Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev 1/26/2023 Core Devices LLC Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-03-11 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BQB2-PEBBLETIME2 Core Devices LLC ("the applicant")certifies that the equipment for which authorization is sought is not“covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicantsignature) (Applicant printed name) Eric Migicovsky Rev 1/26/2023 Core Devices LLC Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-03-11 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BQB2-PEBBLETIME2 Core Devices LLC (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List(as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Eric Migicovsky
Core Devices LLC SC 3021622 U.S. Agent Designation for Service of Process - Certification Attestation Letter 1/20/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BQB2-PEBBLETIME2 Per section 2.911(d)(7) of the FCC rules, Core Devices LLC certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Core Devices LLC FCC Registration Number (FRN): 0037172152 Physical U.S. Company Address: 2261 Market Street, STE 22843, San Francisco, California, United States Contact Person: Eric Migicovsky Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Signed: Printed name: Eric Migicovsky Printed name: Eric Migicovsky Title: Manager Title: Manager Company Name: Core Devices LLC Company Name: Core Devices LLC Date: 3/11/2026 Date: 3/11/2026
RF_160, Issue 03 Declaration of Authorization We Name: Core Devices LLC Address: 2261 Market Street, STE 22843 City: San Francisco State or Country: California, United States Declare that: Name Representative of agent: Lisa Wang (1) Agent Company name: EMTEK (SHENZHEN) CO., LTD. Address: Bldg 69, Majialong Industry Zone, Nanshan District, City: Shenzhen Country China is authorized to apply for Certification of the following product(s): Product description: smart watch Type designation: Pebble Time2 Trademark: Pebble FCC ID: 2BQB2-PEBBLETIME2 on our behalf. Date: 2026-03-11 Name: Eric Migicovsky Function: Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Core Devices LLC Address : 2261 Market Street, STE 22843 City: San Francisco Country: California, United States To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: 2BQB2-PEBBLETIME2 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: The product is not on the market yet Planned Release Date STC: 180Days (notes 2, 3, 4, 5) Date: 2026-03-11 Name and signature of applicant: Eric Migicovsky Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
Step-by-step instructions on how to view the label information 1、Enter the settings menu 2、Enter the system menu 3、Enter the certification menu label information Product Model:Pebble Time2 Product Name:smart watch Trademark:Pebble Place of origin:Made in China IC ID:34223-PEBBLETIME2 FCC ID:2BQB2-PEBBLETIME2 DC input:5V/300mA Rated voltage:3.8V Milliampere-hour:185mAh Watt-hour : 0.71Wh Attached Logo (written into the software):
Report No.ENS2512190252W00106R Page 1 of 33 Ver.1.0 TEST REPORT Product Name : smart watch Model Number : Pebble Time2 FCC ID : 2BQB2-PEBBLETIME2 Prepared for : Core Devices LLC Address : 2261 Market Street STE 22843 San Francisco Prepared by : EMTEK (SHENZHEN) CO., LTD. Address : Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guan gdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Numbe r : ENS2512190252W00106R Date(s) of Tests : January 12, 2026 to January 12, 2026 Date of Issue : Januar y 13, 2026 $二维码$ Report No.ENS2512190252W00106R Page 2 of 33 Ver.1.0 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION ............................................................................................................................ 4 2. Description of Equipment Under Test .................................................................................................................. 6 3. SAR Measurement System .................................................................................................................................... 7 3.1 Definition of Specific Absorption Rate (SAR) ................................................................................................... 7 3.2 SPEAG DASY System ..................................................................................................................................... 7 3.2.1 Robot .................................................................................................................................................. 8 3.2.2 Probes ................................................................................................................................................ 9 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................... 9 3.2.4 Phantoms ......................................................................................................................................... 10 3.2.5 Device Holder ................................................................................................................................... 11 3.2.6 System Validation Dipoles ................................................................................................................ 11 3.2.7 Tissue Simulating Liquids ................................................................................................................. 12 3.3 SAR System Verification ................................................................................................................................ 14 3.4 SAR Measurement Procedure ....................................................................................................................... 15 3.4.1 Area & Zoom Scan Procedure ......................................................................................................... 15 3.4.2 VolumeScan Procedure .................................................................................................................... 15 3.4.3 Power Drift Monitoring ...................................................................................................................... 16 3.4.4 Spatial Peak SAR Evaluation ........................................................................................................... 16 3.4.5 SAR Averaged Methods ................................................................................................................... 16 4. SARMeasurement Evaluation .............................................................................................................................. 17 4.1 Applicable Standards ..................................................................................................................................... 17 4.2 EUT Testing Position ...................................................................................................................................... 17 4.2.1 Limb-worn device ............................................................................................................................. 17 4.2.1 SAR Test Exclusion Evaluations ...................................................................................................... 19 4.3 Tissue Verification .......................................................................................................................................... 20 4.4 System Validation ........................................................................................................................................... 20 4.5 System Verification ......................................................................................................................................... 21 4.6 Maximum Output Power ................................................................................................................................. 22 4.6.1 Maximum Conducted Power ............................................................................................................ 22 4.6.2 Measured Conducted Power Result ................................................................................................ 23 4.7 SAR T esting Results ....................................................................................................................................... 24 4.7.1 SAR Test Reduction Considerations ................................................................................................ 24 4.7.2 SAR Results for Body Exposure Condition ...................................................................................... 24 4.7.3 Estimated SAR Calculation .............................................................................................................. 25 5. Calibration of Test Equipment ............................................................................................................................. 26 6. Measurement Uncertainty .....…
Text truncated - open the document above for the full version.
