2BQEM-S5Tablet

Shenzhen Good Energy Technology CO., ltd

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 16, 2025
Application Purpose
Original Equipment
Equipment Note
Tablet
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Good Energy Technology CO., ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Good Energy Technology CO., ltd 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Good Energy Technology CO., ltd Address: Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Product Name: Tablet FCC ID: 2BQEM-S5 Model(s): S5 2.911(d)(5)(i) Equipment Type We, [Shenzhen Good Energy Technology CO., ltd] (“the applicant”) certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Wenyuan Huang Date: Dec. 04, 2025 Title: manager Company name: Shenzhen Good Energy Technology CO., ltd Signature: NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Good Energy Technology CO., ltd 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Good Energy Technology CO., ltd Address: Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Product Name: Tablet FCC ID: 2BQEM-S5 Model(s): S5 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Good Energy Technology CO., ltd] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to §1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Wenyuan Huang Date: Dec. 04, 2025 Title: manager Company name: Shenzhen Good Energy Technology CO., ltd Signature: NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Good Energy Technology CO., ltd 2.911 (d)(7)USA Agent v1.5 Section 2.911(d)(7) USA Agent for Service of Process Company name: Shenzhen Good Energy Technology CO., ltd Address: Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Product Name: Tablet FCC ID: 2BQEM-S5 Model(s): S5 2.911(d)(7) USA Designated Agent for Service of Process We, [Shenzhen Good Energy Technology CO., ltd] designate [TRANS-PAC CHINA LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA A g Compa TRAN S Address 3715 S United S FCC R e Contact Telepho Email: i Signat u Title: M Date: D NOTE 1 process Referenc https://w ty-threat She gent ny name: S-PAC CHIN s: 182nd Str e States egistration N t Name:Lisa one No: +1 nfo@trans - ure: anage r Dec. 04, 202 : An applican . ce; Federal Re www.federalre ts-to-the-com enzhen NA LLC eet, C120 S Number (FR a Lee 81881805 3 -pac.com 25 nt located in egister docume egister.gov/d mmunications Good E Seatac,WA 9 RN): 003639 38 the United S ent 2022-2826 documents/2 s-supply-cha Energy T 98188 94526 Ap Co Te A d Ind Co Dis FR F C Co Te Em Si g Ti t Da States may d 63 published o 2023/02/06/2 ain-through-th Technolo pplicant ompany nam echnology C ddress: Room dustrial Park ommunity,Ba strict,Shenz RN:003718 CC Grantee ontact Name elephone No mail: Huangw gnature: tle: manager ate: Dec. 04 designate itse on 02/06/23 022-28263/p he ogy CO. 2. me: Shenzhe O., ltd m 901,Office k,8 Chengxin aolong Subd hen, China 81344 Code: 2BQ E e: Wenyuan o: 18675830 wenyuan@o r 4, 2025 elf as the age protecting-ag , ltd .911 (d)(7)USA en Good Ene e Building,Y n Road Bao district,Long EM Huang 115 otvoc.net ent for servic gainst-nationa Agent v1.5 ergy Yasen long gang ce of al-securi

Cover Letter(s)

Shenzhen Good Energy Technology CO., ltd Agent Authorization Company: Shenzhen Good Energy Technology CO., ltd Address: Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Product Name: Tablet Model Number(s): S5 Product Description: Tablet We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Dec. 04, 2025 Name: Wenyuan Huang Title: manager Company: Shenzhen Good Energy Technology CO., ltd

Cover Letter(s)

Shenzhen Good Energy Technology CO., ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Dec. 04, 2025 Subject; Request for Confidentiality FCC ID: 2BQEM-S5 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Wenyuan Huang Title: manager

ID Label/Location Info

FCC ID LABEL: Ca. 15mm x 30mm Label Location FCC ID: 2BQEM‐S5

RF Exposure Info

FCC RF Exposure EUT Description: Tablet Model No.: S5 FCC ID: 2BQEM-S5 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P= Maximum turn‐up power in mw D= Min. test separation distance in mm 2. Test Result of RF Expos ure Evaluation Frequency (MHz) Output power (dBm) Tune Up Power (dBm) Max Tune Up power (mW) Min test separation distance (mm) ResultLimit SAR T est Exclusion 2412 7.95 7±1(8) 6.310 5 1.9603.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2511176192-E, antenna gain=1.49dBi Per KDB 447498 D0 1, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 1.960 which is ≤ 3, RF Exposure testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f (GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm

Test Report

地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435 FAX:0755-23203435 第1页 共7页 天线 规格书 Antenna Sample Confirmation From 供应商名称 Vendor Name 深圳市艾汇科技有限公司 ShenZhen Aihui Technology Co.,Ltd 客户名称 Customer Name 明致MZ 样品名称 Sample Name M55 产品型号 Part Number 样品规格 Specification 三合一天线:丝印:M55-WGB-AH 检验项目 Inspection Item 性能测试 Performance 外观检查 Total Appearance 结构 structure 其它 Others 检验结果 Inspection Result 备注 Remark 品质审核 QA Audit 以下由客户填写 The following are filled by Customer 客户意见 Customer Evaluation 客户签字/盖章 Signation/ Chapter by Customer 日期/date:2025.08.18 第2页 共7页 Antenna Test Report 测试单位: 深圳市艾汇科技有限公司 Test by: ShenZhen Aihui Technology Co.,Ltd 材料 Material FPC+同轴线 天线类型 Antenna Type MonopoleType 极化方式 Polarization mode Linear 应用场景 Application 工作频段 Band 2.4G WiFi VSWR≤2 功率 Power Max:2W 阻抗 Impedance 50Ω 增益 dBi 1.49dBi 测试设备 Test Equipment HPE5071C、Shielding Room、3D automatic turntable Antenna Description:: 1. Grounding processing and picture description: no 2. Need to change the motherboard to match: no Test voltage: 3.6V, check the antenna contact is good before testing. The RF cable of the integrated tester is kept in a natural state and can not be curled. Specification:test the specified power level, all indicators must conform to the specifications. 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435 FAX:0755-23203435 第3页 共7页 1、测试制具 Testing equipment 2、天线匹配电路 Antenna matching circuit 3、S11测试 Testing 3.0 S11 测试方法说明 Test Method Description 4、天线无源效率和增益Passive efficiency and gain of antenna 5、暗室测试设备和数据Darkroom testing equipment and data 5.0 测试设备Test equipment 5.1 有源测试数据Active test data 6、天线环境处理Antenna environment processing 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435 FAX:0755-23203435 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435 FAX:0755-23203435 第4页 共7页 1、测试制具Testing equipment 目的:尽可能准确地测试天线的无源参数。 制作方法:手机制具是用一根50 欧姆的同轴电缆,一端连在手机主板的匹配电 路后端(射频测试孔前端)的测试点上,另一端连接SMA 接头。示意图如下: Purpose: To test the passive parameters of the antenna as accurately as possible. Production method: The mobile phone tool is made by using a 50 ohm coaxial cable, with one end connected to the testing point at the back end of the matching circuit (front end of the RF test hole) of the mobile phone motherboard, and the other end connected to an SMA connector. The schematic diagram is as follows: 2、天线匹配电路Antenna matching circuit 修改点/Modify E01E02E03 NoNoNo 第5页 共7页 3. S11 测试test 3.0 S11 测试方法说明Test Method Description 测试设备test equipment :网络分析仪(E5071C)Network analyzer (E5071C) 测试方法test method:用一根 50 欧姆 CABLE 电缆从仪器测试端口导出,使用校准件 校准后连接手机制具的SMA 接头,记录相关频点对应的回波损耗和驻波比。 Export a 50 ohm CABLE cable from the instrument test port, calibrate it with a calibration piece, and connect it to the SMA connector of the mobile phone fixture. Record the corresponding return loss and standing wave ratio at the relevant frequency points. 4、暗室测试设备和数据Darkroom testing equipment and data 6.0 测试设备test equipment 测试系统test system: 屏蔽暗室Shielded darkroom 测试环境test environment: 温度22°C±3°C,湿度 50%±15%Temperature 22 °C± 3 °C, humidity 50% ± 15% 测试设备test equipment: 测试无源数据时, 使用网络分析仪 AgilentE5071C When testing passive data, use the network analyzer Agilent E5071C 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋 402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL: 0755-23203435 FAX:0755-23203435 第6页 共7页 5.1 天线无源数据Passive antenna data 5.2 天线SWR /Antenna SWR 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋 402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL: 0755-23203435 FAX:0755-23203435 第7页 共7页 6.天线量产指标Antenna mass production indicators 天线量产时,以驻波比作为量产测试标准。根据项目本身的差异 ,给出如下标准: When producing antennas, the standing wave ratio is used as the production testing standard. Based on the differences in the project itself, the following standards are given: 频率frequency 量产标准Mass production standards 2400 MHZ -2500MHZ VSWR<VSWR+0.5 5100 MHZ -5850MHZ VSWR<VSWR+0.5 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435FAX:0755-23203435 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435FAX:0755-23203435 地址:深圳市宝安区西乡固戍南昌社区钜鑫科技产业园C栋402 402, Building C, Juxin Technology Industrial Park, Gushu Nanchang Community, Xixiang, Bao'an District, Shenzhen TEL:0755-23203435 FAX:0755-23203435 7.结构图纸

Test Report

Page 1 of 72 Report No.: HK2511176192-E FCC Test Report Test Report On Behalf of Shenzhen Good Energy Technology CO., ltd For Tablet Model No.: S5 FCC ID: 2BQEM-S5 Prepared For: Shenzhen Good Energy Technology CO., ltd Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Nov. 17, 2025 ~ Dec. 04, 2025 Date of Report: Dec. 04, 2025 Report Number: HK2511176192-E Page 2 of 72 Report No.: HK2511176192-E Test Result Certification Applicant’s Name .................. : Shenzhen Good Energy Technology CO., ltd Address .................................. : Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Manufacturer's Name ........... : Shenzhen Good Energy Technology CO., ltd Address .................................. : Room 901,Office Building,Yasen Industrial Park,8 Chengxin Road Baolong Community,Baolong Subdistrict,Longgang District,Shenzhen, China Product Description Trade Mark ............................. : N/A Product Name ......................... : Tablet Model and/or Type Reference : S5 Standards ............................... : FCC Rules and Regulations Part 15 Subpart C Section 15.247 ANSI C63.10: 2020 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Nov. 17, 2025 ~ Dec. 04, 2025 Date of Issue ........................................... : Dec. 04, 2025 Test Result ............................................... : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 72 Report No.: HK2511176192-E Table of Contents 1. Summary ................................................................................................... 5 1.1 Test Procedures and Results ........................................................................................................... 5 1.2 Information of the Test Laboratory ................................................................................................. 5 1.3 Measurement Uncertainty ................................................................................................................ 6 2. EUT Description ........................................................................................ 7 2.1 General Description of EUT ............................................................................................................. 7 2.2 Carrier Frequency of Channels ........................................................................................................ 8 2.3 Operation of EUT during Testing ..................................................................................................... 8 2.4 Description of Test Setup ................................................................................................................. 9 2.5 Description of Support Units ......................................................................................................... 10 3. General Information ................................................................................ 11 3.1 Test Environment and Mode .......................................................................................................... 11 4. Test Results and Measurement Data .................................................... 13 4.1 AC Conducted Emission ................................................................................................................ 13 4.2 Maximum Peak Conducted Output Power .................................................................................... 17 4.3 Emission Bandwidth ....................................................................................................................... 20 4.4 Power Spectral Density .................................................................................................................. 26 4.5 Conducted Band Edge and Spurious Emission Measurement .................................................. 33 4.6 Radiated Spurious Emission Measurement ................................................................................. 43 4.7 Antenna Requirement ..................................................................................................................... 69 5. Test Setup Photos of the EUT ............................................................... 70 6. Photos of the EUT ................................................................................... 72 Page 4 of 72 Report No.: HK2511176192-E ** Modified History ** Revision Description Issued Date Remark Revision 1.0 Initial Test Report Release Dec. 04, 2025 Jason Zhou Page 5 of 72 Report No.: HK2511176192-E 1. Summary 1.1 Test Procedures and Results Requirement CFR 47 Section Result Antenna Requirement §15.203/§15.247(b)(4) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247(b)(3) PASS 6dB Emission Bandwidth §15.247(a)(2) PASS Power Spectral Density §15.247(e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 Information o…

Text truncated - open the document above for the full version.

Test Report

Page 43 of 72 Report No.: HK2511176192-E 4.6 Radiated Spurious Emission Measurement Test Specification Test Requirement: FCC Part15 C Section 15.209 Test Method: ANSI C63.10: 2020 Frequency Range: 9 kHz to 25 GHz Measurement Distance: 3 m Antenna Polarization: Horizontal & Vertical Operation Mode: Transmitting mode with modulation Receiver Setup: Frequency Detector RBW VBW Remark 9kHz- 150kHzQuasi-peak200Hz 1kHz Quasi-peak Value 150kHz- 30MHz Quasi-peak9kHz 30kHz Quasi-peak Value 30MHz-1GHzQuasi-peak120KHz300KHz Quasi-peak Value Above 1GHz Peak 1MHz 3MHz Peak Value Peak 1MHz 10Hz Average Value Limit: Frequency Field Strength (microvolts/meter) Measurement Distance (meters) 0.009-0.490 2400/F(KHz) 300 0.490-1.705 24000/F(KHz) 30 1.705-30 30 30 30-88 100 3 88-216 150 3 216-960 200 3 Above 960 500 3 Frequency Field Strength (microvolts/meter) Measurement Distance (meters) Detector Above 1GHz 500 3 Average 5000 3 Peak Test Setup: For radiated emissions below 30MHz Page 44 of 72 Report No.: HK2511176192-E 30MHz to 1GHz Above 1GHz Test Procedure: 1. For the radiated emission test below 1GHz: The EUT was placed on a turntable with 0.8 meter above ground. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the top of a variable height antenna tower. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high PASS filter are used for the test in order to get better signal level. 2. For the radiated emission test above 1GHz: Place the measurement antenna on a turntable with 1.5 meter above ground, which is away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. Page 45 of 72 Report No.: HK2511176192-E The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. 3. Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level 4. For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. 5. Use the following spectrum analyzer settings: (1) Span shall wide enough to fully capture the emission being measured; (2) Set RBW=120 kHz for f < 1 GHz; VBW ≥RBW; Sweep = auto; Detector function = peak; Trace = max hold; (3) Set RBW = 1 MHz, VBW= 3MHz for f 1 GHz for peak measurement. 6.For average measurement: VBW = 10 Hz, when duty cycle is no less than 98 percent.VBW ≥ 1/T, when duty cycle is less than 98 percent where T is the minimum transmission duration over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Test Results: PASS Page 46 of 72 Report No.: HK2511176192-E Test Instruments Radiated Emission Test Site (966) Name of Equipment Manufacturer Model Serial Number Calibration Date Calibration Due Spectrum analyzer Agilent N9020A HKE-025 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer Agilent N9020A HKE-117 Feb. 19, 2025 Feb. 18, 2026 Spectrum analyzer R&S FSV3044 HKE-126 Feb. 19, 2025 Feb. 18, 2026 Preamplifier EMCI EMC051845SHKE-006 Feb. 19, 2025 Feb. 18, 2026 Preamplifier Schwarzbeck BBV 9743 HKE-016 Feb. 19, 2025 Feb. 18, 2026 Preamplifier A.H. Systems SAS-574 HKE-182 Feb. 19, 2025 Feb. 18, 2026 6dB Attenuator Pasternack 6db HKE-184 Feb. 19, 2025 Feb. 18, 2026 EMI Test Receiver Rohde & Schwarz ESR-7 HKE-010 Feb. 19, 2025 Feb. 18, 2026 Broadband Antenna Schwarzbeck VULB9168 HKE-167 Feb. 21, 2024 Feb. 20, 2026 Loop Antenna COM-POWER AL-130R HKE-014 Feb. 21, 2024 Feb. 20, 2026 Horn Antenna Schewarzbeck 9120D HKE-013 Feb. 21, 2024 Feb. 20, 2026 EMI Test Software Tonscend JS32-RE 5.0.0HKE-082 / / RSE Test Software Tonscend JS36-RSE 5.0.0 HKE-184 / / Page 47 of 72 Report No.: HK2511176192-E Test Data All the test modes completed for test. Only the worst result was reported as below: Below 1GHz Test Results: Antenna polarity: Horizontal Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level Page 48 of 72 Report No.: HK2511176192-E Antenna polarity: Vertical Remark: Factor = Cable loss + Antenna factor + Attenuator – Preamplifier; Level = Reading + Factor; Margin = Limit – Level Harmonics and Spurious Emissions Frequency Range (9kHz-30MHz) Frequency (MHz) Level@3m (dBμV/m) Limit@3m (dBμV/m) -- -- -- -- -- -- -- -- -- -- -- -- Note:1. Emission Level=Reading+ Cable loss-Antenna factor-Amp factor. 2. The emission levels are 20 dB below the limit value, which are not reported. It is deemed to comply with the requirement. Page 49 of 72 Report No.: HK2511176192-E Above 1GHz Radiated Emission Test Operation Mode: 802.11b Mode with 2.4G TX CH Low Horizontal: FrequencyReading ResultFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 482450.1-3.6446.467427.54peak 482440.4-3.6436.765417.24AVG 723652.06-0.9551.117422.89peak 723641.35-0.9540.45413.6AVG Remark: Factor = Cable loss + Antenna factor + Attenuator - Preamplifier; Level = Reading + Factor; Margin = Limit - Level. Detector Type Vertical: FrequencyReading ResultFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 482450.14-3.6446.57427.5peak 482442.07-3.6438.435415.57AVG 723651.51-0.9550.567423.44peak 723640.33-0.9539.385414.62A…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Model:S5 Radiated Emission AC Conducted Emission RF Conducted Emission

Contact Information

Applicant

Wenyuan Huang
[email protected]Fax: N/A

Technical Contact

TRANS-PAC CHINA LLC
[email protected]

United States

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz6.24 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth.