Dated: June 10, 2026 Nemko North America, Inc. 303 River Road Ottawa ON K1V 1H2 Canada Covered Equipment Certification Attestation Letter Applicant: Strato Automation, Inc. FCC ID: 2BPMM-OSTXXXMHCW The applicant certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section §2.903 of the FCC rules. This includes certifying that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current FCC Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. The applicant certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Name: Steve Grothé Title: Firmware and Hardware Manager Company: Strato Automation Inc Address: 1550b Rue de Coulomb, Boucherville, QC Phone: (514) 317-7923 Email: [email protected]
* The agent’s name must exactly match the primary contact person listed in the FRN registration details. ** The Agent FRN may be the same as the applicant’s if the agent and the applicant are the same U.S.-based legal entity. Dated: June 10, 2026 Nemko North America, Inc. 303 River Road Ottawa ON K1V 1H2 Canada U.S. Agent Designation for Service of Process Attestation Letter FCC ID: 2BPMM-OSTXXXMHCW Applicant FRN: 0036932556 This letter serves as a formal designation, pursuant to §2.911(d)(7) of the FCC Rules, of the following U.S. Agent for Service of Process for the equipment under application: U.S. Agent for Service of Process: • Company Name: Strato Automation USA LTD • Physical U.S. Company Address: 4076 Saddleback Ln Cheyenne, WY 82001 • Agent Name*: Tony Bonifay • Agent Email Address: [email protected] • Agent FRN**: N/A The above listed designated agent hereby acknowledges and accepts the obligation for service of process on behalf of the applicant signed below. The applicant further acknowledges and accepts its obligation to maintain a U.S. Agent for Service of Process for a minimum period of one year following either: • Permanent termination of all marketing and importation activities within the U.S. for the applicable equipment by the grantee. • The conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever occurs later. Applicant Signed: Designated Agent Signed: (Required, if different to Applicant) Signed: Signed: Printed name: Steve Grothé Printed name: Tony Bonifay Title: Firmware and Hardware Manager Title: Sales and Systems Engineering Director - US Company Name: Strato Automation Inc Company Name: Strato Automation USA LTD Phone: (514) 317-7923 Phone: (405) 839-4617 Email: [email protected] Email: [email protected]
Strato Automation, Inc. 1550-B Rue de Coulomb, Boucherville, Quebec, Canada J4B 7Z7 Attn: Director of Certification Appointment of Agent for FCC and ISED Certification Application Dear Director of Certification, This letter formally appoints Spencer Zhong of Nemko Canada, Inc. located at 303 River Road, Ottawa, Ontario, Canada K1V 1H2, as our authorized agent to represent us in the application process for equipment certification. We confirm that the submitted documents accurately depict the device or system seeking certification. Additionally, we guarantee that all units produced, imported, or marketed, as defined by FCC and ISED Canada regulations, will possess a label identical to the one submitted with this application. By signing below, we certify that neither our company nor any party involved in the application is subject to denial of federal benefits, including FCC benefits, as outlined in Section 5301 of the Anti- Drug Abuse Act of 1988 (21 U.S.C. §862) due to a conviction for possession or distribution of a controlled substance. Furthermore, no party involved in the application, as defined in 47 CFR 1.2002 (b), is subject to denial of federal benefits, including FCC benefits. We attest to the truth and accuracy of the information provided to the FCC to the best of our knowledge (47 CFR 2.911 (d)) and acknowledge our responsibilities as a grantee regarding certified equipment (47 CFR 2.909). In instances where our authorized agent signs the application for certification on our behalf, we understand that Nemko North America, Inc. remains solely responsible for adhering to the terms and conditions for certification as specified by Nemko Canada Inc. Sincerely, Dated: June 5, 2026 Agency agreement expiration date: June 5, 2027 *Up to 12 months Signed by: Steve Grothé Signature Print name Firmware and Hardware Manager Title (514) 317-7923 Phone On behalf of: Strato Automation Inc. Company name
June 5, 2026 Strato Automation, Inc. 1550-B rue de Coulomb, Boucherville, QC J4B 7Z7 Attn: Director of Certification Request for Confidentiality – FCC FCC ID: 2BPMM-OSTXXXMHCW Pursuant to FCC 47 CFR 0.457(d)(1)(ii) and 0.459 and FCC guidance published in KDB 726920, we hereby request confidential treatment of information accompanying this application as outlined below. We request the exhibits selected below as long term confidential (LTC) be withheld from public view permanently: Selection of exhibits for LTC - general Exhibit name ☒ Permanent (Long Term) Block Diagrams ☒ Permanent (Long Term) Operation Description / Theory of Operation ☒ Permanent (Long Term) Parts List & Placement / BOM ☒ Permanent (Long Term) Schematics Selection of exhibits for LTC - specific 1 Exhibit name ☐ Permanent (Long Term) Tune-Up Procedure ☐ Permanent (Long Term) SDR 2 Software / Security Info We also request the exhibits selected below as short term confidential (STC) be withheld from public view for a period of 30 days 3 from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public: Selection of exhibits for STC 4 Exhibit name ☒ Short Term User’s Manual ☒ Short Term Internal Photos ☒ Short Term External Photos ☒ Short Term Test Setup Photos ☐ Short Term Tune-Up Procedure (for Licensed equipment only) Our company has spent a substantial effort in developing this product and it is one of the first of its kind in the industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. When the device is marketed before the requested number of days listed above, the grantee will inform the TCB to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. 