FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen REMAX Tech. Co., L.T.D/
  3. 2BR9D-CX2

2BR9D-CX2REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh

Shenzhen REMAX Tech. Co., L.T.D
REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh - FCC ID 2BR9D-CX2 - Shenzhen REMAX Tech. Co., L.T.D
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 25, 2025
Application Purpose
Original Equipment
Equipment Note
REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh
Frequency Range
0.11000000 - 0.20500000
Company
Shenzhen REMAX Tech. Co., L.T.D
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen REMAX Tech. Co., L.T.D Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [September 18, 2025] U.S. Agent Designation [Shenzhen REMAX Tech. Co., L.T.D] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BR9D-CX2 Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [Shenzhen REMAX Tech. Co., L.T.D]. [Shenzhen REMAX Tech. Co., L.T.D] with the FRN [0037514007] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [ZHANG JIE] [Huiying Fan] [Legal person] [Director] [Shenzhen REMAX Tech. Co., L.T.D] [GLOCERTS TECHNOLOGY INC]

Attestation Statements

Shenzhen REMAX Tech. Co., L.T.D (September 17, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BR9D-CX2 [Shenzhen REMAX Tech. Co., L.T.D] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) ZHANG JIE Shenzhen REMAX Tech. Co., L.T.D (September 17, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BR9D-CX2 [Shenzhen REMAX Tech. Co., L.T.D] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) ZHANG JIE

Cover Letter(s)

Shenzhen REMAX Tech. Co., L.T.D (September 17, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh / CX-2 / FCC ID: 2BR9D- CX2) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: ZHANG JIE Title: Legal person

Cover Letter(s)

Shenzhen REMAX Tech. Co., L.T.D (September 17, 2025) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: ZHANG JIE Title: Legal person

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: CX-2 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

睿量 折叠支架磁吸15W无线充电源 10000mAh CX-02 镭雕 文件 9.50 87.779.16 80.57 59.43 FCC ID:2BR9D-CX2

RF Exposure Info

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 11 RF EXPOSURE REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh FCC ID: 2BR9D-CX2 Trademark: N/A Model Number: CX-2 Prepared For: Shenzhen REMAX Tech. Co., L.T.D Address: 3/F, B1 Building, Mingjun Industrial Park, Huarong Rd., longhua Area, Shenzhen Manufacturer: Shenzhen REMAX Tech. Co., L.T.D Address: 3/F, B1 Building, Mingjun Industrial Park, Huarong Rd., longhua Area, Shenzhen Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Aug. 19, 2025 Sample tested Date: Aug. 19, 2025 to Sep. 01, 2025 Issue Date: Sep. 01, 2025 Report No.: CTB25081900302RF02 Test Standards FCC CFR 47 part1, 1.1307(b), 1.1310, 47 CFR§2.1091; KDB 680106 D01 Wireless Power Transfer v04 Test Results PASS Remark: This is wireless charger EMF report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page2 of 11 Table of Contents Page 1 . GENERAL INFORMATION 3 1.1 . Independent Operation Mode 3 1.2 . Test Supporting System 3 2 .LIST OF TEST AND MEASUREMENT INSTRUMENTS 4 2.1 . For conducted emission at the mains terminals test 4 3. METHOD OF MEASUREMENT 5 3. 1.Applicable Standard 5 4. TEST RESULT 6 4.1. Conducted Emission at the Mains Terminals Test 6 4.2. Equipment Approval Considerations: 7 4.3. E and H field Strength 7 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page3 of 11 1. GENERAL INFORMATION 1.1. Independent Operation Mode The basic operation mode is: 1.1.1. wireless charger power: 2W/5W/7.5W/10W/15W 1.2. Test Supporting System Adapter Description: Adapter Model No.: HP18A-0902000-AU Power Input: AC100-240V~ 1.0A 50/60Hz Output: 9V2.0A DC Line: Unshielded, Detachable 1.2m Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page4 of 11 2.LIST OF TEST AND MEASUREMENT INSTRUMENTS 2.1. For conducted emission at the mains terminals test Item Equipment Brand Model No. Frequency Range Last calibration Calibrated until 1 EMF TESTER Wavecontrol SMP600/WP40 0-3 15SN0164/21W P1200029 2024.10.28 2025.10.27 Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page5 of 11 3. METHOD OF MEASUREMENT 3. 1.Applicable Standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. According to KDB 680106 D01 Wireless Power Transfer v04. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page6 of 11 4. TEST RESULT 4.1. Conducted Emission at the Mains Terminals Test Note: Measurements should be made from all sides and the top of the primary/client pair, with the 20 cm-0cm measured from the center of the top, and 15cm-0cm measured from the center of the rest Test Procedure: a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) 20 cm-0cm measured from the center of the top, and 15cm-0cm measured from the center of the rest sides. c) The turn table was rotated 360d degree to search of highest strength. d) The highest emission level was recorded and compared with limit as soon as measurement of each points were completed. e) The EUT were measured according to the dictates of KDB 680106 D01 Wireless Power Transfer v04. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF02 EMF Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page7 of 11 4.2. Equipment Approval Considerations: The EUT does comply with item 5(b) of KDB 680106 V04 1) Power transfer frequency is less than 1MHz Yes, the device operate in the frequency range from 110kHz to 205kHz 2) The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. Yes, the maximum output power of the primary coil is 15000mW. 3) A client device providing the maximum permitted load is placed in physical contact with the transmitter (i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact). Yes, the surfaces of the transmitter and client device enclosures are in physical contact 4) Only § 2.1091-Mobile exposure conditions apply (i.e., this provision does not cover § 2.1093-Portable exposure conditions).. No, the EUT is portable condition assessment. 5) The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. Yes, the EUT field strength levels are less 50% x MPE limit. 6) For systems with more than one radiating structure, the conditions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing maximum power available), and with all the ra…

Text truncated - open the document above for the full version.

Schematics

1 1 2 2 3 3 4 4 5 5 6 6 DD CC BB AA Title NumberRevisionSize A4 Date:2024/12/2Sheet of File:\\..\SQ-Q81-SW6236-CR5791GT.SchDocDrawn By: MOS MOS MOS Pi n1 0/ Pi n9 Pi n1 2/ Pi n1 1 Pi n1 4/ Pi n1 3 Pi n1 6/ Pi n1 5 4. 99K CSET( ) 2000mah 5. 6K 8. 66K 1 5K 27. 4K Cset =RCSET*4/ 5-2000mah RCSET 5000mah 1 0000mah 2500mah 20000mah NC/ 20K FLED/ BSET BVSET 4. 20V 4. 35V 4. 40V 4. 50V 3. 65V TMOD 1 1 0° C TMOD 20K KEY/ KMOD KMOD :,A1 1 3K 9. 1 K 5. 6K 3. 0K 1 3K 9. 1 K 5. 6K 3. 0K :A1A2 :A1 :,5s I 2CA2, NC 33K 1 5K 9. 1 K 5. 1 K 24K 0R 60° C; 70° C; 80° C; 90° C; 1 00° C; 50° C; NMOD NTC NTC:0°C45°C NTC:- 1 0°C60°C 62368 62368 33K 24K 1 5K 9. 1 K 5. 1 K 0R NC NTC:0°C55°C NTC:- 20°C60°C 62368: 0°C1 5°C:2/ 8* I CHG 1 5°C45°C: I CHG 45°C55°C:2、8* I CHG,VCHG0. 25V 62368: - 20°C0°C:1 / 4* I DI SCHG 0°C60°C: I DI SCHG NTC:0°C55°C NTC:- 20°C60°C 62368: 0°C1 5°C:2/ 8 * I CHG 1 5°C45°C: I CHG 45°C55°C:2/ 8* I CHG 62368 NTC:1 0°C45°C NTC:- 1 0°C60°C 62368: 1 0°C20°C:2/ 8 * I CHG 20°C45°C: I CHG 62368 NTC:0°C60°C NTC:- 20°C60°C 62368 62368 NTC:0°C45°C NTC:- 20°C60°C 62368 62368 NTC:0°C45°C NTC:- 20°C60°C 62368: 0°C1 5°C:1 / 8* I CHG 1 5°C45°C:I CHG 62368 R0 VDM 1 0% X7R! ,AGND PVIN PVIN C MOS D6 1 A S1 DPA2/SCL 1 DMA2/SDA 2 SW1 3 SW2 4 SW3 5 SW4 6 SW5 7 BST 8 VBUSC2/VBUSBL 9 VOUTC2 10 VBUSC1 11 VOUTC1 12 VBUSA2 13 VOUTA2 14 VBU SA1 15 VOUTA1 16 BAT 17 NTC 18 VCC 19 NMOD 20 TMOD 21 CSET 22 KEY/KMOD/A212C 23 FLED/BSET 24 LED5/ I2CADD 25 LED4/LI2C 26 LED3/IRQ/SPSEG 27 LED2/SDA/BLUTH 28 LED1/SCK/WLSS 29 VOUTSP 30 VOUTSN 31 VOUT1 32 VOUT2 33 VOUT3 34 VOUT4 35 VOUT5 36 GATEC2/GATEBL 37 GATEC1 38 GATEA1 39 GATEA2 40 CC12/CCL 41 CC22/DATA 42 CC11 43 CC21 44 IDA1/CCO 45 ID2/ IRQ 46 DPC1 47 DMC1 48 DPC2/DPB 49 DMC2/DMB 50 DPA1 51 DMA1 52 PGND 53 SW6236 U1 5mR1 %R2 2. 2uHL1 C1 2 22uF/ 6. 3V C1 3 22uF/ 6. 3V 1 04/ 50V C1 4 NC R9 1 0K NTC1 NC R1 0 1 5K R1 1 20K R1 3 20K R1 4 1 04/ 50VC20 NC C28 226/1 0V C27 331 / 50V C1 331 / 50V C2 331 / 50V C3 226/ 25V C1 6 226/ 25V C1 7 226/ 25V C1 8 226/ 25V C21 C22 1 0uF/ 1 6V C9 1 0uF / 1 6V C6 1 0uF / 1 6V S1 1 D1 2 S2 3 G2 4 D2 5 G1 6 8205Q3 S1 1 D1 2 S2 3 G2 4 D2 5 G1 6 8205Q4 S1 1 D1 2 S2 3 G2 4 D2 5 G1 6 8205Q2 C+ CC D- D+ C- 7. 2uH CL1 EMC C46 EMC C37 0R R1 2 12 1.5K R29 1 2 30K 1 % R30 12 2. 7K 1 % R31 0.1uF C48 12 1 0K R27 6. 8nF C47 1 0nF C50 12 4.7R R32 4. 7uF/10V C53 4. 7nF C52 12 3K R28 4. 7nF C51 1 P1 1 P2 1 P3 1 P4 2. 2KR20 2. 2KR21 1 0KR22 1 2 3 4 5 6 18 17 16 15 14 13 192021222324 121110 987 CR5791 GT U7 100nF C38 100nF C45 1 0mR 1 % R24 22uF C40 1 00nF C39 22uF C44 1 00nF C43 1 2 EMC R26 12 EMC R23 2.2uF C36 2.2uF C35 1 0uF/ 1 6V C 3 4 2. 2nF C49 1 2 3 45 6 7 8 U3 CR40N272A 0.1uF/50V C31 R16 1 0K 3.9K R18 3.9K R19 8550 Q7 68NF/ M3L/ 50V 1206 C41 Q8 1 2 1 00K R25 EMC C42 BAT54C D8 100NF/M3L/50V1206 C29 100NF/M3L/50V1206 C30 100NF/M3L/50V1206 C33 CSO 4 IDMO 5 VDMO 6 VDM 10 PWM1 7 PWM2 8 EN 15 AGND 16 VDD 17 VCC 19 CSP 20 CSN 21 PGND 2 SW1 13 SW2 12 BST1 14 BST2 11 PVIN2 3 PVIN1 1 QDTE 9 AV IN 18 CR5173A U6 C5 1 0uF/ 1 6V S1 1 D1 2 S2 3 G2 4 D2 5 G1 6 8205Q1 1 KR8 12 1K R6 2KR1 5 104 C25 C26 10uF/16V 2301 Q5 1 2 510K R5 2N7002 Q6 1 00R R3 1 00R R4 1 2 3 WL9100_5.0V U2 9100 LED3 LED3 VBUSA2 VBUSA2 VBUSA2 VBUSA2 DMA1 BLED BLED BST VDD VBU SA1 VBUSA1 SW2 SW2 VCC VCC RLED RLED LED5/ I 2C/ ADD VOUT GATEA2 GAT EA2 GATEA2 GATEA1 GATEA1 GATEA1 VCOIL VC O IL DPA1DPC2/ DPB DPC2/ DPB DMC2/ DMB DMC2/ DMB OUTC OUTC CL