2BOAU-PB600Manual Alarm Button, body worn

Kadex B.V.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 15, 2026
Application Purpose
Original Equipment
Equipment Note
Manual Alarm Button, body worn
Frequency Range
902.00000000 - 928.00000000
Company
Kadex B.V.
Country
Netherlands

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 2026-04-20 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b) (4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID 2BOAU-PB600 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Description The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device, which is planned for October 17th, 2026.

ID Label/Location Info

1 Label design Below a description is made of the label that will be placed on the Personal Button / Personal Bracelet. The label will be laser printed on the backside of the Personal Button / Personal Bracelet. To inform the end-user about both FCC and ISED certification and certified radios used in the device, this information is shown in both this manual and on the label that is placed on the box in which the Personal Button / Personal Bracelet is delivered to the end-user. The size of the label on the Personal Button / Personal Bracelet is 20x20 mm and the label size on the box is 40x70mm. 1.1 Label overview Below are the outlines of the label on the Personal Button / Personal Bracelet. All variants are included. Note that the color code is only added on the label of the box of the device. Personal Bracelet no BLE (art. no. 210231099B) Personal Bracelet BLE (art. no. 210231299B) Personal Bracelet Tracking only + BLE (art. no. 210231599B) Personal Bracelet Easy Touch (art. no. 210231799B) Personal Bracelet Easy Touch BLE (art. no. 210231899B) 2 Personal Button (art. no. 210231099) Personal Button BLE (art. no. 210231299) Personal Button BLE Tracking only (art. no. 210231599) Below is a picture as an example of the label on the device. Personal Bracelet no BLE (art. no. 210231099B) Personal Bracelet BLE (art. no. 210231299B) Personal Bracelet Tracking only + BLE (art. no. 210231599B) Personal Bracelet Easy Touch (art. no. 210231799B) 3 Personal Bracelet Easy Touch BLE (art. no. 210231899B) Personal Button (art. no. 210231099) Personal Button BLE (art. no. 210231299) Personal Button BLE Tracking only (art. no. 210231599) 4 Below are the outlines of the label on the box of the device. Personal Bracelet no BLE (art. no. 210231099B) White Blue Green Pink Grey 5 Personal Bracelet BLE (art. no. 210231299B) White Blue Green Pink Grey 6 Personal Bracelet Tracking only + BLE (art. no. 210231599B) White Blue Green Pink Grey 7 Personal Bracelet Easy Touch (art. no. 210231799B) White Blue Green Pink Grey 8 Personal Bracelet Easy Touch BLE (art. no. 210231899B) White Blue Green Pink Grey 9 Personal Button (art. no. 210231099) White Blue Green Pink Grey 10 Personal Button BLE (art. no. 210231299) White Blue Green Pink Grey 11 Personal Button BLE Tracking only (art. no. 210231599) White Blue Green Pink Grey 12 1.2 Label items explained See below for the explanation of all items on the label on a Personal Button. The same applies to the Personal Bracelet. For all variants the label design is the same, only the article number is different. See below for the explanation of all items on the label on the box of a device. Note that the article number, color code, product name and color are different based on the combinations. See for all versions of the labels 1.1. 13 1.3 Label placing on product Below you can see an example of the location of the label on the Personal Bracelet. The label is located at the backside of the Personal Bracelet. The same applies to the Personal Button. Personal Bracelet no BLE (art. no. 210231099B) Personal Bracelet BLE (art. no. 210231299B) Personal Bracelet Tracking only + BLE (art. no. 210231599B) Personal Bracelet Easy Touch (art. no. 210231799B) Personal Bracelet Easy Touch BLE (art. no. 210231899B) 14 Personal Button (art. no. 210231099) Personal Button BLE (art. no. 210231299) Personal Button BLE Tracking only (art. no. 210231599) Below you can see the location of the label on the box of the Personal Button. The label is located at the side of the box.