Test Laboratory: Shenzhen EMTEKCo.,Ltd.Date: 2026/1/12 System Check_H2450 DUT: Dipole 2450 MHz; Type:D2450V2; SN:927 Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: H2450 Medium parameters used: f = 2450 MHz;σ=1.75S/m;ε r = 39.60;ρ=1000kg/m 3 AmbientTemperature:22.2°C; LiquidTemperature:22.0°C DASY5 Configuration: - Probe: EX3DV4 - SN3970; Calibrated: 2025/6/5; - Electronics: DAE4 Sn1418; Calibrated: 2025/6/5 - Phantom: SAM; Type: QD000P40CD; Serial: TP:1794 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Pin=250mW/Area Scan (61x61x1):Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 20.6 W/kg Pin=250mW/Zoom Scan (5x5x7)/Cube 0:Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.335 V/m; Power Drift = 0.16 dB Peak SAR (extrapolated) = 20.4 W/kg SAR(1 g) = 13.12 W/kg; SAR(10 g) = 6.10 W/kg Maximum value of SAR (measured) = 21.0 W/kg
TestLaboratory:ShenzhenEMTEKCo.,Ltd.Date:2026/1/12 BT DUT: Pebble Time2 Communication System: BT ; Frequency: 2480 MHz;Duty Cycle: 1:1 Medium: H2450 Medium parameters used: f = 2480 MHz;σ=1.72S/m;ε r = 39.68;ρ=1000kg/m 3 AmbientTemperature:22.2°C; LiquidTemperature:22.0°C DASY5 Configuration: - Probe: EX3DV4 - SN3970; Calibrated: 2025/6/5; - Electronics: DAE4 Sn1418; Calibrated: 2025/6/5 - Phantom: SAM; Type: QD000P40CD; Serial: TP:1794 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Back DH5/Area Scan (9x9x1):Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.311 W/kg Back DH5/Zoom Scan (7x7x7)/Cube 0:Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 12.93 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 0.867 W/kg SAR(1 g) = 0.183 W/kg; SAR(10 g) = 0.064 W/kg Smallest distance from peaks to all points 3 dB below = 4 mm Ratio of SAR at M2 to SAR at M1 = 35% Maximum value of SAR (measured) = 0.594 W/kg
深圳市大显科技有限公司 B TA n t e n n aTe s tR e p o r t Customer COSONIC Project CI-W062S Report Version V3.0 Report Date 2025-11-07 Prepared by Zhiqiang.Chen Checked by Lei.Zhang 2 深圳市大显科技有限公司 Machine image: 3 深圳市大显科技有限公司 Matching circuit: Matching has been changed as follows: C18:N/C C78: 0.5PF C25:18PF L2:15 PF L9:1 NH C19:N/C C79:N/C 4 深圳市大显科技有限公司 Antenna test results: S11 parameter 5 深圳市大显科技有限公司 Passive efficiency of antenna: Free space stateHand model status 6 深圳市大显科技有限公司 Passive field diagram of antenna: 2440MHz Free space state 7 Passive field diagram of antenna: 深圳市大显科技有限公司 2440MHzHand model status 8 深圳市大显科技有限公司 2440MHz Free space state Passive field diagram of antenna: 9 深圳市大显科技有限公司 2440MHz Hand model status Passive field diagram of antenna: 10 深圳市大显科技有限公司 Black border Antenna test results: OTA active test parameters Free space state CHTRP(dBm)TIS(dBm) 0-0.66-76.77 39-0.41-77.49 78-0.6-77.54 Hand model status CHTRP(dBm)TIS(dBm) 0-4.88-72.26 39-4.5-72.58 78-4.21-73 11 深圳市大显科技有限公司 Active field diagram of antenna: 2440MHz Free space state 12 深圳市大显科技有限公司 2440MHz Hand model status Active field diagram of antenna: 13 深圳市大显科技有限公司 Silver border Antenna test results: OTA active test parameters Free space state CHTRP(dBm)TIS(dBm) 0-0.32-76.93 39-0.04-77.75 78-0.1-77.62 Hand model status CHTRP(dBm)TIS(dBm) 0-4.57-73.92 39-4.29-74.2 78-4.11-74.4 14 深圳市大显科技有限公司 Active field diagram of antenna: 2440MHz Free space state 15 深圳市大显科技有限公司 2440MHz Hand model status Active field diagram of antenna: Thanks!!! --------------------- 深圳市大显科技有限公司 16
Report No. ENS2512190252W00102R Page 1 of 54 Ver.1.0 TEST REPORT Product Name : smart watch Model Number : Pebble Time2 FCC ID : 2BQB2-PEBBLETIME2 Prepared for : Core Devices LLC Address : 2261 Market Street STE 22843 San Francisco Prepared b y : EMTEK (SHENZHEN) CO., LTD. Address : Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Numbe r : ENS2512190252W00102R Date(s) of Tests : December 20, 2025 to January 15, 2026 Date of issue : January 16, 2026 $二维码$ Report No. ENS2512190252W00102R Page 2 of 54 Ver.1.0 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION ............................................................................................................ 3 2 EUT TECHNICAL DESCRIPTION .......................................................................................................... 5 3 SUMMARY OF TEST RESULT ............................................................................................................... 6 4 TEST METHODOLOGY .......................................................................................................................... 7 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................... 