C L CL CC21 DPC1DMC1 LED2 LED2 SW BAT+ BAT+ GATEC1 GATEC1 GATEC1 GATEC2/ GATEBL GATEC2/ GATEBL GATEC2/ GATEBL LED1 LED1 SCL SCL SCL NTC VBUSC1 VBUSC1 SDA SDA SDA VBUSC2/ VBUSBL VBUSC2/ VBUSBL CC1 1CC1 2/ CCL CC1 2/ CCL IRQ IRQ IRQ VOUTAC VOUTAC VOU TAC VOUTAC VOUTAC CSETTMOD V C V C V C V C V C NMOD F L ED/ BS ET KEY/ KMOD/ A2I C2 PW M2 PW M2 PW M1 PW M1 EN EN PER_EN VDMO VDMO CNL CNL DA DA DA DET_Q1 DET_ Q1 B8 SW1 PVI N VTANK1 VTANK1 VTANK1 A8 GND GND GNDGND BAT+ GND GND GND GND GND GND VCC GNDGNDGND GATEA1 LED5/I2C/ADD VBUSC2/VBUSBL VOUTAC VBUSC1 VOUTAC VBUSA2 VOUTAC VBU SA1 VOUTAC BAT+ DMA1 DPA1 DMC2/DMB DPC2/DPB DMC1 DPC1 GATEA2 GATEC1 GATEC2/GATEBL GND VOUTACVBUSC2/VBUSBL GATEC2/GATEBL GATEC2/GATEBL VBUSC1VOUTAC GATEC1 GATEC1 GND GND VBUSA2VOUTAC GATEA2 GATEA2 IRQ SDA SCL CC12/CCL DPC2/DPB DMC2/DMB GND GND VBUSA2 GND GND AGND VCOIL AGND AGND VC CL DA AGND VC SCL SDA IRQ DA AGND VC PWM2 PWM1 SDA CNL EN VDMO DET_Q1 BLED LED2 IRQ SCL LED3 LED1 OUTC OUTC GND GND VBUSA2 VTANK1 GND AGND EN VDMO PWM2 PWM1 GND GND SW2 DET_Q1 VTANK1 CNL VBUSA2 BAT+ GND CL RLED GND VBUSA1VOUTAC GATEA1 GATEA1 BLED LED2 LED1 LED3 RLED GND PER_EN GND CL DA B8 A8 VCVCC VBUSC1 VC VBUSA2 BAT+ R1/2RC82.2nF/50V SW GND B+1 B-1 R171K GND BAT+ BAT- GND VDD 1 GND 2 GND 3 VM 4 VM 5 U4 XB4908MF VDD 1 GND 2 GND 3 VM 4 VM 5 U5 XB4908MF C32 100nF/16V R7 NC C11 100nF/16V C15 100nF/16V C19 100nF/16V L2 0.01R@300MHz/6A L+ VBUSA1 L- GND C4 100nF/16V C7 1 0 0nF/ 1 6V C1 0 1 00nF/ 1 6V VBUSC1 1 2 3 4 5 6 7 8 9 10 11 12 GND VBUS CC1 DMC DMC DPC DPC CC2 VBUS GND J1 TY PE-C/16pin/ GND GND CC11 CC21 VBUSC1 DMC1 DMC1 DPC1 DPC1 C23 1 0 0nF/ 1 6V GND B8 A8 VOUTP PER_ EN D2 1N5819 D7 1N5819 D3 WLED D4 WLED D5 WLED D6 WLED D10 BLED D11 RLED GND D9 1N4148

