Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date: 2026-05-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BPL9-IRBLHC001) [Guangzhou Weijie Trading Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Signature: Name: Guanghua Mi Date: 2026-05-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BPL9-IRBLHC001) [Guangzhou Weijie Trading Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Name: Guanghua Mi
U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: USA MEIHUA TRADING INC Street Address: 5379 Pine Valley Ct City/Province/Zip: Boulder, CO 80301, United States FRN: 0033406166 Contact Name: Harley Quinn Telephone No: (303) 894-2200 Email: [email protected] Signature: Date: May 8, 2026 Signed by (Printed Name/Title): Harley Quinn This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Guangzhou Weijie Trading Co., Ltd. FRN: 0037052578 Grantee Code: 2BPL9 FCC ID: 2BPL9-IRBLHC001 Contact Name: Guanghua Mi Address: B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China Telephone No: 13422449234 Email: [email protected] Signature: Date: 2026-05-08 Signed by (Printed Name/Title): Guanghua Mi
Declaration on model difference We, Guangzhou Weijie Trading Co., Ltd. the undersigned hereby declare that the device's schematics, PCB layout and all other electrical aspects of the device are identical. The only differences are the model no. and chassis heights. Product name: Light-up costume Model name: SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP- LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC FCC ID: 2BPL9-IRBLHC001 Signature: Name: Guanghua Mi Company: Guangzhou Weijie Trading Co., Ltd. Address: B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China
Date: 2026-05-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Light-up costume / SP-LE91HC, SP- LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC, / FCC ID: 2BPL9-IRBLHC001) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagrams, Schematics, Operational Descriptions) required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Signature: Name: Guanghua Mi Company: Guangzhou Weijie Trading Co., Ltd. Address: B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China
Date: 2026-05-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Eurofins Electrical Testing Service (Shenzhen) Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Guanghua Mi Company: Guangzhou Weijie Trading Co., Ltd. Address: B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China TEL: 13422449234
EFGX26040261-IE-02-External Photos 1 / 13 External Photos Model Name: SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC EFGX26040261-IE-02-External Photos 2 / 13 The location of electronic EUT EFGX26040261-IE-02-External Photos 3 / 13 EFGX26040261-IE-02-External Photos 4 / 13 EFGX26040261-IE-02-External Photos 5 / 13 EFGX26040261-IE-02-External Photos 6 / 13 EFGX26040261-IE-02-External Photos 7 / 13 EFGX26040261-IE-02-External Photos 8 / 13 EFGX26040261-IE-02-External Photos 9 / 13 EFGX26040261-IE-02-External Photos 10 / 13 EFGX26040261-IE-02-External Photos 11 / 13 EFGX26040261-IE-02-External Photos 12 / 13 EFGX26040261-IE-02-External Photos 13 / 13
EFGX26040261-IE-02-Internal Photos 1 / 4 Internal Photos Model Name: SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC EFGX26040261-IE-02-Internal Photos 2 / 4 EFGX26040261-IE-02-Internal Photos 3 / 4 EFGX26040261-IE-02-Internal Photos 4 / 4
Radio frequency radiation exposure evaluation: portable devices RESULT : Pass Test Specification Test item : Light-up costume Identification / Type No. : SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC FCC ID : 2BPL9-IRBLHC001 Test standard : CFR47 FCC Part 2: Section 2.1093 FCC KDB Publication 447498 D04 Calculation Method according to KDB 447498 D04 and f is in GHz, d is the separation distance (cm), and ERP20cm is per Formula (B.1). The example values shown in Table B.2 are for illustration only. FCC Measurement Record: Test Mode Conducted Power (dBm) Conducted Power (mW) Minimum Separation Distances (mm) Limit (mW) BLE 2.46 1.76 5 2.72
EFGX26040261-IE-02-E03 Appendix 1 / 35 Appendix A: DTS Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.684 2401.576 2402.260 0.5 PASS 2440 0.668 2439.580 2440.248 0.5 PASS 2480 0.552 2479.664 2480.216 0.5 PASS EFGX26040261-IE-02-E03 Appendix 2 / 35 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 EFGX26040261-IE-02-E03 Appendix 3 / 35 EFGX26040261-IE-02-E03 Appendix 4 / 35 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.85537 2401.4874 2402.3427 --- --- 2440 0.87200 2439.4683 2440.3403 --- --- 2480 0.63057 2479.5778 2480.2084 --- --- EFGX26040261-IE-02-E03 Appendix 5 / 35 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 EFGX26040261-IE-02-E03 Appendix 6 / 35 EFGX26040261-IE-02-E03 Appendix 7 / 35 Appendix C: Maximum conducted output power Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 2.46 ≤30 PASS 2440 1.93 ≤30 PASS 2480 1.43 ≤30 PASS EFGX26040261-IE-02-E03 Appendix 8 / 35 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 EFGX26040261-IE-02-E03 Appendix 9 / 35 EFGX26040261-IE-02-E03 Appendix 10 / 35 Appendix D: Maximum power spectral density Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -12.29 ≤8.00 PASS 2440 -12.91 ≤8.00 PASS 2480 -9.24 ≤8.00 PASS EFGX26040261-IE-02-E03 Appendix 11 / 35 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 EFGX26040261-IE-02-E03 Appendix 12 / 35 EFGX26040261-IE-02-E03 Appendix 13 / 35 Appendix E: Band edge measurements Test Result TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 1.30 -34.58 ≤-18.71 PASS High 2480 0.70 -41.73 ≤-19.3 PASS EFGX26040261-IE-02-E03 Appendix 14 / 35 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 EFGX26040261-IE-02-E03 Appendix 15 / 35 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference 0.67 0.67 --- PASS 30~1000 0.67 -50.94 ≤-19.33 PASS 1000~25000 0.67 -39.82 ≤-19.33 PASS 2440 Reference -0.09 -0.09 --- PASS 30~1000 -0.09 -51.22 ≤-20.09 PASS 1000~25000 -0.09 -38.32 ≤-20.09 PASS 2480 Reference 0.36 0.36 --- PASS 30~1000 0.36 -50.84 ≤-19.64 PASS 1000~25000 0.36 -38.15 ≤-19.64 PASS EFGX26040261-IE-02-E03 Appendix 16 / 35 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~25000 EFGX26040261-IE-02-E03 Appendix 17 / 35 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 EFGX26040261-IE-02-E03 Appendix 18 / 35 BLE_1M_Ant1_2440_1000~25000 BLE_1M_Ant1_2480_0~Reference EFGX26040261-IE-02-E03 Appendix 19 / 35 BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~25000 EFGX26040261-IE-02-E03 Appendix 20 / 35 EFGX26040261-IE-02-E03 Appendix 21 / 35 Appendix G: Duty Cycle Test Result TestMode Antenna Channel ON Time [ms] Period [ms] X DC [%] BLE_1M Ant1 2402 0.40 0.63 0.6349 63.49 2440 0.40 0.63 0.6349 63.49 2480 0.40 0.63 0.6349 63.49 EFGX26040261-IE-02-E03 Appendix 22 / 35 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 EFGX26040261-IE-02-E03 Appendix 23 / 35 EFGX26040261-IE-02-E03 Appendix 24 / 35 Appendix H: Emissions in Restricted Bands Test Result Mode: BLE 1M Channel: 2402MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/ m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2310.0000 37.46 40.13 2.67 74.00 33.87 150 356 PK Horizontal PASS 2 2322.4800 39.04 41.91 2.87 74.00 32.09 150 56 PK Horizontal PASS 3 2334.9600 38.91 41.72 2.81 74.00 32.28 150 206 PK Horizontal PASS 4 2352.7700 39.50 42.45 2.95 74.00 31.55 150 151 PK Horizontal PASS 5 2366.6800 39.44 42.43 2.99 74.00 31.57 150 151 PK Horizontal PASS 6 2390.0000 39.13 42.08 2.95 74.00 31.92 150 356 PK Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level