Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen Bestway Electronics Co.,Ltd 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Bestway Electronics Co.,Ltd Address:2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Product Name:Wireless Charger FCC ID:2BRCR-BW-MWLC01 Model(s):BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X”stand for numbers 0-9, letters A-Z, symbols -or space) 2.911(d)(5)(i) Equipment Type We, [Shenzhen Bestway Electronics Co.,Ltd] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: huanzhang Date: Nov. 20, 2025 Title:General Manager Company name: Shenzhen Bestway Electronics Co.,Ltd Signature: NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Shenzhen Bestway Electronics Co.,Ltd 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Bestway Electronics Co.,Ltd Address:2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Product Name:Wireless Charger FCC ID:2BRCR-BW-MWLC01 Model(s):BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X”stand for numbers 0-9, letters A-Z, symbols -or space) 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Bestway Electronics Co.,Ltd] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: huan z hang Date: Nov. 20, 2025 Title:General Manager Company name: Shenzhen Bestway Electronics Co.,Ltd Signature: NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Shenzhen Bestway Electronics Co.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Nov. 20, 2025 Subject; Request for Confidentiality FCC ID:2BRCR-BW-MWLC01 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: huan zhang Title:General Manager
Shenzhen Bestway Electronics Co.,Ltd Model Difference Declaration To Who m It May Concern, We, Shenzhen Bestway Electronics Co.,Ltd (Wireless Charger); Trade Mark: N/A, Model Number: BW- MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X” stand for numbers 0-9, letters A-Z, symbols -or space); All model’s the function, software and electric circuit are the same, only with a product model named different. Test sample model: BW-MWLC01. Please contact me if you have any question. S ignature: Date: Nov. 20, 2025 Name: huan zhang Title: General Manager
Shenzhen Bestway Electronics Co.,Ltd Agent Authorization Company:S henzhen Bestway Electronics Co.,Ltd Address:2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Product Name:Wireless Charger Model Number(s):BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X”stand for numbers 0-9, letters A-Z, symbols -or space) Product Description:Wireless Charger We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: Nov. 20, 2025 Signature: Name: huan zhang Title: General Manager Company: Shenzhen Bestway Electronics Co.,Ltd
FCC ID LABEL: Ca. 30mm x 20mm Label Location FCC ID: 2BRCR-BW-MWLC01
Page 1 of 11 Report No.: HK2509195380-2E FCC Test Report Test Report On Behalf of Shenzhen Bestway Electronics Co.,Ltd For Wireless Charger Model No.: BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X” stand for numbers 0-9, letters A-Z, symbols -or space) FCC ID: 2BRCR-BW-MWLC01 Prepared For: Shenzhen Bestway Electronics Co.,Ltd 2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Sep. 19, 2025 ~ Sep. 28, 2025 Date of Report: Sep. 28, 2025 Report Number: HK2509195380-2E Page 2 of 11 Report No.: HK2509195380-2E Test Result Certification Applicant’s Name ................. : Shenzhen Bestway Electronics Co.,Ltd Address.................................. : 2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Manufacturer's Name .......... : Shenzhen Bestway Electronics Co.,Ltd Address.................................. : 2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Product Description Trade Mark ................................ : N/A Product Name ........................... : Wireless Charger Model and/or Type Reference: BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X” stand for numbers 0-9, letters A-Z, symbols -or space) Standards ............................. : FCC CFR 47 PART 18, KDB 680106 D01 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of Performance of Tests ............ : Sep. 19, 2025 ~ Sep. 28, 2025 Date of Issue ........................................... : Sep. 28, 2025 Test Result ............................................... : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 11 Report No.: HK2509195380-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Frequency Band: 112-205KHz Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Middle CH 148 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. Summary of Test Results 2.1 Test procedures according to the technical standards: FCC KDB 680106 D01 Wireless Power Transfer v04 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB 680106 D01v04 Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2 Measurement Uncertainty The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 All Emissions, Radiated(<30M) (9KHz-30MHz) ±3.90dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 4 of 11 Report No.: HK2509195380-2E 2.3 Test Instruments Description Brand Model No. S/N Calibrated Date Calibrated Until Electric and Magnetic Field Analyzer narda EHP-200AC 180ZX11028 Feb. 19, 2025 Feb. 18, 2026 NOTE: 1. The calibration interval of the above test instruments is 12 months. 2.4 Test Mode Test Item Test mode Description MPE Test Cases Mode 1AC/DC Adapter+ EUT + Mobile Phone (Battery Status: <1%) Mode 2AC/DC Adapter+ EUT + Mobile Phone (Battery Status: <50%) Mode 3AC/DC Adapter+ EUT + Mobile Phone (Battery Status: >95%) Note: 1. All modes and configurations above have been tested, Only the result of the worst case was recorded in the report. 2. For Radiated Emission, 3axis were chosen for testing for each applicable mode. 3. The Mobile Phone provided by Lab. 4. According to the manufacturer's design principle, the wireless charging power will reach its maximum when the client device's battery level is between 1% and 10%. Page 5 of 11 Report No.: HK2509195380-2E 3. Maximum Permissible Exposure Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz; *Plane-wave equivalent power density. Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 Wireless Power Transfer v04. Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 6 of 11 Report No.: HK2509195380-2E 4. Test Procedure a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 20cm). E and …
Text truncated - open the document above for the full version.
