  3. 2BO5J-DE001

2BO5J-DE001Antigravity A1

Yingling Innovations Pte. Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 18, 2025
Application Purpose
Original Equipment
Equipment Note
Antigravity A1
Frequency Range
2402.00000000 - 2480.00000000
Company
Yingling Innovations Pte. Ltd.
Country
Singapore

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Page 1 of 1 uncontrolled when printed out TCB FCC Request for Confidentiality Letter Date: 2025-09-11 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BO5J-DE001 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction Yingling Innovations Pte. Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: __________________/Compliance Supervisor ____________ Daniel Lou ____________ (Signature/Title) (Print name) Tel: +86 15899760895 Email: [email protected]

ID Label/Location Info

Product Label and Locaon (On surface of device)

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25NHGT 004 Auftrags-Nr.: Order no.: 168557102 Seite 1 von 16 Page 1 of 16 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-05-20 Auftraggeber: Client: Yingling Innovations Pte. Ltd. 24 Sin Ming Lane #06-97 Midview City, Singapore (573970) Prüfgegenstand: Test item: Antigravity A1 Bezeichnung / Typ-Nr.: Identification / Type no.: DE001 (Trademark: ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 1.1310 CFR Title 47 FCC Part 2.1091 RSS-102 Issue 6 December 2023 AS/NZS 2772.2:2016 Amd 1:2018 Wareneingangsdatum: Date of sample receipt: 2025-06-05 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004005894-043~047 Prüfzeitraum: Testing period: 2025-06-05 - 2025-08-22 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2025-09-08 Ausstellungsdatum: Issue date: 2025-09-08 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BO5J-DE001, IC: 34026-DE001, HVIN: DE001 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25NHGT 004 Test report no.: Seite 2 von 16 Page 2 of 16 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC …

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25NHGT 002 Auftrags-Nr.: Order no.: 168557102 Seite 1 von 26 Page 1 of 26 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-05-20 Auftraggeber: Client: Yingling Innovations Pte. Ltd. 24 Sin Ming Lane #06-97 Midview City, Singapore (573970) Prüfgegenstand: Test item: Antigravity A1 Bezeichnung / Typ-Nr.: Identification / Type no.: DE001 (Trademark: ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15.247 RSS-247 Issue4 July 2025 RSS-Gen Issue 5 February 2021 AS/NZS 4268:2017+A1:2021 Wareneingangsdatum: Date of sample receipt: 2025-06-05 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004005894-043~047 Prüfzeitraum: Testing period: 2025-06-05 - 2025-08-22 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2025-09-08 Ausstellungsdatum: Issue date: 2025-09-08 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BO5J-DE001, IC: 34026-DE001, HVIN: DE001 This report is for Bluetooth LE, 2.4GHz Wi-Fi and 2.4GHz SDR. This report is compliance with CFR Title 47 FCC Part 15.247, according to AS/NZS 4268:2017+A1:2021 section 6.1 it also shows compliance to AS/NZS 4268:2017+A1:2021. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518000, China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25NHGT 002 Test report no.: Seite 2 von 26 Page 2 of 26 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewüns…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 15 of 61 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 16 of 61 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 17 of 61 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 18 of 61 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 19 of 61 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 20 of 61 Appendix B.4: Test Results of Band Edge Measurements Test Result TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict 11B Ant1 Low 2412 11.92 -28.25 ≤-18.08 PASS High 2462 11.52 -39.3 ≤-18.48 PASS 11G Ant1 Low 2412 7.50 -23.05 ≤-22.5 PASS High 2462 8.36 -26.92 ≤-21.64 PASS 11N20SISO Ant1 Low 2412 5.87 -24.64 ≤-24.13 PASS High 2462 8.58 -25.99 ≤-21.43 PASS 11N40SISO Ant1 Low 2422 3.59 -27.94 ≤-26.41 PASS High 2452 3.58 -26.59 ≤-26.42 PASS Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 21 of 61 Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 22 of 61 11G_Ant1_High_2462 11N20SISO_Ant1_Low_2412 11N20SISO_Ant1_High_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 23 of 61 11N40SISO_Ant1_Low_2422 11N40SISO_Ant1_High_2452 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 24 of 61 Appendix B.5: Test Results of Conducted Spurious Emissions Test Result TestMode Antenna Channel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 10.95 10.95 --- PASS 30~1000 10.95 -41.21 ≤-19.05 PASS 1000~26500 10.95 -32.5 ≤-19.05 PASS 2437 Reference 10.37 10.37 --- PASS 30~1000 10.37 -41.5 ≤-19.63 PASS 1000~26500 10.37 -31.63 ≤-19.63 PASS 2462 Reference 10.79 10.79 --- PASS 30~1000 10.79 -40.5 ≤-19.21 PASS 1000~26500 10.79 -32.56 ≤-19.21 PASS 11G Ant1 2412 Reference 7.64 7.64 --- PASS 30~1000 7.64 -41.51 ≤-22.36 PASS 1000~26500 7.64 -32.1 ≤-22.36 PASS 2437 Reference 5.19 5.19 --- PASS 30~1000 5.19 -41.72 ≤-24.81 PASS 1000~26500 5.19 -32.86 ≤-24.81 PASS 2462 Reference 7.03 7.03 --- PASS 30~1000 7.03 -42.01 ≤-22.97 PASS 1000~26500 7.03 -32.32 ≤-22.97 PASS 11N20SISO Ant1 2412 Reference 7.20 7.20 --- PASS 30~1000 7.20 -41.12 ≤-22.8 PASS 1000~26500 7.20 -32.14 ≤-22.8 PASS 2437 Reference 5.45 5.45 --- PASS 30~1000 5.45 -40.61 ≤-24.55 PASS 1000~26500 5.45 -31.82 ≤-24.55 PASS 2462 Reference 5.22 5.22 --- PASS 30~1000 5.22 -41.14 ≤-24.78 PASS 1000~26500 5.22 -32.71 ≤-24.78 PASS 11N40SISO Ant1 2422 Reference 5.82 5.82 --- PASS 30~1000 5.82 -41.83 ≤-24.18 PASS 1000~26500 5.82 -32.35 ≤-24.18 PASS 2437 Reference 5.62 5.62 --- PASS 30~1000 5.62 -41.47 ≤-24.38 PASS 1000~26500 5.62 -32.32 ≤-24.38 PASS 2452 Reference 3.66 3.66 --- PASS 30~1000 3.66 -40.73 ≤-26.34 PASS 1000~26500 3.66 -32.41 ≤-26.34 PASS Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 25 of 61 Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 26 of 61 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 27 of 61 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 28 of 61 11G_Ant1_2412_0~Reference 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 29 of 61 11G_Ant1_2437_0~Reference 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 30 of 61 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 31 of 61 11N20SISO_Ant1_2412_0~Reference 11N20SISO_Ant1_2412_30~1000 11N20SISO_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 32 of 61 11N20SISO_Ant1_2437_0~Reference 11N20SISO_Ant1_2437_30~1000 11N20SISO_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 33 of 61 11N20SISO_Ant1_2462_0~Reference 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 34 of 61 11N40SISO_Ant1_2422_0~Reference 11N40SISO_Ant1_2422_30~1000 11N40SISO_Ant1_2422_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 35 of 61 11N40SISO_Ant1_2437_0~Reference 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 36 of 61 11N40SISO_Ant1_2452_0~Reference 11N40SISO_Ant1_2452_30~1000 11N40SISO_Ant1_2452_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 37 of 61 Prüfbericht - Produkte Test Report - Products Appendix B CN25NHGT 002 Page 38 of 61 Appendix B.6: Test Results of Radiated Spurious Emissions Note: 1) This testing was carried out on different modulations, but only the worst case was presented in this report. 2) Testing was carried out within frequency range 9kHz to the tenth harmonics. The measurement results below 30MHz and 18GHz - 26.5GHz were greater than 20dB below the limit, so only the radiated spurious emissions from 30MHz to 18GHz were reported. 30MHz - 1GHz EUT Information EUT Name: Antigravity A1 Model: DE001 Test Mode: WIFI 2.4G_11b_Ch6 Order No/Sample No: 168557102/A004005894-047 Test Voltage: Battery Remark: Temp 24 Humi:50% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 4 of 20 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 5 of 20 Appendix E.2: Test Results of 99% Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 20M Ant1 2415 18.742 2405.6878 2424.4298 --- PASS 2440 18.894 2430.6145 2449.5085 --- PASS 2460 19.036 2450.3780 2469.4140 --- PASS Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 6 of 20 Test Graphs 20M_Ant1_2415 20M_Ant1_2440 20M_Ant1_2460 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 7 of 20 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 8 of 20 Appendix E.3: Test Results of Conducted Power Spectral Density Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict 20M Ant1 2415 -6.11 ≤8.00 PASS Ant2 2415 -5.52 ≤8.00 PASS Ant1 2440 -1.70 ≤8.00 PASS Ant2 2440 -1.06 ≤8.00 PASS Ant1 2460 -3.30 ≤8.00 PASS Ant2 2460 -3.56 ≤8.00 PASS Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 9 of 20 Test Graphs 20M_Ant1_2415 20M_Ant2_2415 20M_Ant1_2440 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 10 of 20 20M_Ant2_2440 20M_Ant1_2460 20M_Ant2_2460 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 11 of 20 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 12 of 20 Appendix E.4: Test Results of Band Edge Measurements Test Result TestMode Antenna ChName Channel RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 20M Ant1 Low 2415 7.60 -34.11 ≤-22.40 PASS High 2460 13.27 -42.86 ≤-16.73 PASS Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 13 of 20 Test Graphs 20M_Ant1_Low_2415 20M_Ant1_High_2460 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 14 of 20 Appendix E.5: Test Results of Conducted Spurious Emission Test Result TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 20M Ant1 2415 Reference 10.62 10.62 --- PASS 30~1000 10.62 -41.56 ≤-19.38 PASS 1000~26500 10.62 -32.7 ≤-19.38 PASS 2440 Reference 16.59 16.59 --- PASS 30~1000 16.59 -41.4 ≤-13.41 PASS 1000~26500 16.59 -32.24 ≤-13.41 PASS 2460 Reference 14.14 14.14 --- PASS 30~1000 14.14 -41.22 ≤-15.86 PASS 1000~26500 14.14 -32.46 ≤-15.86 PASS Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 15 of 20 Test Graphs 20M_Ant1_2415_0~Reference 20M_Ant1_2415_30~1000 20M_Ant1_2415_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 16 of 20 20M_Ant1_2440_0~Reference 20M_Ant1_2440_30~1000 20M_Ant1_2440_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 17 of 20 20M_Ant1_2460_0~Reference 20M_Ant1_2460_30~1000 20M_Ant1_2460_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 18 of 20 Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 19 of 20 Appendix E.6: Test Results of Conducted Emission on AC Mains EUT Information EUT Name Antigravity A1 Order Number: 168557102 220 Model: DE001 Test Mode: On, Normal Operation wth wireless link Test Voltage: AC 120V60Hz Test Standard: FCC Part 15B Test By:/Review By: Simon Feng/Murphy Chen Tem./Hum./Pressure: 24.9°C/52.4%/101kPa Remark: SR2 Critical_Freqs Frequency (MHz) MaxPeak (dBμV) Average (dBμV) Limit (dBμV) Margin (dB) Line Corr. (dB) 0.152 --- 25.91 55.91 30.00 L1 10.2 0.157 47.01 --- 65.64 18.63 L1 10.2 0.478 31.66 --- 56.37 24.71 L1 10.2 0.510 --- 23.14 46.00 22.86 L1 10.2 2.055 29.69 --- 56.00 26.31 L1 10.3 2.085 --- 20.10 46.00 25.90 L1 10.3 2.133 31.53 --- 56.00 24.47 L1 10.3 2.243 --- 20.70 46.00 25.30 L1 10.3 9.861 33.52 --- 60.00 26.48 L1 10.6 10.241 --- 24.54 50.00 25.46 L1 10.6 12.810 38.47 --- 60.00 21.53 L1 10.7 12.936 --- 29.31 50.00 20.69 L1 10.7 Final_Result Frequency (MHz) QuasiPeak (dBμV) CAverage (dBμV) Limit (dBμV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB) --- --- --- --- --- --- --- --- 0 20 40 60 80 100 150k 300 400500 8001M2M 3M 4M 5M 6 8 10M20M 30M Level in dB 礦 Frequency in Hz Prüfbericht - Produkte Test Report - Products Appendix E CN25NHGT 002 Page 20 of 20 EUT Information EUT Name Antigravity A1 Order Number: 168557102 220 Model: DE001 Test Mode: On, Normal Operation wth wireless link Test Voltage: AC 120V60Hz Test Standard: FCC Part 15B Test By:/Review By: Simon Feng/Murphy Chen Tem./Hum./Pressure: 24.9°C/52.4%/101kPa Remark: SR2 Critical_Freqs Frequency (MHz) MaxPeak (dBμV) Average (dBμV) Limit (dBμV) Margin (dB) Line Corr. (dB) 0.150 48.78 --- 66.00 17.22 N 10.2 0.150 --- 24.91 56.00 31.09 N 10.2 0.178 --- 29.55 54.57 25.02 N 10.2 0.180 45.99 --- 64.49 18.50 N 10.2 0.447 --- 22.66 46.93 24.28 N 10.2 0.447 34.17 --- 56.93 22.77 N 10.2 2.054 29.26 --- 56.00 26.74 N 10.3 2.344 --- 20.72 46.00 25.28 N 10.3 13.224 39.67 --- 60.00 20.33 N 10.7 13.413 --- 30.95 50.00 19.05 N 10.7 17.694 33.50 --- 60.00 26.50 N 10.9 17.738 --- 24.49 50.00 25.51 N 10.9 Final_Result Frequency (MHz) QuasiPeak (dBμV) CAverage (dBμV) Limit (dBμV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB) --- --- --- --- --- --- --- --- 0 20 40 60 80 100 150k 300 400500 8001M2M 3M 4M 5M 6 8 10M20M 30M Level in dB 礦 Frequency in Hz Prüfbericht - Produkte Test Report - Products Appendix F CN25NHGT 002 Page 1 of 20 Appendix F: Test Results of 2.4G SDR_40MHz BW APPENDIX F: TEST RESULTS OF 2.4G SDR_40MHZ BW......................................................................................................... 1 APPENDIX F.1: TEST RESULTS OF 6DB BANDWIDTH ..................................................................................................................... 2 Test Result ...................................................................................................................................................................... 2 Test Graphs....................…