RF Exposure Info

© cetecom advanced GmbH Page 1 of 36 TEST REPORT Test Report No.: 1-9816-25-06-02_TR1-R01 Testing Laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 Kadex B.V. Bijsterhuizen 2213 6604 LC Wijchen/NETHERLANDS Phone: Contact: Serge Kalkhoven e-mail: Phone: Fax: Manufacturer Kadex B.V. Bijsterhuizen 2213 6604 LC Wijchen/NETHERLANDS Test Standards IEC/IEEE 62209-1528-2020 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Part 1528: Human models, instrumentation, and procedures (Frequency range of 4 MHz to 10 GHz) RSS-102 Issue 6 Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Manual Alarm Device type: portable device Model name: Personal Button BLE S/N serial number: 1 FCC-ID: 2BOAU-PB600 / Contains FCC ID: 2AAQS-ISP1507 ISED Number: 35650-PB600 / Contains IC: 11306A-ISP1507 Product Marketing Name (PMN): 210231299 Hardware Version Identification No. (HVIN): PB600 Hardware status: V6.00 Software status: 07.21 Frequency: LBT 915 MHz (tested) & BLE 2.4 GHz (excluded) Antenna: integrated antenna Battery option: integrated battery Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: Alexander Hnatovskiy Obada Abo Oun Coordinator Area Testing Manager Regulatory Services Radio Regulatory Services Radio Test report no.: 1-9816-25-06-02_TR1-R01 © cetecom advanced GmbH Page 2 of 36 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 4 2.1 Notes and disclaimer .......................................................................................................................... 4 2.2 Application details ............................................................................................................................... 4 2.3 Statement of compliance .................................................................................................................... 4 3 Test standards/ procedures references ....................................................................................................... 5 3.1 RF exposure limits .............................................................................................................................. 6 4 Reporting statements of conformity – decision rule .................................................................................. 7 5 Summary of Measurement Results .............................................................................................................. 8 5.1 SAR measurement variability and measurement uncertainty analysis ......................................... 8 6 Test Environment ........................................................................................................................................... 8 7 Test Set-up ...................................................................................................................................................... 9 7.1 Measurement system .......................................................................................................................... 9 7.1.1 System Description ..................................................................................................................... 9 7.1.2 Test environment ...................................................................................................................... 10 7.1.3 Probe description ...................................................................................................................... 10 7.1.4 Phantom description ................................................................................................................. 11 7.1.5 Device holder description ......................................................................................................... 11 7.1.6 Scanning procedure .................................................................................................................. 12 7.1.7 Spatial Peak SAR Evaluation ................................................................................................... 16 7.1.8 Data Storage and Evaluation .................................................................................................... 18 7.1.9 Tissue simulating liquids: dielectric properties ......................................................................... 20 7.1.10 Tissue simulating liquids: parameters ...................................................................................... 20 7.1.11 Measurement uncertainty evaluation for SAR test ................................................................... 21 7.1.12 Measurement uncertainty evaluation for System …

Text truncated - open the document above for the full version.

RF Exposure Info

cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 1 of 26 Annex A201 – Calibration Data No. 1-9816-25-06-02_TR1-A201-R01 This test report is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. September 3, 2026 authorized by Alexander Hnatovskiy Coordinator Area Regulatory Services Radio Description Detailed SAR System calibration data cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 2 of 26 Table of content 1 Calibration report “Probe EX3DV4 – SN: 7566” .................................................................................................... 3 2 Calibration report “900 MHz System check dipole” ........................................................................................... 13 3 Calibration certificate of Data Acquisition Unit (DAE) – SN: 1387 .................................................................... 19 4 Certificate of “SAM Twin Phantom V8.0” ............................................................................................................ 20 5 Application note system performance check ..................................................................................................... 21 5.1 Purpose of system performance check ........................................................................................................ 21 5.2 System performance check procedure ......................................................................................................... 21 5.3 Uncertainty Budget ......................................................................................................................................... 22 5.4 Power set-up for validation ............................................................................................................................ 25 5.5 Laboratory reflection ...................................................................................................................................... 26 5.6 Additional system checks .............................................................................................................................. 26 2012- cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 3 of 26 1 Calibration report “Probe EX3DV4 – SN: 7566” cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 4 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 5 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 6 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 7 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 8 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 9 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 10 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 11 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 12 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 13 of 26 2 Calibration report “900 MHz System check dipole” cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 14 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 15 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 16 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 17 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 18 of 26 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 19 of 26 3 Calibration certificate of Data Acquisition Unit (DAE) – SN: 1387 cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 20 of 26 4 Certificate of “SAM Twin Phantom V8.0” cetecom advanced GmbH Document No. 1-9816-25-06-02_TR1-A201-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 21 of 26 5 Application note system performance check 5.1 Purpose of system performance check The system performance check verifies that the system operates within its specifications. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many parameters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the flat section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to gi…

Text truncated - open the document above for the full version.

Test Report

IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 1 of 7 Kadex Personal Button V6.00 (DEV915057A): internal pcb antenna for 915 MHz and antenna for BLE author: René Gruhle date: 26.05.2026 update: 29.07.2026, Jens Riedel figure 1: antenna section antenna type: F-antenna implementation: microstrip on FR4 dimensions: approx. 33.7mm x 20.8mm IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 2 of 7 RF characteristics: figure 2: DUT mounted on antenna rotating stand Parameter 902MHz 915MHz 928MHz Directivity 2.4dBi 2.4dBi 2.0dBi Peak gain -12.2dBi -11.9dBi -16.0dBi Efficiency 3,5% 3,7% 1,6% Impedance (with matching) 50Ω 50Ω 50Ω IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 3 of 7 figure 3: antenna peak gain over frequency at 915 MHz band IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 4 of 7 Matching: DUT on a wooden board and on the body figure 4: test setup return loss, DUT on a wooden board and on the body figure 5: antenna matching +80 MHz 5 dB/ -40 dB 10 dB CH15 dB/REF 0 dB CENTER915 MHzSPAN200 MHz20 MHz/ MAGdB FIL 10k10k FIL 10k10k CPL OFS CAL S11 1 2 3 1: -22.54 dB 915 MHz 2: -9.898 dB 905.625 MHz 3: -10.14 dB 921.375 MHz á 0 dB Date: 14.MAY.25 13:41:15 00.20.512510 -5 -2 -1 -0.5 0.5 1 2 5 CH1 ­ 1 U CENTER915 MHzSPAN200 MHz FIL 10k10k FIL 10k10k CPL OFS CAL S11 1 2 3 1: 43.57 ê -j1.764 ê 915 MHz 2: 40.46 ê j28.89 ê 905.625 MHz 3: 28.66 ê -j11.84 ê 921.375 MHz Date: 14.MAY.25 13:41:37 IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 5 of 7 Antenna patterns: figure 6: 3D pattern at 902MHz figure 7: 3D pattern at 915MHz figure 8: 3D pattern at 928MHz IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 6 of 7 BLE antenna The antenna for BLE is part of the BLE-module ISP1507 from insight SIP. The antenna is located under the black plastic part. figure 9: BLE module, integrated on the Personal Button PCB (right picture) The measured antenna gain (see figure below) for BLE on the Personal Button. figure 10: antenna peak gain over frequency at 2400 MHz band (BLE). 2402 MHz = channel 37, 2440 MHz = channel 17, 2480 MHz = channel 39 IK Elektronik GmbH Kadex_Personal_Button_antenna_915MHz_and_BLE_update.docx page 7 of 7 Test setup and equipment: • DUT in TX CW mode (test mode) • Rohde & Schwarz ZVCE VNA • Anritsu MS2830A signal analyzer • Schwarzbeck USLP 9143 UHF-SHF log. - per. broadband antenna • Self-build antenna rotating and anechoic chamber for radiated measurements

Test Report

Annex 301 – Declarations No. 1-9816-25-02-04_TR1-A301-R01 June 26, 2026 cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A301-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 1 of 4 Description Declaration of untested variants This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. authorized by Timo Franke Lab Manager Compliance Testing & Innovation cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A301-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 2 of 4 1 Declarations cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A301-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 3 of 4 cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A301-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 4 of 4 Document History Release Applied changes Release date R01 Initial release June 26, 2026 - END OF DOCUMENT -

