Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INSTRUCTION MANUAL Electronic Level Gauge ELG 487-080-4/005_EN_ ELG-Ex Date: 13.06.2025 Index-No.: 3598 Page : 1 / 17 SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / GERMANY reserves the possibility at any time to change technical contents without previous consent. For more information contact: +49 6462 9392-0 or [email protected] S U M M A R Y 1. DESCRIPTION ................................................................................................................................................2-4 2. GENERAL SAFETY REQUIREMENTS ......................................................................................................... 5 3. TECHNICAL DATA .......................................................................................................................................6-7 4. INSTALLATION AND HANDLING INSTRUCTIONS .............................................................................8-9 5. HANDLING DIMES ELG ..........................................................................................................................10-13 6. MAINTENANCE .............................................................................................................................................. 14 7. GENERAL CONDITIONS .............................................................................................................................. 14 8. MANAGING FAILURES IN GENERAL....................................................................................................... 14 9. ENVIRONMENTAL ASPECT AT DISPOSAL ............................................................................................ 14 ONLY THOSE PERSONS WHO HAVE READ THESE TECHNICAL INSTRUCTIONS THOROUGHLY AND UNDERSTAND THEM COMPLETELY SHALL BE AUTHORIZED TO USE THIS PRODUCT. IMPORTANT NOTICE If this product is being purchased or used for incorporation into another product (for example, a compressed gas valve for incorporation into a compressed gas cylinder), then SRG Schulz + Rackow Gastechnik GmbH reminds the end product manufacturer that any and all product user warning, instructions or product labels are the responsibility of the end product manufacturer. The following standards do apply: ATEX: EN IEC 60079-0: 2018 EN IEC 60079-11: 2012 Industrial: ANSI/ISA-61010-1:2012 C22.2 No.61010-1:2012 UL 565 EN13799 HazLoc: UL-60079-0:2019 UL-60079-11: 2014 C22.2 No.60079-0: 2019 C22.2 No.60079-11:2014 INSTRUCTION MANUAL Electronic Level Gauge ELG 487-080-4/005_EN_ ELG-Ex Date: 13.06.2025 Index-No.: 3598 Page : 2 / 17 SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / GERMANY reserves the possibility at any time to change technical contents without previous consent. For more information contact: +49 6462 9392-0 or [email protected] C O N T E N T 1. DESCRIPTION The Electronic Level Gauge ELG is intended and approved for installation on liquid fuel tanks and tanks or cylinders for liquified gases like propane/butane (LPG) or similar. The device comes complete with Display or optionally as Sensor only, to be operated with dedicated and approved third-party electronics. The standard ELG-Display includes a replaceable battery for autonomous operation and provides a ratiometric voltage output for remote reading, telemetry or control purposes. It communicates digitally with the Level Sensor, integrated at the valve or sensor featuring a capacitive level probe. The ELG-BLE Display provides BLE-functionality instead of a wired remote connection. It has a non-user replaceable battery inside. Type Designations ATEX (EU): Sensor Only ELG Electronic Level Gauge; Sensor with Display Pos. Level Sensor, incl. ATEX-marking Display incl. ATEX-marking 1 487-100-1 1” NPT thread, LPG 487-102-2 or 487-112-2 (BLE) 2 487-110-1 1¼” NPT thread, LPG 3 487-120-1 ¾” NPT thread, LPG 4 487-130-1 Junior Flange, LPG, Flat seal 5 487-131-1 Junior Flange, LPG, O-ring seal 6 487-140-1 Senior Flange, LPG 7 487-400-1 G 1½” NPT thread, refined Fuels 8 487-430-1 Junior