Text truncated - open the document above for the full version.

Test Report

DE Antenna Test Report Yingling Innovations Pte. Ltd. 24 Sin Ming Lane #06-97 Midview City, Singapore (573970) Basic Specifications SpecificationDescriptions Model Name GNSS FL FR BL BR Frequency 1561.098±2.045MHz&1575.42MHz±1.023MHz 2400~2483.5MHz&5150~5250MHz&5725~5850MHz Connector TypeWELD&I-PEX Gain GNSS [email protected]±2.045MHz/ [email protected]±1.023MHz FL 1.06dBi@2400~2483.5MHz/ 0.23dBi@5150~5350MHz/ 1.70dBi@5725~5850MHz FR 0.85dBi@2400~2483.5MHz/ 0.48dBi@5150~5350MHz/ 1.58dBi@5725~5850MHz BL 0.82dBi@2400~2483.5MHz/ 0.40dBi@5150~5350MHz/ 1.39dBi@5725~5850MHz BR 0.89dBi@2400~2483.5MHz/ 0.44dBi@5150~5350MHz/ 1.29dBi@5725~5850MHz VSWR/S11 Gain Frequency(MHz)155815591560156115621563156415731574157515761577 Gain(dBi) 0.641.101.361.361.100.600.05-0.510.110.320.25-0.14 Polar RC.(dBi) -1.00-0.56-0.31-0.31-0.57-1.06-1.58-1.23-0.65-0.54-0.69-1.16 GNSS Gain Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi) 0.440.580.690.630.801.060.830.880.780.750.72 Frequency(MHz)5150520052505700575058005850 Gain(dBi) 0.230.100.141.121.201.701.12 FL Gain Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi) 0.660.660.740.850.700.700.350.420.270.270.19 Frequency(MHz)5150520052505700575058005850 Gain(dBi) 0.370.480.331.421.481.581.56 FR Gain Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi) 0.520.570.620.730.820.770.770.620.510.500.31 Frequency(MHz)5150520052505700575058005850 Gain(dBi) 0.330.400.381.151.351.391.33 BL Gain Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi) 0.290.390.350.390.750.890.650.690.830.750.62 Frequency(MHz)5150520052505700575058005850 Gain(dBi) 0.360.310.441.081.291.070.77 BR Radiation pattern GNSS Theta=90° XOY面 Phi=90° YOZ面 Phi=0° XOZ面 Radiation pattern FL Theta=90° XOY面 Phi=90° YOZ面 Phi=0° XOZ面 Radiation pattern FR Theta=90° XOY面 Phi=90° YOZ面 Phi=0° XOZ面 Radiation pattern BL Theta=90° XOY面 Phi=90° YOZ面 Phi=0° XOZ面 Radiation pattern BR Theta=90° XOY面 Phi=90° YOZ面 Phi=0° XOZ面 Thank You

Contact Information

Applicant

Daniel Lou(Compliance Supervisor)
[email protected]Fax: 0755-23324884

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.50 mW
215C2.40 GHz - 2.47 GHz907.80 mW
315C2.41 GHz - 2.46 GHz972.70 mW
415C2.42 GHz - 2.46 GHz933.30 mW
515C2.42 GHz - 2.46 GHz955.00 mW
615C2.41 GHz - 2.46 GHz96.20 mW
715C2.42 GHz - 2.45 GHz87.90 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End user must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device contains 5.2GHz & 5.8GHz WLAN and wireless transmitters.