Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ModeI NO.: DOM-WLE-SFQ Input VoItage: DC 5V-48V Output Current/ChanneI:10A Max TotaI Output Current:16A Max (25A repIaceabIe fuse) Protection: Intput Reverse PoIarity Protection Working Temperature: -20~45°C WireIess Communication: WiFi Dimensions: 64×80×37mm Brown = V+, Blue = GND (Shared Power) OUTPUT 1-2: Black = I018 (CH1), Yellow-Green =IO17 (CH2) OUTPUT 3-4: Black = 1016 (CH3), Yellow-Green = IO2 (CH4) Standard LED Strip Connection V+(Red) Output Port Definition, The controIIer is equipped with two 4-wire output ports, featuring the foIIowing connections: WLED ControIIer Wiring Guide: Brown wire: V+ (Positive power suppIy Strip VCC) Red protective caps prevent short circuits BIue wire: GND (Ground/Negative) YeIIow+green wire: IO17 (Data signaI Iine) Black wire: IO18 (Data signaI Iine) YeIIow+green wire: IO2 (Data signaI Iine) Black wire: IO16 (Data signaI Iine) Firmware update (OTA): PIease perform the firmware update carefuIIy, and you must seIect the correct fiIe. Otherwise,this may cause functionaI abnormaIities or even damage to the device. For detaiIs, pIease scan the QR code to refer to the OTA instructions. ROHS 1. Ensure power suppIy voItage matches LED strip requirements. 2. For Iong-distance transmission, use signaI ampIifiers. 3. AppIy waterproof insuIation in humid environments. Important Notes: Safety & Operation Notes ALWAYS power off before wiring. Verify poIarity - reverse connection may damage equipment. To prevent short circuits between the data and power Iines, do not remove the red protective cap untiI the LED strip is properIy connected. SignaI attenuation may occur with Iong cascaded strips. Attention 1.R eset operation: After power off, wait f or the LED to compIeteIy turn off bef or e powering it back on, repeat 5 times. (CompIeted within 10 seconds) 2.Success sign: A f ter the 5th power-on, w ait f or the LED to fIash 10 times, then the y eIIow Iight sta ys on (30 ICs working).When powered on again, the LED does not Iight up . That is, the r eset is successfuI. 3.Subsequent Conf igur ation: The r eIa y GPIO12 must be conf igur ed, and the device must be powered on again; otherwise, the LED strip wiII not iIIuminate . NOTE: LED Strip ControIIer Reset & Configuration Quick Guide: Attention README ①Power-on must be done onIy after aII LEDs ar e compIeteIy off. ②The f iv e power-on operations must be compIeted within 10 seconds. ③GPIO12 must be conf igur ed af ter reset. TroubIeshooting: If reset faiIs, wait 60 seconds and then reset again (reset must be re-performed). 1. Ensure aII wiring connections are properIy instaIIed and secur eIy fastened before powering on the device. Never per form instaIIation or adjustments when the device is energized. 2. Oper ate the product onIy within its rated voItage range. OvervoItage or undervoItage may cause permanent damage. 3. Do not disassembIe the product, as it may cause fire and eIectric shock. 4. Do not use in metaI-shieIded areas or near strong magnetic fieIds, as this may severeIy degrade wireIess signaI performance. 