FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED/
  3. 2BR4N-PWR11310A

2BR4N-PWR11310A5000mAh Clear Power Bank

MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED
5000mAh Clear Power Bank - FCC ID 2BR4N-PWR11310A - MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Nov 26, 2025
Application Purpose
Original Equipment
Equipment Note
5000mAh Clear Power Bank
Frequency Range
0.11010000 - 0.20500000
Company
MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK) AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Sept.16,2025 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BR4N-PWR11310A MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED(“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§ 1.50002ofreferencechapter,asanentityproducing“covered”communicationequipment.The equipmentforwhichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideo surveillanceequipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibited fromreceivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:SallyWang Title:Manager Address:ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK Email:[email protected]

Attestation Statements

MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK) 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Sept.16,2025 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:2BR4N-PWR11310A ProductName:5000mAhClearPowerBank Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:SallyWang Title:Manager Address:ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK Tel.:18570650854 Email:[email protected] MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK) 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck SBOM(SoftwareBillofMaterials)[ForDeviceisnotInherentcompliance] SectionComponentNameVersionSupplier 1 2 3

Attestation Statements

MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK) U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:September16,2025 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:2BR4N-PWR11310A [MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED](“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,[GOLDENVICTORYINTERNATIONALTRADINGCOLTD](“theagent”) isourdesignatedU.S.agentforserviceofprocessfortheabovereferenceFCCID.Theapplicant acceptstomaintainanagentforserviceofprocessintheUnitedStatesfornolessthanoneyear aftereitherthegranteehaspermanentlyterminatedallmarketingandimportationoftheapplicable equipmentwithintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater.Theapplicantfurtheracknowledgesitisour responsibilitytoinformtheFCCwhenevertheagentinformationchanges. [GOLDENVICTORYINTERNATIONALTRADINGCOLTD]("theagent)understanditistheagent's obligationtoacceptserviceofprocessintheUnitedStatesformattersrelatedtotheapplicable equipment,andatthephysicalU.S.addressandemailaddress. DesignatedU.S.Agent CompanyName:GOLDENVICTORYINTERNATIONALTRADINGCOLTD FRN:0036377570 Address:11016THSTREETSUITE1400 DENVER,CO80202UnitedStates Signature: ContactPerson:LeonHowar ContactPerson:Manager Tel:(337)255-0461Email: [email protected] Applicant CompanyName:MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED FRN:0037488129 Address:ROOM1405B14/F,THEBELGIANBANKBUILDING, NOS.721-725NATHANROAD,MONGKOK,KOWLOON.HK Signature: ContactPerson:SallyWang (Title):Manager ContactPerson:Manager MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD,MONGKOK, KOWLOON.HK) Tel:18570650854Email:18570650854

Cover Letter(s)

MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED (ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD, MONGKOK,KOWLOON.HK) Date:November26,2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BR4N-PWR11310A PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired.  UserManual InternalPhotos Sincerely, (Signature) Title:Manager Address:ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHANROAD, MONGKOK,KOWLOON.HK Tel.:18570650854 Email:[email protected]

Cover Letter(s)

MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED (ROOM 1405B 14/F, THEBELGIAN BANKBUILDING, NOS.721-725NATHAN ROAD, MONGKOK, KOWLOON.HK) ( Date:Sept. 16, 2025) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: 2BR4N-PWR11310A I, the undersigned, hereby authorize (Guangdong Zhonghan Testing Technology Co., Ltd.) to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by (Guangdong Zhonghan Testing Technology Co., Ltd.) shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with (MEGIX TECHNOLOGY (ASIA)COMPANY LIMITED). We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, (Signature) (Full name of contactpersonlisted on FCC ’s website):Sally Wang (Title) :Manager Tel: 18570650854 Fax: 18570650854 Email: [email protected]

External Photos

FCCID:2BR4N-PWR11310A EUTPHOTO(ExternalPhotos) FCCID:2BR4N-PWR11310A FCCID:2BR4N-PWR11310A FCCID:2BR4N-PWR11310A ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

15mm FCC ID: FCC ID:2BR4N-PWR11310A 2BR4N-PWR11310A Radium carving white

RF Exposure Info

ProjectNo.:ZHT-250808114W02 Page 1 of 13 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby: Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:ThisdevicedescribedabovehasbeentestedbyZHT,andthetestresultsshowthattheequipment undertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport.Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZHT, thisdocumentmaybealteredorrevisedbyZHT,personalonly,andshallbenotedintherevisionofthe document. FCCTESTREPORT FCCID:2BR4N-PWR11310A ReportNo........................:ZHT-250808114W02 Product............................:5000mAhClearPowerBank Trademark.......................:BatteriesPlus, Model(s)...........................:PWR11310A ModelDifference..............:/ Applicant..........................:MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED Address...........................:ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHAN ROAD,MONGKOK,KOWLOON.HK Manufacturer....................:ShenzhenMegixTechnologyCo.,Ltd. Address............................:Room1517,BlockC,RongcheZhuihuiBuilding,IntersectionofLongsheng RoadandJinglongConstructionRoad,ShangfenCommunity,MinzhiStreet, LonghuaDistrict,ShenzhenCity,GuangdongProvince Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Aug.8,2025 DateofTest(s)................:Aug.8,2025toSept.11,2025 DateofIssue....................:Sept.11,2025 Standard .......................................... ::FCCCFRTitle47Part15SubpartC Testprocedure ................................ ::/ ProjectNo.:ZHT-250808114W02 Page 2 of 13 TABLEOFCONTENTS 1.GENERALINFORMATION......................................................................................................................3 1.1.GENERALDESCRIPTIONOFEUT.................................................................................................3 1.2.TESTMODES...................................................................................................................................4 1.3.AUXILIARYEQUIPMENT.................................................................................................................4 2.RFEXPOSURETEST..............................................................................................................................5 2.1.MEASURINGSTANDARD................................................................................................................5 2.2.REQUIREMENTS..............................................................................................................................5 2.3.LIMITS...............................................................................................................................................6 2.4.TESTSETUP....................................................................................................................................6 2.5.TESTPROCEDURE.........................................................................................................................7 2.6.MEASUREMENTUNCERTAINTY....................................................................................................7 2.7.TESTINSTRUMENTSLIST..............................................................................................................8 2.8.TESTRESULT..................................................................................................................................9 2.9.TESTPHOTOS...............................................................................................................................11 ProjectNo.:ZHT-250808114W02 Page 3 of 13 1.GENERALINFORMATION 1.1.GENERALDESCRIPTIONOFEUT ProductName:5000mAhClearPowerBank TestModelNo.: PWR11310A Hardwareversion:V1.0 Softwareversion:V1.0 OperationFrequency: Phone:110.1-205kHz Modulationtype:MSK AntennaType:CoilAntenna Antennagain:0dBi RatingsCapacity:5000mAh(19.25Wh/3.85V) Input:5V3A/9V2A/12V1.5A Output:5V3A/9V2A/12V1.5A WirelessOutput:5W/7.5W/10W/15W(Max) SampleNumber:250808114YP001 Remark:Theantennagainisprovidedbythecustomer,ifthedataprovidedbythecustomerisnotaccurate, GuangdongZhonghanTestingTechnologyCo.,Ltd.doesnotassumeanyresponsibility. ProjectNo.:ZHT-250808114W02 Page 4 of 13 1.2.TESTMODES TestModes: Mode1ACMains+Phonechargingport(BatteryStatus:≤1%) Mode2ACMains+Phonechargingport(BatteryStatus:50%) Mode3ACMains+Phonechargingport(BatteryStatus:≥98%) Mode4Phonechargingport(BatteryStatus:≤1%) Mode5Phonechargingport(BatteryStatus:50%) Mode6Phonechargingport(BatteryStatus:≥98%) Mode7Standby Note:1.Alltestmodeshasbeentested,thisreportonlyreflectedtheworstmode. 1.3.AUXILIARYEQUIPMENT Auxiliaryequipment ItemEquipmentMfr/BrandModel/TypeNo.SeriesNo.Note E-1ACAdapterXiaomiMDY-08-EH/AE E-2MobilephoneiQOOiQOO12Pro/AE ProjectNo.:ZHT-250808114W02 Page 5 of 13 2.RFEXPOSURETEST 2.1.MEASURINGSTANDARD KDB680106D01WirelessPowerTransferv04 2.2.REQUIREMENTS Accordingtotheitem5ofKDB680106D01v04: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcludedfrom submittinganRFexposureevaluation. Requirementsofsection3ofKDB680106D01Yes/NoDescription MobileDeviceandPortableDeviceConfigurationsYesMobileDevice EquipmentAuthorizationProceduresforDevicesOperatingat FrequenciesBelow4MHz Yes Thedeviceoperateinthe frequencyrange:110.1-205kHz RFExposurecompliancemaybeensuredonlyforaminimum conditionsatsmallerdistancescanstillbeconsidered unlikely.separationdistancethatisgreaterthan20cm,whileuse Yes TheEUTH-fieldandE-field strengthsat20cmsurrounding thedevice. ProjectNo.:ZHT-250808114W02 Page 6 of 13 2.3.LIMITS Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE)…

Text truncated - open the document above for the full version.

Test Report

disk wire glue adhesive tin backing Model: A11 Manufacturer: Shenzhen Megix Technology Co.,Ltd. Address: Room 1517, Block C, Rongche Zhuihui Building, Intersection of Longsheng Road and Jinglong Construction Road, Shangfen Community, Minzhi Street, Longhua District, Shenzhen City, Guangdong Province Note: 1. The coil is centered and flat; 2. Stick 42 * 7 white double-sided tape on the back: 3. 4. 5.

Test Report

ProjectNo.:ZHT-250808114W01 Page 1 of 23 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby: Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:ThisdevicedescribedabovehasbeentestedbyZHT,andthetestresultsshowthattheequipment undertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport.Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZHT, thisdocumentmaybealteredorrevisedbyZHT,personalonly,andshallbenotedintherevisionofthe document. FCCTESTREPORT FCCID:2BR4N-PWR11310A ReportNo........................:ZHT-250808114W01 Product............................:5000mAhClearPowerBank Trademark.......................:BatteriesPlus, Model(s)...........................:PWR11310A ModelDifference..............:/ Applicant..........................:MEGIXTECHNOLOGY(ASIA)COMPANYLIMITED Address...........................:ROOM1405B14/F,THEBELGIANBANKBUILDING,NOS.721-725NATHAN ROAD,MONGKOK,KOWLOON.HK Manufacturer....................:ShenzhenMegixTechnologyCo.,Ltd. Address............................:Room1517,BlockC,RongcheZhuihuiBuilding,IntersectionofLongsheng RoadandJinglongConstructionRoad,ShangfenCommunity,MinzhiStreet, LonghuaDistrict,ShenzhenCity,GuangdongProvince Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Aug.8,2025 DateofTest(s)................:Aug.8,2025toSept.11,2025 DateofIssue....................:Sept.11,2025 Standard..........................................::FCCCFRTitle47Part15SubpartC Testprocedure ................................ ::/ ProjectNo.:ZHT-250808114W01 Page 2 of 23 TABLEOFCONTENTS 1.VERSION..................................................................................................................................................3 2.TESTSUMMARY......................................................................................................................................4 3.GENERALINFORMATION......................................................................................................................5 3.1GENERALDESCRIPTIONOFEUT...................................................................................................5 3.2Testmode...........................................................................................................................................5 3.3BlockDiagramofEUTConfiguration..................................................................................................6 3.4TestConditions...................................................................................................................................6 3.5DescriptionOfSupportUnits(ConductedMode)...............................................................................6 4.TAESTFACILITYANDTESTINSTRUMENTUSED..............................................................................7 4.1TESTFACILITY..................................................................................................................................7 4.2EQUIPMENTSLISTFORALLTESTITEMS.....................................................................................7 4.3TESTINGSOFTWARE.......................................................................................................................8 5.CONDUCTEDEMISSIONTEST............................................................................................................10 5.1CONDUCTEDEMISSIONMEASUREMENT...................................................................................10 5.1.1POWERLINECONDUCTEDEMISSIONLimits...........................................................................10 5.1.2TESTPROCEDURE......................................................................................................................10 5.1.3DEVIATIONFROMTESTSTANDARD.........................................................................................10 5.1.4TESTSETUP.................................................................................................................................11 5.1.5EUTOPERATINGCONDITIONS..................................................................................................11 5.1.6TestResult.....................................................................................................................................12 6.RADIATEDEMISSIONMEASUREMENT..............................................................................................14 6.1RadiatedEmissionLimits..................................................................................................................14 6.2AnechoicChamberTestSetupDiagram..........................................................................................15 6.3TestProcedure.................................................................................................................................15 6.4DEVIATIONFROMTESTSTANDARD............................................................................................15 6.5TestResult........................................................................................................................................16 7.BANDWIDTHTEST................................................................................................................................19 8.ANTENNAREQUIREMENT...................................................................................................................22 9.TESTSETUPPHOTO............................................................................................................................23 10.EUTCONSTRUCTIONALDETAILS....................................................................................................23 ProjectNo.:ZHT-250808114W01 Page 3 of 23 1.VERSION ReportNo.IssueDateDescri…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BR4N-PWR11310A EUTTESTPHOTOS FCCID:2BR4N-PWR11310A FCCID:2BR4N-PWR11310A ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Sally Wang(Manager)
[email protected]Fax: 18570650854

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1101 MHz - 0.205 MHz-
Confidentiality
Long Term