Test Report

ANT PHTOT L W H 39mm±0.2 39mm±0.2 0.2mm±0.1 All measurements were performed radiated and therefore additional antenna gain documentation is not required.

Test Report

Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 23 TEST REPORT Compiled by: Reviewed by: Approved by: ZhouKui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand, 10000mAh FCC ID: 2BR9D-CX2 Trademark: N/A Model Number: CX-2 Prepared For: Shenzhen REMAX Tech. Co., L.T.D Address: 3/F, B1 Building, Mingjun Industrial Park, Huarong Rd., longhua Area, Shenzhen Manufacturer: Shenzhen REMAX Tech. Co., L.T.D Address: 3/F, B1 Building, Mingjun Industrial Park, Huarong Rd., longhua Area, Shenzhen Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Aug. 19, 2025 Sample tested Date: Aug. 19, 2025 to Sep. 01, 2025 Issue Date: Sep. 01, 2025 Report No.: CTB25081900302RF01 Test Standards FCC Part 15 C Test Results PASS Remark: This is wireless charger radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB25081900302RF01 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 23 TABLE OF CONTENTS 1. GENERAL INFORMATION .......................................................................................................................... 3 1.1. Report information ................................................................................................................................... 3 1.2. Measurement Uncertainty ....................................................................................................................... 3 1.3. Test Facility ............................................................................................................................................. 3 1.4. Test Uncertainty ...................................................................................................................................... 4 2. PRODUCT DESCRIPTION ........................................................................................................................... 5 2.1. EUT Description ...................................................................................................................................... 5 2.2. Block Diagram of EUT Configuration ...................................................................................................... 5 2.3. Test Conditions........................................................................................................................................ 5 2.4. DescriptionOfSupport Units (Conducted Mode) ...................................................................................... 6 3. TEST RESULTS SUMMARY ........................................................................................................................ 7 4. TEST EQUIPMENT USED ............................................................................................................................ 8 4.1. MEASUREMENT INSTRUMENTS LIST ................................................................................................. 8 5. CONDUCTED EMISSION TEST................................................................................................................. 11 5.1. Block Diagram of Test Setup ................................................................................................................. 11 5.2. Test Standard ........................................................................................................................................ 11 5.3. Conducted Emission Limit ..................................................................................................................... 11 5.4. EUT Configuration on Test .................................................................................................................... 11 5.5. Operating Condition of EUT .................................................................................................................. 11 5.6. Test Procedure ...................................................................................................................................... 12 5.7. Test Result ............................................................................................................................................ 12 6. RADIATED EMISSION MEASUREMENT .................................................................................................. 15 6.1. Block Diagram of Test Setup ................................................................................................................. 15 6.2. Test Standard ........................................................................................................................................ 16 6.3. EMI Test Receiver Setup ...................................................................................................................... 16 6.4. Test Procedure ...................................................................................................................................... 16 6.5. Test Result ............................................................................................................................................ 16 7. OCCUPIED BANDWIDTH .............................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: CX-2 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: CX-2 Radiated Emission 9KHz-30MHz 30MHz-1GHz Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions

Contact Information

Applicant

ZHANG JIE
[email protected]Fax: 13538214502

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen REMAX Tech. Co., L.T.D

REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand 5000mAh - FCC ID 2BR9D-CX1 - Shenzhen REMAX Tech. Co., L.T.D
2BR9D-CX1

REWONDER Magnetic 7.5W Wireless Power Bank with Built-in Foldable Stand 5000mAh

Sep 22, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz