FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. QSoft Services Corp./
  3. 2BR9S-XFORGE01

2BR9S-XFORGE01Smart Phone

QSoft Services Corp.

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 12, 2025
Application Purpose
Original Equipment
Equipment Note
Smart Phone
Frequency Range
2402.00000000 - 2480.00000000
Company
QSoft Services Corp.
Country
Panama

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

QSoft Services Corp. U.S. Agen t L etter of Attestation To: F ed eral Communications Commission 7435 Oakland M ills Road , Colu mbia, MD 21046, USA Date: 11-27-2025 Ref: Attestation Statement – Part2.911(d)(7) filing FCC ID: 2BR9S -X FORG E01 QSoft Services Corp. (“the applicant”) certifies that, as of the date of the filing of the application, FCC US Agent, LLC(“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States forno less than one year after either the grantee has permanently terminated all marketing and im portation of the applicable equipment within the U.S., or the conclusion of any Com mission-related administrative or judicial proceeding involving the equipment, whichever is later . T he applicant further acknowledges it is our responsibility to inform the F CC whenever the agent information changes. FCC US Agent, LLC ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agen t Com pany Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Signature: Contact Person: Tim Payne Tel: 708-571-3148 Email: [email protected] Ap plicant Com pany Name: QSoft Services Corp. Address: Via E spana, Delta Bank B uilding 6th Floor , S uite 604D, Panam a City , P anam a Signature: Contact Person: Geralyn Ilagan Tel: +63 991 915 2672 Email: [email protected] FRN: 0037514262

Attestation Statements

(QSoft Services Corp.) (2025.12.02) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BR9S-XFORGE01) [QSoft Services Corp.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Geralyn Ilagan (QSoft Services Corp.) (2025.12-02) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BR9S-XFORGE01) [QSoft Services Corp.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Geralyn Ilagan

Cover Letter(s)

QSoft Services Corp. Agent Authorization Letter (2025-11-26) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park Sanwei, Xixiang, Bao'an District, Shenzhen, Guangdong, China Alex.li [email protected] to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Geralyn Ilagan / Manager Date/City: 2025-11-26/ Panama Phone: +63 991 915 2672 E-mail: [email protected]

Cover Letter(s)

QSoft Services Corp. Long Term Confidentiality Request Letter (2025-11-26) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product: Smart Phone Model No.: XForge 01 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the ● Schematic Diagram ● Block Diagram ● Part List / BOM List / PCB Layout ● Operational Description ● Tune-up Procedure ● Software Security Requirements for UNII devices Required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Please contact me if there is any information you may need. Sincerely, Geralyn Ilagan / Manager Date/City: 2025-11-26/ Panama Phone: +63 991 915 2672 E-mail: [email protected]

Cover Letter(s)

QSoft Services Corp. Short Term Confidentiality Request Letter (2025-11-26) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For Product: Smart Phone Model No.: XForge 01 To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, < QSoft Services Corp. >. requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which < QSoft Services Corp. > considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, < QSoft Services Corp. > feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Geralyn Ilagan / Manager Date/City: 2025-11-26/ Panama Phone: +63 991 915 2672 E-mail: [email protected]

ID Label/Location Info

Model:XForge 01 FCC ID:2BR9S-XFORGE01 Made in China SIZE:45X45MM IMEI1:356824550000001 IMEI2:356824550000002 SN:XForge0125073000001 Smart Phone

