FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Hansong Tuojiang Technology Co., Ltd/
  3. 2BPI3-HSTW-9

2BPI3-HSTW-9Towel warmer

Guangzhou Hansong Tuojiang Technology Co., Ltd
Towel warmer - FCC ID 2BPI3-HSTW-9 - Guangzhou Hansong Tuojiang Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 19, 2026
Application Purpose
Original Equipment
Equipment Note
Towel warmer
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangzhou Hansong Tuojiang Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HSTW-� Luxury Towel Warmer Contents Important Safety Instructions FCC Information Location of Part & Controls Using The Towel & Blanket Warmer Product Specifications Function overview Tips for Best Results Care and Maintenance �� �� �� �� �� �� �� �� CAUTION TO REDUCE THE RISK OF SERIOUS INJURY, PLEASE NOTE : THIS IS NOT A TOY. DO NOT ALLOW CHILDREN TO OPERATE OR PLAY NEAR THE TOWEL & BLANKET WARMER. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE The lightning flash with arrow-head symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the unit's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the unit. WARNING To reduce risk of fire,electric shock, or serious injury to persons when using the appliance, follow basic precautions including the Read all instructions before using the appliance. ·Always unplug the unit from the electrical outlet immediately after use. ·Do not use appliance for anything other than its intended purpose. ·Do not place or store the unit where it can fall or be pulled into a tub or sink. ·Do not place in or drop into water or other liquid. ·Do not reach for a unit that has fallen into water. Unplug it immediately. ·Care should be taken so that objects do not fall into and/or liquids are not spilled onto the unit. ·This unit should never be left unattended when plugged in. ·Close supervision is necessary when this unit is used near children or disabled persons. Important Safety Instructions ALL SAFETY AND OPERATING INSTRUCTIONS SHOULD BE READ AND FOLLOWED BEFORE OPERATING THE UNIT. SAVE THESE INSTRUCTIONS. ·FOR HOUSEHOLD USE ONLY ·FOR ADULT USE ONLY ·FOR DRY FABRIC ITEMS ONLY �� ·Use this unit for its intended purpose as described in this manual. ·Never operate this unit if it has a damaged cord or plug, if it is not working properly, or if it has been dropped, damaged, or dropped in water. ·Keep cords away from heated surfaces. Do not wrap the cord around the appliance or let it hang over the edge of a table or counter. ·Do not use outdoors. ·Do not alter the safety plug or use an extension cord with this device. ·Do not operate with a voltage converter. ·Do not touch hot surfaces. ·Do not use accessory attachments not recommended by the manufacturer as this may case injuries. FCC Information CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part �� of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This unit generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception(which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna. ·Increase the separation between the equipment and receiver. · Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. ·Consult the dealer or an experienced radio/TV technician for help. �.This device may not cause harmful interference. �.This device must accept any interference received including interference that may cause undesired operation. This device complies with Part �� of the FCC Rules. Operation is subject to the following two conditions: �� PARTS AND CONTROLS Power control: Touch to turn heating on/off�. �. �. �. �. �. �. �. �. ��. Timer control: Touch to set heating time Light control: ·Short press to turn ambient lighting on/off ·long press to change lighting mode Heating status indication light Bluetooth speaker Lid Child safety lock Fragrance disc holder RGB light Bluetooth: ·Short press to turn Bluetooth speaker on/off �� � � � � �� � � � � � USING THE TOWEL WARMER The Towel Warmer will warm two bath towels measuring approximately ��" x ��" . �.Place the Towel Warmer on a dry, level, hard surface. �.Insert the power cord into an electrical outlet. �.Open the Lid and remove any packaging contents. �. Place your dry towel(s) inside. Replace the lid. �. Method �: After powering on, touch the power button. The heating time will flash for � seconds, and then heating will begin. The default time is �� minutes. �.After powering on, press the Bluetooth button to connect your phone to the HSTW-�-BT via Bluetooth. Once connected, you can play music; adjust the volume according to your phone's settings. Press the Bluetooth button again to turn off Bluetooth after playback. �.After powering on, press the RGB lighting button to activate the white night light mode. Press and hold for � second to activate the carousel mode. Press briefly for turn off the lights. �. Method �: After powering on, touch the power button, then touch the timer button to select the heating time. Finishing the selecting, the heating time flashes for � seconds and then starts heating. �. When the heating cycle ends or the unit is powered off, the heating status light will turn off once the temperature drops below ���°F. This device complies with Part �� of the FCC Rules. PRODUCT SPECIF…

