Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Address: Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Product Name: Digital Camera FCCID: 2BNYY-VE418 Model(s): VE418 2.911(d)(5)(i) EquipmentType We, [SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: zhaoyang long Date: Nov. 28, 2025 Title: Manager Company name: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Signature: NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Address: Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Product Name: Digital Camera FCCID: 2BNYY-VE418 Model(s): VE418 2.911(d)(5)(ii) Applicant filing We, [SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to §1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: zhaoyang long Date: Nov. 28, 2025 Title: Manager Company name: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Signature: NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Agent Authorization Company: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Address: Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Product Name: Digital Camera Model Number(s): VE418 Product Description: Digital Camera We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Nov. 28, 2025 Name: zhaoyang long Title: Manager Company: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD.
SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Nov. 28, 2025 Subject; Request for Confidentiality FCC ID: 2BNYY-VE418 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: zhaoyang long Title: Manager
FCC ID LABEL: Ca. 5mm x 20mm Label Location FCC ID: 2BNYY-VE418
FCC RF Exposure EUT Description: Digital Camera Model No.: VE418 FCC ID: 2BNYY‐VE418 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√ f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation Frequency (MHz) Output power (dBm) Tune Up Power (dBm) Max Tune Up power (dBm/mW) Min test separation distance mm Result Limit (mW/cm 2 ) SAR Test Exclusion 2462 3.8 3±1 4/2.51 5 0.788 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2510145634‐E, antenna gain= 1.73dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.788 which is<= 3, RF Exposure testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f (GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm
Address: 402TEL: 0755-23203435fax: 0755-23203435, Block C, Juxin Science and Technology Industrial Park, Nanchang community, xixiang, Baoan District, Shenzhen Antenna specification Antenna Sample Confirmation From Name of supplier Customer name Sonida Sample name VE418 model Sample size WIFI antenna: line length:40mm 3rd generation line Silkscreen: VE 418-WIFI-AH Inspection item Performance test Visual inspection Structure In the news Test results Notes Quality Audit Project Audit Business confirm ation The following is to be completed by the client Manufacturer:ShenZhen Aihui Technology Co.,Ltd Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen Customer feedback Customer signature/seal date: AntennaTest Report TestUnit:ShenzhenAihuiTechnologyCo., Ltd. Materials FPC Antenna form PIFA Polarizationmode Linear Application 2400Mhz-2500Mhz Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen scenario Workingband 2400Mhz-2500Mhz VSWR≤2 Power Max :2WImpedance50 Ω dBi≥1dBi Test EquipmentHPE5071C、ShieldingRoom 、3D automaticturntable AntennaDescription:: 1. Groundingprocessingand picturedescription:no 2. Need to changethe motherboardto match:no Test voltage:3.6V, checkthe antennacontactis good beforetesting. The RF cable of the integratedtesteris kept in a naturalstate and can not be curled. Specification:testthe specifiedpowerlevel,all indicatorsmustconformto the specifications. Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen 1.ProjectImage 2.TestFixture 3. Antennamatchingcircuit 4.S11test 5. Antennapassiveefficiencyandgain 6.Activeantennatestdata 7.Antennapassivetestdata 8. AntennaSWR 9.Antennamassproductionindex 10.Structuraldrawings 1.ProjectImage The final verificationantennaperformanceprototypein our companyfor at least one year, easy to analyzeand solve the problemof antennamass production,to ensurethe quality of antennashipment 2.TestFixture Objective:to test the passiveparametersof antennaas accuratelyas possible.Making Method:the handsetis made of a 50 ohm coaxialcable,one end of which is connectedto the test point of the back end of the matchingcircuit of the handsetmotherboard(front end of the RF test hole) , and the other end is connectedto the SMA joint. The diagramis as follows: Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen 3、 Antennamatchingcircuit Modify E01E02E03 NoNoNo Note:Thematchisunmodified. 4.S11test 4.0 4.0s11test methoddescriptionof test equipment:NetworkAnalyzer(E5071C)test method:a 50 ohm CABLEis used to exportfrom the instrumenttest port. The SMA connectorfor connectingthe handsetis calibratedusing a calibrationpiece,recordthe echo loss and standingwave ratio correspondingto the relevantfrequencypoints.The test schematicis as follows: Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen 5.TestEquipment Testsystem:shieldeddarkroom Thetemperaturewas22° C±3 ° Candthe humiditywas50%±15% Test equipment:when testingpassivedata, use the NetworkanalyzerAGILENTE5071C to test activedata, use the omnibusCMW500 Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen 6.Activeantennatestdata 7.Antennapassivetestdata Address:402TEL:0755-23203435fax:0755-23203435,Block C, Juxin Scienceand TechnologyIndustrialPark, Nanchangcommunity,xixiang,BaoanDistrict,Shenzhen 8.AntennaSWR 9.Antennamassproductionindex Whentheantennaismass-produced,the standingwaveratioistakenasthe mass-producedteststandard. Basedonthedifferencesoftheprojectitself,the followingcriteriaaregiven: Address: 402TEL: 0755-23203435fax: 0755-23203435, Block C, Juxin Science and Technology Industrial Park, Nanchang community, xixiang, Baoan District, Shenzhen Frequency Standard for volume production 2400 MHZ -2500MHZ VSWR (Mass Production performance) & LT; VSWR(recognition performance) 0.5 10.Structural drawings VE418 VE418-WIFI-AH
