applicant:HWLT_FZE Manufacturer:Dongguan Agilian Technologies Co., Ltd Product Name:Wireless Charger Model No.:W-103A Trade Mark: ERA Rating(s): Input: 5V⎓2A Wireless Charging Output: 5W Test Standard(s): FCC Part 1.1310, 1.1307(b), FCC Part 2.1091 Test Method(s): KDB 680106 D01 Wireless Power Transfer v04 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 1.1307 & FCC Part 2.1091 & KDB680106 D01 requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. 2026-07-02 Date of Receipt Date of Test2026-07-02 to 2026-07-13 Prepared By (Cecilia Chen) Approved & Authorized Signer (Jules Guo) Report No.: 1812C60379812502 Page 4 of 10 FCC ID: 2BNPTW-103A Code:AB-RF-05-b Revision History Report VersionDescriptionIssued Date R00Original Issue.2026-08-24 Report No.: 1812C60379812502 Page 5 of 10 FCC ID: 2BNPTW-103A Code:AB-RF-05-b 1. General Information 1.1. Client Information Applicant:HWLT_FZE Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Manufacturer:Dongguan Agilian Technologies Co., Ltd Address: Room 202, No. 3, Dongyi Street, Xingfa South Road, Wusha community, Chang 'an Town, Dongguan City, Guangdong Province, China Factory :Dongguan Agilian Technologies Co., Ltd Address: Room 202, No. 3, Dongyi Street, Xingfa South Road, Wusha community, Chang 'an Town, Dongguan City, Guangdong Province, China 1.2. Description of Device (EUT) Product Name:Wireless Charger Model No.:W-103A Trade Mark:ERA Test Power Supply:5VDC from adapter input 120VAC/60Hz Test Sample No.:1-2-1(Normal Sample), 1-2-2(Engineering Sample) Adapter:N/A RF Specification Operation Frequency:119-205kHz Modulation Type:FSK Antenna Type:Inductive loop coil Antenna Remark: 1) All of the RF specification are provided by customer. 2) For a more detailed features description, please refer to the manufacturer’s specifications or the User’s Manual. Report No.: 1812C60379812502 Page 6 of 10 FCC ID: 2BNPTW-103A Code:AB-RF-05-b 1.3. Auxiliary Equipment Used During Test TitleManufacturerModel No.Serial No. Xiaomi 67W adapterXiaomiMDY-13-ESWA622091100375G Xiaomi 33W adapterXiaomiMDY-11-EXSA62212LA04358J ERA Wallet Dongguan Agilian Technologies Co., Ltd EWU-Y-1/ 1.4. Description of Test Modes Pretest ModesDescriptions TM1 Adapter+WPT Mode (5W-Load Battery Status: 1%) TM2 Adapter+WPT Mode (5W-Load Battery Status: 50%) TM3 Adapter+WPT Mode (5W-Load Battery Status: 99%) TM4 Standby Mode 1.5. Test Equipment List ItemEquipmentManufacturerModel No.Last Cal.Cal. Interval 1 Electric and Magnetic field Analyzer NARDAEHP-200A2025-10-291 Year 1.6. Measure…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 25 Code:AB-RF-05-b FCC Test Report Report No.:1812C60379812501 Applicant:HWLT_FZE Address: Dubai World Trade Center Sheikh Rashid Tower 04 FZF 312 SRT, Dubai, United Arab Emirates Product Name:Wireless Charger Report Date:2026-08-24 Shenzhen Anbotek Compliance Laboratory Limited #资质章# #检测章# #报告二维码# Report No.: 1812C60379812501 Page 2 of 25 FCC ID: 2BNPTW-103A Code:AB-RF-05-b Contents 1. General Information ............................................................................................................................5 1.1. Client Information ......................................................................................................................5 1.2. Description of Device (EUT) .....................................................................................................5 1.3. Auxiliary Equipment Used During Test .....................................................................................6 1.4. Description of Test Modes ........................................................................................................6 1.5. Description Of Test Setup .........................................................................................................7 1.6. Test Equipment List ..................................................................................................................8 1.7. Measurement Uncertainty .........................................................................................................9 1.8. Description of Test Facility ........................................................................................................9 1.9. Disclaimer .................................................................................................................................9 2. Summary of Test Results ..................................................................................................................10 3. Conducted Emission Test .................................................................................................................11 3.1. Test Standard and Limit ..........................................................................................................11 3.2. Test Setup...............................................................................................................................11 3.3. Test Procedure .......................................................................................................................11 3.4. Test Data ................................................................................................................................11 4. Radiation Spurious Emission Test ....................................................................................................14 4.1. Test Standard and Limit ..........................................................................................................14 4.2. Test Setup...............................................................................................................................14 4.3. Test Procedure .......................................................................................................................15 4.4. Test Data ................................................................................................................................15 5. 20dB Occupy Bandwidth Test ...........................................................................................................22 5.1. Test Standard and Limit ..........................................................................................................22 5.2. Test Setup...............................................................................................................................22 5.3. Test Procedure .......................................................................................................................22 5.4. Test Data ................................................................................................................................23 6. Antenna Requirement .......................................................................................................................24 6.1. Test Standard and Requirement .............................................................................................24 6.2. Antenna Connected Construction ...........................................................................................24 APPENDIX I -- TEST SETUP PHOTOGRAPH .....................................................................................25 APPENDIX II -- EXTERNAL PHOTOGRAPH .......................................................................................25 APPENDIX III -- INTERNAL PHOTOGRAPH .......................................................................................25 Report No.: 1812C60379812501 Page 3 of 25 FCC ID: 2BNPTW-103A Code:AB-RF-05-b TEST REPORT Applicant:HWLT_FZE Manufacturer:Dongguan Agilian Technologies Co., Ltd Product Name:Wireless Charger Model No.:W-103A Trade Mark:ERA Rating(s): Input: 5V⎓2A Wireless Charging Output: 5W Test Standard(s): FCC Part15 Subpart C Test Method(s): ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024 ANSI C63.30-2021 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. Date of Rec…

Text truncated - open the document above for the full version.

Test Report

Specification DocumentNumber A11 Nameofapart WirelessTransceiverCoilModule Productsize φ43.5*φ5*H1.4 AdhesionMethodHotairself-adhesion A 20.5±0.5 B 39±1 C 43.5±0.5 D 15±2 E 3±1 F 1.17±0.1 G 0.6±0.1 H 1.4±0.1 Unit:MM Wirestock 0.08×48shares WindingMethod Single-wirestrandedwindingtype Rem arks Thecoilrotates clockwise Numberofturns 10 Ts DiskSize Φ43.5*φ 5*0.6 L 6.5uH±10% CoilSize 39*φFormula20.5 TestFrequency 100KHZ TestMethod SeriesTest manufacturerDongguan Agilian Technologies Co., Ltd addressRoom 202, No. 3, Dongyi Street, Xingfa South Road, Wusha community, Chang 'an Town, Dongguan City, Guangdong Province, China

Contact Information

Applicant

Aleksei Deviatkin(Manager)
[email protected]Fax: /

Technical Contact

Linkwld LLCTimothy Zhu
[email protected]

7595 Technology Way Ste 100, Denver, CO 80237, US · Denver, Colorado, 80237 · United States

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.119 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.