Text truncated - open the document above for the full version.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HerlandInternationalTradingInc FRN:0036324101 ContactName:JianfengGao Address:1370ValleyVistaDrSte200DiamondBarCalifornia91765-3921 TelephoneNo:001-909-772-1888 Email:[email protected] Applicant: Companyname:GuangzhouHansongTuojiangTechnologyCo.,Ltd ProductDescription:Towelwarmer Granteecode:2BPI3 FCCID:2BPI3-HSTW-9 FRN:0037043270 ContactName:AnnxiXie Address:No.5LianchengRoad,TanbuTown,HuaduDistrict,GuangzhouCity,Guangdong ProvinceChina TelephoneNo:18054299659 Email:[email protected] [GuangzhouHansongTuojiangTechnologyCo.,Ltd]certifiesthat,asofthe dateofthisfilingoftheapplicationwiththeTCB,[HerlandInternationalTrading Inc]isourdesignatedUSagentforserviceofprocessfortheabovereferenced FCCID.[GuangzhouHansongTuojiangTechnologyCo.,Ltd]acceptsto maintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanycommissionrelated proceedinginvolvingequipment.[HerlandInternationalTradingInc]accepts,as ofthedateofthefilingoftheapplication,theobligationofthedesignatedUS agentforserviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2026/08/13 Applicant’sName:AnnxiXieUSAgent’sName:JianfengGao Title:SalesmanagerTitle:Manager SignatureSignature

Attestation Statements

AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1 GuangzhouHansongTuojiangTechnologyCo.,Ltd TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:GuangzhouHansongTuojiangTechnologyCo.,Ltd Granteecode:2BPI3 FCCID:2BPI3-HSTW-9 FRN:0037043270 ContactName:AnnxiXie Address:No.5LianchengRoad,TanbuTown,HuaduDistrict,GuangzhouCity, GuangdongProvinceChina TelephoneNo:18054299659 FaxNo:0755-26509195 Email:[email protected] i.[GuangzhouHansongTuojiangTechnologyCo.,Ltd](“theapplicant”) certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.[GuangzhouHansongTuojiangTechnologyCo.,Ltd](“theapplicant”) certifiesthat,asofthedateofthefilingoftheapplication,theapplicant[is not](asaspecificallynamedentityoranyofitssubsidiariesoraffiliates) identifiedontheCoveredListasanentityproducing“covered”equipment. Theapplicantmustsignthiscertification. [GuangzhouHansongTuojiangTechnologyCo.,Ltd](“theapplicant”)certifiesthat, asofthedateofthefilingoftheapplication,theapplicant[isnot]identifiedonthe CoveredListasanentityproducing“covered”equipment. Date:2026/08/13 Applicant’sName:AnnxiXie Title:Salesmanager Signature: TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1

