Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 02, 2026
Application Purpose
Original Equipment
Equipment Note
Temperature and Strength Monitoring Sensor with BLE
Frequency Range
2402.00000000 - 2480.00000000
Company
Maturix ApS
Country
Denmark

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Maturix ApS Date:12-09-2025 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) Filing Re. KDB 986446 D01 FCC ID: 2BRK9-20102 Dear Sir or Madam, [Maturix ApS] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, [Maturix ApS] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. If you have any questions, please contact us. Sincerely, Contact name: Tobias Ejersbo Company name: Maturix ApS Address: Thomas B. Thriges Gade 42, st., 5000 Odense C, Denmark E-mail: [email protected] Tel: +45 884 417 81

Attestation Statements

V01222025 Certification for Designating a U.S. Agent for Service of Process In compliance with section 2.911(d)(7), all applicants are required to appoint a U.S.-based contact to serve as their agent for service of process. This requirement applies to both domestic and foreign applicants. Entities located within the United States are permitted to designate themselves as their own agent for this purpose. Regardless of the applicant’s status, the designation of the U.S. agent must be included as an attachment to the equipment authorization application. The written certification must adhere to the following requirements: 1. It must bear the signatures of both the applicant and the designated U.S. agent for service of process, provided the agent is a separate entity from the applicant. 2. It must clearly state the applicant’s consent and confirm the agent’s obligation to accept service of process on the applicant’s behalf. 3. It must include a physical address and email address located in the United States for the designated agent. 4. It must acknowledge that the applicant will maintain the designated agent’s role for at least one year after ceasing all marketing and importation activities or upon the conclusion of any FCC-related proceedings involving the equipment. Key Details Regarding the U.S. Agent for Service of Process: ● The agent cannot be a Telecommunication Certification Body (TCB) or have affiliations with one (e.g., the agent cannot work for or be owned by a TCB or a related company). ● The agent must not be an FCC-recognized testing laboratory or have affiliations with one (e.g., the agent cannot work for or be owned by a test lab or a related company). ● The agent may be an individual or a company entity. ● The designated agent entity must have a physical U.S. address and phone number. ● It is recommended that the agent possess a Federal Registration Number (FRN), and including the FRN in the agent letter is considered best practice. ● The agent designation letter may be general for the grantee and is not required to be FCC ID-specific. If there is a change in the U.S. Agent for Service of Process for devices that are still being marketed or have ceased marketing for less than one year, the TCB must request the FCC to place the application in Audit Mode for every relevant TC Number. The updated agent letter will then need to supersede the previous version. Important Note: The role of the U.S. Agent for Service of Process should not be confused with the authorized agent responsible for signing the FCC Form 731, cover letters included in the application, or the agent who interacts directly with the TCB. Note for Attestation Letter: Print the attestation letter onto the manufacturer's corporate letterhead prior to submission. V01222025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 United States Date: 01/08/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2BRK9-20102 Maturix ApS certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. Maturix ApS accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name Americas Compliance consulting, LLC dba iCertifi FCC FRN 0033399411 Address 2445 NE Division Street, Suite 202 Bend, OR 97703 United States Contact Person Paul Preston Telephone +1-866-885-4575 Email [email protected] Sincerely, Maturix ApS Americas Compliance Consulting LLC dba iCertifi 0037337714 0033399411 Tobias Ejersb Paul Preston CEO President/CEO Signature Signature

Cover Letter(s)

Maturix ApS Date (12/09/2025) TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request FCC ID: 2BRK9-20102 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (Maturix ApS) hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Block Diagram Theory of Operation Bill of Materials (Maturix ApS) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (up to 180) days: Internal Photographs User Manual Test Setup Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Tobias Ejersbo Telephone Number: 004588441781 Email: [email protected]

Cover Letter(s)

Maturix ApS Date: 2026-01-13 TUV SUD BABT UNLIMITED TCB Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom We, Maturix ApS (Address: Thomas B. Thriges Gade 42, st., 5000 Odense C, Denmark) Hereby declare: Product name: Nova FCC ID: 2BRK9-20102 All models are electrically identical with same Schematics, PCB Layout and RF parameter. The only difference is that the number of sensor connectors is different. 20102 has one sensor and 20103 has two sensors. Yours sincerely, Contact name: Tobias Ejersb Company name: Maturix ApS Address: Thomas B. Thriges Gade 42, st., 5000 Odense C, Denmark E-mail: [email protected] Tel: +45 884 417 81

Cover Letter(s)

Maturix ApS Date: 01-13-2026 FCC ID: 2BRK9-20102 Model Number: 20102, 20103 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Maturix ApS hereby declare that our product (Nova) Model Number: 20102, 20103 have been disabled BLE (2Mbps, 500kbps and 125kps) function by software due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Contact name: Tobias Ejersb Company name: Maturix ApS Address: Thomas B. Thriges Gade 42, st., 5000 Odense C, Denmark E-mail: [email protected] Tel: +45 884 417 81

External Photos

External Photos of 20102 External Photos of 20103

RF Exposure Info

Report Number: 6895025139201 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 2 RF exposure test exclusion evaluation report Product: Nova Model no.: 20102, 20103 FCC ID: 2BRK9-20102 Earphones Rating: 3.0VDC, 0.05A supplied by 1pc “CR2450” non-rechargeable Lithium Cell battery RF Transmission Frequency: 2402MHz-2480MHz Modulation: GFSK Antenna Type: PCB Antenna Max Antenna Gain: 0.81dBi Max Description of the EUT: The Equipment Under Test (EUT) is a Nova which Support Low Energy Bluetooth(1Mbps). Reference Report 6895025113501 1. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 2. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Max Tune-up power = 0dBm Distance = 5 mm f = 2.402 GHz [1/5] * SQRT(2.402) =0.3 0.3≤ 3.0 Report Number: 6895025139201 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, 518052, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 2 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By: John Zhi/ EMC Project Manager Hayden Hu/EMC Project Engineer Date: 2025-09-01 Date: 2025-09-01

Test Report

Report Number: 6895025113501 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 40 FCC - TEST REPORT Report Number : 6895025113501 Date of Issue: 2025-09-01 Model : 20102, 20103 Product Type : Nova Applicant : Maturix ApS Address : Thomas B. Thriges Gade 42, st., 5000 Odense C, Denmark Manufacturer : Cre8tek (Shenzhen) Company Limited Address : F4, Building A2, Xin Jian Xing Industry City, Guangqiao Road, Guangming New District, Shenzhen, 518107, P.R China Factory : Cre8tek (Shenzhen) Company Limited Address : F4, Building A2, Xin Jian Xing Industry City, Guangqiao Road, Guangming New District, Shenzhen, 518107, P.R China Test Result : ◼ Positive  Negative Total pages including Appendices : 40 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. Report Number: 6895025113501 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 40 1 Table of Contents 1 Table of Contents ............................................................................................................................................................... 2 2 Details about the Test Laboratory .................................................................................................................................... 3 3 Description of the Equipment Under Test ....................................................................................................................... 4 4 Summary of Test Standards ............................................................................................................................................. 5 5 Summary of Test Results .................................................................................................................................................. 6 6 General Remarks ............................................................................................................................................................... 7 7 Test Setups ......................................................................................................................................................................... 8 8 Systems Test Configuration .............................................................................................................................................. 9 9 Technical Requirement .................................................................................................................................................... 10 9.1 Conducted Peak Output Power ................................................................................................................................. 10 9.2 Power Spectral Density .............................................................................................................................................. 13 9.3 6 dB Bandwidth ............................................................................................................................................................ 15 9.4 Spurious RF Conducted Emissions .......................................................................................................................... 17 9.5 Band Edge .................................................................................................................................................................... 22 9.6 Spurious Radiated Emissions for Transmitter ......................................................................................................... 24 10 Test Equipment List ......................................................................................................................................................... 38 11 System Measurement Uncertainty ................................................................................................................................. 40 Report Number: 6895025113501 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 40 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Telephone: +86 755 8828 6998 Fax: +86 755 8828 5299 FCC Registration No.: 514049 FCC Designation Number: CN5009 Report Number: 6895025113501 EMC_SZ_FR_80.00 FCC Release 2023-12-01 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Guankou Erlu, Nantou, Nanshan District, Shenzhen, Guangdong, China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 40 3 Description of the Equipment Under Test Product: Nova Model no.: 20102, 20103 Brand name: Maturix FCC ID: 2BRK9-20102 Options and accessories: N/A Rating: 3.0VDC, 0.05A supplied by 1pc “CR2450” non-rechargeable Lithium Cell battery RF Transmission Frequency: 2402MHz-2480MHz No. of Operated Channel: 40 Modulation: GFSK Data Rate: 1Mbps Antenna Type: PCB Antenna Gain 0.81dBi Max Descri…

Text truncated - open the document above for the full version.

