2BQH7-DM9100DMR Analog/Digital Mobile Radio

Xiamen HONGKAIDE Information Technology Co., Ltd.
DMR Analog/Digital Mobile Radio - FCC ID 2BQH7-DM9100 - Xiamen HONGKAIDE Information Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 30, 2025
Application Purpose
Original Equipment
Equipment Note
DMR Analog/Digital Mobile Radio
Frequency Range
2402.00000000 - 2480.00000000
Company
Xiamen HONGKAIDE Information Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ACKNOWLEDGEMENTThank you for purchasing HONGKAIDEproducts for amateur mobile radio. We always provide radio products that truly delight enthusi-asts. This is a rugged, high-quality, long-range, high-performance multi-band vehicle-mounted transceiver. It supports UHF/VHF wide-band analog + digital dual-mode systems. It can be compatible with existing conventional analog sys-tems, direct mode dual-slot communication, and supports various calling methods, voice encryp-tion, manual frequency input, one-touch calling, one-touch emergency alert, and short messaging features.WARNINGBefore using the device, ensure the antenna is installed properly before turning it on (operating radio equipment without an antenna can cause damage). PRECAUTIONS Please observe the following precautions to prevent fire, personal injury, and/or damage to the transceiv-er:Do not use this device while driving, as it is danger-ous.This transceiver is designed to operate on a 12-13.8V DC power supply.Do not place the device in dusty, humid, or splashed water environments, or on unstable surfaces.If the device experiences external interference, move it away from interference sources (such as televisions, generators, etc.).Do not expose the device to direct sunlight for extended periods or place it near heating devices.If the device emits smoke or strange odors, immedi-ately cut off the power, ensure the device is safe, and send it to the nearest service station for inspec-tion. Avoid prolonged high-power transmission, which may cause the transceiver to overheat. Welcome to use our Amateur Mobile radio FUNCTION AND FEATURES Your new transceiver is beautiful, sturdy, durable, and offers excellent performance and outstanding value. It is a versatile vehicle-mounted transceiver meticulously designed for car enthusiasts. This product embodies innovation and practicality, with the following features: Ɣ&RPSUHKHQVLYH9RLFH&DOO)HDWXUHV6XSSRUWVYDULRXVFDOOPHW KRGV including individual call, group call, all call, and emergency call. Ɣ:LGHEDQG&RPPXQLFDWLRQ6XSSRUWV7;0+]0+] wide-band reception. Ɣ6KRUW0HVVDJLQJ6XSSRUWVVHQGLQJDQGUHFHLYLQJVKRUWPHVVDJ HVXSWR FKDUDFWHUVWH[WHGLWLQJDQGGUDIWER[IXQFWLRQDOLW\ Ɣ2QH.H\$ODUP3URJUDPPDEOHNH\OLQNHGWRHPHUJHQF\DODUPIX QFWLRQ for immediate assistance. Ɣ2QH.H\&DOO,QFOXGHVWH[WPHVVDJLQJYRLFHFDOODQGDSSOL FDWLRQ functions. Rich application features includes call reminder, radio detection, remote monitoring, remote kill, and activation. Ɣ0DQXDO)UHTXHQF\,QSXW6XSSRUWVPDQXDOIUHTXHQF\LQSXWZLWK RXW connecting to a computer. Ɣ6FDQQLQJ&DSDELOLWLHV6XSSRUWVVFDQQLQJRIDQDORJYRLFHDQG VLJQDOLQJ digital voice and data, priority channel scanning, and mixed analog-digital scanning. Scan list can be manually added or removed. Ɣ9RLFH(QFU\SWLRQ6XSSRUWV$5&DQG$(6HQFU\SWLRQƔ'LVWDQFH0HDVXUHPHQWƔ,QDGGLWLRQWRWKHLQKHUHQWHQFU\SWLRQSURYLGHGE\GLJLWDOW HFKQRORJ\ higher-level encryption capabilities are available. Ɣ6XSSRUWYRLFHLQWHUFRPDQGGDWDVHUYLFHVRI'LJLWDO5HSHDWHU 0RWRUROD and Hytera. Ɣ5HJLRQDO&KDQQHO*URXS6XSSRUWUHJLRQVZLWKXSWRFK DQQHOVSHU UHJLRQWRWDOLQJFKDQQHOVFRPPRQFRQWDFWVDQG &69 contacts. Ɣ%OXHWRRWK:LUHOHVV+DQG0LFURSKRQH)XQFWLRQ6XSSRUWV%OXHWR RWK headsets and Bluetooth PTT. Ɣ$OLDV7UDQVPLVVLRQDQG'LVSOD\Ɣ'LJLWDO$356)XQFWLRQDOLW\ Ɣ&RPSDWLEOHZLWK93RZHU6XSSO\ 7KHPDLQXQLWKDVD SRZHU voltage stabilization system, allowing users to connect freely and featuring a user-friendly circuit protection system.) Ɣ&RPSDFW6L]HIRU(DV\,QVWDOODWLRQƔ'XDO%DQG'XDO6WDQGE\5HFHSWLRQƔ6LQJOH%DQG/DUJH6FUHHQ'LVSOD\Ɣ3RZHU:Ɣ:LGH1DUURZ%DQG6HOHFWLRQ :LGHEDQG.DQG1DUURZEDQG .  Ɣ5HYHUVH)UHTXHQF\DQG2II1HWZRUN)XQFWLRQƔ[([WUD/DUJH6FUHHQZLWKIXOOGRWPDWUL[/&'GXDOURZ GLVSOD\RU dual-row character display. Ɣ&7&66'&6(QFRGLQJDQG'HFRGLQJZLWK&XVWRPL]DEOH6HWWLQJVƔ6FUHHQ%DFNOLJKW&RORU&XVWRPL]DWLRQƔ&DOOHU,''LVSOD\ $1,,GHQWLILFDWLRQ Ɣ3HUVRQDOL]HG+DQG0LFURSKRQHZLWK,QGLFDWRU/LJKWIRU(DV\8 VH Ɣ$XWRPDWLF7HPSHUDWXUHDQG3RZHU3URWHFWLRQƔ0XOWLSOH)DQ&RROLQJ$FWLYDWLRQ0HWKRGVƔ$QDORJ.'&DQG'70)Ɣ*36%HL'RX3RVLWLRQLQJ6XSSRUWVYLHZLQJ*36SRVLWLRQLQJLQI RUPDWLRQ and sending GPS text messages. Ɣ5HFRUGLQJ)XQFWLRQƔ5RDPLQJ)XQFWLRQƔ$QDORJ'LJLWDO'XDO0RGH&RPSDWLEOHZLWKH[LVWLQJFRQYHQW LRQDODQDORJ systems. Ɣ'027UXH6ORW'XDO6ORW&RPPXQLFDWLRQLQ'LUHFW0RGH(QKD QFHV communication efficiency and saves frequency resources. NoticeAcknowledgement Function and FeaturesSupplied and Optional Accessories 0RELOH,QVWDOODWLRQ/RFDWLRQ0LFURSKRQH&RQQHFWLRQDC Power Cable ConnectionFixed Station Installation Fuse ReplacementAntenna Connection$QWHQQD/RFDWLRQAntenna Connector ([WHUQDO0RQR6SHDNHUFront PaneProgrammable Key Shortcut FunctionsFunction Display Rear Panel 0LFURSKRQH0LFURSKRQH.H\ERDUG)XQFWLRQ'HVFULSWLRQ Power On and Off Power On  ----------------------------------------------------------------- ----------------------------------------------------------- -------------------------------------------              …

Text truncated - open the document above for the full version.

Attestation Statements

Xiamen HONGKAIDE Information Technology Co., Ltd. Add: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China Tel: +86 592 3201333 Email: [email protected] Attestation Letter Date: 2025-08-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements for Amateur TX Frequencies FCC ID: 2BQH7-DM9100 Xiamen HONGKAIDE Information Technology Co., Ltd. (“the applicant”) certifies that the equipment for transmitter frequencies can be programmed for only amateur frequencies (144-148 MHz, 420-450 MHz). Also, equipment programming is the responsibility of Authorized Service Personnel, in that the operator cannot directly program the transmit frequencies using the normally accessible external controls. Besides, the devices support BT &BLE 1M and scanning receive mode ( 136-174 MHz, 400-470 MHz), other functions has been shielded by software, and end user cannot activate them. Sincerely, Signature: Contact Person: Jack Williams Title: General manager

Attestation Statements

202 5-08-11 FEDERAL COMMUNICATIONS COMMISSIONS Autho rization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Declaration of compliance to the requirements of §15.121 We declare that, this scanning receiver is incapable of operating (tuning), or readily being altered by the users to operate, within the frequency bands allocated to the Cellular Radiotelephone Service in part 22 of this chapter (cellular telephone bands). This device will not be able to receive transmissions in the cellular telephone bands by means of clipping the leads of, or installing, a simple component such as a diode, resistor or jumper wire; replacing a plug-in semicon ductor chip; or programming a semiconductor chip using special access codes or an external device, such as a personal computer. This device is also incapable of converting digital cellular communication transmissions to analog voice audio. This device is designed so that the tuning, control and filtering circuitry is inaccessible. Any attempts to modify the equipment to receive transmissions from the Cellular Radiotelephone Service will render the receiver in operable. This scan ning receiver rejects any signals from the Cellular Radiotelephone Service frequency bands that are 38 dB or lower based upon a 12 dB SINAD measurement. Xiamen HONGKAIDE Information Technology Co., Ltd. ADD:NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China TEL:+86 592 3201333 E-mail:[email protected] FCC ID: 2BQH7-DM9100 We are aware that the modification of this device to receive transmissions from Cellular Radiotelephone Service frequency bands will be considered to constitute manufacture of such equipment. This includes any individual, individuals, entity or organization that modifies one or more scanners. Any modification to receive transmissions from the Cellular Radiotelephone Service frequency bands voids the certification of the scanning receiver, regardless of the date of manufacture of the original unit. Sincerely, Signature: Typed or Printed Name: Jack Williams Title:G eneral manager

Attestation Statements

Xiamen HONGKAIDE Information Technology Co., Ltd. Add: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China Tel: +86 592 3201333 Email: [email protected] CFR 47 §2.911(d)(5)(i)(ii) Attestation Letter Attestation Letter Date: 2025-08-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i)(ii) Filing FCC ID: 2BQH7-DM9100 Xiamen HONGKAIDE Information Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Xiamen HONGKAIDE Information Technology Co., Ltd. (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Xiamen HONGKAIDE Information Technology Co., Ltd. (“the applicant”) certifies that the equipment does not use Kaspersky's software information. Sincerely, Signature Contact Person: Jack Williams Title: General manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2025-08-11 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2BQH7-DM9100 Xiamen HONGKAIDE Information Technology Co., Ltd. (“the Applicant”) certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Xiamen HONGKAIDE Information Technology Co., Ltd. (“the Applicant”) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Xiamen HONGKAIDE Information Technology Co., Ltd. Address: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China FRN: 0037196318 Tel: +86 592 3201333 Email: [email protected] Signed by (printed name): Jack Williams Signature:

Cover Letter(s)

QA-FR-170-B Xiamen HONGKAIDE Information Technology Co., Ltd. Add: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China Tel: +86 592 3201333 Email: [email protected] FCC Authorization Date: 2025-08-11 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Xiamen HONGKAIDE Information Technology Co., Ltd., Hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: Jack Williams Title: General manager

Cover Letter(s)

QA-FR-171-A Xiamen HONGKAIDE Information Technology Co., Ltd. Add: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China Tel: +86 592 3201333 Email: [email protected] FCC Co nfidential Authorization D ate: 2025-08-11 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 S ubject: Confidentiality Request regarding application for certification of FCC ID: 2BQH7-DM9100 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, (Xiamen HONGKAIDE Information Technology Co., Ltd.) hereby requests long-term confidential treatment of information accompanying this application as outlined below: •B lock Diagram •Schematics •Operation Description • Inter nal ph oto T he above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. S incerely, S ignature: Pr inted name: Jack Williams Title: General manager

External Photos

China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 1 / 14 EUT EXTERNAL PHOTOGRAPHS China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 2 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 3 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 4 / 14 port port China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 5 / 14 port China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 6 / 14 port port China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 7 / 14 port China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 8 / 14 GPS Antenna Microphone China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 9 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 10 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 11 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 12 / 14 port China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 13 / 14 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2503Q10191E-RF-EXP Page 14 / 14 *****END *****

RF Exposure Info

RF EXPOSURE EVALUATION REPORT Applicant: Xiamen HONGKAIDE Information Technology Co., Ltd Address: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China FCC ID: 2BQH7-DM9100 Product Name: DMR Anolog/Digital Mobile Radio Standard(s): 47 CFR §1.1310 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: 2503Q10191E-RF-00E Date Of Issue: 2025/9/6 Reviewed By: Calvin Chen Title: RF Engineer Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-83085888 www.ccttt.com.cn China Certification ICT Co., Ltd (Dongguan) Report No.: 2503Q10191E-RF-00E Page 2 of 6 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. Each test item follows the test standard(s) without deviation. China Certification ICT Co., Ltd (Dongguan) Report No.: 2503Q10191E-RF-00E Page 3 of 6 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 4 1. RF EXPOSURE EVALUATION .............................................................................................. 5 1.1 Applicable Standard .......................................................................................................................................... 5 5.2 MEASUREMENT RESULT ..................................................................................................................... 6 China Certification ICT Co., Ltd (Dongguan) Report No.: 2503Q10191E-RF-00E Page 4 of 6 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 2503Q10191E-RF-00E Original Report 2025/9/6 China Certification ICT Co., Ltd (Dongguan) Report No.: 2503Q10191E-RF-00E Page 5 of 6 1. RF EXPOSURE EVALUATION 1.1 Applicable Standard According to 1.1310, 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. Limits for Maximum Permissible Exposure (MPE) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 Limits for Occupational/Controlled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3- 3.0 614 1.63 (100)* 6 3.0 - 30 1842/f 4.89/f (900/f 2 )* 6 30-300 61.4 0.163 1.0 6 300-1500 / / f/300 6 1500-100,000 / / 5 6 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); For simultaneously transmit system, the calculated power density should comply with: China Certification ICT Co., Ltd (Dongguan) Report No.: 2503Q10191E-RF-00E Page 6 of 6 5.2 Measurement Result General Population/Uncontrolled Exposure Mode Frequency (MHz) Antenna Gain Conducted output power including Tune-up Tolerance▲ Evaluation Distance Power Density MPE Limit (dBi) (numeric) (dBm) (mW) (cm) (mW/cm 2 ) (mW/cm 2 ) BDR/EDR 2402-2480 -8.05 0.16 7 5.01 20 0.0002 1 BLE 2402-2480 -8.05 0.16 7 5.01 20 0.0002 1 Occupational/Controlled Exposure Mode Frequency (MHz) Antenna Gain Conducted output power including Tune-up Tolerance▲ Evaluation Distance Power Density MPE Limit (dBi) (numeric) (dBm) (mW) (cm) (mW/cm 2 ) (mW/cm 2 ) VHF 144-148 0.15 1.04 45 31622.78 55 0.4326 1 UHF 420-450 5.50 3.55 44.5 28183.83 55 1.3160 1.4 Note: The Maximum Conducted Power including Tune-up Tolerance was declared by manufacturer. The VHF and UHF maximum operation duty cycle is 50%. The bluetooth and VHF or UHF can transmit simultaneously: =S Bluetooth /S limit-Bluetooth + S UHF /S limit-UHF =0.00002/1+1.316/1.4 =0.94 < 1.0 Result: The device meets FCC MPE at 55 cm distance ===== END OF REPORT =====

Test Report

TEST REPORT Applicant: Xiamen HONGKAIDE Information Technology Co., Ltd. Address: NO. 681, Xiahe Road, Siming District, Xiamen, Fujian Province, China FCC ID: 2BQH7-DM9100 Product Name: DMR Anolog/Digital Mobile Radio Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2020 KDB 558074 D01 15.247 Meas Guidance v05r02 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: 2503Q10191E-RF-00B Date Of Issue: 2025-09-06 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Lab Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-83085888 www.ccttt.com.cn China Certification ICT Co., Ltd (Dongguan) Report No.:2503Q10191E-RF-00B Page 2 of 70 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol ―▲‖. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk ―★‖. Each test item follows the test standard(s) without deviation. China Certification ICT Co., Ltd (Dongguan) Report No.:2503Q10191E-RF-00B Page 3 of 70 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.1.1 General ........................................................................................................................................................... 6 1.1.2 Operation Frequency Detail ........................................................................................................................... 6 1.1.3 Antenna Information Detail▲ ....................................................................................................................... 6 1.1.4 Accessory Information ................................................................................................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.1 EUT Operation Condition .............................................................................................................................. 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 8 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 2. SUMMARY OF TEST RESULTS .......................................................................................... 10 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 3.1.1 Applicable Standard ..................................................................................................................................... 11 3.1.2 EUT Setup.................................................................................................................................................... 12 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 12 3.1.4 Test Procedure ............................................................................................................................................. 13 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.2 RADIATED SPURIOUS EMISSIONS ...................................................................................................... 14 3.2.1 Applicable Standard ..................................................................................................................................... 14 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 15 3.2.4 Test Procedure .....................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.:2503Q10191E-RF-00B Page 1 of 21 Appendix A Test Information: Sample No.: 2YVR-1 Test Date: 2025/03/13~2025/09/6 Test Site: RF Test Mode: Transmitting Tester: Chin Qin Test Result: Pass Environmental Conditions: Temperature: (°C) 25.2-26.2 Relative Humidity: (%) 53-56 ATM Pressure: (kPa) 100.3-101.6 Test Equipment List and Details: Manufacturer Description Model Serial Number Calibration Date Calibration Due Date R&S Spectrum Analyzer FSU26 200256 2024/04/01 2025/03/31 R&S Spectrum Analyzer FSU26 200256 2025/03/31 2026/03/30 * Statement of Traceability: China Certification ICT Co., Ltd (Dongguan) attests that all calibrations have been performed, traceable to N ational Primary Standards and International System of Units (SI). Report No.:2503Q10191E-RF-00B Page 2 of 21 20 dB Emission Bandwidth Mode Channel Result (MHz) DH1 Low 0.981 Middle 0.990 High 0.987 2DH1 Low 1.206 Middle 1.206 High 1.203 3DH1 Low 1.182 Middle 1.179 High 1.185 Report No.:2503Q10191E-RF-00B Page 3 of 21 DH1_Low DH1_Middle DH1_High 2DH1_Low 2DH1_Middle 2DH1_High A Att 30 dB*Ref 30.5 dBm Offset 0.5 dB L VL Center2.402 GHzSpan3 MHz300 kHz/ 3 DB RBW 30 kHz SWT 15 ms * VBW 100 kHz* 1 PK MAXH S GL -60 -50 -40 -3 0 -20 -10 0 10 20 30 S W P 200 of 200 1 Mar ker 1 [T1 ] -16.17 dBm 2.401502000 GHz 1 Del ta 1 [T1 ] 0.18 dB 981.000000000 kHz D1 4.099 dBm D2 -15.901 dBm ProjectNo.:2503Q10191E-RF Tester:Chin Qin Date: 13.MAR.2025 17:49:37 A Att 30 dB*Ref 30.5 dBm Offset 0.5 dB LVL Center2.441 GHzSpan3 MHz300 kHz/ 3DB RBW 30 kHz SWT 15 ms * VBW 100 kHz* 1 PK MA X H SGL -60 - 50 -40 -3 0 - 20 -10 0 10 20 30 S W P 200 of 200 1 Ma r ker 1 [T1 ] -15.83 dBm 2.440502000 GHz 1 Delta 1 [T1 ] 0.21 dB 990.000000000 kHz D1 4.521 dBm D 2 -15.479 dBm ProjectNo.:2503Q10191E-RF Tester:Chin Qin Date: 13.MAR.2025 17:57:07 A Att 30 dB*Ref 30.5 dBm Offset 0.5 dB LVL Center2.48 GHzS pan 3 MHz 3 00 kHz/ 3DB RB W 3 0 kHz SWT 15 ms * VBW 100 kHz* 1 PK MAXH SGL -60 -50 -40 -30 -20 -10 0 10 20 30 SWP 200 of 200 1 Ma rker 1 [T1 ] -15.69 dBm 2.479505000 GHz 1 De lta 1 [T1 ] -0.32 dB 987.000000000 kHz D1 4.413 dBm D2 -15.587 dBm ProjectNo.:2503Q10191E-RF Tester:Chin Qin Date: 13.MAR.2025 18:31:25 A Att 30 dB*Ref 30.5 dBm Of fset 0 .5 dB L VL C enter 2 .402 GHz Spa n 3 MHz 3 00 kHz/ 3D B RBW 30 kHz SW T 15 ms * VBW 100 kHz* 1 P K MAXH S G L -6 0 -50 -40 - 30 -20 - 10 0 10 20 30 SWP 200 of 200 1 Marker 1 [T1 ] -20.43 dBm 2.401406000 GHz 1 Delta 1 [T1 ] 0.34 dB 1.206000000 MHz D1 0.07 dBm D2 -19.93 dBm ProjectNo.:2503Q10191E-RF Tester:Chin Qin Date: 13.MAR.2025 18:37:08 A Att 30 dB *Ref 30.5 dBm O ffset 0 .5 dB LVL C enter 2 .441 GHz Span3 MHz300 kHz/ 3DB RB W 3 0 kHz SWT 15 ms * VBW 100 kHz* 1 P K M AXH SGL -60 -5 0 -40 -3 0 -20 -10 0 10 20 30 SWP 200 of 200 1 Marker 1 [T1 ] -19.88 dBm 2.440409000 GHz 1 De lta 1 [T1 ] -0.02 dB 1.206000000 MHz D1 0.535 dBm D2 -19.465 dBm ProjectNo.:2503Q10191E-RF Tester:Chin Qin Date: 13.MAR.2025 18:43:58 A Att 30 dB *Ref 30 .5 dBm O ffset 0.5 dB LVL Center2 .48 GHz Sp an 3 MHz300 kHz/ 3DB RB W 30 kHz SW T 15 ms * VBW 100 kHz* 1 PK MAXH SGL -60…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jack Williams
[email protected]Fax: N/A

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided transmitter operating conditions for satisfying RF exposure compliance.