Page 1 of 22 Report No.: HK2509195380-1E FCC Test Report Test Report On Behalf of Shenzhen Bestway Electronics Co.,Ltd For Wireless Charger Model No.: BW-MWLC01, BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X” stand for numbers 0-9, letters A-Z, symbols -or space) FCC ID: 2BRCR-BW-MWLC01 Prepared For: Shenzhen Bestway Electronics Co.,Ltd 2/F, Building 7, Fuqiao Industrial Zone 1, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen City, Guangdong Province, 518103, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Sep. 19, 2025 ~ Sep. 28, 2025 Date of Report: Sep. 28, 2025 Report Number: HK2509195380-1E Applican Address Manufa c Address Produc t Trade M Product Model a n Standar This pub the Shen of the ma not assu material Date of T Date (s) Date of I Test Re s nt’s Name . .................. cturer's Na .................. t Descriptio ark .............. Name ......... nd/or Type rds ............. blication ma nzhen HUAK aterial. She ume liability due to its p Test ........... of Perform a ssue .......... sult .............. T T A ................ : ................ : ame .......... : ................ : on ................... : ................... Reference : ................ : y be reprod K Testing Te enzhen HUA for damage placement a .................. ance of Test .................. .................. Testing Eng Technical M Authorized S Test Re : Shenzhe : 2/F, Buil d Fuhai Str Province, : Shenzhe : 2/F, Buil d Fuhai Str Province, : N/A : Wireless : BW-MW L variables space) : FCC CF R duced in wh echnology C AK Testing T es resulting and context. ............... : ts ............ : ............... : ............... : gineer Manager Signatory Page 2 of 2 esult Cer n Bestway ding 7, Fuqia reet, Bao’an , 518103, C n Bestway ding 7, Fuqia reet, Bao’an , 518103, C Charger LC01, BW-M , “X” stand R 47 PART hole or in pa Co., Ltd. is a Technology from the r e . Sep. 19, 20 Sep. 28, 20 Pass 2 rtificatio Electronics ao Industria n District, Sh China Electronics ao Industria n District, Sh China MXXXXXX, for number s 18 art for non-c acknowledg Co., Ltd. ta eader's inter 025 ~ Sep. 2 025 Len Liao Sliver Wa Jason Zho Report No n Co.,Ltd al Zone 1, Q henzhen Ci Co.,Ltd al Zone 1, Q henzhen Ci BW-WXXX s 0-9, letter commercial ged as copy akes no res rpretation o 28, 2025 o an ou o.: HK25091 Qiaotou Com ity, Guangd Qiaotou Com ity, Guangd XXXX (“XXX rs A-Z, symb purposes a yright owner ponsibility f of the reprod 95380-1E mmunity, ong mmunity, ong XXXX” are bols -or as long as r and source for and will duced e Page 3 of 22 Report No.: HK2509195380-1E Table of Contents Page 1 . Summary 5 1.1 . Test Procedures and Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2. General Information 6 2.1. General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3. Operation of EUT during Testing 7 2.4. Description of Test Setup 8 2.5. Description of Support Units 9 2.6. Measurement Instruments List 10 3. AC Conducted Emission Test 11 3.1. Block Diagram of Test Setup 11 3.2. Conducted Power Line Emission Limit 11 3.3. Test Procedure 11 3.4. Test Result 12 4. Radiated Emissions 14 4.1. Block Diagram of Test Setup 14 4.2. Rules and Specifications 15 4.3. Test Procedure 15 4.4. Test Result 16 5. Antenna Requirement 19 6. Test Setup Photos of the EUT 20 7. Photos of the EUT 22 Page 4 of 22 Report No.: HK2509195380-1E ** Modified History ** Revision Description Issued Date Remark Revision 1.0 Initial Test Report Release Sep. 28, 2025 Jason Zhou Page 5 of 22 Report No.: HK2509195380-1E 1. Summary 1.1. Test Procedures and Results Description of Test Section Number Result AC Conducted Emissions Test 18.307 COMPLIANT Radiated Emission Test 18.305 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty = 2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 22 Report No.: HK2509195380-1E 2. General Information 2.1. General Description of EUT Equipment: Wireless Charger Model Name: BW-MWLC01 Series Model(s): BW-MXXXXXX, BW-WXXXXXX (“XXXXXX” are variables, “X” stand for numbers 0-9, letters A-Z, symbols -or space) Model Difference: All model's the function, software and electric circuit are the same, only with product model named different. Test sample model: BW-MWLC01. Trade Mark: N/A FCC ID: 2BRCR-BW-MWLC01 Antenna Type: Coil Antenna Operation Frequency: 112KHz~205KHz Test Frequency: 148KHz Number of Channels: 1 Modulation Type: ASK Power Source: Input: 5V-3A, 9V-2.2A Output: 15W(MAX) Power Rating: Input: 5V-3A, 9V-2.2A Output: 15W(MAX) Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User’s Manual. 2. The cable loss data is obtained from the supplier. 3. The test results in the report only apply to the tested sample. Page 7 of 22 Report No.: HK2509195380-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency Middle CH 148KHz 2.3. Operation of EUT during Testing Test Item Test mode Description Radiated & AC Conducted Test Cases Mode 1 AC/DC Adapter+ EUT +Mobile Phone (Battery Status: <1%) Mode 2 AC/DC Adapter+ EUT +Mobile Phone (Battery Status: <50%) Mode 3 AC/DC Adapter+ EUT +Mobi…
Text truncated - open the document above for the full version.
Test Model: BW-MWLC01 Radiated Emission AC Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.112 MHz - 0.205 MHz | - |