Flange, refined Fuels 9 462-100-1 Smart Valve ¾” NGT / CGA xxx 10 462-110-1 Smart Valve ¾” NGT / CGA xxx 11 462-120-1 Smart Valve 25E / G.xx 12 462-150-1 Smart Valve ¾” NGT / CGA xxx, FLLG, PTP INSTRUCTION MANUAL Electronic Level Gauge ELG 487-080-4/005_EN_ ELG-Ex Date: 13.06.2025 Index-No.: 3598 Page : 3 / 17 SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / GERMANY reserves the possibility at any time to change technical contents without previous consent. For more information contact: +49 6462 9392-0 or [email protected] HazLoc (NA): Sensor Only ELG Electronic Level Gauge; Sensor with Display Pos. Level Sensor, incl. HazLoc-marking Display incl. HazLoc-marking 1 487-100-1 1” NPT thread, LPG 487-103-2 or 487-113-2 (BLE) 2 487-110-1 1¼” NPT thread, LPG 3 487-120-1 ¾” NPT thread, LPG 4 487-130-1 Junior Flange, LPG, Flat seal 5 487-131-1 Junior Flange, LPG, O-ring seal 6 487-140-1 Senior Flange, LPG 7 487-410-1 1½” NPT thread, refined Fuels 8 487-420-1 2” NPT-F thread, refined Fuels 9 487-430-1 Junior Flange, refined Fuels 10 487-440-1 Smart Valve ¾” NPT thread, refined Fuels 11 462-100-1 Smart Valve ¾” NGT / CGA xxx 12 462-110-1 Smart Valve ¾” NGT / CGA xxx 13 462-150-1 Smart Valve ¾” NGT / CGA xxx, FLLG, PTP This PRODUCT is not intended for any other installation or purpose. If the product user has any question regarding this PRODUCT’s proper application or purpose, the product user should call +49 6462 9392-0. Any non-approved use or application and/or any non-approved modification of the PRODUCT or its use or application may result in a serious accident or personal injury for which SRG Schulz + Rackow Gastechnik GmbH will not be responsible. SRG Schulz + Rackow Gastechnik GmbH cannot be held responsible for an inappropriate use of the product. The supplier of the final equipment is responsible for the homologation of the system. SRG Schulz + Rackow Gastechnik GmbH cannot be held responsible of the latter’s negligence. Recommendations of SRG Schulz + …
Text truncated - open the document above for the full version.
SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / ALLEMAGNE se réserve la possibilité de modifier à tout moment le contenu technique sans accord préalable. Pour plus d'informations, veuillez contacter +49 6462 9392-0 ou [email protected] MANUEL D’INSTRUCTIONS Indicateur de niveau électronique ELG 487-080-4/005_FR_ ELG-Ex Date: 27.10.2025 Index-N°: 3638 Page: 1 / 17 1. DESCRIPTION ................................................................................................................................ 2-5 2. CONSIGNES GÉNÉRALES DE SÉCURITÉ .................................................................................... 5-6 3. DONNÉES TECHNIQUES ............................................................................................................... 7-9 4. INSTRUCTIONS D'INSTALLATION ET DE MANIPULATION ..................................................... 10-12 5. FONCTIONNALITES DE L’AFFICHEUR ELG ........................................................................... 13-16 6. ENTRETIEN ..................................................................................................................................... 17 7. CONDITIONS GÉNÉRALES ............................................................................................................ 17 8. DÉFAILLANCES GÉNÉRALES ....................................................................................................... 17 9. FIN DE VIE / RECYCLAGE ............................................................................................................ 17 SEULES LES PERSONNES AYANT LU ATTENTIVEMENT CES INSTRUCTIONS TECHNIQUES ET LES AYANT COMPRISES DANS LEUR INTÉGRALITÉ SONT AUTORISÉES À UTILISER CE PRODUIT. TABLE DES MATIERES AVIS IMPORTANT Si ce produit est acheté ou utilisé pour être incorporé dans un autre produit (par exemple, une vanne de gaz comprimé destinée à être incorporée dans une bouteille de gaz comprimé), SRG Schulz + Rackow Gastechnik GmbH rappelle au fabricant du produit final que tous les avertissements, instructions ou étiquettes d'utilisation du produit relèvent de la responsabilité du fabricant du produit final. Les normes suivantes s'appliquent : ATEX : EN IEC 60079-0 : 2018 EN IEC 60079-11 : 2012 Industrielles : ANSI/ISA-61010-1 : 2012 C22.2 No.61010-1 : 2012 UL 565 EN13799 HazLoc : UL-60079-0 : 2019 UL-60079-11 : 2014 C22.2 No.60079-0 : 2019 C22.2 No.60079-11 : 2014 SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / ALLEMAGNE se réserve la possibilité de modifier à tout moment le contenu technique sans accord préalable. Pour plus d'informations, veuillez contacter +49 6462 9392-0 ou [email protected] MANUEL D’INSTRUCTIONS Indicateur de niveau électronique ELG 487-080-4/005_FR_ ELG-Ex Date: 27.10.2025 Index-N°: 3638 Page: 2 / 17 C O N T E N U 1. DESCRIPTION L’Afficheur de niveau électronique ELG est conçue et approuvée pour être installée sur les réservoirs de carburant liquide et les réservoirs ou les bouteilles de gaz liquéfiés tels que le propane/butane (GPL) ou similaires. L'appareil est livré avec un afficheur ou optionnellement en tant que capteur seul, à faire fonctionner avec une électronique tierce dédiée et approuvée. L'afficheur comprend une batterie remplaçable pour un fonctionnement autonome et fournit une sortie de tension ratio métrique pour la lecture à distance, la télémétrie ou le contrôle. Il communique numériquement avec le capteur de niveau, intégré à la vanne ou capteur avec sonde de niveau capacitive. L’indicateur de niveau électrique ELG-BLE dispose de la fonctionnalité BLE à la place d’une connexion par câble. L’afficheur contient une batterie interne non remplaçable. Désignation des types ATEX (EU) Capteur seul Indicateur de niveau électronique ELG ; Capteur avec afficheur Pos. Capteur de niveau, marquage ATEX inclus Afficheur, marquage ATEX inclus 1 487-100-1 Filet 1” NPT, GPL 487-102-2 ou 487-112-2 (BLE) 2 487-110-1 Filet 1¼” NPT, GPL 3 487-120-1 Filet ¾” NPT, GPL 4 487-130-1 Flange Junior, GPL, joint plat 5 487-131-1 Flange Junior, GPL, joint torique 6 487-140-1 Flange Senior, GPL 7 487-400-1 Filet G 1½”, Carburants raffiné 8 487-430-1 Flange Junior, Carburants raffiné 9 462-100-1 Robinet intelligent ¾” NGT/ CGA xxx 10 462-110-1 Robinet intelligent ¾” NGT/ CGA xxx 11 462-120-1 Robinet intelligent 25E/ G.xx 12 462-150-1 Robinet intelligent ¾” NGT/ CGA xxx, Jauge point haut et Port de test de pression SRG Schulz + Rackow Gastechnik GmbH / 35075 Gladenbach / ALLEMAGNE se réserve la possibilité de modifier à tout moment le contenu technique sans accord préalable. Pour plus d'informations, veuillez contacter +49 6462 9392-0 ou [email protected] MANUEL D’INSTRUCTIONS Indicateur de niveau électronique ELG 487-080-4/005_FR_ ELG-Ex Date: 27.10.2025 Index-N°: 3638 Page: 3 / 17 HazLoc (NA): Capteur seul Indicateur de niveau électronique ELG ; Capteur avec afficheur Pos. Capteur de niveau, marquage HazLoc inclus Afficheur, marquage HazLoc inclus 1 487-100-1 Filet 1” NPT, GPL 487-103-2 ou 487-113-2 (BLE) 2 487-110-1 Filet 1¼” NPT, GPL 3 487-120-1 Filet ¾” NPT, GPL 4 487-130-1 Flange Junior, GPL, joint plat 5 487-131-1 Flange Junior, GPL, joint torique 6 487-140-1 Flange Senior, GPL 7 487-410-1 Filet 1½” NPT, Carburants raffiné 8 487-420-1 Filet 2” NPT-F, Carburants raffiné 9 487-430-1 Flange Junior, Carburants raffiné 10 487-440-1 Filet ¾” NPT, Carburants raffiné 11 462-100-1 Robinet intelligent ¾” NGT/ CGA xxx 12 462-110-1 Robinet intelligent ¾” NGT/ CGA xxx 13 462-150-1 Robinet intelligent ¾” NGT/ CGA xxx, Jauge point haut et Port de test de pression Ce PRODUIT n'est pas destiné à une autre installation ou à un autre usage. Si l'utilisateur du produit a des questions concernant l'application ou l'utilisation correcte de ce PRODUIT, il doit appeler le +49 6462 9392-0. Toute utilisation ou application non approuvée et/ou toute modification non approuvée du PRODUIT ou de son utilisation ou application peut entraîner un accident grave ou des blessures corporell…
Text truncated - open the document above for the full version.
Annex A101 - Photographs No. 1-9045-24-01-01_TR1-A101-R01 July 10, 2025 DescriptionExternal photos of EUT This document is electronically signed and valid without handwritten signature. Public keys for verifcation of the electronic signatures can be requested at the testing laboratory. Andreas Curette Lab Manager Radio Labs authorized by cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 1 of 10 Photo 1 Photo 2 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 2 of 10 Photo 3 Photo 4 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 3 of 10 Photo 5 Photo 6 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 4 of 10 Photo 7 Photo 8 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 5 of 10 Photo 9 Photo 10 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 6 of 10 Photo 11 Photo 12 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 7 of 10 Photo 13 Photo 14 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 8 of 10 Photo 15 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 9 of 10 Document History End of document ReleaseApplied changesRelease date R01initial releaseJuly 10, 2025 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A101-R01 Page 10 of 10
Annex A102 - Photographs No. 1-9045-24-01-01_TR1-A102-R01 July 10, 2025 DescriptionInternal photos of EUT This document is electronically signed and valid without handwritten signature. Public keys for verifcation of the electronic signatures can be requested at the testing laboratory. Andreas Curette Lab Manager Radio Labs authorized by cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 1 of 8 Photo 1 Photo 2 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 2 of 8 Photo 3 Photo 4 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 3 of 8 Photo 5 Photo 6 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 4 of 8 Photo 7 Photo 8 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 5 of 8 Photo 9 Photo 10 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 6 of 8 Photo 11 Photo 12 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 7 of 8 Document History End of document ReleaseApplied changesRelease date R01initial releaseJuly 10, 2025 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-9045-24-01-01_TR1-A102-R01 Page 8 of 8
© cetecom advanced GmbH Page 1 of 7 TEST REPORT Test report no.: 1-9045-24-01-11_TR2-R01 RF Exposure consideration according to FCC447498D04 V1 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 ROTAREX S.A. 24 rue de Diekirch 7440 LINTGEN / LUXEMBOURG Phone: -/- Contact: René Fogen e-mail: [email protected] Manufacturer ROTAREX S.A. 24 rue de Diekirch 7440 LINTGEN / LUXEMBOURG Test Item Kind of test item: Electronic Level Gate Metering Model name: ELG BLE FCC ID: 2BQG5-ELG-BLE Frequency: 2400 MHz to 2483.5 MHz Technology: Bluetooth® LE This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-9045-24-01-11_TR2-R01 © cetecom advanced GmbH Page 2 of 7 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 MPE-Based Test Exemption ................................................................................................................. 5 4 MPE-Based Test Exemption ............................................................................................................................ 6 4.1 Detailed Description .............................................................................................................................. 6 4.2 Results ................................................................................................................................................... 7 5 Conclusion ........................................................................................................................................................ 7 Test report no.: 1-9045-24-01-11_TR2-R01 © cetecom advanced GmbH Page 3 of 7 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or incomplete product information provided by the customer. Under no circumstances does the cetecom advanced GmbH test report include any endorsement or warranty regarding the functionality, quality or performance of any other product or service provided. Under no circumstances does the cetecom advanced GmbH test report include or imply any product or service warranties from cetecom advanced GmbH, including, without limitation, any implied warranties of merchantability, fitness for purpose, or non-infringement, all of which are expressly disclaimed by cetecom advanced GmbH. All rights and remedies regarding vendor’s products and services for which cetecom advanced GmbH has prepared this test report shall be provided by the party offering such products or services and not by cetecom advanced GmbH. In no case this test report can be considered as a Letter of Approval. This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. 2.2 References Guidance Version Description 47 CFR 1.1307 Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. 47 CFR 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. 47 CFR 2.1093 Radiofrequency radiation exposure evaluation: portable devices. KDB 447498 D04 v01 Interim General RF Exposure Guidance: RF Exposure Procedures and Equipment Authorization Policies for Mobile and Portable Devices Test report no.: 1-9045-24-01-11_TR2-R01 © cetecom advanced GmbH Page 4 of 7 3 General RF Exposure Test Exemptions KDB 447498 D04 Interim General RF Exposure Guidance v01, section 2.1.1: RF exposure test exemptions provide means to obtain certification without the need of showing data (measurements, or analytical/numerical modeling) to demonstrate compliance. Hereafter, in this context, an RF source is referred to as “exem…
Text truncated - open the document above for the full version.
TEST REPORT Test report no.: 1-9045-24-01-03_TR1-R02 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 ROTAREX S.A. 24 rue de Diekirch 7440 LINTGEN / LUXEMBOURG Phone: -/- Contact: René Fogen e-mail: [email protected] Manufacturer ROTAREX S.A. 24 rue de Diekirch 7440 LINTGEN / LUXEMBOURG Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 247 Issue 4 Digital Transmission Systems, Frequency Hopping Systems and Licence-Exempt Local Area Network Devices in 902-928 MHz, 2400-2483.5 MHz, 5150-5350 MHz, and 5470-5895 MHz bands RSS - Gen Issue 5 incl. Amendment 1 & 2 Spectrum Management and Telecommunications Radio Standards Specification - General Requirements for Compliance of Radio Apparatus For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Electronic Level Gate Metering Model name: ELG BLE FCC ID: 2BQG5-ELG-BLE ISED certification number: 34689-ELGBLE Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® LE Antenna: Integrated antenna Power supply: 3.6 V DC by battery Temperature range: -40°C to +65°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Michael Dorongovski Andreas Curette Lab Manager Lab Manager Radio Labs Radio Labs Test report no.: 1-9045-24-01-03_TR1-R02 © cetecom advanced GmbH Page 2 of 38 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Sequence of testing ................................................................................................................................ 7 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ................................................................ 7 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz ............................................................... 8 7.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ................................................................ 9 7.4 Sequence of testing radiated spurious above 18 GHz .................................................................. 10 8 Description of the test setup ................................................................................................................. 11 8.1 Shielded semi anechoic chamber ................................................................................................ 12 8.2 Shielded fully anechoic chamber ................................................................................................ 13 8.3 Radiated measurements > 18 GHz .............................................................................................. 14 8.4 Conducted measurements Bluetooth system .............................................................................. 15 9 Measurement uncertainty ..................................................................................................................... 16 10 Summary of measurement results ..................................................................................................... 17 11 Additional comments ........................................................................................................................ 18 12 Measurement results ........................................................................................................................ 19 12.1 System gain ............................................................................................................................ 19 12.2 Power spectral density .....................................................................................................…
Text truncated - open the document above for the full version.
Conducted test results No.1-9045-24-01-03_TR1-A201-R01 July 10, 2025 Test Standard(s)NA - NI FCC 15.247 - NI FCC 15.247, ISED RSS247 - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Andreas Curette Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9045-24-01-03_TR1-A201-R01 Release 1 - Page 1 of 45 Table of Content NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps3 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps9 FCC 15.247 # Bandwidth 6dB DTS ~ BT LE 1 Msps17 FCC 15.247 # Peak psd DTS ~ BT LE 1 Msps22 FCC 15.247, ISED RSS247 # Bandwidth 99PCT and 20dB ~ BT LE 1 Msps27 FCC 15.247 # TX spurious conducted 20dBc ~ BT LE 1 Msps38 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9045-24-01-03_TR1-A201-R01 Release 1 - Page 2 of 45 NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps References TC start10.07.2025 08:24:53 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version6.0.2.0 Standard | Version NA | NI Method DescriptionPeak OP 3MHz/3MHz - BT LE 1 Msps Information EUT Common Settings BT Low Energy Intermodulation value N 3 Image freq. Low | Mid | High [MHz] 0 | 0 | 0 Power class2 1 Mbps supported True | TXpayload 255 | RXpayload 255 2 Mbps supported False | TXpayload 255 | RXpayload 255 Longrange S8 supported False | TXpayload 255 | RXpayload 255 Longrange S2 supportedFalse | TXpayload 255 | RXpayload 255 Signaling settings USB_RS232 | TWO | 63 | 115200 | None | S1 | None | On Signaling RF settings RF1com | 0 | 0 | On | User interaction No Equipment Signal analyzer,Rohde&Schwarz,FSV-30,1321.3008K30/103170,3.70 Switch matrix,cetecom advanced GmbH,USM,A001,1.0.0 Test Parameter Technology to testBT LE 1 Msps EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 2402 Frequency mid to testTrue | Freq [MHz] 2440 Frequency high to testTrue | Freq [MHz] 2480 Auto control enabled power supply | Climatic Box No | No Additional path loss [dB]0.7 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/EUT1.GEN1/EUT1.GEN2/ cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9045-24-01-03_TR1-A201-R01 Release 1 - Page 3 of 45 Test Parameter Switch bits 00010001:00010001:00000000:00000001 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-9045-24-01-03_TR1-A201-R01 Release 1 - Page 4 of 45 Test at TX 2402 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMIT…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.00 mW |