1. This manuaI is subject to revisions based on product improvements. Updated versions wiII be pubIished without prior notice. DISCLAIMERS DOM-WLE-SFQ_ V1.2 Scan to view the detaiI manuaI EmaiI: [email protected] EU REP CALLE RIO TORMES NUM.1,PLANTA 1, DERECHA OFICINA 3,FuenIabrada,Madrid,28947 spain [email protected] SUCCESS COURIER SL DOMRAEM LED Strip Controller User ManuaI DOM-WLE-SFQ Rubber-jacketed cabIe, 7.5mm ± 0.1mm OD, 450 ± 10mm Iength OUTPUT1-2 OUTPUT3-4 195mm 200mm 80mm V-(BIack) 64mm Rubber-jacketed cabIe, 10mm ± 0.1mm OD, 445 ± 10mm Iength Reset: Within 10 seconds, repeat powering on 5 times. After the Iight strip fIashes 10 times, power it on again. If the Iight strip does not Iight up, the reset is successfuI. OUTPUT1-2 IO18 (Black) V+ (Brown) IO17 (YeIIow+Green) GND (BIue) IO16 (Black) V+ (Brown) IO2 (YeIIow+Green) GND (BIue) OUTPUT3-4 DOMRAEM ModeI NO.:DOM-WLE-SFQ Input VoItage:DC 5V-48V Output Curent/ChanneI:10A Max TotaI Output Current:16A Max Working Tamperature:-20-45 °C ESP32 WLED 4CH IP65 Waterproof LED ControIIer with Mic Mic INPUT DC 5V-48V V- (BIack) V+ (Red) 25A/58V BIade mini Fuse Made in china ROHS Instuction is here Outputs 4 Reset: Within 10 seconds, repeat powering on 5 times. After the Iight strip fIashes 10 times, power it on again. If the Iight strip does not Iight up, the reset is successfuI. OUTPUT1-2 IO18 (Black) V+ (Brown) IO17 (YeIIow+Green) GND (BIue) IO16 (Black) V+ (Brown) IO2 (YeIIow+Green) GND (BIue) OUTPUT3-4 DOMRAEM ModeI NO.:DOM-WLE-SFQ Input VoItage:DC 5V-48V Output Curent/ChanneI:10A Max TotaI Output Current:16A Max Working Tamperature:-20-45 °C ESP32 WLED 4CH IP65 Waterproof LED ControIIer with Mic Mic INPUT DC 5V-48V V- (BIack) V+ (Red) 25A/58V BIade mini Fuse Made in china ROHS Instuction is here Outputs 4 Refer to the wiring diagram This product does not incIude waterproof connectors and Iight strips; it is onIy for reference as a wiring diagram in the instruction manuaI. This product supports a wide range of addressabIe LED strips, incIuding but not Iimited to: WS2811、WS2811F、WS2812、WS2812B、WS2813、WS2814、WS2814A、WS2815、 WS2805、SK6812、SK19703、SK16703、SM16703SP3、FL19038、FW1935、TM1814,etc. DOM-WLE-SFQ V-(BIack) V+(Red) 2-core waterproof connector Input VoItage:DC 5V-48V 4-core waterproof connector AddressabIe waterproof LED stripAddressabIe waterproof LED strip AddressabIe waterproof LED stripAddressabIe waterproof LED strip NOTE: When instaIIing the controIIer, pIease fuIIy insert the“cabIe sheaths”of the input and output wires into the waterproof connectors or the interior of the waterproof box. Otherwise, it wiII cause permanent damage to the controIIer. InstaIIation must be carried out with reference to the wiring diagram. Brown wire: V+ (Positive power suppIy Strip VCC) BIue wire: GND (Ground/Negative) YeIIow+green wire: IO2 (Data signaI Iine) Black wire: IO16 (Data signaI Iine) Brown wire: V+ (Positive power suppIy Strip VCC)BIue…
Text truncated - open the document above for the full version.
DOMRAEM Co., Ltd Covered Equipment Certification Attestation Letter 7/3/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BOMS-DOMWLESFQ DOMRAEM Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. DOMRAEM Co., Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. DOMRAEM Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). <Signature>: Name: Jack Bu Title: Manager Company: DOMRAEM Co., Ltd Date: 7/3/2026
DOMRAEM Co., Ltd * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 7/3/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BOMS-DOMWLESFQ FRN of applicant: 0036890812 Per section 2.911(d)(7) of the FCC rules, [DOMRAEM Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Herland International Trading Inc FCC Registration Number (FRN): 0036324101 Physical U.S. Company Address: 1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 Contact Person: Jianfeng Gao Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Jack bu Title: Manager Company Name: DOMRAEM Co., Ltd Date: 7/3/2026 Agent Signed (if different from Applicant): Signed: Printed name: Jianfeng Gao Title: Manager Company Name: Herland International Trading Inc Date: 7/3/2026
DOMRAEM Co., Ltd 2026-06-30 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen DL Testing Technology Co., Ltd.(101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China)to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with DOMRAEM Co., Ltd(Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China) <Signature>: Name: Jack Bu Title: Manager Company: DOMRAEM Co., Ltd
DOMRAEM Co., Ltd 2026-06-25 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, <Signature>: Name: Jack Bu Title: Manager Company: DOMRAEM Co., Ltd
DOMRAEM Co., Ltd 2026-06-25 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BOMS-DOMWLESFQ Product Name: LED Strip Controller Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name: Jack Bu Title: Manager Company: DOMRAEM Co., Ltd
DOMRAEM Co., Ltd FCC ID: 2BOMS-DOMWLESFQ Product Similarity Declaration Applicant: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Manufacturer: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Product Name: LED Strip Controller Trade Mark: Model Number: DOM-WLE-SFQ, DOM-WLE-SFM, DOM-WLE-SF, DOM-WLE-SFC, DOM- WLE-SFD, DOM-WLE-SFE, DOM-WLE-SFG, DOM-WLE-SFK, DOM-ETH- 836P, DOM-ETH-832P, DOM-ETH-834P, DOM-WLE-816DM, DOM-WLE- 812DM, DOM-WLE-814DM, DOM-WLE-312P, DOM-WLE-316P, DOM- WLE-318P, DOM-WLE-312DM, DOM-WLE-316DM, DOM-WLE-318DM We (DOMRAEM Co., Ltd) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), All models are the same as the samples except for the model name and appearance color. <Signature>: Name: Jack Bu Title: Manager Company: DOMRAEM Co., Ltd
Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※
Size:28*12mm M/N: DOM-WLE-SFQ FCCID: 2BOMS-DOMWLESFQ Label location
Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) ANT Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※
FCC ID: 2BOMS-DOMWLESFQ RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in KDB 447498 D01 V06 and 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. EIRP=EMeas+20log(dMeas)-104.7 EIRP is the equivalent isotropically radiated power, in dBm EMeas is the field strength of the emission at the measurement distance, in dBμV/m dMeas is the measurement distance, in m Test Result of RF Exposure Evaluation WiFi mode Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2412 15.96 39.4 0.02 1.0 PASS Remark: antenna gain=3.28dBi
Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 42 FCC ID: 2BOMS-DOMWLESFQ Applicant: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Manufacturer: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Product Name: LED Strip Controller Trade Mark: Model Number: DOM-WLE-SFQ, DOM-WLE-SFM, DOM-WLE-SF, DOM-WLE-SFC, DOM-WLE-SFD, DOM-WLE-SFE, DOM-WLE-SFG, DOM-WLE-SFK, DOM-ETH-836P, DOM-ETH-832P, DOM-ETH-834P, DOM-WLE-816DM, DOM-WLE-812DM, DOM-WLE-814DM, DOM-WLE-312P, DOM-WLE-316P, DOM-WLE-318P, DOM-WLE-312DM, DOM-WLE-316DM, DOM-WLE-318DM Date of Receipt: Jun. 10, 2026 Test Date: Jun. 10, 2026 - Jun. 25, 2026 Date of Report: Jun. 25, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10:2020+Cor.1:2023 Test Result: Pass Report Number: DLE-260610031R Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 42 Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT b 2412 Ant1 100 0 0 NVNT b 2437 Ant1 100 0 0 NVNT b 2462 Ant1 100 0 500 NVNT g 2412 Ant1 100 0 0 NVNT g 2437 Ant1 100 0 0 NVNT g 2462 Ant1 100 0 0 NVNT n20 2412 Ant1 100 0 0 NVNT n20 2437 Ant1 100 0 0 NVNT n20 2462 Ant1 100 0 0 NVNT n40 2422 Ant1 100 0 0 NVNT n40 2437 Ant1 100 0 0 NVNT n40 2452 Ant1 100 0 0 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 42 Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 Duty Cycle NVNT b 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 42 Duty Cycle NVNT g 2412MHz Ant1 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 42 Duty Cycle NVNT n20 2412MHz Ant1 Duty Cycle NVNT n20 2437MHz Ant1 Duty Cycle NVNT n20 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 6 of 42 Duty Cycle NVNT n40 2422MHz Ant1 Duty Cycle NVNT n40 2437MHz Ant1 Duty Cycle NVNT n40 2452MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 7 of 42 Maximum Average Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Conducted Power (dBm) Limit Conducted(dBm) Verdict NVNT b 2412 Ant1 13.73 0 13.73 30 Pass NVNT b 2437 Ant1 11.87 0 11.87 30 Pass NVNT b 2462 Ant1 10.17 0 10.17 30 Pass NVNT g 2412 Ant1 15.96 0 15.96 30 Pass NVNT g 2437 Ant1 15.52 0 15.52 30 Pass NVNT g 2462 Ant1 15.41 0 15.41 30 Pass NVNT n20 2412 Ant1 15.42 0 15.42 30 Pass NVNT n20 2437 Ant1 15.34 0 15.34 30 Pass NVNT n20 2462 Ant1 15.3 0 15.3 30 Pass NVNT n40 2422 Ant1 14.96 0 14.96 30 Pass NVNT n40 2437 Ant1 15.19 0 15.19 30 Pass NVNT n40 2452 Ant1 14.77 0 14.77 30 Pass Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 8 of 42 Average Power NVNT b 2412MHz Ant1 Average Power NVNT b 2437MHz Ant1 Average Power NVNT b 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 9 of 42 Average Power NVNT g 2412MHz Ant1 Average Power NVNT g 2437MHz Ant1 Average Power NVNT g 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 10 of 42 Average Power NVNT n20 2412MHz Ant1 Average Power NVNT n20 2437MHz Ant1 Average Power NVNT n20 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 11 of 42 Average Power NVNT n40 2422MHz Ant1 Average Power NVNT n40 2437MHz Ant1 Average Power NVNT n40 2452MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 12 of 42 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 8.857 0.5 Pass NVNT b 2437 Ant1 8.847 0.5 Pass NVNT b 2462 Ant1 9.051 0.5 Pass NVNT g 2412 Ant1 16.34 0.5 Pass NVNT g 2437 Ant1 16.31 0.5 Pass NVNT g 2462 Ant1 16.35 0.5 Pass NVNT n20 2412 Ant1 17.26 0.5 Pass NVNT n20 2437 Ant1 17.31 0.5 Pass NVNT n20 2462 Ant1 17.2 0.5 Pass NVNT n40 2422 Ant1 33.55 0.5 Pass NVNT n40 2437 Ant1 33.63 0.5 Pass NVNT n40 2452 Ant1 33.49 0.5 Pass Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 13 of 42 -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 -6dB Bandwidth NVNT b 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 14 of 42 -6dB Bandwidth NVNT g 2412MHz Ant1 -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 15 of 42 -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 -6dB Bandwidth NVNT n20 2462MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 16 of 42 -6dB Bandwidth NVNT n40 2422MHz Ant1 -6dB Bandwidth NVNT n40 2437MHz Ant1 -6dB Bandwidth NVNT n40 2452MHz Ant1 Report Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 17 of 42 Occupied Channel Bandwidth Condition Mode Frequency (MHz) Antenna 99% OBW (MHz) NVNT b 2412 Ant1 13.086 NVNT b 2437 Ant1 13.079 NVNT b 2462 Ant1 13.003 NVNT g 2412 Ant1 16.429 NVNT g 2437 Ant1 16.423 NVNT g 2462 Ant1 16.405 NVNT n20 2412 Ant1 17.376 NVNT n20 2437 Ant1 17.393 NVNT n20 2462 Ant1 17.39 NVNT n40 2422 Ant1 34.839 NVNT n40 2437 Ant1 34.913 NVNT n40 24…
Text truncated - open the document above for the full version.
Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260610031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 32 FCC Part 15C Test Report FCC ID: 2BOMS-DOMWLESFQ Applicant: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Manufacturer: DOMRAEM Co., Ltd Address: Room 706, Building 2, Xincanghai No. 18-1, Xiusha Road, Shatian Community Kengzi Subdistrict, Pingshan District Shenzhen, Guangdong, China Product Name: LED Strip Controller Trade Mark: Model Number: DOM-WLE-SFQ, DOM-WLE-SFM, DOM-WLE-SF, DOM-WLE-SFC, DOM-WLE-SFD, DOM-WLE-SFE, DOM-WLE-SFG, DOM-WLE-SFK, DOM-ETH-836P, DOM-ETH-832P, DOM-ETH-834P, DOM-WLE-816DM, DOM-WLE-812DM, DOM-WLE-814DM, DOM-WLE-312P, DOM-WLE-316P, DOM-WLE-318P, DOM-WLE-312DM, DOM-WLE-316DM, DOM-WLE-318DM Date of Receipt: Jun. 10, 2026 Test Date: Jun. 10, 2026 - Jun. 25, 2026 Date of Report: Jun. 25, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10:2020+Cor.1:2023 Test Result: Pass Report Number: DLE-260610031R Prepared (Test Engineer): Alisa Song Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260610031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 32 Table of Contents Page 1. . SUMMARY OF TEST RESULTS 4 1.1. MEASUREMENT UNCERTAINTY 4 2. . GENERAL INFORMATION 5 2.1. GENERAL DESCRIPTION OF EUT 5 2.2. DESCRIPTION OF TEST MODES 6 2.3. BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4. DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 7 2.5. TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 7 2.6. EQUIPMENTS LIST FOR ALL TEST ITEMS 8 3. . EMC EMISSION TEST 9 3.1. CONDUCTED EMISSION MEASUREMENT 9 3.1.1. POWER LINE CONDUCTED EMISSION LIMITS 9 3.1.2. TEST PROCEDURE 9 3.1.3. DEVIATION FROM TEST STANDARD 9 3.1.4. TEST SETUP 10 3.1.5. EUT OPERATING CONDITIONS 10 3.1.6. TEST RESULTS 10 3.2. RADIATED EMISSION MEASUREMENT 11 3.2.1. RADIATED EMISSION LIMITS 11 3.2.2. TEST PROCEDURE 12 3.2.3. DEVIATION FROM TEST STANDARD 12 3.2.4. TEST SETUP 12 3.2.5. EUT OPERATING CONDITIONS 13 3.2.6. TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 14 3.2.7. TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 15 3.2.8. TEST RESULTS (1GHZ~25GHZ) 17 3.3 RADIATED BAND EMISSION MEASUREMENT 21 3.3.1 TEST REQUIREMENT: 21 3.3.2 TEST PROCEDURE 21 3.3.3 DEVIATION FROM TEST STANDARD 21 3.3.4 TEST SETUP 22 3.3.5 EUT OPERATING CONDITIONS 22 3.4 CONDUCTED BAND EDGE EMISSION&CONDUCTED SPURIOUS EMISSIONS MEASUREMENT 27 3.4.1 APPLICABLE STANDARD 27 3.4.2 TEST PROCEDURE 27 3.4.3 DEVIATION FROM STANDARD 27 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260610031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 32 Table of Contents Page 3.4.4 TEST SETUP 27 3.4.5 EUT OPERATION CONDITIONS 27 3.4.6 TEST RESULTS 27 4. . AVERAGE OUTPUT POWER 28 4.1. APPLIED PROCEDURES / LIMIT 28 4.1.1. TEST PROCEDURE 28 4.1.2. DEVIATION FROM STANDARD 28 4.1.3. TEST SETUP 28 4.1.4. EUT OPERATION CONDITIONS 28 4.1.5. TEST RESULTS 28 5. . POWER SPECTRAL DENSITY TEST 29 5.1. APPLIED PROCEDURES / LIMIT 29 5.1.1. TEST PROCEDURE 29 5.1.2. DEVIATION FROM STANDARD 29 5.1.3. TEST SETUP 29 5.1.4. EUT OPERATION CONDITIONS 29 5.1.5. TEST RESULTS 29 6. . 6DB BANDWIDTH TEST 30 6.1. APPLIED PROCEDURES / LIMIT 30 6.1.1. TEST PROCEDURE 30 6.1.2. DEVIATION FROM STANDARD 30 6.1.3. TEST SETUP 30 6.1.4. EUT OPERATION CONDITIONS 30 6.1.5. TEST RESULTS 30 7. . DUTY CYCLE TEST SIGNAL 31 7.1. APPLIED PROCEDURES / LIMIT 31 7.1.1. TEST PROCEDURE 31 7.1.2. DEVIATION FROM STANDARD 31 7.1.3. TEST SETUP 31 7.1.4. EUT OPERATION CONDITIONS 31 7.1.5. TEST RESULTS 31 8. . ANTENNA REQUIREMENT 32 8.1. STANDARD REQUIREMENT 32 8.2. EUT ANTENNA 32 9. . TEST SEUUP PHOTO 32 10. . EUT PHOTO 32 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260610031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 32 1.. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.205, 15.209, 15.247(d) Radiated Spurious Emission PASS 15.209, 15.205 Band Edge Emission PASS 15.247(d) Conducted Spurious Emissions PASS 15.247(b) Average Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(e) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1. MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 6dB Bandwidth ±0.2% 9 Power Spectral Density ±2.45dBm Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260610031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Em…
Text truncated - open the document above for the full version.
Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. Antenna OTA Test Report For ESP-ANT-A Customer 深圳四博智联科技有限公司 Demo ESP32-32E Band 2.4G Color 黑色 PRS PN Version V1.0 Issued by Jason Checked by Mem Confirmed by Zhang Date 2022.03.18 一.TEST INSTRUMENTATION CHAMBER SATIMO Chamber Wireless Networking Test Set Agilent E5071C NETWORK ANALYZER Agilent 8753D TEMPERATURE 20±3°C HUMIDITY 50±20%rh GROUND RESISTANCE <0.5R Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. ESP32-32E WiFi Module Antenna Dimension for ESP32-32E Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. 二. Test Results 2.1 Gain and Efficiency Test Freq Efficiency Gain Note Item (MHz) (%) (dBi) Gain 2400 71.32 2.72 Vertical 30° 2412 70.68 3.21 2417 76.51 2.88 2422 77.78 2.67 2427 80.76 2.89 2432 80.11 2.80 2437 75.32 2.64 2442 75.23 2.93 2447 72.99 2.78 2452 70.01 3.12 2457 72.34 3.13 2462 71.32 3.28 2467 72.33 3.24 2472 75.67 3.33 2477 72.12 3.42 2482 80.23 3.57 2500 79.65 3.22 2.2 VSWR (Voltage Standing Wave Ration) Percsson Communication Equipment Co., Ltd This test report belongs to PERCSSON COMMUNICATION EQUIPMENT CO.LTD. and related clients to file,please keeping it propely,without our company and related clients allowed,anybody has no rights to reval it to public. Frequency(MHz) 2412 2437 2463 2484 VSWR 1.31 1.17 1.16 1.29 2.3 Antenna S11 Frequency(MHz) 2412 2437 2463 2484 S11 (dB) -17.01 -21.65 -22…
Text truncated - open the document above for the full version.
1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 · Diamond Bar, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 39.40 mW |