1 - Tune up procedure is applicable only for licensed equipment. 2 - The FCC rules require that any radio, in which the software is designed or expected to be modified by a party other than the manufacturer that would affect the operating parameters of frequency range, modulation type, maximum output power or other radio frequency parameters outside the range under which the transmitter has been approved in accordance with the FCC rules, must be certified as a software-defined radio (SDR). 3 - Number of days can be listed up to 180 but should not go past the date of beginning of product marketing/sale. 4 - Any exhibits that may have already been requested to have “Permanent” confidentiality need not be repeated under Short-Term confidentiality request. The above information contains trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Sincerely, Signed by: Steve Grothé Signature Print name Firmware and Hardware Manager Title (514) 317-7923 Phone Strato Automation Inc Company 1550-B Rue de Coulomb, Boucherville, QC J4B 7Z7 Address
Dated: June 12, 2026 Nemko North America, Inc. 303 River Road, Ottawa, ON K1V 1H2 Canada Attn: Director of Certification Family Certification request letter - FCC FCC ID: 2BPMM-OSTXXXMHCW Model numbers: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW- 1, OSTV424HW, OSTV424MHW, OSTV424MHCW Model names: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW We, Strato Automation Inc., hereby request certification for a product family under a single application and FCC ID. The base model and its variants share the same core design and technical characteristics, with only minor differences that do not affect compliance with FCC requirements. Details of the product family are as follows: Base Model: OST537MHCW Variant Models: OST537HW, OST537HW-1, OST537MHW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Model Name Inputs/Outpu ts Humidit y (H) Motion (M) CO2 (C) WiFi (W) Antenna Type & Gain Enclosure Consistency RS-485 Qty OST537HW Varies Yes No No Yes Same Same 2 OST537HW-1 Varies Yes No No Yes Same Same 1 OST537MHW Varies Yes Yes No Yes Same Same 2 OST537MHCW Varies Yes Yes Yes Yes Same Same 2 OST300HW-1 Varies Yes No No Yes Same Same 1 OSTV424HW Varies Yes No No Yes Same Same 2 OSTV424MHW Varies Yes Yes No Yes Same Same 2 OSTV424MHCW Varies Yes Yes Yes Yes Same Same 2 Justification: All models listed above are electrically and mechanically identical, and share the same antenna type and gain, with variations limited to cosmetic features, branding, enclosure color, and product labeling, as well as minor non-RF functional options. Variants may include different combinations of humidity (H), motion sensing (M), and CO₂ sensing capabilities, along with different numbers of analog and digital inputs/outputs. These I/O variations are implemented using the same PCB platform with population differences defined by the BOM. These differences do not impact RF performance or compliance with applicable regulations. The test results obtained for base model within this family can be applied to all other model variants, considering their similarities We respectfully request that these models be certified under a single application to streamline the approval process and ensure consistent regulatory compliance. Should you require any additional information or documentation, please do not hesitate to contact us. Sincerely, Signature: Name: Steve Grothé Title: Firmware and Hardware Manager Company: Strato Automation Inc Address: 1550-B Rue de Coulomb, Boucherville, QC Phone: (514) 317-7923 Email: [email protected]
Dated: June 3, 2026 Nemko North America, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification FCC and/or ISED signature authorization letter Dear Director of Certification, I, the undersigned, hereby authorize Steve Grothé of Strato Automation Inc., located at 1550b Rue de Coulomb, Boucherville, QC, to act on my behalf in matters relating to equipment certification. This authorization includes the authority to prepare and submit applications, sign related documents, and correspond with the FCC, ISED, and/or a Telecommunication Certification Body (TCB) in connection with the certification process. Sincerely, Signature: Name: Steve Lupien Title: Chief Innovation and Technology Officer Company: Strato Automation Inc. Address: 1550b Rue de Coulomb, Boucherville, QC Phone: (514) 465-2808 Email: [email protected]
Box Label FCC ID: 2BPMM-OSTXXXMHCW IC: 34000-OSTXXXMHCW Contains FCC ID : 2AC7Z-ESPC6WROOM1 Contains IC: 21098-ESPC6WROOM1 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Product labels Model (HVIN): OST300HW-1 Model (HVIN): OST537HW Model (HVIN): OST537HW-1 Model (HVIN): OST537MHCW Model (HVIN): OST537MHW Model (HVIN): OSTV424HW Model (HVIN): OSTV424MHCW Model (HVIN): OSTV424MHW
www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by ANSI National Accreditation Board (ANAB). The test results included in this report are within the scope of this accreditation. The ANAB symbol is an official symbol of the ANSI National Accreditation Board, used under licence. FCC and ISED RSS-102– MPE Calculation; Date: January 2026 RF Exposure Compliance – MPE Calculation Report C h o o s e S c a n d i n a v i a n t r u s t Applicant company: Strato Automation Inc. Model number (HVIN): OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Model name (PMN): OpenStat Touch FCC Identification: FCC ID: 2BPMM-OSTXXXMHCW ISED certification number: IC: 34000-OSTXXXMHCW Product type: Mobile or Fixed Device Device category Consumer Device for General Population/Uncontrolled Exposure Date of issue: July 13, 2026 Compliance Specifications: FCC 47 CFR Part 1 Subpart I, §§1.1307, 1.1310 FCC 47 CFR Part 2 Subpart J, §§2.1091, 2.1093 FCC KDB 447498 D01 General RF Exposure Guidance v06 FCC KDB 865664 D01 RF Exposure Procedures and Equipment Authorization Policies ISED Canada RSS-102 Issue 6 December 15, 2023 MPE calculation report Product info: FCC ID: 2BPMM-OSTXXXMHCW IC: 34000-OSTXXXMHCW Model: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Page 2 of 8 Test locations of Nemko Canada Inc. Ottawa site Montréal site GTA Cambridge site Facility address 303 River Road Ottawa, Ontario Canada K1V 1H2 Tel: +1 613 737 9680 Fax: +1 613 737 9691 292 Labrosse Avenue Pointe-Claire, Québec Canada H9R 5L8 Tel: +1 514 694 2684 Fax: +1 514 694 3528 1-130 Saltsman Drive Cambridge, Ontario Canada N3E 0B2 Tel: +1 519 650 4811 Test site identifier - FCC CA2040 CA2041 CA0101 Test site identifier – ISED Canada 2040A-4 2040G-5 24676 ANAB File Number AT-3195 AT-3193 AT-3194 Andrey Adelberg Senior EMC/Wireless Specialist Prepared by Signature Limits of responsibility The results presented in this report apply solely to the specific device model tested and are valid only for the operating conditions and installation requirements specified herein. Testing was conducted in accordance with ISO/IEC 17025:2017 requirements, and all results fall within the scope of Nemko Canada's accreditation. This MPE evaluation is based on the maximum power levels and operating conditions specified. Any modifications to the device hardware, software, or installation that could affect RF output power or antenna characteristics may invalidate this compliance demonstration. Copyright notification This report may be reproduced by the applicant in its entirety for regulatory submission and internal use. Any use of this report by third parties, including reliance on its contents or decisions made based on it, is solely at the risk of those third parties. Nemko Canada Inc. assumes no responsibility for any damages incurred by third parties as a result of actions taken based on this report. © Nemko Canada Inc. All rights reserved. MPE calculation report Product info: FCC ID: 2BPMM-OSTXXXMHCW IC: 34000-OSTXXXMHCW Model: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Page 3 of 8 1. Executive Summary This report presents the Maximum Permissible Exposure (MPE) analysis to demonstrate compliance with FCC and ISED RF exposure requirements. The evaluation considers both single transmitter operation and simultaneous multi-transmitter scenarios where applicable. 2. Key Findings Compliance status Complies Critical separation distances 20 cm Special conditions or limitations N/A MPE calculation report Product info: FCC ID: 2BPMM-OSTXXXMHCW IC: 34000-OSTXXXMHCW Model: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Page 4 of 8 MPE calculations for simultaneous transmission Device Classification Requirements Portable Device Definition (§2.1093) Devices designed for use by a person where the radiating structure is within 20 cm of the user's body require SAR evaluation rather than MPE calculation. Mobile Device Definition Devices installed in vehicles or with permanently installed antennas may use MPE calculations if minimum separation distances can be established. Fixed/Base Station Definition Stationary transmitters with controlled access to antenna locations may use MPE calculations for both occupational and general population exposure scenarios. 3. References, definitions and limits for FCC FCC §2.1091(d) (2) For operations within the frequency range of 300 kHz and 6 GHz (inclusive), the limits for maximum permissible exposure (MPE), derived from whole-body SAR limits and listed in Table 1 in paragraph (e)(1) of this section, may be used instead of whole-body SAR limits as set forth in paragraphs (a) through (c) of this section to evaluate the environmental impact of human exposure to RF radiation as specified in §1.1307(b) of this part, except for portable devices as defined in §2.1093 of this chapter as these evaluations shall be performed according to the SAR provisions in §2.1093. Table 1: §1.1310(e)(1)—Power Density Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3–3.0 *(100) ≤6 3.0–30 *(900 / f 2 ) <6 30–300 1.0 <6 300–1500 f / 300 <6 1500–100000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3–1.34 *(100) <30 1.34–30 *(180 / f 2 ) <30 30–300 0.2 <30 300–1500 f / 1500 <30 1500–100000 1.0 <30 Notes: f = frequency in MHz. * = Plane-wave equivalent power density. MPE calculation report Product info: FCC ID: 2BPMM-OSTXXXMHCW IC: 34000-OSTXXXMHCW Model: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW Page 5 of 8 4. References, definitions and limits for ISED RSS-102 Section 5.3.2 The power density reference levels, and associated reference period for devices employed by the general public (uncont…
Text truncated - open the document above for the full version.
www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by ANSI National Accreditation Board (ANAB). The tests included in this report are within the scope of this accreditation. The ANAB symbol is an official symbol of the ANSI National Accreditation Board, used under licence. ANAB File Number: AT-3195 (Ottawa/Almonte); AT-3193 (Pointe-Claire); AT-3194 (Cambridge) C h o o s e S c a n d i n a v i a n t r u s t RADIO TEST REPORT Report ID: Project number: REP166947 PRJ0102022 Type of assessment: Final product testing Type of radio equipment: HVAC Controller incorporating a 60 GHz field disturbance sensor Applicant: Description of product: Strato Automation Inc. OpenStat Touch OST537 Series HVAC Controller Product marketing name (PMN): OpenStat Touch Models/HVINs: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW FCC identifier: ISED certification number: FCC ID: 2BPMM-OSTXXXMHCW IC:34000-OSTXXXMHCW Specifications: FCC 47 CFR Part 15 Subpart C, §15.255 RSS-210 Issue 11, June 2024, Annex J Date of issue: July 14, 2026 Atefeh Beiginezhad, EMC/RF Specialist Tested by David Duchesne, Senior EMC/Wireless Specialist Reviewed by Signature Report reference ID: REP166947 Page 2 of 34 Lab locations Company name Nemko Canada Inc. Facilities Ottawa site: 303 River Road, Ottawa, ON, Canada, K1V 1H2 Tel: +1 613 737 9680, Fax: +1 613 737 9691 Montréal site: 292 Labrosse Avenue, Pointe-Claire, QC, Canada, H9R 5L8 Tel: +1 514 694 2684, Fax: +1 514 694 3528 Cambridge site: 1-130 Saltsman Drive, Cambridge, ON, Canada, N3E 0B2 Tel: +1 519 650 4811 Test site registration number: − CA2040 (Ottawa) − CA2041 (Montreal) − CA0101 (Cambridge) Website www.nemko.com Limits of responsibility Note that this report's results relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of this report. This test report has been completed following the requirements of ISO/IEC 17025. All results contained in this report are within Nemko Canada's ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report, provided it is reproduced in its entirety and for use by the company's employees only. Any use that a third party makes of this report, or any reliance on, or decisions made based on it, is such third parties' responsibility. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party due to decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: REP166947 Page 3 of 34 Table of Contents Table of Contents ......................................................................................................................................................................................................... 3 Report summary ................................................................................................................................................................................. 4 1.1 Test specifications .................................................................................................................................................................................................... 4 1.2 Test methods ............................................................................................................................................................................................................ 4 1.3 Exclusions ................................................................................................................................................................................................................. 4 1.4 Statement of compliance .......................................................................................................................................................................................... 4 1.5 Test report revision history ....................................................................................................................................................................................... 4 Engineering considerations ................................................................................................................................................................. 5 2.1 Modifications incorporated in the EUT for compliance ............................................................................................................................................ 5 2.2 Technical judgment .................................................................................................................................................................................................. 5 2.3 Model variant declaration ........................................................................................................................................................................................ 5 2.4 Deviations from laboratory tests procedures ........................................................................................................................................................... 5 Test conditions ................................................................................................................................................................................... 6 3.1 Atmospheric conditions ............................................................................................................................................................................................ 6 3.2 Power supply range .................................................................................................................................................................................................. 6 Information provided by the applicant ...................................................................................................................…
Text truncated - open the document above for the full version.
Dated: June 12, 2026 Subject: Antenna Justification Letter for FCC Part 15 Compliance FCC ID: 2BPMMOSTXXXMHCW Model Number: OST537HW, OST537HW-1, OST537MHW, OST537MHCW, OST300HW-1, OSTV424HW, OSTV424MHW, OSTV424MHCW To Whom It May Concern, This letter provides justification for the antenna configuration used in the above-referenced device, submitted for certification under FCC Part 15. Radiated Measurement Justification All compliance testing, including fundamental and spurious emissions, was performed using radiated measurement methods. As such, antenna gain and performance characteristics were inherently captured in the test results. Therefore, no separate antenna gain documentation is required to demonstrate compliance with FCC limits. This approach aligns with the guidance provided in the FCC TCB Workshop (October 2022) and KDB 353028 D01, which allows for a justification statement in lieu of antenna gain documentation when radiated measurements are used exclusively. Antenna 1 – ESP32-C6-WROOM-1 (Wi-Fi/Bluetooth): • Antenna Type: PCB trace antenna (integrated) • Location: Integrated on the ESP32-C6-WROOM-1 module mounted on the main PCB • Dimensions: Approximately 25.5 mm × 18.0 mm × 3.3 mm (entire module) • Estimated Peak Gain: 2.0 dBi (per Espressif datasheet) • Polarization: Linear • Orientation: Horizontal • Frequency Bands Supported: o 2.4 GHz ISM (2400–2483.5 MHz) for Wi-Fi and BLE o Sub-GHz not supported on this module Antenna 2 – BGT60LTR11AIP (Radar Sensor): • Antenna Type: Integrated patch antennas (Tx and Rx array embedded in package) • Location: Internal to the BGT60LTR11AIP chip, surface-mounted on PCB • Dimensions: Approx. 6.7 mm × 5.0 mm × 0.9 mm (package size) • Estimated Peak Gain: o Tx: ~6.0 dBi o Rx: ~6.0 dBi • Polarization: Linear • Orientation: Vertical (relative to package mounting) • Frequency Bands Supported: 60 GHz band (57–64 GHz, ISM) Antenna 3 – ST25DV64KC (NFC): • Antenna Type: PCB loop antenna (integrated on the main PCB) • Location: Copper trace loop integrated into the main PCB and connected to the • ST25DV64KC NFC dynamic tag IC • Dimensions: Approximately 10 mm x 18 mm (PCB antenna area) • Estimated Peak Gain: Not applicable (passive near-field inductive loop antenna) • Polarization: Magnetic field (H-field) • Orientation: Parallel to the front surface of the product enclosure • Frequency Bands Supported: 13.56 MHz ISM band (13.553-13.567 MHz) for NFC operation compliant with ISO/IEC 15693. Supporting details and materials 1. Internal Photographs 2. PCB Layout Diagrams • See above image 3. Antenna Specifications • Based on Espressif ESP32-C6-WROOM-1 datasheet and Infineon BGT60LTR11AIP product brief and application notes. 4. Estimated Gain Information • Taken from manufacturer data and simulation-based references. No additional passive gain structures are present. Compliance Statement The antenna configuration has not been altered in a way that would affect radiated performance. No external gain-enhancing accessories (e.g., reflectors, lenses) are used. The antenna is permanently affixed and not user-accessible or replaceable. Should you require any additional information or clarification, please do not hesitate to contact us. Sincerely, Steve Grothé Firmware and Hardware Manager Strato Automation Inc. (514) 317-7923
4076 Saddleback Ln · Cheyenne, 82001 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.255 | 61.00 GHz - 61.50 GHz | 4.89 mW |
OpenStat OS537 Series HVAC Controller
Equipment Class
FDS - Part 15 Field Disturbance Sensor