Test Report

Conducted test results No.1-9816-25-02-04_TR1-A201-R01 May 20, 2026 Test Standard(s)FCC 15.247 - NI NA - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Timo Franke Lab Manager Compliance Testing & Innovation cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 1 of 51 Table of Content FCC 15.247 # Maximum peak conducted output power ~ Generic 0G9 hopp3 FCC 15.247 # Bandwidth 99pct ~ Generic 0G9 hopp8 FCC 15.247 # Bandwidth 20dB ~ Generic 0G9 hopp15 FCC 15.247 # TX spurious conducted 20dBc ~ Generic 0G9 hopp23 FCC 15.247 # TX spurious conducted 20dBc ~ Generic 0G9 hopp30 FCC 15.247 # TX spurious conducted 20 dBc ~ Generic 0G9 hopp33 NA # Hardcopy SA ~ Time of occupancy 10s36 NA # Hardcopy SA ~ Time of occupancy single38 NA # Hardcopy SA ~ Number of hopping channels SET2_ID040 NA # Hardcopy SA ~ Carrier frequency separation SET2_ID042 NA # Hardcopy SA ~ Number of hopping frequencies SET3_ID444 NA # Hardcopy SA ~ Carrier frequency separation SET3_ID446 NA # Hardcopy SA ~ Number of hopping frequencies SET4_ID1048 NA # Hardcopy SA ~ Carrier frequency separation SET4_ID1050 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 2 of 51 FCC 15.247 # Maximum peak conducted output power ~ Generic 0G9 hopp References TC start18.05.2026 07:59:10 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version6.0.6.5 Standard | Version FCC 15.247 | NI Method DescriptionFCC 15.247 Maximum Peak Output Power Conducted FHSS Information Equipment Signal analyzer,Rohde&Schwarz,FSW-50,1331.5003K50/101929,6.31 Switch matrix,cetecom advanced GmbH,USM,D001,1.0.0 Test Parameter Technology to testGeneric 0G9 hopp EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 902.4 Frequency mid to testTrue | Freq [MHz] 914.8 Frequency high to testTrue | Freq [MHz] 927.6 Auto control enabled power supply | Climatic Box No | No Additional path loss [dB]0.3 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/ Switch bits 00000001:00000001:00000000:00000110 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 3 of 51 Test at TX 902.4 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------17.65dBmINFO Ref. frequency------902.500MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]22.65 | 2.18 | 31 Start [MHz] | Stop [MHz]901.650 | 903.150 RBW [MHz] | VBW [MHz]1.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type200 | 50 | 1001 | SWE 901.80902.00902.20902.40902.60902.80903.00 MHz Frequency 30.0 28.0 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 10.0 dBm Magni t u de Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power---3017.71dBmPASS Frequency at peak------902.31MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 4 of 51 Test at TX 914.8 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------17.92dBmINFO Ref. frequency------914.900MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]22.92 | 2.2 | 31 Start [MHz] | Stop [MHz]914.050 | 915.550 RBW [MHz] | VBW [MHz]1.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type200 | 50 | 1001 | SWE 914.20914.40914.60914.80915.00915.20915.40 MHz Frequency 30.0 28.0 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 10.0 dBm Magni t u de Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power---3017.99dBmPASS Frequency at peak------914.719MHzINFO cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 5 of 51 Test at TX 927.6 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------17.40dBmINFO Ref. frequency------927.500MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]22.40 | 2.23 | 31 Start [MHz] | Stop [MHz]926.850 | 928.350 RBW [MHz] | VBW [MHz]1.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type200 | 50 | 1001 | SWE 927.00927.20927.40927.60927.80928.00928.20 MHz Frequency 30.0 28.0 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 10.0 dBm Magni t u de Peak output power RESULT DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Peak power---3017.45dBmPASS Frequency at peak------927.507MHzINFO Verdict cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 6 of 51 PASS cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9816-25-02-04_TR1-A201-R01 Release 1 - Page 7 of 51 FCC 15.247 # Bandwidth 99pct ~ Generic 0G9 hopp References TC start15.05.2026 10:27:15 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version6.0.6.5 Standard | Version FCC 15.247 | NI Method DescriptionFCC 15.247 Bandwidth 99pct FHSS Information Equipment Signal analyzer,Rohde&Schwarz,FSW-50,1331.5003K50/101929,6.31 Switch matrix,cetecom advanced GmbH,USM,D001,1.0.0 Test Parameter Technology to testGeneric 0G9 hopp EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 902.4 Frequency mid to testTrue | Freq [MHz] 914.8 Frequency high to testTrue | Freq [MHz] 927.6 Auto control enabled power supply | Climatic Box No | No Additional path loss [dB]0.3 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/ Switch bits 00000001:0000000…

Text truncated - open the document above for the full version.

Test Report

Annex 202 – Test Results No. 1-9816-25-02-04_TR1-A202-R01 June 26, 2026 cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A202-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 1 of 17 Description Test Result Diagrams This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. authorized by Timo Franke Lab Manager Compliance Testing & Innovation cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A202-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 2 of 17 1 Measurement diagrams EUT Information for all following tests Sample: 59.738 Power Supply : 3 V DC 2.01_RSE_ch0_standing Common Information Test description: Magnetic Field Strength Measurement related to 30/300 m distance Test Site Location: Ref.-Nr. 441 Semi Anechoic Chamber (SAC1) with 3 m measurement distance Version of Testsoftware: EMC32 V10.60.20 Distance correction: used accord. table, pls. see test report Technical Data: Please see page 2 for detailed data of measurement setup Rec. antenna (pre-scan): height 1.00 m, parallel and 90° to EUT polarisation Used filter: bypass Test Standard: FCC 15.205 § 15.209; RSS-Gen: Issue 5 Operator: PShin Operating Mode: TX 902.4 MHz, PWR 18 Comment 1: Channel Low Environmental Conditions: Humidity: 50 % rH; Temperature: 22.8 °C EUT Setup: 1 Verdict: Passed -50 -40 -30 -20 -10 0 10 20 30 40 50 60 9k203050100k2003005001M2M3M5M10M2030M Level in dBμV/m Frequency in Hz Full Spectrum FCC15.209_Magnetic_Field 17,080 kHz -24,427 dBμV/m 34,200 kHz -33,489 dBμV/m 52,840 kHz -36,992 dBμV/m cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A202-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 3 of 17 2.02_RSE_ch0_lying Common Information Test description: Magnetic Field Strength Measurement related to 30/300 m distance Test Site Location: Ref.-Nr. 441 Semi Anechoic Chamber (SAC1) with 3 m measurement distance Version of Testsoftware: EMC32 V10.60.20 Distance correction: used accord. table, pls. see test report Technical Data: Please see page 2 for detailed data of measurement setup Rec. antenna (pre-scan): height 1.00 m, parallel and 90° to EUT polarisation Used filter: bypass Test Standard: FCC 15.205 § 15.209; RSS-Gen: Issue 5 Operator: PShin Operating Mode: TX 902.4 MHz, PWR 18 Comment 1: Channel Low Environmental Conditions: Humidity: 50 % rH; Temperature: 22.8 °C EUT Setup: 1 Verdict: Passed -50 -40 -30 -20 -10 0 10 20 30 40 50 60 9k203050100k2003005001M2M3M5M10M2030M Level in dBμV/m Frequency in Hz Full Spectrum FCC15.209_Magnetic_Field 17,080 kHz -21,610 dBμV/m 34,200 kHz -32,871 dBμV/m52,840 kHz -36,617 dBμV/m cetecom advanced GmbH Document No. 1-9816-25-02-04_TR1-A202-R01 Untertuerkheimer Str. 6-10, 66117 Saarbruecken Page 4 of 17 2.03_RSE_ch31_standing Common Information Test description: Magnetic Field Strength Measurement related to 30/300 m distance Test Site Location: Ref.-Nr. 441 Semi Anechoic Chamber (SAC1) with 3 m measurement distance Version of Testsoftware: EMC32 V10.60.20 Distance correction: used accord. table, pls. see test report Technical Data: Please see page 2 for detailed data of measurement setup Rec. antenna (pre-scan): height 1.00 m, parallel and 90° to EUT polarisation Used filter: bypass Test Standard: FCC 15.205 § 15.209; RSS-Gen: Issue 5 Operator: PShin Operating Mode: TX 914.8 MHz, PWR 18 Comment 1: Channel Mid Environmental Conditions: Humidity: 50 % rH; Temperature: 22.8 °C EUT Setup: 1 Verdict: Passed -50 -40 -30 -20 -10 0 10 20 30 40 50 60 9k203050100k2003005001M2M3M5M10M2030M Level in dBμV/m Frequency in Hz Full Spectrum FCC15.209_Magnetic_Field 17,080 kHz -23,818 dBμV/m 34,280 kHz -33,539 dBμV/m 52,840 kHz -36,921 dBμV/m cetecom advanced GmbH Document No. 1-9816-25-02-0…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jip Dorrestein(Business developer)
[email protected]Fax: +31246488280

Technical Contact

ASSA ABLOY Global SolutionsMichael Scott
[email protected]

2925 E. Plano Parkway · Plano, 75074 · United States

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]Fax: +49 681 598 8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902 MHz - 928 MHz63.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. The highest reported SAR for extremities and body-worn SAR exposure conditions are 0.797W/kg and 1.071 W/kg respectively.