FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Aiwotai Technology (Shenzhen) Co., Ltd./
  3. 2BOPX-MGI9

2BOPX-MGI9MINI PC

Aiwotai Technology (Shenzhen) Co., Ltd.
MINI PC - FCC ID 2BOPX-MGI9 - Aiwotai Technology (Shenzhen) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 27, 2025
Application Purpose
Original Equipment
Equipment Note
MINI PC
Frequency Range
2402.00000000 - 2480.00000000
Company
Aiwotai Technology (Shenzhen) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Aiwotai Technology (Shenzhen) Co., Ltd. p 1 / 2 63_Compliance proof covered list - November 11, 2025 --- Covered List Software Incapability 1 --- Device (model name): MINI PC Grantee: Aiwotai Technology (Shenzhen) Co., Ltd. FCC ID: 2BOPX-MGI9 Device features: Operating System (as applicable): N/A Storage Capacity (hard drive or other permanent memory storage): N/A Is installation of third-party software possible? YES NO Does the device have an internet connection? YES NO Can the device connect to a PC? YES NO Chipset/module information: Chipset / module part number: Memory size (MB) WCSAX101 N/A Minimum system requirements Kaspersky as of December 3, 2024 Android Memory: 120 MB Disc space: unknown Processor speed: unknown MacOS Memory: 2000 MB Disc space: 2200 MHz Processor speed: unknown Windows Memory: 1000 MB Disc space: 1000 MB Processor speed: 1 GHz Linux Memory: 1000 MB Disc space: 1000 MHz Processor speed: 1 GHz Based on the review of the above factsheet(s) and device features, the device cannot support installation of any cybersecurity or anti-virus software on the covered list. potentially can operate with any cybersecurity or anti-virus software on the covered list – additional 3 rd party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – page 2 of this document applies. Signature: Name: Holli Lee Title/Position: Manager 1 List of minimum requirements to implement covered list software – if the EUT does not have capability to install Kaspersky under the given configuration. Page 2 must also be handed in. Note: If the device is capable of running Kaspersky software, at least one document must be provided from a third party showing that the Kaspersky software is not present on the device. This could include the results of a software scan, a screen capture of the device software register or other objective evidence that proves the Kaspersky software is not on the device. Please follow options listed on page 2. Aiwotai Technology (Shenzhen) Co., Ltd. p 2 / 2 63_Compliance proof covered list - - Options to provide of compliance with covered list software requirements - Please fill in as applicable and provide additional proof as requested: 1 Has the client signed an attestation stating the device is incapable of running the Kaspersky software (page 1)? * YES – no more proof needed – 2-5 do not apply > N/A ** NO – more proof must be provided (item 2-5 must be answered) YES* NO** 2 Did the test lab or other 3rd party other than the certification body and applicant provide a list of software installed on the device and is there no evidence of Kaspersky software being installed? ***YES – please: YES*** NO N/A Insert File Name: Insert 3 rd Party Name: 3 Have the results of a software scan been provided showing that Kaspersky software is not installed on the device? ***YES – please: YES*** NO N/A Insert File Name: Insert 3 rd Party Name: 4 Has any other objective evidence that Kaspersky software is not installed on the device been provided? ***YES – please: YES*** NO N/A Insert File Name: Insert 3 rd Party Name: 5 Has at least one of the above items been shown as a YES? **** NO – applicant failed to provide sufficient proof – application filing is rejected. YES NO**** Note: Files containing confidential operational details can be kept long-term confidential on applicant’s request.

Attestation Statements

Aiwotai Technology (Shenzhen) Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [November 12, 2025] U.S. Agent Designation [Aiwotai Technology (Shenzhen) Co., Ltd.] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BOPX-MGI9 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [Aiwotai Technology (Shenzhen) Co., Ltd.]. [Aiwotai Technology (Shenzhen) Co., Ltd.] with the FRN [0036908275] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [Holli Lee] [Huiying Fan] [Manager] [Director] [Aiwotai Technology (Shenzhen) Co., Ltd.] [GLOCERTS TECHNOLOGY INC]

Attestation Statements

(Aiwotai Technology (Shenzhen) Co., Ltd.) (November 11, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BOPX-MGI9) [Aiwotai Technology (Shenzhen) Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Holli Lee (Aiwotai Technology (Shenzhen) Co., Ltd.) (November 11, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BOPX-MGI9) [Aiwotai Technology (Shenzhen) Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Holli Lee

Cover Letter(s)

Aiwotai Technology (Shenzhen) Co., Ltd. Model Difference Data: November 11, 2025 Product description: Mini PC Model name: MGi9, MF01, MF02, MF03 Trade Name: AWOW FCC ID: 2BOPX-MGI9 All the model are the same circuit and RF module, only the model name are different. Regards Sincerely Client’s signature: Client’s name / title: Holli Lee (Manager) Contact information / address: A602-603, Jinfulai Building, Dabao Road, Xin'an Street, Baoan District Guangdong Shenzhen

Cover Letter(s)

Aiwotai Technology (Shenzhen) Co., Ltd. ( November 11, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Mini PC / M Gi9, MF01, MF02, MF03 / FCC ID: 2 BOPX-MGI9) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☒ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Holli Lee Title: Manager

Cover Letter(s)

Aiwotai Technology (Shenzhen) Co., Ltd. (November 11, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen MinFan Electronic Commerce Co., LTD) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Holli Lee Title: Manager

External Photos

Aiwotai Technology (Shenzhen) Co., Ltd. External Photos Model: MGi9 Aiwotai Technology (Shenzhen) Co., Ltd. Aiwotai Technology (Shenzhen) Co., Ltd. Aiwotai Technology (Shenzhen) Co., Ltd. Aiwotai Technology (Shenzhen) Co., Ltd. Aiwotai Technology (Shenzhen) Co., Ltd.

ID Label/Location Info

FCC ID LABEL: Label Location: MINI PC Model:MGi9 FCC ID:2BOPX-MGI9 Aiwotai Technology (Shenzhen) Co., Ltd.

RF Exposure Info

FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2BOPX-MGI9 Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength € (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength € (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result BLE GFSK& MCH 2±1 3 1.9953 1.4488 (1.61dBi) 0.0006 1 Pass EDR 8DPSK& MCH 3±1 4 2.5119 1.4488 (1.61dBi) 0.0007 1 Pass 2.4GWIFI ANT1 802.11ax4 0&2437 14±1 15 31.6228 1.4488 (1.61dBi) 0.0091 1 Pass 2.4GWIFI ANT1 802.11g& 2437 14±1 15 31.6228 2.0989 (3.22dBi) 0.0132 1 Pass 5.2GWIFI ANT1 802.11a20 &5240 14±1 15 31.6228 3.1046 (4.92dBi) 0.0195 1 Pass 5.2GWIFI ANT2 802.11ac 40&5230 14±1 15 31.6228 3.1046 (4.92dBi) 0.0195 1 Pass For the Max simultaneous transmission MPE: When a number of sources at different frequencies, and/or broadband sources, contribute to the total exposure, it becomes necessary to weigh each contribution relative to the MPE in accordance with the provisions of Table (A) and Table (B). To comply with the MPE, the fraction of the MPE in terms of E2, H2 (or power density) incurred within each frequency interval should be determined and the sum of all such fractions should not exceed unity. In order to ensure compliance with the MPE for a controlled environment, the sum of the ratios of the power density to the corresponding MPE should not exceed unity. That is Techn ology Tune up Produce power(dBm) Maximum Tune- up(dBm) Antenna Gain (numeric) Power Density(S)( mW/cm2) MPE Limit (mW/c m2) Σ MPE Ratio Σ MPE Ratio Limit Result ANT 1 ANT 2 ANT 1 ANT 2 ANT1 ANT2 ANT 1 ANT 2 2.4G WIFI MIMO 14 ±1 14 ±1 15 15 1.4488 (1.61 dBi) 2.0989 (3.22 dBi) 0.00 91 0.01 32 1 0.02 23 1 Pass Techn ology Tune up Produce power(dBm) Maximum Tune- up(dBm) Antenna Gain (numeric) Power Density(S)( mW/cm2) MPE Limit (mW/c m2) Σ MPE Ratio Σ MPE Ratio Limit Result ANT 1 ANT 2 ANT 1 ANT 2 ANT1 ANT2 ANT 1 ANT 2 5GWI FI MIMO 14 ±1 14 ±1 15 15 3.1046 (4.92 dBi) 3.1046 (4.92 dBi) 0.01 95 0.01 95 1 0.39 1 Pass

Test Report

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 56 TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Mini PC FCC ID: 2BOPX-MGI9 Trademark: AWOW Model Number: MGi9, MF01, MF02, MF03 Prepared For: Aiwotai Technology (Shenzhen) Co., Ltd. Address: A602-603, Jinfulai Building, Dabao Road, Xin'an Street, Baoan District Guangdong Shenzhen Manufacturer: Aiwotai Technology (Shenzhen) Co., Ltd. Address: A602-603, Jinfulai Building, Dabao Road, Xin'an Street, Baoan District Guangdong Shenzhen Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Oct. 15, 2025 Sample tested Date: Oct. 15, 2025 to Oct. 24, 2025 Issue Date: Oct. 24, 2025 Report No.: CTB25101515201RF02 Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2020 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25101515201RF02 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 56 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ........................................................................................................................................ 4 2. TEST SUMMARY ........................................................................................................................... 5 3. MEASUREMENT UNCERTAINTY ................................................................................................. 6 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................ 7 4.1 Product Information .......................................................................................................................... 7 4.2 Test Setup Configuration .................................................................................................................. 7 4.3 Support Equipment........................................................................................................................... 7 4.4 Channel List ..................................................................................................................................... 8 4.5 Test Mode ........................................................................................................................................ 8 4.6 Test Environment ............................................................................................................................. 8 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................................................... 9 5.1 Test Facility ...................................................................................................................................... 9 5.2 Test Instrument Used ....................................................................................................................... 9 6. AC POWER LINE CONDUCTED EMISSION ................................................................................ 12 6.1 Block Diagram Of Test Setup ......................................................................................................... 12 6.2 Limit ................................................................................................................................................ 12 6.3 Test procedure ............................................................................................................................... 12 6.4 Test Result ..................................................................................................................................... 14 7. RADIATED SPURIOUS EMISSION ............................................................................................. 16 7.1 Block Diagram Of Test Setup ......................................................................................................... 16 7.2 Limit ................................................................................................................................................ 16 7.3 Test procedure ............................................................................................................................... 17 7.4 Test Result ..................................................................................................................................... 18 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ............................................... 27 8.1 Block Diagram Of Test Setup ......................................................................................................... 27 8.2 Limit ................................................................................................................................................ 27 8.3 Test procedure ............................................................................................................................... 27 8.4 Test Result ..................................................................................................................................... 28 9. CONDUCTED PEAK OUTPUT POWER ...................................................................................... 35 9.1 Block Diagram Of Test …

Text truncated - open the document above for the full version.

Test Setup Photos

Aiwotai Technology (Shenzhen) Co., Ltd. Model: MGi9 Radiated Emission Below 1G Above 1G Aiwotai Technology (Shenzhen) Co., Ltd. Conducted emissions

Contact Information

Applicant

Holli Lee
[email protected]Fax: 18777973672

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.11 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.