Attestation Statements

GuangzhouHansongTuojiangTechnologyCo.,Ltd Code00018768Ed.1 Item1.Thedeviceisabletoinstallsoftware/programinstallation? ☐ Yes,gotoItem2. ☒No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky cybersecurityoranti-virussoftware. Item2.TechnicalRequirementsforKasperskyCybersecuritySoftware: #GeneralRequirements(ForallDevices)Yes/NoorN/AComments 1Internetconnectionforactivationandupdates(ForallOperating Systems) N/A DeviceTowelwarmer CompanynameGuangzhouHansongTuojiangTechnologyCo., Ltd Granteecode2BPI3 FCCID2BPI3-HSTW-9 FRN0037043270 ContactnameAnnxiXie AddressNo.5LianchengRoad,TanbuTown,Huadu District,GuangzhouCity,GuangdongProvince China Telephonenumber18054299659 [email protected] Chipset/moduleinformationAB5605E OperatingSystem(ifapplicable)N/A StorageCapacity(harddriveorother permanentmemorystorage,ifapplicable) N/A 2 #GeneralRequirements(ForWindowsDevices)Yes/NoorN/AComments 1Storage:1500MBfreespaceontheharddriveN/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/Enterprise Microsoft Windows7Starter/HomeBasic&Premium/Professional/ UltimateSP1orhigher N/A 3Processor:1GHzorhigher(x86orx64)N/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)N/A 5ScreenResolution:Minimumresolutionof1024x768N/A #GeneralRequirements(FormacOSdevices)Yes/NoorN/AComments 1OperatingSystemmacOS®13–14N/A 2Memory(RAM)4GBN/A 3Storage:3455MBfreespaceontheharddriveN/A #GeneralRequirements(ForAndroidDevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:Android™10–14N/A 3ScreenResolution:Minimumresolutionof320x480N/A #GeneralRequirements(foriOSdevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:iOS®17N/A #GeneralRequirements(ForLinuxsystem)Yes/NoorN/AComments 3 1Harddrive:1GBoffreespaceN/A 2CPU:IntelPentium1GHzorhigherN/A 3RAM:1GBN/A 4Minimumsoftwarerequirements: AlmaLinuxOS8orlater; AlterOS7.5orlater; AstraLinuxCommonEdition2.12orlater; CentOS6.7orlater; DebianGNU/Linux10.0orlater; EulerOS2.0orlater; OracleLinux7.3orlater; RedHatEnterpriseLinux6.7orlater; RockyLinux8.5orlater; SUSELinuxEnterpriseServer12.5orlater; Ubuntu12.04orlater; UncomOSHome/Business/Education/Enterprise2.2orlater; ALTLinuxWorkstaton/WorkstationK/Server/Education8or later; ROSALinuxWorkstation/Server12orlater; REDOS7.3andlater; N/A Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingtheinstallationof Kasperskysoftware? ☐ Yes,gotoItem3. ☒No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky software Item3.ConnectivityCapabilities: 4 #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 Afterthereviewofthisitems,thedevice: ☒Cannotsupportinstallationofanycybersecurityoranti-virussoftwareonthecoveredlist. ☐ Potentiallycanoperatewithanycybersecurityoranti-virussoftwareonthecoveredlist–additionalthird- partyproofisprovidedtodemonstratecompliancewithrequirementsasof2.911(d)5(i),(ii)–“Proofof CompliancewithCoveredListSoftwareRequirements”ofthisdocumentapplies Signature:Name:AnnxiXie Date:2026-08-13 1 Thejustificationfieldisusedtojustifywhythesoftwarecannotbereceivedthroughthatinterface.Checktheannexformore indications.

Attestation Statements

TCBCALLpágina1 FileFCCID:2BPI3-HSTW-9 PleaseuploadanexhibitthatexplainshowdoestheTCBverifythenewagentinformation: 1-IstheaddressoftheagentavalidphysicalUSmailingaddress(notaUSpostofficebox,notavirtualmailbox,notP.O.Boxes,notavacantlot,notapublicbuilding, etc.) ○Wehavecheckediftheaddressexistsinarealandpotentialbuilding(Googlemaps)+officialUSregister,afterthisverificationandtheevidencebelowwecan guaranteethefollowing: notaUSpostofficebox notavirtualmailbox notP.O.Boxes notavacantlot notapublicbuilding(note) ►WecheckedtheFCCFRNSearchbasedontheinformationprovidedbythegrantee. Ontheofficialregisterfrom:Search|CaliforniaSecretaryofState TCBCALLpágina2 TCBCALLpágina3 TCBCALLpágina4 TCBCALLpágina5 TCBCALLpágina6 TCBCALLpágina7 TCBCALLpágina8 ►CONCLUSIONbyTCB:TheASOPdefinedandprovidedbygranteeisVALIDandconfirmed.Thereforetheexhibit"C5266091_X23_Ed1_US_Agent_Letter" includedinthefileisok. 2-IstheagentphysicallylocatedatthatvalidUSaddresssuchthattheagentcanbelegallyservedatthataddress? Yes,checkabove 3-Hasthelistedagentclearlyagreedinwritingtoserveastheagentforthegranteeatthataddress? Yes,itisincludedintheexhibit"C5266091_X23_Ed1_US_Agent_Letter" TCBCALLpágina9 >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 GuangzhouHansongTuojiangTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026.08.13 Subject:RequestforConfidentiality FCCID:2BPI3-HSTW-9 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☒☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:AnnxiXie Title:Salesmanager 2026.08.13

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization GuangzhouHansongTuojiangTechnologyCo.,Ltd Company:GuangzhouHansongTuojiangTechnologyCo.,Ltd Address:No.5LianchengRoad,TanbuTown,HuaduDistrict, GuangzhouCity,GuangdongProvinceChina ProductName:Towelwarmer ModelNumber:HSTW-9 FCCIdentifier:2BPI3-HSTW-9 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:AnnxiXieDate:2026.08.13 Title:Manager Signatureofapplicant:

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size: 36*14mm M/N: HSTW-9 FCC ID: 2BPI3-HSTW-9 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※ ANT

RF Exposure Info

FCC ID: 2BPI3-HSTW-9 RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, Conducted output power (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 1.16 1.31 2402 5 0.40 3.0 So a SAR test is not required

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 28 FCC Part 15C Test Report FCC ID: 2BPI3-HSTW-9 Applicant: Guangzhou Hansong Tuojiang Technology Co., Ltd Address: No. 5 Liancheng Road, Tanbu Town, Huadu District, Guangzhou City, Guangdong Province China Manufacturer: Guangzhou Hansong Tuojiang Technology Co., Ltd Address: No. 5 Liancheng Road, Tanbu Town, Huadu District, Guangzhou City, Guangdong Province China Product Name: Towel warmer Trade Mark: N/A Model Number: HSTW-9 Date of Receipt: Jul. 24, 2026 Test Date: Jul. 24, 2026 – Aug. 04, 2026 Date of Report: Aug. 04, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 Test Result: Pass Report Number: DLE-260724007R Prepared (Test Engineer): Ken Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 28 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 6 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 7 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 7 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 8 3 . EMC EMISSION TEST 9 3.1 CONDUCTED EMISSION MEASUREMENT 9 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 9 3.1.2 TEST PROCEDURE 9 3.1.3 DEVIATION FROM TEST STANDARD 9 3.1.4 TEST SETUP 10 3.1.5 EUT OPERATING CONDITIONS 10 3.1.6 TEST RESULTS 10 3.2 RADIATED EMISSION MEASUREMENT 13 3.2.1 RADIATED EMISSION LIMITS 13 3.2.2 TEST PROCEDURE 14 3.2.3 DEVIATION FROM TEST STANDARD 14 3.2.4 TEST SETUP 14 3.2.5 EUT OPERATING CONDITIONS 15 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 16 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 17 3.2.8 TEST RESULTS (1GHZ~25GHZ) 19 3.3 RADIATED BAND EMISSION MEASUREMENT 20 3.3.1 TEST REQUIREMENT: 20 3.3.2 TEST PROCEDURE 20 3.3.3 DEVIATION FROM TEST STANDARD 20 3.3.4 TEST SETUP 21 3.3.5 EUT OPERATING CONDITIONS 21 4 . PEAK OUTPUT POWER 25 4.1 APPLIED PROCEDURES / LIMIT 25 4.1.1 TEST PROCEDURE 25 4.1.2 DEVIATION FROM STANDARD 25 4.1.3 TEST SETUP 25 4.1.4 EUT OPERATION CONDITIONS 25 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 28 Table of Contents Page 4.1.5 TEST RESULTS 25 5 . POWER SPECTRAL DENSITY TEST 26 5.1 APPLIED PROCEDURES / LIMIT 26 5.1.1 TEST PROCEDURE 26 5.1.2 DEVIATION FROM STANDARD 26 5.1.3 TEST SETUP 26 5.1.4 EUT OPERATION CONDITIONS 26 5.1.5 TEST RESULTS 26 6 . 6DB BANDWIDTH TEST 27 6.1 APPLIED PROCEDURES / LIMIT 27 6.1.1 TEST PROCEDURE 27 6.1.2 DEVIATION FROM STANDARD 27 6.1.3 TEST SETUP 27 6.1.4 EUT OPERATION CONDITIONS 27 6.1.5 TEST RESULTS 27 7 . ANTENNA REQUIREMENT 28 7.1 STANDARD REQUIREMENT 28 7.2 EUT ANTENNA 28 8 . TEST SETUP PHOTO 28 9 . EUT PHOTO 28 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 28 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(c) Radiated Spurious Emission PASS 15.205 Band Edge Emission PASS 15.247(b)(1) Peak Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(d) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 6dB Bandwidth ±0.2MHz 9 Power Spectral Density ±0.3dBm Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 28 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: Towel warmer Trademark N/A Model No.: HSTW-9 Model Difference N/A Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2MHz Modulation technology: GFSK Antenna Type: Internal Antenna Antenna gain: 1.49dBi Power supply: 120V~ 60Hz Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2. Channel List Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 00 2402 14 2430 28 2458 01 2404 15 2432 29 2460 02 2406 16 2434 30 2462 03 2408 17 2436 31 2464 04 2410 18 2438 32 2466 05 2412 19 2440 33 2468 06 2414 20 2442 34 2470 07 2416 21 2444 35 2472 08 2418 22 2…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 4 Antenna Describe Antenna Internal Antenna Antenna Gain 1.49dBi Frequency Range 2.4Ghz-2.483Ghz Connector Type Direct Location of measurement (company name) Guangzhou Hansong Tuojiang Technology Co., Ltd Manufacturer: Guangzhou Hansong Tuojiang Technology Co., Ltd Address: 4th Floor, Building 3, No. 70 West Huadu Avenue,Tanbu Town, Huadu District Guangzhou GUANGDONG, China Page 2 of 4 Antenna Photo & Length (mm) Page 3 of 4 1. Characteristics curve 1.1 S11/ SWR Page 4 of 4 2. 2D Radiation characteristics of antenna 2.1 Frequency 2400MHz 2410MHz 2420MHz 2430MHz 2440MHz 2450MHz 2460MHz 2470MHz 2480MHz 2.2 Result Summary Freq.[GHz] Eff.[%] Avg.[dBi] Peak[dBi] 2.4 59.7 -2.24 1.34 2.41 61.8 -2.09 1.43 2.42 59.88 -2.23 1.29 2.43 59.23 -2.27 1.25 2.44 59.98 -2.22 1.32 2.45 61.23 -2.13 1.49 2.46 58.39 -2.34 1.47 2.47 56.82 -2.46 1.4 2.48 55.76 -2.54 1.26

Test Report

Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 16 ANNEX TEST DATA BLE FCC ID: 2BPI3-HSTW-9 Applicant: Guangzhou Hansong Tuojiang Technology Co., Ltd Address: No. 5 Liancheng Road, Tanbu Town, Huadu District, Guangzhou City, Guangdong Province China Manufacturer: Guangzhou Hansong Tuojiang Technology Co., Ltd Address: No. 5 Liancheng Road, Tanbu Town, Huadu District, Guangzhou City, Guangdong Province China Product Name: Towel warmer Trade Mark: N/A Model Number: HSTW-9 Date of Receipt: Jul. 24, 2026 Test Date: Jul. 24, 2026 – Aug. 04, 2026 Date of Report: Aug. 04, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 Test Result: Pass Report Number: DLE-260724007R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 16 1. Bandwidth 1.1 Test Result 1.1.1 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.671 >=0.5 Pass 2440 1 0.670 >=0.5 Pass 2480 1 0.669 >=0.5 Pass Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 16 1.2 Test Graph 1.2.1 6dB BW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 16 1M_HCH_2480MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 16 2. Maximum Conducted Output Power 2.1 Test Result 2.1.1 Power Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 1.16 <=30 Pass 2440 0.26 <=30 Pass 2480 -0.97 <=30 Pass Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 6 of 16 2.2 Test Graph 2.2.1 Power 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 7 of 16 1M_HCH_2480MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 8 of 16 3. Maximum Power Spectral Density 3.1 Test Result 3.1.1 PSD Mode TX Type Frequency (MHz) Maximum PSD (dBm) Verdict ANT1 Limit(dBm/3kHz) 1M SISO 2402 -15.14dBm/3kHz <=8 Pass 2440 -15.86dBm/3kHz <=8 Pass 2480 -17.03dBm/3kHz <=8 Pass Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 9 of 16 3.2 Test Graph 3.2.1 PSD 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 10 of 16 1M_HCH_2480MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 11 of 16 4. Unwanted Emissions In Non-restricted Frequency Bands 4.1 Test Result 4.1.1 Ref Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO 2402 1 1.08 2440 1 0.18 2480 1 -1.07 4.1.2 CSE Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict 1M SISO 2402 1 1.08 -18.92 Pass 2440 1 0.18 -19.82 Pass 2480 1 -1.07 -21.07 Pass Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 12 of 16 4.2 Test Graph 4.2.1 Ref 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 13 of 16 1M_HCH_2480MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 14 of 16 4.2.2 CSE 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 15 of 16 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 16 of 16 1M_HCH_2480MHz_Ant1_NTNV

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. Conducted Emission Photos RF Conducted Test Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Annxi Xie(Sales manager)
[email protected]Fax: 0755-26509195

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]

1370 Valley Vista Dr Ste200 Diamond Bar California · Diamond Bar, California, 91765-3921 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Guangzhou Hansong Tuojiang Technology Co., Ltd

Towel warmer - FCC ID 2BPI3-TJTW-25 - Guangzhou Hansong Tuojiang Technology Co., Ltd
2BPI3-TJTW-25

Towel warmer

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System