Page 1 of 72 Report No.: HK2510145634-E FCC Test Report Test Report On Behalf of SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. For Digital Camera Model No.: VE418 FCC ID: 2BNYY-VE418 Prepared For: SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Oct. 14, 2025 ~ Nov. 25, 2025 Date of Report: Nov. 25, 2025 Report Number: HK2510145634-E Page 2 of 72 Report No.: HK2510145634-E Test Result Certification Applicant’s Name .................. : SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Address .................................. : Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Manufacturer's Name ........... : SONGDIAN TECHNOLOGY(GUANGDONG)CO., LTD. Address .................................. : Building 17, Tongde Intelligent Manufacturing Park, Ronggui Street, Shunde District, Foshan City, China Product Description Trade Mark ............................. : N/A Product Name ......................... : Digital Camera Model and/or Type Reference : VE418 Standards ............................... : FCC Rules and Regulations Part 15 Subpart C Section 15.247 ANSI C63.10: 2020 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Oct. 14, 2025 ~ Nov. 25, 2025 Date of Issue ........................................... : Nov. 25, 2025 Test Result ............................................... : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 72 Report No.: HK2510145634-E Table of Contents 1. Summary ................................................................................................... 5 1.1 Test Procedures and Results ........................................................................................................... 5 1.2 Information of the Test Laboratory ................................................................................................. 5 1.3 Measurement Uncertainty ................................................................................................................ 6 2. EUT Description ........................................................................................ 7 2.1 General Description of EUT ............................................................................................................. 7 2.2 Carrier Frequency of Channels ........................................................................................................ 8 2.3 Operation of EUT during Testing ..................................................................................................... 8 2.4 Description of Test Setup ................................................................................................................. 9 2.5 Description of Support Units ......................................................................................................... 10 3. General Information ................................................................................ 11 3.1 Test Environment and Mode .......................................................................................................... 11 4. Test Results and Measurement Data .................................................... 13 4.1 AC Conducted Emission ................................................................................................................ 13 4.2 Maximum Peak Conducted Output Power .................................................................................... 17 4.3 Emission Bandwidth ....................................................................................................................... 20 4.4 Power Spectral Density .................................................................................................................. 26 4.5 Conducted Band Edge and Spurious Emission Measurement .................................................. 33 4.6 Radiated Spurious Emission Measurement ................................................................................. 43 4.7 Antenna Requirement ..................................................................................................................... 69 5. Photographs of Test ............................................................................... 70 6. Photos of the EUT ................................................................................... 72 Page 4 of 72 Report No.: HK2510145634-E ** Modified History ** Revision Description Issued Date Remark Revision 1.0 Initial Test Report Release Nov. 25, 2025 Jason Zhou Page 5 of 72 Report No.: HK2510145634-E 1. Summary 1.1 Test Procedures and Results Requirement CFR 47 Section Result Antenna Requirement §15.203/§15.247(b)(4) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247(b)(3) PASS 6dB Emission Bandwidth §15.247(a)(2) PASS Power Spectral Density §15.247(e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. …
Text truncated - open the document above for the full version.
Page 43 of 72 Report No.: HK2510145634-E 4.6 Radiated Spurious Emission Measurement Test Specification Test Requirement: FCC Part15 C Section 15.209 Test Method: ANSI C63.10: 2020 Frequency Range: 9 kHz to 25 GHz Measurement Distance: 3 m Antenna Polarization: Horizontal & Vertical Operation Mode: Transmitting mode with modulation Receiver Setup: Frequency Detector RBW VBW Remark 9kHz- 150kHzQuasi-peak200Hz 1kHz Quasi-peak Value 150kHz- 30MHz Quasi-peak9kHz 30kHz Quasi-peak Value 30MHz-1GHzQuasi-peak120KHz300KHz Quasi-peak Value Above 1GHz Peak 1MHz 3MHz Peak Value Peak 1MHz 10Hz Average Value Limit: Frequency Field Strength (microvolts/meter) Measurement Distance (meters) 0.009-0.490 2400/F(KHz) 300 0.490-1.705 24000/F(KHz) 30 1.705-30 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Frequency Field Strength (microvolts/meter) Measurement Distance (meters) Detector Above 1GHz 500 3 Average 5000 3 Peak Test Setup: For radiated emissions below 30MHz Page 44 of 72 Report No.: HK2510145634-E 30MHz to 1GHz Above 1GHz Test Procedure: 1. For the radiated emission test below 1GHz: The EUT was placed on a turntable with 0.8 meter above ground. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the top of a variable height antenna tower. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high PASS filter are used for the test in order to get better signal level. 2. For the radiated emission test above 1GHz: Place the measurement antenna on a turntable with 1.5 meter above ground, which is away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. Page 45 of 72 Report No.: HK2510145634-E The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. 3. Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level 4. For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. 5. Use the following spectrum analyzer settings: (1) Span shall wide enough to fully capture the emission being measured; (2) Set RBW=120 kHz for f < 1 GHz; VBW ≥RBW; Sweep = auto; Detector function = peak; Trace = max hold; (3) Set RBW = 1 MHz, VBW= 3MHz for f 1 GHz for peak measurement. 6.For average measurement: VBW = 10 Hz, when duty cycle is no less than 98 percent.VBW ≥ 1/T, when duty cycle is less than 98 percent where T is the minimum transmission duration over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Test Results: PASS Page 46 of 72 Report No.: HK2510145634-E Test Instruments Radiated Emission Test Site (966) Name of Equipment Manufacturer Model Serial Number Calibration Date Calibration Due Spectrum analyzer Agilent N9020A HKE-025 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer Agilent N9020A HKE-117 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer R&S FSV3044 HKE-126 Feb. 19, 2025 Feb. 18, 2026 Preamplifier EMCI EMC051845SHKE-006 Feb. 19, 2025 Feb. 18, 2026 Preamplifier Schwarzbeck BBV 9743 HKE-016 Feb. 19, 2025 Feb. 18, 2026 Preamplifier A.H. Systems SAS-574 HKE-182 Feb. 19, 2025 Feb. 18, 2026 6dB Attenuator Pasternack 6db HKE-184 Feb. 19, 2025 Feb. 18, 2026 EMI Test Receiver Rohde & Schwarz ESR-7 HKE-010 Feb. 19, 2025 Feb. 18, 2026 Broadband Antenna Schwarzbeck VULB9168 HKE-167 Feb. 21, 2024 Feb. 20, 2026 Loop Antenna COM-POWER AL-130R HKE-014 Feb. 21, 2024 Feb. 20, 2026 Horn Antenna Schewarzbeck 9120D HKE-013 Feb. 21, 2024 Feb. 20, 2026 EMI Test Software Tonscend JS32-RE 5.0.0HKE-082 / / RSE Test Software Tonscend JS36-RSE 5.0.0 HKE-184 / / Page 47 of 72 Report No.: HK2510145634-E Test Data All the test modes completed for test. Only the worst result was reported as below: Below 1GHz Test Results: Antenna polarity: Horizontal Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level; Page 48 of 72 Report No.: HK2510145634-E Antenna polarity: Vertical Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level; Harmonics and Spurious Emissions Frequency Range (9kHz-30MHz) Frequency (MHz) Level@3m (dBμV/m) Limit@3m (dBμV/m) -- -- -- -- -- -- -- -- -- -- -- -- Note:1. Emission Level=Reading+ Cable loss-Antenna factor-Amp factor. 2. The emission levels are 20 dB below the limit value, which are not reported. It is deemed to comply with the requirement. Page 49 of 72 Report No.: HK2510145634-E Above 1GHz Radiated Emission Test Operation Mode: 802.11b Mode with 2.4G TX CH Low Horizontal: FrequencyReading ResultFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 482452.44-3.6448.87425.2peak 482442.75-3.6439.115414.89AVG 723652.72-0.9551.777422.23peak 723641.6-0.9540.655413.35AVG Remark: Factor = Cable loss + Antenna factor + Attenuator - Preamplifier; Level = Reading + Factor; Margin = Limit - Level. Detector Type Vertical: FrequencyReading ResultFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 482452.22-3.6448.587425.42peak 482441.9-3.6438.265415.74AVG 723650.99-0.9550.047423.96peak 723641.51-0.9540.565413…
Text truncated - open the document above for the full version.
Test Model: VE418 Radiated Emission AC Conducted Emission RF Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 2.40 mW |

Waterproof Camera
Equipment Class
DTS - Digital Transmission System
Digital Camera
Equipment Class
DTS - Digital Transmission System
Portable photo printer
Equipment Class
DTS - Digital Transmission System
Digital Camera
Equipment Class
DTS - Digital Transmission System
Digital Camera
Equipment Class
DTS - Digital Transmission System