EFGX26040261-IE-02-E03 Appendix 25 / 35 Mode: BLE 1M Channel: 2402MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/ m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2310.0000 37.61 40.28 2.67 74.00 33.72 150 212 PK Vertical PASS 2 2318.7100 39.61 42.52 2.91 74.00 31.48 150 348 PK Vertical PASS 3 2333.6600 39.82 42.59 2.77 74.00 31.41 150 158 PK Vertical PASS 4 2354.2000 39.67 42.64 2.97 74.00 31.36 150 302 PK Vertical PASS 5 2372.1400 40.36 43.38 3.02 74.00 30.62 150 102 PK Vertical PASS 6 2390.0000 37.35 40.30 2.95 74.00 33.70 150 58 PK Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level EFGX26040261-IE-02-E03 Appendix 26 / 35 Mode: BLE 1M Channel: 2480MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/ m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2483.5000 48.89 52.35 3.46 74.00 21.65 150 4 PK Horizontal PASS 2 2484.6000 47.34 50.85 3.51 74.00 23.15 150 25 PK Horizontal PASS 3 2486.4500 43.81 47.31 3.50 74.00 26.69 150 9 PK Horizontal PASS 4 2488.7500 42.34 45.88 3.54 74.00 28.12 150 22 PK Horizontal PASS 5 2492.9500 40.09 43.66 3.57 74.00 30.34 150 14 PK Horizontal PASS 6 2500.0000 37.75 41.25 3.50 74.00 32.75 150 278 PK Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level EFGX26040261-IE-02-E03 Appendix 27 / 35 Mode: BLE 1M Channel: 2480MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/ m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2483.5000 40.89 44.35 3.46 74.00 29.65 150 52 PK Vertical PASS 2 2484.2000 40.20 43.68 3.48 74.00 30.32 150 76 PK Vertical PASS 3 2489.0000 39.75 43.31 3.56 74.00 30.69 150 360 PK Vertical PASS 4 2492.7000 39.55 43.12 3.57 74.00 30.88 150 348 PK Vertical PASS 5 2497.9000 39.38 42.96 3.58 74.00 31.04 150 151 PK Vertical PASS 6 2500.0000 37.98 41.48 3.50 74.00 32.52 15…
Text truncated - open the document above for the full version.
EUROFINS ELECTRICAL TESTING SERVICE (SHENZHEN) CO., LTD. RADIO TEST - REPORT FCC Compliance Test Report for Product name: Light-up costume Model name: SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP-LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP-LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC FCC ID: 2BPL9-IRBLHC001 Test Report Number: EFGX26040261-IE-02-E03 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Phone: +86-0755-829118671 Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8 Fax: +86-0755-82910749 Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 1 of 26 1 General Information 3 1.1 Notes 3 1.2 Testing laboratory 4 1.3 Details of applicant 4 1.4 Details of manufacturer 4 1.5 Application details 5 1.6 Test item 5 1.7 Test standards 6 2 Technical test 7 2.1 Summary of test results 7 2.2 Test environment 7 2.3 Measurement uncertainty 7 2.4 Test mode 8 2.5 Test equipment utilized 9 2.6 Auxiliary equipment used during test 10 2.7 Test software information 10 2.8 Test setup 11 2.9 Test results 13 3 Technical Requirement 14 3.1 Conducted emission AC power port 14 3.2 Duty cycle 15 3.3 6dB bandwidth 16 3.4 99% Occupied Bandwidth 17 3.6 Conducted Peak output power 18 3.7 Power spectral density 19 3.8 Conducted Spurious Emissions 20 3.9 Band edge 21 3.10 Spurious radiated emissions for transmitter 24 4 Test Setup Photos 26 5 External Photo 26 6 Internal Photos 26 7 Appendix 26 Test Report No.: EFGX26040261-IE-02-E03 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 3 of 26 1 General Information 1.1 Notes The results of this test report relate exclusively to the item tested as specified in chapter “Description of test item” and are not transferable to any other test items. Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Is not responsible for any generalisations and conclusions drawn from this report. Any modification of the test item can lead to invalidity of test results and this test report may therefore be not applicable to the modified test item. The test report may only be reproduced or published in full. Reproducing or publishing extracts of the report requires the prior written approval of the Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. This document is subject to the General Terms and Conditions and the Testing and Certification System of Eurofins Electrical Testing Service (Shenzhen) Co., Ltd., available on request or accessible at www.eurofins.com. Operator: 2026-05-08 Bruce Zheng / Project Engineer Date Eurofins-Lab. Name / Title Signature Technical responsibility for area of testing: 2026-05-08 Albert Xu / Lab Manager Date Eurofins-Lab. Name / Title Signature Test Report No.: EFGX26040261-IE-02-E03 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 4 of 26 1.2 Testing laboratory Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Telephone : +86-755-82911867 Fax : +86-755-82910749 The Laboratory has passed the Accreditation by the American Association for Laboratory Accrediation (A2LA). The Accreditation number is 5376.01 The Laboratory has been listed by industry Canada to perform electromagnetic emission measurements, The CAB identifier is CN0088 1.3 Details of applicant Name : Guangzhou Weijie Trading Co., Ltd Address : B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China 1.4 Details of manufacturer Name : Guangzhou Weijie Trading Co., Ltd Address : B001, Room 105, No. 21, Xinyi Road, Baiyun District, Guangzhou City, China Test Report No.: EFGX26040261-IE-02-E03 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 5 of 26 1.5 Application details Date of receipt of application : 2026-04-09 Date of receipt of test item : 2026-04-09 Date of test : 2026-04-09 to 2026-05-07 Date of issue : 2026-05-08 1.6 Test item Product type : Light-up costume Test Model : SP-LE91HC, SP-LE100HC, SP-LF51HC, SP-LF76HC, SP- LF83HC, SP-LE96HC, SP-LE30HC, SP-LE18HC, SP- LE09HC, SP-LE56HC, SP-LE27HC, LE91HC, LF51HC, LE30HC, LE96HC, LE09HC, LE18HC Sample ID : 260415-35-001 Brand : ./. Serial number : ./. Ratings : DC 4.5V Test voltage : DC 4.5V RadioTechnical data Frequency range : 2402MHz – 2480MHz Radio Tech. : Bluetooth Low Energy Frequency channel : 40 Channels Modulation : GFSK 1Mbps Antenna type : PCB antenna Maximum antenna gain : 0dBi Additional information : All models are the same, except for the model name. Therefore full tests were performed on model SP-LE91HC in this report. The above sample(s) and sample information was/were submitted and identified on behalf of the applicant. Eurofins assures objectivity and impartiality of the test, and fulfills the obligation of confidentiality for applicant’s commercial infor- mation and technical documents. Test Report No.: EFGX26040261-IE-02-E03 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 6 of 26 1.7 Test standards Test Standards FCC Part 15 Subpart C PART 15 – RADIO FREQUENCY DEVICES Subpart C – Intentional Radiators Test Method 1: ANSI C63.4-2014, Americ…
Text truncated - open the document above for the full version.
Antenna describe 1. Antenna describe: Antenna plate PCB ANTENNA Make name/model name PDT-002 Antenna gain 0dBi Frequency range 2.4GHZ-2.483GHZ Connector type direct Manufacturer Name: DONGGUANG XIAOKE INDUSTRLES.CO.,LTD Manufacture Address: NO. 227, DONGCHENG SECTION, GUANDONG ROAD, DONGCHENG STREET, DONGGUAN CITY,CHINA 2.External view drawing: Picture of antenna Antenna Dimensions L1 2.15 mm L2 1.20 mm L3 1.95 mm W1 0.35 mm W2 0.35 mm D1 1.25 mm D2 1.65 mm D3 0.50 mm 3.Antenna Radiation Pattern
EFGX26040261-IE-02-Setup Photos 1 / 2 EFGX26040261-IE-02-Setup Photos 2 / 2
5379 Pine Valley Ct · Bolder, 80301 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.76 mW |