RF Exposure Info

Page 1 of 278 Report No.: N25091501214E FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093) and IEEE Std 1528-2013 Product Name: Smart Phone Brand Name: XForge Model Name: XForge 01 Family Model: N/A Report No.: N25091501214E FCC ID: 2BR9S-XFORGE01 Prepared for QSoft Services Corp. Via Espana, Delta Bank Building 6th Floor, Suite 604D, Panama City, Panama Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Page 2 of 278 Report No.: N25091501214E TEST RESULT CERTIFICATION Applicant’s name ................. : QSoft Services Corp. Address ................................. : Via Espana, Delta Bank Building 6th Floor, Suite 604D, Panama City, Panama Manufacturer's Name .......... : QSoft Services Corp. Address ................................. : Via Espana, Delta Bank Building 6th Floor, Suite 604D, Panama City, Panama Product description Product name ........................ : Smart Phone Brand Name ......................... : XForge Model and/or type reference .............................. : XForge 01 Family Model ......................... : N/A Standards ............................. : FCC 47 CFR Part 2(2.1093) IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093). The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number ............................ S2509160022-1# Date of Test Date (s) of performance of tests ............. : Sep. 13, 2025~ Sep. 28, 2025 Date of Issue .......................................... : Nov. 5, 2025 Test Result .............................................. : Pass Prepared By : Reviewed By : Approved By : Owen Xiao (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Page 3 of 278 Report No.: N25091501214E ※ ※ Revision History ※ ※ REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Nov. 5, 2025 Owen Xiao Page 4 of 278 Report No.: N25091501214E TABLE OF CONTENTS 1. General Information .......................................................................................... 6 1.1. RF exposure limits .................................................................................. 6 1.2. Statement of Compliance ....................................................................... 7 1.3. EUT Description ..................................................................................... 7 1.4. Test specification(s) ................................................................................ 9 1.5. Ambient Condition ................................................................................. 9 1.6. Facilities And Accreditations .................................................................. 9 1.6.1. Facilities ........................................................................................... 9 1.6.2. Laboratory Accreditations And Listings ............................................ 9 2. SAR Measurement System ............................................................................... 10 2.1. SATIMO SAR Measurement Set-up Diagram ......................................... 10 2.2. Robot ................................................................................................... 11 2.3. E-Field Probe ........................................................................................ 12 2.3.1. E-Field Probe Calibration ................................................................ 12 2.4. SAM phantoms .................................................................................... 13 2.4.1. Technical Data ................................................................................ 14 2.5. Device Holder ...................................................................................... 15 2.6. Test Equipment List .............................................................................. 16 3. SAR Measurement Procedures ........................................................................ 18 3.1. Power Reference.................................................................................. 18 3.2. Area scan & Zoom scan ........................................................................ 18 3.3. Description of interpolation/extrapolation scheme ............................. 20 3.4. Volumetric Scan ................................................................................... 20 3.5. Power Drift .......................................................................................... 20 4. System Verification Procedure ......................................................................... 21 4.1. Tissue Verification ................................................................................ 21 4.1.1. Tissue Dielectric Parameter Check Results ..................................... 22 4.2. System Verification Procedure ............................................................. 23 4.2.1. System Verification Results ............................................................ 24 5. SAR Measurement variability and uncertainty ................................................. 25 5.1. SAR measurement variability .......................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 69 of 278 Report No.: N25091501214E Back Side 20525/836.5 10M QPSK(1,24) 0.134 0.081 2.56 23.13 23.50 0.146 2025/9/27 26# 50%RB Front Side 20525/836.5 10M QPSK(25,0) 0.043 0.028 -1.90 22.50 22.12 0.039 2025/9/27 Back Side 20525/836.5 10M QPSK(25,0) 0.076 0.041 -2.23 22.50 22.12 0.070 2025/9/27 NOTE: Body-Worn SAR test results of LTE Band 5 Test Position of Hotspot with 10mm Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Front Side 20525/836.5 10M QPSK(1,24) 0.084 0.049 -3.96 23.13 23.50 0.091 2025/9/27 Back Side 20525/836.5 10M QPSK(1,24) 0.134 0.081 2.56 23.13 23.50 0.146 2025/9/27 26# Left Side 20525/836.5 10M QPSK(1,24) 0.077 0.045 -1.00 23.13 23.50 0.084 2025/9/27 Right Side 20525/836.5 10M QPSK(1,24) 0.129 0.076 2.38 23.13 23.50 0.140 2025/9/27 Bottom Side 20525/836.5 10M QPSK(1,24) 0.120 0.069 1.61 23.13 23.50 0.131 2025/9/27 50%RB Front Side 20525/836.5 10M QPSK(25,0) 0.043 0.028 -1.90 22.50 22.12 0.039 2025/9/27 Back Side 20525/836.5 10M QPSK(25,0) 0.076 0.041 -2.23 22.50 22.12 0.070 2025/9/27 Left Side 20525/836.5 10M QPSK(25,0) 0.039 0.026 2.56 22.50 22.12 0.036 2025/9/27 Right Side 20525/836.5 10M QPSK(25,0) 0.068 0.042 0.54 22.50 22.12 0.062 2025/9/27 Bottom Side 20525/836.5 10M QPSK(25,0) 0.062 0.035 4.78 22.50 22.12 0.057 2025/9/27 NOTE: 1.Hotspot SAR test results of LTE Band 5 2. Tested by : Max Zhou Page 70 of 278 Report No.: N25091501214E 1.1.9. SAR measurement Result of LTE Band 7 Test Position of Head Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Left Cheek 21100/2535 20M QPSK(1,49) 0.707 0.293 -1.17 23.67 24.00 0.763 2025/9/22 27# Left Tilt 15 Degree 21100/2535 20M QPSK(1,49) 0.407 0.169 3.89 23.67 24.00 0.439 2025/9/22 Right Cheek 21100/2535 20M QPSK(1,49) 0.670 0.264 -0.68 23.67 24.00 0.723 2025/9/22 Right Tilt 15 Degree 21100/2535 20M QPSK(1,49) 0.334 0.136 1.04 23.67 24.00 0.360 2025/9/22 50%RB Left Cheek 21100/2535 20M QPSK(50,24) 0.399 0.173 -1.63 22.67 23.00 0.430 2025/9/22 Left Tilt 15 Degree 21100/2535 20M QPSK(50,24) 0.237 0.095 0.72 22.67 23.00 0.256 2025/9/22 Right Cheek 21100/2535 20M QPSK(50,24) 0.356 0.146 0.93 22.67 23.00 0.384 2025/9/22 Right Tilt 15 Degree 21100/2535 20M QPSK(50,24) 0.169 0.070 -2.94 22.67 23.00 0.182 2025/9/22 NOTE: Head SAR test results of LTE Band 7 Test Position of Body-W orn with 10mm Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1g 10g 1RB Front Side 21100/2535 20M QPSK(1,49) 0.216 0.096 0.80 23.67 24.00 0.233 2025/9/22 Back 21100/2535 20M 0.594 0.275 -0.37 23.67 24.00 0.641 2025/9/22 28# Page 71 of 278 Report No.: N25091501214E Side QPSK(1,49) 50%RB Front Side 21100/2535 20M QPSK(50,24) 0.129 0.048 -2.90 22.67 23.00 0.139 2025/9/22 Back Side 21100/2535 20M QPSK(50,24) 0.344 0.163 -4.55 22.67 23.00 0.371 2025/9/22 NOTE: Body-Worn SAR test results of LTE Band 7 Test Position of Hotspot with 10mm Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Front Side 21100/2535 20M QPSK(1,49) 0.216 0.096 0.80 23.67 24.00 0.233 2025/9/22 Back Side 21100/2535 20M QPSK(1,49) 0.594 0.275 -0.37 23.67 24.00 0.641 2025/9/22 28# Left Side 21100/2535 20M QPSK(1,49) 0.366 0.166 -3.06 23.67 24.00 0.395 2025/9/22 Right Side 21100/2535 20M QPSK(1,49) 0.064 0.028 2.44 23.67 24.00 0.069 2025/9/22 Top Side 21100/2535 20M QPSK(1,49) 0.305 0.141 1.05 23.67 24.00 0.329 2025/9/22 50%RB Front Side 21100/2535 20M QPSK(50,24) 0.129 0.048 -2.90 22.67 23.00 0.139 2025/9/22 Back Side 21100/2535 20M QPSK(50,24) 0.344 0.163 -4.55 22.67 23.00 0.371 2025/9/22 Left Side 21100/2535 20M QPSK(50,24) 0.215 0.088 2.08 22.67 23.00 0.232 2025/9/22 Right Side 21100/2535 20M QPSK(50,24) 0.033 0.015 4.82 22.67 23.00 0.036 2025/9/22 Top Side 21100/2535 20M QPSK(50,24) 0.156 0.073 -4.61 22.67 23.00 0.168 2025/9/22 NOTE: 1.Hotspot SAR test results of LTE Band 7 2. Tested by : Max Zhou Page 72 of 278 Report No.: N25091501214E 1.1.10. SAR measurement Result of LTE Band 12 Test Position of Head Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Left Cheek 23095/707.5 10M QPSK(1,24) 0.083 0.066 3.00 22.82 23.00 0.087 2025/9/23 29# Left Tilt 15 Degree 23095/707.5 10M QPSK(1,24) 0.045 0.034 0.68 22.82 23.00 0.047 2025/9/23 Right Cheek 23095/707.5 10M QPSK(1,24) 0.075 0.058 -0.63 22.82 23.00 0.078 2025/9/23 Right Tilt 15 Degree 23095/707.5 10M QPSK(1,24) 0.038 0.029 -1.22 22.82 23.00 0.040 2025/9/23 50%RB Left Cheek 23095/707.5 10M QPSK(25,0) 0.047 0.033 -2.77 21.92 22.00 0.048 2025/9/23 Left Tilt 15 Degree 23095/707.5 10M QPSK(25,0) 0.024 0.020 -0.12 21.92 22.00 0.024 2025/9/23 Right Cheek 23095/707.5 10M QPSK(25,0) 0.040 0.034 -1.41 21.92 22.00 0.041 2025/9/23 Right Tilt 15 Degree 23095/707.5 10M QPSK(25,0) 0.020 0.017 -1.17 21.92 22.00 0.020 2025/9/23 NOTE: Head SAR test results of LTE Band 12 Page 73 of 278 Report No.: N25091501214E Test Position of Body-Worn with 10mm Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Front Side 23095/707.5 10M QPSK(1,24) 0.054 0.032 -1.38 22.82 23.00 0.056 2025/9/23 Back Side 23095/707.5 10M QPSK(1,24) 0.064 0.038 0.69 22.82 23.00 0.067 2025/9/23 30# 50%RB Front Side 23095/707.5 10M QPSK(25,0) 0.030 0.016 4.65 21.92 22.00 0.031 2025/9/23 Back Side 23095/707.5 10M QPSK(25,0) 0.038 0.022 -1.29 21.92 22.00 0.039 2025/9/23 NOTE: Body-Worn SAR test results of LTE Band 12 Test Position of Hotspot with 10mm Test channel /Freq. Test Mode SAR Value (W/kg) Power Drift (±5%) Conducted power (dBm) Tune-up power (dBm) Scaled SAR 1g (W/Kg) Date Plot 1-g 10-g 1RB Front S…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 140 of 278 Report No.: N25091501214E 12# SAR Measurement at U-NII-1 (Body, Validation Plane) Date of measurement: 15/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.37 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Validation plane Device Position Body Band U-NII-1 Signal IEEE 802.11 a Channels/Frequency Middle (40)/ frequency 5200.00 Mhz B. Permitivity Middle TX Frequency (MHz) 5200.00 Relative permitivity (real part) 37.12 Relative permitivity (imaginary part) 15.82 Conductivity (S/m) 4.57 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=1.00, Y=25.00 ; SAR Peak: 0.32 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.059 SAR 1g (W/Kg) 0.124 Variation (%) -3.56 Horizontal validation criteria: minimum distance (mm) 8.94 Vertical validation criteria: SAR ratio M2/M1 (%) 61.46 E. Z Axis Scan Z (mm) 0.00 2.00 4.00 6.00 8.00 10.0 0 12.0 0 14.0 0 16.0 0 18.0 0 20.0 0 22.0 0 SAR (W/Kg) 0.30 1 0.19 0 0.10 6 0.07 1 0.04 4 0.03 5 0.02 9 0.02 5 0.02 4 0.02 3 0.02 0 0.02 6 Page 141 of 278 Report No.: N25091501214E F. 3D Image 3D screen shot Hot spot position Page 142 of 278 Report No.: N25091501214E 13# SAR Measurement at U-NII-2a (Cheek, Left) Date of measurement: 17/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.37 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Left head Device Position Cheek Band U-NII-2a Signal IEEE 802.11 a Channels/Frequency Middle (56)/ frequency 5280.00 Mhz B. Permitivity Middle TX Frequency (MHz) 5280.00 Relative permitivity (real part) 35.11 Relative permitivity (imaginary part) 16.18 Conductivity (S/m) 4.74 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-7.00, Y=32.00 ; SAR Peak: 0.59 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.076 SAR 1g (W/Kg) 0.220 Variation (%) 3.89 Horizontal validation criteria: minimum distance (mm) 5.66 Vertical validation criteria: SAR ratio M2/M1 (%) 59.10 E. Z Axis Scan Z (mm) 0.00 2.00 4.00 6.00 8.00 10.0 0 12.0 0 14.0 0 16.0 0 18.0 0 20.0 0 22.0 0 SAR (W/Kg) 0.39 6 0.24 4 0.11 2 0.09 1 0.05 0 0.04 4 0.02 4 0.03 3 0.02 8 0.02 7 0.02 7 0.02 5 Page 143 of 278 Report No.: N25091501214E F. 3D Image 3D screen shot Hot spot position Page 144 of 278 Report No.: N25091501214E 14# SAR Measurement at U-NII-2a (Body, Validation Plane) Date of measurement: 17/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.37 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Validation plane Device Position Body Band U-NII-2a Signal IEEE 802.11 a Channels/Frequency Middle (56)/ frequency 5280.00 Mhz B. Permitivity Middle TX Frequency (MHz) 5280.00 Relative permitivity (real part) 35.11 Relative permitivity (imaginary part) 16.18 Conductivity (S/m) 4.74 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-1.00, Y=27.00 ; SAR Peak: 0.42 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.055 SAR 1g (W/Kg) 0.121 Variation (%) 1.75 Horizontal validation criteria: minimum distance (mm) 12.00 Vertical validation criteria: SAR ratio M2/M1 (%) 61.63 E. Z Axis Scan Z (mm) 0.00 2.00 4.00 6.00 8.00 10.0 0 12.0 0 14.0 0 16.0 0 18.0 0 20.0 0 22.0 0 SAR (W/Kg) 0.29 1 0.18 9 0.11 7 0.07 5 0.04 7 0.03 5 0.03 2 0.03 0 0.02 8 0.06 5 0.02 8 0.03 3 Page 145 of 278 Report No.: N25091501214E F. 3D Image 3D screen shot Hot spot position Page 146 of 278 Report No.: N25091501214E 15# SAR Measurement at U-NII-2c (Cheek, Left) Date of measurement: 18/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.36 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Left head Device Position Cheek Band U-NII-2c Signal IEEE 802.11 a Channels/Frequency Middle (120)/ frequency 5600.00 Mhz B. Permitivity Middle TX Frequency (MHz) 5600.00 Relative permitivity (real part) 35.19 Relative permitivity (imaginary part) 16.03 Conductivity (S/m) 4.99 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-6.00, Y=32.00 ; SAR Peak: 0.59 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.086 SAR 1g (W/Kg) 0.215 Variation (%) 4.44 Horizontal validation criteria: minimum distance (mm) 8.00 Vertical validation criteria: SAR ratio M2/M1 (%) 65.76 E. Z Axis Scan Z (mm) 0.00 2.00 4.00 6.00 8.00 10.0 0 12.0 0 14.0 0 16.0 0 18.0 0 20.0 0 22.0 0 SAR (W/Kg) 0.40 9 0.25 1 0.09 5 0.10 1 0.07 1 0.06 8 0.06 2 0.05 6 0.05 7 0.05 8 0.05 3 0.05 4 Page 147 of 278 Report No.: N25091501214E F. 3D Image 3D screen shot Hot spot position Page 148 of 278 Report No.: N25091501214E 16# SAR Measurement at U-NII-2c (Body, Validation Plane) Date of measurement: 18/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.36 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Validation plane Device Position Body Band U-NII-2c Signal IEEE 802.11 a Channels/Frequency Middle (120)/ frequency 5600.00 Mhz B. Permitivity Middle TX Frequency (MHz) 5600.00 Relative permitivity (real part) 35.19 Relative permitivity (imaginary part) 16.03 Conductivity (S/m) 4.99 C. SAR Surface and Volume SURFACE SAR VOLUME SAR Maximum location: X=-9.00, Y=22.00 ; SAR Peak: 0.26 W/kg D. SAR 1g & 10g SAR 10g (W/Kg) 0.072 SAR 1g (W/Kg) 0.113 Variation (%) 3.12 Horizontal validation criteria: minimum distance (mm) 0.00 Vertical validation criteria: SAR ratio M2/M1 (%) 0.00 E. Z Axis Scan Z (mm) 0.00 2.00 4.00 6.00 8.00 10.0 0 12.0 0 14.0 0 16.0 0 18.0 0 20.0 0 22.0 0 SAR (W/Kg) 0.21 1 0.15 4 0.10 2 0.08 6 0.07 0 0.06 9 0.05 4 0.05 1 0.05 0 0.05 1 0.05 5 0.05 0 Page 149 of 278 Report No.: N25091501214E F. 3D Image 3D screen shot Hot spot position Page 150 of 278 Report No.: N25091501214E 17# SAR Measurement at U-NII-3 (Cheek, Left) Date of measurement: 16/9/2025 A. Experimental conditions. Probe 0725-EPGO-448 ConvF 1.35 Area Scan dx=10mm dy=10mm, Complete Zoom Scan 7x7x12,dx=4mm dy=4mm dz=2.0mm,Complete Phantom Left head Device Position Cheek Band U-NII-3 Signal IEEE 802.11 …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 208 of 278 Report No.: N25091501214E Page 209 of 278 Report No.: N25091501214E Page 210 of 278 Report No.: N25091501214E Page 211 of 278 Report No.: N25091501214E Page 212 of 278 Report No.: N25091501214E Page 213 of 278 Report No.: N25091501214E Page 214 of 278 Report No.: N25091501214E Page 215 of 278 Report No.: N25091501214E Page 216 of 278 Report No.: N25091501214E Page 217 of 278 Report No.: N25091501214E Page 218 of 278 Report No.: N25091501214E Page 219 of 278 Report No.: N25091501214E Page 220 of 278 Report No.: N25091501214E Page 221 of 278 Report No.: N25091501214E Page 222 of 278 Report No.: N25091501214E Page 223 of 278 Report No.: N25091501214E Page 224 of 278 Report No.: N25091501214E Page 225 of 278 Report No.: N25091501214E Page 226 of 278 Report No.: N25091501214E Page 227 of 278 Report No.: N25091501214E Page 228 of 278 Report No.: N25091501214E Page 229 of 278 Report No.: N25091501214E Page 230 of 278 Report No.: N25091501214E Page 231 of 278 Report No.: N25091501214E

RF Exposure Info

Page 232 of 278 Report No.: N25091501214E Page 233 of 278 Report No.: N25091501214E Page 234 of 278 Report No.: N25091501214E Page 235 of 278 Report No.: N25091501214E Page 236 of 278 Report No.: N25091501214E Page 237 of 278 Report No.: N25091501214E Page 238 of 278 Report No.: N25091501214E Page 239 of 278 Report No.: N25091501214E Page 240 of 278 Report No.: N25091501214E Page 241 of 278 Report No.: N25091501214E Page 242 of 278 Report No.: N25091501214E Page 243 of 278 Report No.: N25091501214E Page 244 of 278 Report No.: N25091501214E Page 245 of 278 Report No.: N25091501214E Page 246 of 278 Report No.: N25091501214E Page 247 of 278 Report No.: N25091501214E Page 248 of 278 Report No.: N25091501214E Page 249 of 278 Report No.: N25091501214E Page 250 of 278 Report No.: N25091501214E Page 251 of 278 Report No.: N25091501214E Page 252 of 278 Report No.: N25091501214E Page 253 of 278 Report No.: N25091501214E Page 254 of 278 Report No.: N25091501214E

RF Exposure Info

Page 255 of 278 Report No.: N25091501214E Page 256 of 278 Report No.: N25091501214E Page 257 of 278 Report No.: N25091501214E Page 258 of 278 Report No.: N25091501214E Page 259 of 278 Report No.: N25091501214E Page 260 of 278 Report No.: N25091501214E Page 261 of 278 Report No.: N25091501214E Page 262 of 278 Report No.: N25091501214E Page 263 of 278 Report No.: N25091501214E Page 264 of 278 Report No.: N25091501214E Page 265 of 278 Report No.: N25091501214E Page 266 of 278 Report No.: N25091501214E Page 267 of 278 Report No.: N25091501214E Page 268 of 278 Report No.: N25091501214E Page 269 of 278 Report No.: N25091501214E Page 270 of 278 Report No.: N25091501214E Page 271 of 278 Report No.: N25091501214E <Justification of the extended calibration> If dipoles are verified in return loss (<-20dB, within 20% of prior calibration for below 3GHz, and <-8dB, within 20% of prior calibration for 5GHz to 6GHz), and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. <Head 750MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -29.73 - 52.50 - Feb. 21, 2024 29.875 0.488 52.798 0.298 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 272 of 278 Report No.: N25091501214E <Head 835MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -42.84 - 50.50 - Feb. 21, 2024 -46.216 7.88 51.571 1.071 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 273 of 278 Report No.: N25091501214E <Head 1800MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -24.53 - 44.8 - Feb. 21, 2024 -25.579 4.276 44.876 0.076 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 274 of 278 Report No.: N25091501214E <Head 1900MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -23.28 - 46.2 - Feb. 21, 2024 -27.206 16.86 46.948 0.748 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 275 of 278 Report No.: N25091501214E <Head 2450MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -29.27 - 53.6 - Feb. 21, 2024 -25.738 12.07 55.969 2.369 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole Verification Data Page 276 of 278 Report No.: N25091501214E <Head 2600MHz> Return Loss (dB) Delta (%) Impedance Delta(ohm) Date of Measurement -25.57 - 54.5 - Feb. 21, 2024 -23.352 8.674 55.439 0.939 Feb. 13, 2025 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Dipole V…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Geralyn Ilagan(Manager)
[email protected]Fax: N/A

Test Firm

Shenzhen NTEK Testing Technology Co., Ltd.Alex Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.01 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.