FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Limpet Technology Co., Ltd./
  3. 2BNXK-P-LFPO1

2BNXK-P-LFPO1Wali Smart Pet Feeder With AI Camera

Shenzhen Limpet Technology Co., Ltd.
Wali Smart Pet Feeder With AI Camera - FCC ID 2BNXK-P-LFPO1 - Shenzhen Limpet Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 04, 2025
Application Purpose
Original Equipment
Equipment Note
Wali Smart Pet Feeder With AI Camera
Frequency Range
5180.00000000 - 5240.00000000
Company
Shenzhen Limpet Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Wali Smart Pet Feeder With AI Camera Table of contents Product Introduction Packing list Desiccant Instructions Installation Instructions Device connection instructions APP Main Interface Introduction Feeding plan instructions Screen display instructions Equipment Cleaning Instructions FCC Statement Warranty card 1 2 3 4 5 6 7 8 9 10 11 360 Panoramic Head: 360 degrees horizontal and 120 degrees vertical viewing 1 Full HD camera: 3 megapixels, supports 4x electronic zoom 2 LCD display: 2.8-inch LCD, high-definition display 3 Microphone: Single MIC | Support two-way voice 4 Speaker: 2W speaker 5 Infrared fill light: Visible at night 6 Feed button: Double-click to feed one portion of food. Each portion weight is about 10g, may be different due to the different density of cat food. 7 Reset button: Press and hold for 5 s to restore factory settings Upper lid lift button: Lock the upper lid of the food barrel. 10 Food storage barrel: 5.5L large food barrel, upper lid+ double silicone on food outlet for moisture-proof, can be easily disassembled and washed. 11 Food barrel lift button: Lock the food barrel. 12 Stainless steel food bowl: 304 stainless steel food bowl can be easily disassembled and washed. 13 Power socket: DC5V/2A, diameter 2.1mm DC interface. 14 Battery compartment: 4 AA batteries, only for offline feeding function. 15 Temperature and humidity sensor: Detect current temperature and humidity values. 16 Feeder base: Food anti-stuck design, responsible for feeding and powering the gimbal. 17 Product Introduction PRODUCT MANUAL 1 2 3 9 11 13 6 4 7 8 17 5 14 15 12 16 10 1 8 Food barrel cover: Sealed grain bucket, keeps cat food fresh. 9 Packing list PRODUCT MANUAL Main Unit Power Supply Desiccant Box User Manual 2 Desiccant Instructions PRODUCT MANUAL Food Contact Safe Materials: Made from materials safe for contact with food, ensuring effective moisture absorption while keeping the pet food fresh and safe. Triple Freshness preservation+ Food-grade Safety: The moisture-proof effect lasts for over one month. It is recommended to replace the desiccant once a month. First step of Freshness Retention: The lid around the barrel is fully sealable. Second step of Freshness Retention: A large desiccant inside the bucket. Third step of Freshness Retention: The outlet is sealable to keep the pet food fresh. Moisture Absorption and Freshness Retention: Ensures that every bite your pet eats is crisp and fresh. 3 Installation Instructions PRODUCT MANUAL STEP1 Open the package Open the package and take out the base. STEP2 Install the food barrel Slide the "food barrel" down the "base" column until you hear two "clicks". STEP5 Install the desiccant Tear open the sealed bag of desiccant, and buckle the round buckle into the concave position of the lid. You can hear a "click" to ensure it will not fall off. STEP6 Install the lid Align the buttons on both sides of the lid with the sides of the food barrel and press down from there until you hear "click", and there will be no gap between the food barrel and the lid. STEP3 Install the food bowl First lift the base, make sure there are two holes at the bottom, insert the two raised points on the edge of the food bowl into the holes, assemble and place on the ground. Pour the pet food into the food barrel (the pet food dimension needs to be smaller than 16mm per kibble) Add cat food STEP4 Plug in the power cord into an outlet to give it power. Plug in STEP7 Double-click the device button to add food to your pet. Double-click to dispense food STEP8 4 Scan the QR code to download the App or search for "Limpet" in the App Store to download it. STEP1 Open the App and register a new user STEP2 Enable required permissions STEP5 Finding equipment STEP6 Email Verification STEP3 Login successfully, add the device. STEP4 Configure the network STEP7 Connection successful STEP8 [email protected] Limpet.net Device connects to app PRODUCT MANUAL 5 Online Feeding 1 View Food Bowl 2 Recording Video 3 Take a photo 4 Two-way audio 5 Turn on the sound 6 Clarity adjustment 7 Pet calling sound 8 PTZ control 9 Settings 10 APP Main Interface Introduction PRODUCT MANUAL 1 2 3456789 10 6 Check and call your cat anytime, anywhere๏ผ› Let your pet no longer be lonely and bored๏ผ› Let your pet know you are always with it. APP basic functions: Food shortage reminder | Food surplus detection | Feeding plan | Real-time pet monitoring | Two-way voice APP subscription functions: AI tracking | AI editing | Cloud storage | Abnormal sound reminder | Safety notification You can find the feeding schedule in settings to adjust it STEP1 Click the "Add a Meal" button and enter the specific plan to adjust the plan according to your wishes. STEP2 Or click on the AI feeding plan and enter the pet information according to the guidance. STEP3 The AI will automatically generate a scientific feeding plan for your pet based on the input pet information. STEP4 Feeding plan instructions PRODUCT MANUAL 7 Screen display instructions PRODUCT MANUAL Time display 23 Network status Real-time temperature and humidity detection 4 Current Environmental Assessment Display of the number of food portions delivered on the day. 5 Display the number of planned food distributions for the day. 6 Display the number of times the pet has eaten on that day. 7 1 10M 1M Place against a wall in bright place: within 10 meters of the WI-FI router๏ผ› There is no obstruction within 1 meter in front to avoid collisions when cats are playing.ใ€‚ Placement Guidelines 8 There is a rotating box at the bottom of the food barrel, the food bowl can be disassembled and cleaned. The plastic food box and the stainless steel food bowl can be washed. It is recommended to clean them once a week. STEP2 Take out the food barrel and wash or wipe it directly. Do not wash the base and the barrel lid with water, but can wipe them with a damp cloth. STEP1 tips : Press the buttons on both sides of the food barrel at the same time and lift the food bโ€ฆ

Text truncated - open the document above for the full version.

Test Report

R&D,productionandsalesofprofessionalwirelessterminalantenna SPECIFICATION CustomerName๏ผšLINGCHONGTechnologyCo.,Ltd. ProductModel๏ผšWali CustomerP/N๏ผš XINHENGYANGP/N๏ผšCP.21.0000189 SPECIFFCATIONS:2.4G+5.8G๏ผŒFPC๏ผŒ31.2*26.3mm๏ผŒL=90mm Productiondate๏ผš2025.02.14 SampleVersion๏ผšR1.0 Manufacturer:ShenzhenXinhengyangTechnologyCo.,Ltd. ShenzhenAddress:No.7,LangshanSecondRoad,XiliSubistrict,Nanshan District,Shenzhen,FirstFloor,BuildingB,AerospaceMicro-motor Building Phone:0755-8360916Email:[email protected] Website:https://www.xhy-2008 XINHENGYANG FICTIONDQER&D Customer PURQCR&D R&D,productionandsalesofprofessionalwirelessterminalantenna Index Cover ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท1 Indexยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท2 Changehistoryยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท3 Thebasicparametersยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท4 TestEquipment&Conditionsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท5 TestReportยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท6โ€”9 ProductDrawingยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท10 RoHS/Billofmaterialsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท11 R&D,productionandsalesofprofessionalwirelessterminalantenna Changehistory NumberEffectivedateChangerecord R1.02025.02.14 Initialrelease R&D,productionandsalesofprofessionalwirelessterminalantenna Thebasicparameters A.ElectricalCharacteristics Frequency2400MHZ~2500MHZ 515 5150MHZ~5850MHZ VSWR<2 AvgEfficiency>50% Impedance50 ยฑ 15Ohm PolarizationLinear PeakGain2.4G:3.54dBi 5G:5.26dBi B.Material&MechanicalCharacteristics MaterialofRadiatorFPCblack CableTypeฮฆ1.13LOWLOSS๏ผŒ90mm ConnectorTypeGeneration Dimension31.20MM*26.30MM ยฑ 0.2MM C.Environmental OperationTemperature-20 ฬŠC~+60 ฬŠC StorageTemperature-30 ฬŠC~+70 ฬŠC R&D,productionandsalesofprofessionalwirelessterminalantenna Introduction: Microwavedarkroomandnoreflectionchamber,absorbingshortwavedarkroom darkroom.Microwavedarkroombyelectromagneticshieldingroom,filtering andisolation,groundingdevice,theventilationduct,indoordistributionsystem, monitoringsystem,ceilingwavematerialpart.Itisbasedonthewaveabsorbing materialastheliningoftheshieldroom,itcanabsorbthemostofthe electromagneticenergyintothesixwallisabettersimulationofthefreespace conditions. Themainworkingprincipleofmicrowaveanechoicchamberisaccordingtothe electromagneticwaveinthemediumfromthelowmagneticguidemagnetic directionofpropagationrules,absorbingmaterialstoguidetheelectromagnetic waveusinghighpermeability,throughresonance,asubstantialabsorptionof electromagneticwaveradiationenergy,bycouplingtheelectromagneticenergy intoheatenergy. mainperformance๏ผš Frequencyrange:400MHz~6GHzceilingreflectedwavelossmaterials:400MHz~ 6GHzisequaltoormorethan15dB(microwaveabsorbingmaterialbycompositewave absorbingmaterials,namelytaperedcontainingcarbonspongesuctionwavematerial pasteinferrite) R&D,productionandsalesofprofessionalwirelessterminalantenna TestReport ThosespecificationswerespeciallydefinedforWalimodel. 1.Machinepicturesandantennaassembly R&D,productionandsalesofprofessionalwirelessterminalantenna R&D,productionandsalesofprofessionalwirelessterminalantenna VSWR 2. MeasuringMethod 1.A50ฮฉcoaxialcableisconnectedtotheantenna.Thenthiscableisconnected toanetworkanalyzertomeasuretheVSWR 2.Keepingthisjigawayfrommetalatleast20cm 3.MeasurementfrequencypointsandVSWRvalue R&D,productionandsalesofprofessionalwirelessterminalantenna 4.GaintableofAntenna: 2400-2500MHz R&D,productionandsalesofprofessionalwirelessterminalantenna 5150-5850MHz R&D,productionandsalesofprofessionalwirelessterminalantenna 5.OTA๏ผš R&D,productionandsalesofprofessionalwirelessterminalantenna ProductDrawing R&D,productionandsalesofprofessionalwirelessterminalantenna ROHS AntennaCP.21.0000189meetsROHSrequirementsSeeelectronic filefordetails. Productpackaginginstructions A.packingshouldmeetthemoisture-proof,vibration,pressureand mildewproof,etc. B.thesmallestpackingunitlogomusthavethemanufacturer trademarks,productmodel,name,codeandquantity. C.intheattachedpackinglist,certificateofapproval,andthefactory inspectionreport. ***************************END****************************

Test Setup Photos

FCCID:2BNXK-P-LFPO1 TestSetupPhotosoftheEUT FCCID:2BNXK-P-LFPO1

Test Report

1 FCCAppendixRFTestDatafor5.8GWIFI FCCID:2BNXK-P-LFPO1 Company::ShenzhenLimpetTechnologyCo.,Ltd. EUT:WaliSmartPetFeederWithAICamera ModelNumber:P-LFP01 ReportNo.:CTA25070500603 ReviewedBy:EricWang 2 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTa5745Ant116.346>=0.5Pass NVNTa5785Ant116.348>=0.5Pass NVNTa5825Ant116.346>=0.5Pass NVNTn205745Ant117.374>=0.5Pass NVNTn205785Ant117.3>=0.5Pass NVNTn205825Ant117.281>=0.5Pass 3 TestGraphs -6dBBandwidthNVNTa5745MHzAnt1 -6dBBandwidthNVNTa5785MHzAnt1 4 -6dBBandwidthNVNTa5825MHzAnt1 -6dBBandwidthNVNTn205745MHzAnt1 5 -6dBBandwidthNVNTn205785MHzAnt1 -6dBBandwidthNVNTn205825MHzAnt1 6 MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTa5745Ant111.260.1911.4530Pass NVNTa5785Ant110.440.1910.6330Pass NVNTa5825Ant110.590.1910.7830Pass NVNTn205745Ant111.380.2311.6130Pass NVNTn205785Ant110.750.2310.9830Pass NVNTn205825Ant110.830.2311.0630Pass 7 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/500KHz) DutyFactor (dB) TotalPSD (dBm/500KHz) Limit (dBm/500KHz) Verdict NVNTa5745Ant1-2.330.19-2.1430Pass NVNTa5785Ant1-3.250.19-3.0630Pass NVNTa5825Ant1-3.160.19-2.9730Pass NVNTn205745Ant1-2.30.23-2.0730Pass NVNTn205785Ant1-3.230.23-330Pass NVNTn205825Ant1-3.110.23-2.8830Pass 8 TestGraphs PSDNVNTa5745MHzAnt1 PSDNVNTa5785MHzAnt1 9 PSDNVNTa5825MHzAnt1 PSDNVNTn205745MHzAnt1 10 PSDNVNTn205785MHzAnt1 PSDNVNTn205825MHzAnt1 11 RestrictBand ConditionModeFrequency (MHz) AntennaSpurFreq (MHz) Power (dBm) Gain (dBi) Duty Factor (dB) EIRP Power (dBm) DetectorLimit (dBm) Verdict NVNTa5745Ant15650-47.535.26--42.27Peak-27Pass NVNTa5745Ant15650-55.895.260.19-50.44Average-27Pass NVNTa5745Ant15700-45.195.26--39.93Peak10Pass NVNTa5745Ant15700-53.975.260.19-48.52Average10Pass NVNTa5745Ant15720-31.395.26--26.13Peak15.6Pass NVNTa5745Ant15720-46.535.260.19-41.08Average15.6Pass NVNTa5745Ant15725-26.025.26--20.76Peak27Pass NVNTa5745Ant15725-41.915.260.19-36.46Average27Pass NVNTa5825Ant15850-34.525.26--29.26Peak27Pass NVNTa5825Ant15850-46.935.260.19-41.48Average27Pass NVNTa5825Ant15855-39.545.26--34.28Peak15.6Pass NVNTa5825Ant15855-51.785.260.19-46.33Average15.6Pass NVNTa5825Ant15875-47.095.26--41.83Peak10Pass NVNTa5825Ant15875-54.715.260.19-49.26Average10Pass NVNTa5825Ant15925-47.385.26--42.12Peak-27Pass NVNTa5825Ant15925-55.355.260.19-49.90Average-27Pass NVNTn205745Ant15650-48.465.26--43.20Peak-27Pass NVNTn205745Ant15650-55.95.260.23-50.41Average-27Pass NVNTn205745Ant15700-46.595.26--41.33Peak10Pass NVNTn205745Ant15700-54.045.260.23-48.55Average10Pass NVNTn205745Ant15720-29.295.26--24.03Peak15.6Pass NVNTn205745Ant15720-46.565.260.23-41.07Average15.6Pass NVNTn205745Ant15725-20.885.26--15.62Peak27Pass NVNTn205745Ant15725-40.345.260.23-34.85Average27Pass NVNTn205825Ant15850-33.255.26--27.99Peak27Pass NVNTn205825Ant15850-46.095.260.23-40.60Average27Pass NVNTn205825Ant15855-35.995.26--30.73Peak15.6Pass NVNTn205825Ant15855-51.715.260.23-46.22Average15.6Pass NVNTn205825Ant15875-46.135.26--40.87Peak10Pass NVNTn205825Ant15875-54.455.260.23-48.96Average10Pass NVNTn205825Ant15925-45.385.26--40.12Peak-27Pass NVNTn205825Ant15925-54.895.260.23-49.40Average-27Pass 12 TestGraphs RestrictBandNVNTa5745MHzAnt1Peak RestrictBandNVNTa5745MHzAnt1Average 13 RestrictBandNVNTa5825MHzAnt1Peak RestrictBandNVNTa5825MHzAnt1Average 14 RestrictBandNVNTn205745MHzAnt1Peak RestrictBandNVNTn205745MHzAnt1Average 15 RestrictBandNVNTn205825MHzAnt1Peak RestrictBandNVNTn205825MHzAnt1Average 16 FrequencyStability ConditionModeFrequency (MHz) AntennaMeasuredFrequency (MHz) FrequencyError (Hz) Deviation (ppm) Limit (ppm) Verdict NVNTa5745Ant157450025Pass NVNTa5785Ant157850025Pass NVNTa5825Ant158250025Pass NVNTn205745Ant15744.98-20000-3.4825Pass NVNTn205785Ant15784.98-20000-3.4625Pass NVNTn205825Ant158250025Pass 17 TestGraphs Freq.StabilityNVNTa5745MHzAnt1 Freq.StabilityNVNTa5785MHzAnt1 18 Freq.StabilityNVNTa5825MHzAnt1 Freq.StabilityNVNTn205745MHzAnt1 19 Freq.StabilityNVNTn205785MHzAnt1 Freq.StabilityNVNTn205825MHzAnt1 20 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTa5745Ant195.680.190.72 NVNTa5785Ant195.750.190.72 NVNTa5825Ant195.680.190.72 NVNTn205745Ant194.940.230.85 NVNTn205785Ant194.940.230.85 NVNTn205825Ant194.940.230.85 21 TestGraphs DutyCycleNVNTa5745MHzAnt1 DutyCycleNVNTa5785MHzAnt1 22 DutyCycleNVNTa5825MHzAnt1 DutyCycleNVNTn205745MHzAnt1 23 DutyCycleNVNTn205785MHzAnt1 DutyCycleNVNTn205825MHzAnt1

Test Report

1 FCCAppendixRFTestDatafor5.5GWIFI FCCID:2BNXK-P-LFPO1 Company::ShenzhenLimpetTechnologyCo.,Ltd. EUT:WaliSmartPetFeederWithAICamera ModelNumber:P-LFP01 ReportNo.:CTA25070500603 ReviewedBy:EricWang 2 -26dBBandwidth ConditionModeFrequency(MHz)Antenna-26dBBandwidth(MHz)Limit-26dBBandwidth(MHz)Verdict NVNTa5500Ant126.729---Pass NVNTa5580Ant126.083---Pass NVNTa5700Ant127.445---Pass NVNTn205500Ant128.89---Pass NVNTn205580Ant128.274---Pass NVNTn205700Ant128.129---Pass 3 TestGraphs -26dBBandwidthNVNTa5500MHzAnt1 -26dBBandwidthNVNTa5580MHzAnt1 4 -26dBBandwidthNVNTa5700MHzAnt1 -26dBBandwidthNVNTn205500MHzAnt1 5 -26dBBandwidthNVNTn205580MHzAnt1 -26dBBandwidthNVNTn205700MHzAnt1 6 MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTa5500Ant113.690.1913.8824Pass NVNTa5580Ant113.910.1914.124Pass NVNTa5700Ant113.950.1914.1424Pass NVNTn205500Ant113.930.2314.1624Pass NVNTn205580Ant114.110.2314.3424Pass NVNTn205700Ant113.150.2213.3724Pass 7 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/MHz) DutyFactor (dB) TotalPSD (dBm/MHz) Limit (dBm/MHz) Verdict NVNTa5500Ant13.320.193.5111Pass NVNTa5580Ant13.30.193.4911Pass NVNTa5700Ant13.460.193.6511Pass NVNTn205500Ant13.140.233.3711Pass NVNTn205580Ant13.260.233.4911Pass NVNTn205700Ant12.330.222.5511Pass 8 TestGraphs PSDNVNTa5500MHzAnt1 PSDNVNTa5580MHzAnt1 9 PSDNVNTa5700MHzAnt1 PSDNVNTn205500MHzAnt1 10 PSDNVNTn205580MHzAnt1 PSDNVNTn205700MHzAnt1 11 RestrictBand ConditionModeFrequency (MHz) AntennaSpur Freq (MHz) Power (dBm) Gain (dBi) Duty Factor (dB) E (dBuV/m) DetectorLimit (dBuV/m) Verdict NVNTa5500Ant15460-44.295.26-56.20Peak68.2Pass NVNTa5500Ant15460-52.815.260.1947.87Average54Pass NVNTa5500Ant15470-35.615.26-64.88Peak68.2Pass NVNTa5500Ant15470-47.665.260.1953.02Average54Pass NVNTa5700Ant15725-34.925.26-65.57Peak68.2Pass NVNTa5700Ant15725-48.395.260.1952.29Average54Pass NVNTa5700Ant15725.2-31.295.26-69.20Peak68.2Pass NVNTa5700Ant15725.2-47.345.260.1953.34Average54Pass NVNTa5700Ant15735-42.155.26-58.34Peak68.2Pass NVNTa5700Ant15735-53.725.260.1946.96Average54Pass NVNTn205500Ant15460-43.665.26-56.83Peak68.2Pass NVNTn205500Ant15460-51.945.260.2348.78Average54Pass NVNTn205500Ant15469.8-31.695.26-68.80Peak68.2Pass NVNTn205500Ant15470-45.825.260.2354.90Average54Pass NVNTn205500Ant15470-33.495.26-67.00Peak68.2Pass NVNTn205500Ant15470-45.825.260.2354.90Average54Pass NVNTn205700Ant15725-34.025.26-66.47Peak68.2Pass NVNTn205700Ant15725-48.075.260.2252.64Average54Pass NVNTn205700Ant15735-45.735.26-54.76Peak68.2Pass NVNTn205700Ant15735-54.115.260.2246.60Average54Pass 12 TestGraphs RestrictBandNVNTa5500MHzAnt1Peak RestrictBandNVNTa5500MHzAnt1Average 13 RestrictBandNVNTa5700MHzAnt1Peak RestrictBandNVNTa5700MHzAnt1Average 14 RestrictBandNVNTn205500MHzAnt1Peak RestrictBandNVNTn205500MHzAnt1Average 15 RestrictBandNVNTn205700MHzAnt1Peak RestrictBandNVNTn205700MHzAnt1Average 16 FrequencyStability ConditionModeFrequency (MHz) AntennaMeasuredFrequency (MHz) FrequencyError (Hz) Deviation (ppm) Limit (ppm) Verdict NVNTa5500Ant155000025Pass NVNTa5580Ant155800025Pass NVNTa5700Ant15699.98-20000-3.5125Pass NVNTn205500Ant155000025Pass NVNTn205580Ant15580.02200003.5825Pass NVNTn205700Ant157000025Pass 17 TestGraphs Freq.StabilityNVNTa5500MHzAnt1 Freq.StabilityNVNTa5580MHzAnt1 18 Freq.StabilityNVNTa5700MHzAnt1 Freq.StabilityNVNTn205500MHzAnt1 19 Freq.StabilityNVNTn205580MHzAnt1 Freq.StabilityNVNTn205700MHzAnt1 20 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTa5500Ant195.750.190.72 NVNTa5580Ant195.750.190.72 NVNTa5700Ant195.680.190.72 NVNTn205500Ant194.940.230.85 NVNTn205580Ant194.940.230.85 NVNTn205700Ant195.020.220.85 21 TestGraphs DutyCycleNVNTa5500MHzAnt1 DutyCycleNVNTa5580MHzAnt1 22 DutyCycleNVNTa5700MHzAnt1 DutyCycleNVNTn205500MHzAnt1 23 DutyCycleNVNTn205580MHzAnt1 DutyCycleNVNTn205700MHzAnt1

Test Report

1 FCCAppendixRFTestDatafor5.3GWIFI FCCID:2BNXK-P-LFPO1 Company::ShenzhenLimpetTechnologyCo.,Ltd. EUT:WaliSmartPetFeederWithAICamera ModelNumber:P-LFP01 ReportNo.:CTA25070500603 ReviewedBy:EricWang 2 -26dBBandwidth ConditionModeFrequency(MHz)Antenna-26dBBandwidth(MHz)Limit-26dBBandwidth(MHz)Verdict NVNTa5260Ant128.972---Pass NVNTa5300Ant128.565---Pass NVNTa5320Ant126.298---Pass NVNTn205260Ant128.818---Pass NVNTn205300Ant128.719---Pass NVNTn205320Ant126.626---Pass 3 TestGraphs -26dBBandwidthNVNTa5260MHzAnt1 -26dBBandwidthNVNTa5300MHzAnt1 4 -26dBBandwidthNVNTa5320MHzAnt1 -26dBBandwidthNVNTn205260MHzAnt1 5 -26dBBandwidthNVNTn205300MHzAnt1 -26dBBandwidthNVNTn205320MHzAnt1 6 MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTa5260Ant112.650.1912.8424Pass NVNTa5300Ant112.840.1913.0324Pass NVNTa5320Ant113.230.1913.4224Pass NVNTn205260Ant112.840.2313.0724Pass NVNTn205300Ant113.040.2313.2724Pass NVNTn205320Ant1140.2314.2324Pass 7 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/MHz) DutyFactor (dB) TotalPSD (dBm/MHz) Limit (dBm/MHz) Verdict NVNTa5260Ant11.950.192.1411Pass NVNTa5300Ant12.970.193.1611Pass NVNTa5320Ant12.970.193.1611Pass NVNTn205260Ant12.370.232.611Pass NVNTn205300Ant12.70.232.9311Pass NVNTn205320Ant13.270.233.511Pass 8 TestGraphs PSDNVNTa5260MHzAnt1 PSDNVNTa5300MHzAnt1 9 PSDNVNTa5320MHzAnt1 PSDNVNTn205260MHzAnt1 10 PSDNVNTn205300MHzAnt1 PSDNVNTn205320MHzAnt1 11 RestrictBand ConditionModeFrequency (MHz) AntennaSpurFreq (MHz) Power (dBm) Gain (dBi) Duty Factor (dB) E (dBuV/m) DetectorLimit (dBuV/m) Verdict NVNTa5260Ant14500-48.685.26-51.81Peak68.2Pass NVNTa5260Ant14500-56.75.260.1943.98Average54Pass NVNTa5260Ant15133.36-44.885.26-55.61Peak68.2Pass NVNTa5260Ant14773-53.95.260.1946.78Average54Pass NVNTa5260Ant15150-45.755.26-54.74Peak68.2Pass NVNTa5260Ant15150-54.965.260.1945.72Average54Pass NVNTa5320Ant15350-35.795.26-64.70Peak68.2Pass NVNTa5320Ant15350-48.295.260.1952.39Average54Pass NVNTa5320Ant15350.2-35.075.26-65.42Peak68.2Pass NVNTa5320Ant15350.8-47.975.260.1952.71Average54Pass NVNTa5320Ant15460-48.945.26-51.55Peak68.2Pass NVNTa5320Ant15460-56.065.260.1944.62Average54Pass NVNTn205260Ant14500-48.865.26-51.63Peak68.2Pass NVNTn205260Ant14500-56.585.260.2344.14Average54Pass NVNTn205260Ant15143.5-44.815.26-55.68Peak68.2Pass NVNTn205260Ant14787.82-53.455.260.2347.27Average54Pass NVNTn205260Ant15150-45.115.26-55.38Peak68.2Pass NVNTn205260Ant15150-54.35.260.2346.42Average54Pass NVNTn205320Ant15350-39.175.26-61.32Peak68.2Pass NVNTn205320Ant15350-51.995.260.2348.73Average54Pass NVNTn205320Ant15351.2-37.915.26-62.58Peak68.2Pass NVNTn205320Ant15350.4-51.625.260.2349.10Average54Pass NVNTn205320Ant15460-47.695.26-52.80Peak68.2Pass NVNTn205320Ant15460-56.195.260.2344.53Average54Pass 12 TestGraphs RestrictBandNVNTa5260MHzAnt1Peak RestrictBandNVNTa5260MHzAnt1Average 13 RestrictBandNVNTa5320MHzAnt1Peak RestrictBandNVNTa5320MHzAnt1Average 14 RestrictBandNVNTn205260MHzAnt1Peak RestrictBandNVNTn205260MHzAnt1Average 15 RestrictBandNVNTn205320MHzAnt1Peak RestrictBandNVNTn205320MHzAnt1Average 16 FrequencyStability ConditionModeFrequency (MHz) AntennaMeasuredFrequency (MHz) FrequencyError (Hz) Deviation (ppm) Limit (ppm) Verdict NVNTa5260Ant15260.02200003.825Pass NVNTa5300Ant15299.98-20000-3.7725Pass NVNTa5320Ant153200025Pass NVNTn205260Ant15259.98-20000-3.825Pass NVNTn205300Ant15299.98-20000-3.7725Pass NVNTn205320Ant153200025Pass 17 TestGraphs Freq.StabilityNVNTa5260MHzAnt1 Freq.StabilityNVNTa5300MHzAnt1 18 Freq.StabilityNVNTa5320MHzAnt1 Freq.StabilityNVNTn205260MHzAnt1 19 Freq.StabilityNVNTn205300MHzAnt1 Freq.StabilityNVNTn205320MHzAnt1 20 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTa5260Ant195.750.190.72 NVNTa5300Ant195.750.190.72 NVNTa5320Ant195.680.190.72 NVNTn205260Ant194.940.230.85 NVNTn205300Ant194.940.230.85 NVNTn205320Ant194.940.230.85 21 TestGraphs DutyCycleNVNTa5260MHzAnt1 DutyCycleNVNTa5300MHzAnt1 22 DutyCycleNVNTa5320MHzAnt1 DutyCycleNVNTn205260MHzAnt1 23 DutyCycleNVNTn205300MHzAnt1 DutyCycleNVNTn205320MHzAnt1

Test Report

1 FCCAppendixRFTestDatafor5.2GWIFI FCCID:2BNXK-P-LFPO1 Company::ShenzhenLimpetTechnologyCo.,Ltd. EUT:WaliSmartPetFeederWithAICamera ModelNumber:P-LFP01 ReportNo.:CTA25070500603 ReviewedBy:EricWang 2 -26dBBandwidth ConditionModeFrequency(MHz)Antenna-26dBBandwidth(MHz)Limit-26dBBandwidth(MHz)Verdict NVNTa5180Ant128.081---Pass NVNTa5200Ant128.351---Pass NVNTa5240Ant128.668---Pass NVNTn205180Ant128.044---Pass NVNTn205200Ant127.719---Pass NVNTn205240Ant128.71---Pass 3 TestGraphs -26dBBandwidthNVNTa5180MHzAnt1 -26dBBandwidthNVNTa5200MHzAnt1 4 -26dBBandwidthNVNTa5240MHzAnt1 -26dBBandwidthNVNTn205180MHzAnt1 5 -26dBBandwidthNVNTn205200MHzAnt1 -26dBBandwidthNVNTn205240MHzAnt1 6 MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTa5180Ant113.40.1913.5924Pass NVNTa5200Ant113.030.1913.2224Pass NVNTa5240Ant112.290.1912.4824Pass NVNTn205180Ant113.610.2313.8424Pass NVNTn205200Ant113.310.2313.5424Pass NVNTn205240Ant112.390.2312.6224Pass 7 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/MHz) DutyFactor (dB) TotalPSD (dBm/MHz)) Limit (dBm/MHz) Verdict NVNTa5180Ant12.660.192.8511Pass NVNTa5200Ant12.450.192.6411Pass NVNTa5240Ant11.510.191.711Pass NVNTn205180Ant12.740.232.9711Pass NVNTn205200Ant12.630.232.8611Pass NVNTn205240Ant11.620.231.8511Pass 8 TestGraphs PSDNVNTa5180MHzAnt1 PSDNVNTa5200MHzAnt1 9 PSDNVNTa5240MHzAnt1 PSDNVNTn205180MHzAnt1 10 PSDNVNTn205200MHzAnt1 PSDNVNTn205240MHzAnt1 11 RestrictBand ConditionModeFrequency (MHz) AntennaSpurFreq (MHz) Power (dBm) Gain (dBi) Duty Factor (dB) E (dBuV/m) DetectorLimit (dBuV/m) Verdict NVNTa5180Ant14500-48.225.26-52.27Peak68.2Pass NVNTa5180Ant14500-55.355.260.1945.33Average54Pass NVNTa5180Ant15149.6-34.115.26-66.38Peak68.2Pass NVNTa5180Ant15149.6-49.115.260.1951.57Average54Pass NVNTa5180Ant15150-37.045.26-63.45Peak68.2Pass NVNTa5180Ant15150-48.345.260.1952.34Average54Pass NVNTa5240Ant15350-47.095.26-53.40Peak68.2Pass NVNTa5240Ant15350-54.925.260.1945.76Average54Pass NVNTa5240Ant15424.96-45.055.26-55.44Peak68.2Pass NVNTa5240Ant15351.52-54.225.260.1946.46Average54Pass NVNTa5240Ant15460-47.715.26-52.78Peak68.2Pass NVNTa5240Ant15460-55.375.260.1945.31Average54Pass NVNTn205180Ant14500-47.395.26-53.10Peak68.2Pass NVNTn205180Ant14500-55.925.260.2344.80Average54Pass NVNTn205180Ant15145.4-34.875.26-65.62Peak68.2Pass NVNTn205180Ant15148.9-46.65.260.2354.12Average54Pass NVNTn205180Ant15150-32.325.26-68.17Peak68.2Pass NVNTn205180Ant15150-46.895.260.2353.83Average54Pass NVNTn205240Ant15350-46.575.26-53.92Peak68.2Pass NVNTn205240Ant15350-55.175.260.2345.55Average54Pass NVNTn205240Ant15441.04-44.485.26-56.01Peak68.2Pass NVNTn205240Ant15352-54.375.260.2346.35Average54Pass NVNTn205240Ant15460-47.725.26-52.77Peak68.2Pass NVNTn205240Ant15460-55.55.260.2345.22Average54Pass 12 TestGraphs RestrictBandNVNTa5180MHzAnt1Peak RestrictBandNVNTa5180MHzAnt1Average 13 RestrictBandNVNTa5240MHzAnt1Peak RestrictBandNVNTa5240MHzAnt1Average 14 RestrictBandNVNTn205180MHzAnt1Peak RestrictBandNVNTn205180MHzAnt1Average 15 RestrictBandNVNTn205240MHzAnt1Peak RestrictBandNVNTn205240MHzAnt1Average 16 FrequencyStability ConditionModeFrequency (MHz) AntennaMeasuredFrequency (MHz) FrequencyError (Hz) Deviation (ppm) Limit (ppm) Verdict NVNTa5180Ant151800025Pass NVNTa5200Ant152000025Pass NVNTa5240Ant152400025Pass NVNTn205180Ant151800025Pass NVNTn205200Ant15199.98-20000-3.8525Pass NVNTn205240Ant152400025Pass 17 TestGraphs Freq.StabilityNVNTa5180MHzAnt1 Freq.StabilityNVNTa5200MHzAnt1 18 Freq.StabilityNVNTa5240MHzAnt1 Freq.StabilityNVNTn205180MHzAnt1 19 Freq.StabilityNVNTn205200MHzAnt1 Freq.StabilityNVNTn205240MHzAnt1 20 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTa5180Ant195.680.190.72 NVNTa5200Ant195.750.190.72 NVNTa5240Ant195.750.190.72 NVNTn205180Ant194.940.230.85 NVNTn205200Ant194.940.230.85 NVNTn205240Ant194.940.230.85 21 TestGraphs DutyCycleNVNTa5180MHzAnt1 DutyCycleNVNTa5200MHzAnt1 22 DutyCycleNVNTa5240MHzAnt1 DutyCycleNVNTn205180MHzAnt1 23 DutyCycleNVNTn205200MHzAnt1 DutyCycleNVNTn205240MHzAnt1

Test Report

ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,Fuhai Street,Baoโ€™anDistrict,Shenzhen,China ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,Baoโ€™anDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn TESTREPORT FCCPART15.407 ReportReferenceNo........................:CTA25070500604 FCCID.................................................:2BNXK-P-LFPO1 Compiledby (position+printedname+signature) .. : FileadministratorsZoeyCao Supervisedby (position+printedname+signature)..: ProjectEngineerAceChai Approvedby (position+printedname+signature) .. : RFManagerEricWang Dateofissue.........................................:Aug.26,2025 RepresentativeLaboratoryName . :ShenzhenCTATestingTechnologyCo.,Ltd. Address ................................................ : Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity, FuhaiStreet,Baoโ€˜anDistrict,Shenzhen,China Applicantโ€™sname...............................: ShenzhenLimpetTechnologyCo.,Ltd. Address.................................................: Room401,Building11,JiangganshanNo.1Garden,Buxin Community,Xinโ€™anSub-district,Baoโ€™an,District,ShenzhenCity, GuangdongProvince,China Testspecification .............................. : Standard................................................: FCCPart15.407 KDB905462D02UNIIDFSComplianceProceduresNewRulesv02 KDB905462D03UNIIClientsWithoutRadarDetectionNewRules v01r02 ShenzhenCTATestingTechnologyCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhen CTATestingTechnologyCo.,Ltd.isacknowledgedascopyrightownerandsourceofthematerial.Shenzhen CTATestingTechnologyCo.,Ltd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresulting fromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. Testitemdescription........................:WaliSmartPetFeederWithAICamera TradeMark............................................: Limpet Manufacturer ......................................... : ShenzhenLimpetTechnologyCo.,Ltd. Model/Typereference.........................: P-LFP01 ListedModels......................................:N/A ModulationType .................................. :OFDM Rating.....................................................: Input:5.0V2.0A Result.....................................................:PASS ReportNo.:CTA25070500604Page 2 of 19 ShenzhenCTATestingTechnologyCo.,Ltd. Room106,Building1,YibaolaiIndustrialPark,QiaotouCommunity,FuhaiStreet,Baoโ€™anDistrict,Shenzhen,China Tel:+86-75523225875E-mail:[email protected]:http://www.cta-test.cn TESTREPORT EquipmentunderTest: WaliSmartPetFeederWithAICamera Model/Type: P-LFP01 Applicant :ShenzhenLimpetTechnologyCo.,Ltd. Address: Room401,Building11,JiangganshanNo.1Garden,Buxin Community,Xinโ€™anSub-district,Baoโ€™an,District,ShenzhenCity, GuangdongProvince,China Manufacturer :ShenzhenLimpetTechnoโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jessi Ouyang
[email protected]Fax: 18688714359

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz24.20 mW
215E5.26 GHz - 5.32 GHz26.50 mW
315E5.50 GHz - 5.70 GHz27.20 mW
415E5.75 GHz - 5.83 GHz14.50 mW
Confidentiality
Long Term
Grant Notes
Output power listed is average conducted. This device supports 802.11a and 802.11n with a 20 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.