Test Report

MATURIXNOVA ANTENNA MEASUREMENT REPORT NEXTFOUR 2025 1 •Measured antenna: Bluetooth •Antenna model: PCB IFA •Antennamanufacturer: DreamDevicesTechnologies Mustionkatu2 20750 Turku Finland Antenna radiation pattern SUMMARY OF RESULTS NEXTFOUR 2025 2 •Bluetooth antenna’s s11 was measured and the results were very good. The antenna is naturally tuned well for 2.45GHz and thus does not require any additional matching. •The antenna’s radiation pattern was measured, and the results show good radiation towards all directions. S11 MEASUREMENTS AND ANTENNA TUNING NEXTFOUR 2025 3 •S11 parameter was measured from Bluetooth antenna. •S11 measurement shows how much of the overall power sent to the antenna is reflected. This indicates how well the antenna is tuned. •Limit of good performance is lower than -6dB reflection on the used frequency band. 4 S11 without matching was measured. Results shown below. S11 MEASUREMENT RESULTS •The return loss of the antenna without matching is extremely good. The return loss is easily below the recommended - 6dB on the entire band of use. •The antenna is extremely well tuned on 2.4GHz band. •Antenna does not require matching circuit. NEXTFOUR 2025 ANTENNA RADIATION MEASUREMENT RESULTS NEXTFOUR 2025 5 The radiation performance of the Bluetooth antenna was measured to confirm the antenna design. The measured radiation performance is good in all positions. The result of the antenna radiation measurements are shown below. -35,0 -30,0 -25,0 -20,0 -15,0 -10,0 -5,0 0,0 360 355 350 345 340 335 330 325 320 315 310 305 300 295 290 285 280 275 270 265 260 255 250 245 240 235 230 225 220 215 210 205 200 195 190 185 180 175 170 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 Maturix Bluetooth antenna, Horizontal position, Horizontal polarization, 2450 MHz Maturix Bluetooth antenna, Horizontal position, Vertical polarization, 2450 MHz Main antenna requirement -35,0 -30,0 -25,0 -20,0 -15,0 -10,0 -5,0 0,0 360 355 350 345 340 335 330 325 320 315 310 305 300 295 290 285 280 275 270 265 260 255 250 245 240 235 230 225 220 215 210 205 200 195 190 185 180 175 170 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 Maturix Bluetooth antenna, Side position, Horizontal polarization, 2450 MHz Maturix Bluetooth antenna, Side position, Vertical polarization, 2450 MHz Main antenna requirement -35,0 -30,0 -25,0 -20,0 -15,0 -10,0 -5,0 0,0 360 355 350 345 340 335 330 325 320 315 310 305 300 295 290 285 280 275 270 265 260 255 250 245 240 235 230 225 220 215 210 205 200 195 190 185 180 175 170 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 Maturix Bluetooth antenna, Vertical position, Horizontal polarization, 2450 MHz Maturix Bluetooth antenna, Vertical position, Vertical polarization, 2450 MHz Main antenna requirement NEXTFOUR 2025 6 Frequency / MHzEfficiency / %Peak Gain / dBi 240031-0,28 241037-0,03 2420380,15 2430410,18 2440460,22 2450510,81 2460440,14 2470420,05 248038-0,16 ANTENNA EFFICIENCY AND GAIN

Contact Information

Applicant

Tobias Ejersbo
[email protected]Fax: 88441190

Technical Contact

Americas Compliance consulting, LLC dba iCertifiPaul Preston
[email protected]

2445 NE Division Street. Suite 202 Bend, OR 97703 · United States

Test Firm

TUV SUD Cert & Testing (China) Co., Ltd.Harry Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz760.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is peak conducted output power.