7 4.2 MEASUREMENT EQUIPMENT USED ......................................................................................... 7 4.3 DESCRIPTION OF TEST MODES ................................................................................................ 8 5 FACILITIES AND ACCREDITATIONS .................................................................................................... 9 5.1 FACILITIES .................................................................................................................................... 9 5.2 LABORATORY ACCREDITATIONS AND LISTINGS ..................................................................... 9 6 TEST SYSTEM UNCERTAINTY ........................................................................................................... 10 7 SETUP OF EQUIPMENT UNDER TEST ............................................................................................... 11 7.1 RADIO FREQUENCY TEST SETUP 1 ........................................................................................ 11 7.2 RADIO FREQUENCY TEST SETUP 2 ........................................................................................ 11 7.3 CONDUCTED EMISSION TEST SETUP .................................................................................... 13 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ........................................................ 14 7.5 SUPPORT EQUIPMENT ............................................................................................................. 14 8 TEST REQUIREMENTS ........................................................................................................................ 15 8.1 DTS 6DB BANDWIDTH ............................................................................................................... 15 8.2 MAXIMUM PEAK CONDUCTED OUTPUT POWER .................................................................. 18 8.3 MAXIMUM POWER SPECTRAL DENSITY ................................................................................ 21 8.4 UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS ................................ 24 8.5 RADIATED SPURIOUS EMISSION ............................................................................................ 35 8.6 CONDUCTED EMISSIONS TEST ............................................................................................... 48 8.7 ANTENNA APPLICATION............................................................................................................ 51 9 APPENDIX P HOTOGRAPHS OF EUT ................................................................................................. 53 10 APPENDIX PHOTOGRAPHS OF TEST SETUP .................................................................................. 54 Report No. ENS2512190252W00102R Page 3 of 54 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant : Core Devices LLC Address: 2261 Market Street STE 22843 San Francisco Manufacturer : Core Devices LLC Address: 2261 Market Street STE 22843 San Francisco EUT : smart watch Model Name : Pebble Time2 Trademark : Pebble Measurement Procedure Used: APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 2 , Subpart J FCC 47 CFR Part 15, Subpart C PASS The above equipment was tested by EMTEK(SHENZHEN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2020) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2 and Part 15.247 The test results of this report relate only to the tested sample identified in this report Date of Test : December 20, 2025 to Januar y 15, 2026 Prepared b y : Yu Xiaolan/Editor Reviewer : Xia Lilu/Supervisor Approved & Authorized Signer : Wan g Li/Manager Report No. ENS2512190252W00102R Page 4 of 54 Ver.1.0 Modified Information Version Report No. Revision Date Summary Ver.1.0 ENS2512190252W00102R / Original Report Report No. ENS2512190252W00102R Page 5 of 54 Ver.1.0 2 EUT TECHNICAL DESCRIPTION Product smart watch Model Number Pebble Time2 Test Sample S/N 1# Hardware Version V3.0 Software Version V4.9.109 Modulation GFSK Operating Frequency Range 2402-2480MHz Number of Channels 40 Channels Antenna Type Metal Antenna Antenna Gain 3.36 dBi Power Supply DC 3.8V from battery DC 5V from Charging Dock Temperature Range -20°C ~ 60°C Note: for more details, please refer to the User’s manual of the EUT. Report No. ENS2512190252W00102R Page 6 of 54 Ver.1.0 3 SUMMARY OF TEST RESULT FCC Part Clause Test Parameter Verdict Remark 15.247(a)(2) DTS (6dB) Bandwidth PASS 15.247(b)(3) Maximum Peak Conducted O…
Text truncated - open the document above for the full version.
Report No. ENS2512190252W00102R Page 32 of 54 Ver.1.0 2.4GHz_2M-Ant1-2402-0~Reference-PASS 2.4GHz_2M-Ant1-2402-30~1000-PASS 2.4GHz_2M-Ant1-2402-1000~26500-PASS Report No. ENS2512190252W00102R Page 33 of 54 Ver.1.0 2.4GHz_2M-Ant1-2440-0~Reference-PASS 2.4GHz_2M-Ant1-2440-30~1000-PASS 2.4GHz_2M-Ant1-2440-1000~26500-PASS Report No. ENS2512190252W00102R Page 34 of 54 Ver.1.0 2.4GHz_2M-Ant1-2480-0~Reference-PASS 2.4GHz_2M-Ant1-2480-30~1000-PASS 2.4GHz_2M-Ant1-2480-1000~26500-PASS Report No. ENS2512190252W00102R Page 35 of 54 Ver.1.0 8.5 RADIATED SPURIOUS EMISSION 8.5.1 Applicable Standard According to FCC Part 15.247(d) and 15.209 and KDB 558074 D01 15.247 Meas Guidance v05r02 8.5.2 Conformance Limit According to FCC Part 15.247(d): radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). According to FCC Part15.205, Restricted bands MHz MHz MHz GHz 0.090-0.110 16.42-16.423 399.9-410 4.5-5.15 0.495-0.505 16.69475-16.69525 608-614 5.35-5.46 2.1735-2.1905 16.80425-16.80475 960-1240 7.25-7.75 4.125-4.128 25.5-25.67 1300-1427 8.025-8.5 4.17725-4.17775 37.5-38.25 1435-1626.5 9.0-9.2 4.20725-4.20775 73-74.6 1645.5-1646.5 9.3-9.5 6.215-6.218 74.8-75.2 1660-1710 10.6-12.7 6.26775-6.26825 123-138 2200-2300 14.47-14.5 8.291-8.294 149.9-150.05 2310-2390 15.35-16.2 8.362-8.366 156.52475-156.52525 2483.5-2500 17.7-21.4 8.37625-8.38675 156.7-156.9 2690-2900 22.01-23.12 8.41425-8.41475 162.0125-167.17 3260-3267 23.6-24.0 12.29-12.293 167.72-173.2 3332-3339 31.2-31.8 12.51975-12.52025 240-285 3345.8-3358 36.43-36.5 12.57675-12.57725 322-335.4 3600-4400 Above 38.6 13.36-13.41 According to FCC Part15.205, the level of any transmitter spurious emission in Restricted bands shall not exceed the level of the emission specified in the following table Restricted Frequenc y(MHz) Field Strength (μV/m) Field Strength (dBμV/m) Measurement Distance 0.009-0.490 2400/F(KHz) 20 log (uV/m) 300 0.490-1.705 24000/F(KHz) 20 log (uV/m) 30 1.705-30 30 29.5 30 30-88 100 40 3 88-216 150 43.5 3 216-960 200 46 3 Above 960 500 54 3 8.5.3 Test Configuration Test according to clause 7.2 radio frequency test setup 2 8.5.4 Test Procedure This test is required for any spurious emission that falls in a Restricted Band, as defined in Section 15.205. It must be performed with the highest gain of each type of antenna proposed for use with the EUT. Use the following spectrum analyzer settings: The EUT was placed on a turn table which is 0.8m above ground plane. Maximum procedure was performed on the highest emissions to ensure EUT compliance. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f ≥ 1 GHz(1GHz to 25GHz), 100 kHz for f < 1 GHz(30MHz to 1GHz) VBW ≥ RBW Sweep = auto Detector function = peak Trace = max hold Report No. ENS2512190252W00102R Page 36 of 54 Ver.1.0 Follow the guidelines in ANSI C63.10 with respect to maximizing the emission by rotating the EUT, measuring the emission while the EUT is situated in three orthogonal planes (if appropriate), adjusting the measurement antenna height and polarization, etc. A pre-amp and a high pass filter are required for this test, in order to provide the measuring system with sufficient sensitivity. Allow the trace to stabilize. The peak reading of the emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak field strength, which must comply with the limit specified in Section 15.35(b). Submit this data. Now set the VBW to 10 Hz, while maintaining all of the other instrument settings. This peak level, once corrected, must comply with the limit specified in Section 15.209. If the dwell time per channel of the hopping signal is less than 100 ms, then the reading obtained with the 10 Hz VBW may be further adjusted by a “duty cycle correction factor”, derived from 20log(dwell time/100 ms), in an effort to demonstrate compliance with the 15.209 limit. Submit this data. Repeat above procedures until all frequency measured was complete. 8.5.5 Test Results Pass Temperature: 25° C Relative Humidity: 60% ATM Pressure: 1011 mbar Spurious Emission below 30MHz (9KHz to 30MHz) Freq. (MHz) Ant.Pol. Emission Level (dBuV/m) Limit 3m(dBuV/m) Over(dB) H/V PK AV PK AV PK AV -- -- -- -- -- -- -- -- Note: the amplitude of spurious emission that is attenuated by more than 20dB below the permissible limit has no need to be reported. Distance extrapolation factor =40log(Specific distance/ test distance)( dB); Limit line=Specific limits(dBuV) + distance extrapolation factor Report No. ENS2512190252W00102R Page 37 of 54 Ver.1.0 Spurious Emission Above 1GHz (1GHz to 25GHz) 2.4GHz mode have been tested, and the worst result was report as below: Test mode: 2.4GHz(1M) Frequency: Channel 0: 2402MHz Freq. (MHz) Ant.Pol. Emission Level (dBuV/m) Limit 3m(dBuV/m) Over(dB) Detector 7205.62 V 56.62 74.00 17.38 peak 11488.1 V 63.42 74.00 10.58 peak 17853.7 V 68.32 74.00 5.68 peak 7205.99 V 48.20 54.00 5.80 AVG 11488.1 V 45.26 54.00 8.74 AVG 17853.7 V 47.23 54.00 6.77 AVG 7393.12 H 55.55 74.00 18.45 peak 11358.7 H 63.36 74.00 10.64 peak 16908.7 H 68.89 74.00 5.11 peak 7393.12 H 38.31 54.00 15.69 AVG 11358.7 H 44.44 54.00 9.56 AVG 16908.7 H 48.54 54.00 5.46 AVG Test mode: 2.4GHz(1M) Frequency: Channel 19: 2440MHz Freq. (MHz) Ant.Pol. Emission Level(dBuV/m) Limit 3m(dBuV/m) Over(dB) Detector 7320 V 56.26 74.00 17.74 peak 11330.6 V 63.58 74.00 10.42 peak 17640 V 68.90 74.00 5.10 peak 7319.46 V 47.63 54.00 6.37 AVG 11330.6 V 44.82 54.00 9.18 AVG 17640 V 49.64 54.00 4.36 AVG 8341.87 H 59.66 74.00 14.34 peak 11341.8 H 63.51 74.00 10.49 peak 17956.8 H 68.66 74.00 5.34 peak 8341.87 H 42.44 54.00 11.56 AVG 11341.8 H 44.74 54.00 9.26 AVG 17956.8 H 50.19 54.00 3.81 AVG Report No. ENS2512190252W00102R Page 38 of 54 Ver.1.0 Test mode: 2.4GHz(1M) Frequency: Channel 39: 2480MHz Freq. (MHz) Ant.Pol. Emission Level (dBuV/m) Limit 3m(dBuV/m) Over(dB) Detector 74…
Text truncated - open the document above for the full version.
2261 Market Street, STE 22843 · San Francisco · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.10 mW |

Ring
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter