FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Donghaorong Technology Co., LTD/
  3. 2BRPU-GL-10

2BRPU-GL-10wireless glasses

Shenzhen Donghaorong Technology Co., LTD
wireless glasses - FCC ID 2BRPU-GL-10 - Shenzhen Donghaorong Technology Co., LTD
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 23, 2026
Application Purpose
Original Equipment
Equipment Note
wireless glasses
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Donghaorong Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 Shenzhen Donghaorong Technology Co., LTD TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Donghaorong Technology Co., LTD Grantee code: 2BRPU FCC ID: 2BRPU-GL-10 FRN: 0037404761 Contact Name: zhang xuandong Address: Room 1002, Unit 1, No. 9, Fu’an Ge, Xintang Village, Jutang Community, Fucheng Street, Longhua District, Shenzhen Telephone No: +8613027941006 Fax No: +8613027941006 Email: [email protected] i. [Shenzhen Donghaorong Technology Co., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Donghaorong Technology Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Donghaorong Technology Co., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2026/1/15 Applicant’s Name: zhang xuandong Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

Shenzhen Donghaorong Technology Co., LTD Code 00018768 Ed. 1 Device wireless glasses Company name Shenzhen Donghaorong Technology Co., LTD Grantee code 2BRPU FCC ID 2BRPU-GL-10 FRN 0037404761 Contact name zhang xuandong Address Room 1002, Unit 1, No. 9, Fu’an Ge, Xintang Village, Jutang Community, Fucheng Street, Longhua District, Shenzhen Telephone number +8613027941006 E-mail [email protected] Chipset/module information AB5656T3 Operating System (if applicable) N/A Storage Capacity (hard drive or other permanent memory storage, if applicable) N/A 2 Item 1. The device is able to install software/program installation? ☐ Yes, go to Item 2. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A 3 # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: Android™ 10 – 14 N/A 3 Screen Resolution: Minimum resolution of 320 x 480 N/A # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; N/A 4 ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? ☐ Yes, go to Item 3. ☒ No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software Item 3. Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 # Wireless Interface Purpose Justification 1 1 After the review of this items, the device: ☒ Cannot support installation of any cybersecurity or anti-virus software on the covered list. ☐ Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third- party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: zhang xuandong Date: 2026/1/15 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications.

Attestation Statements

TCB CALL página 1 File FCC ID: 2BRPU-GL-10 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://www.sos.state.co.us/biz/BusinessEntityDetail.do?quitButtonDestination=BusinessEntityResults&nameTyp=ENT&masterFileId=20241973778&entityId2=20241973778&fileId=20241973778&srchTyp=ENTITY TCB CALL página 2 Google: ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter"

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Shenzhen Donghaorong Technology Co., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: January 15, 2026 Subject: Request for Confidentiality FCC ID: 2BRPU-GL-10 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info No No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: January 15, 2026 Name zhang xuandong Position Manager Company Name Shenzhen Donghaorong Technology Co., LTD Address Room 1002, Unit 1, No. 9, Fu’an Ge, Xintang Village, Jutang Community, Fucheng Street, Longhua District, Shenzhen Tel +8613027941006 Fax +8613027941006 Email [email protected]

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen Donghaorong Technology Co., LTD Company: Shenzhen Donghaorong Technology Co., LTD Address: Room 1002, Unit 1, No. 9, Fu’an Ge, Xintang Village, Jutang Community, Fucheng Street, Longhua District, Shenzhen Product Name: wireless glasses Model Number: GL-10 FCC Identifier: 2BRPU-GL-10 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: zhang xuandong Date: 2026-01-15 Title: Manager Signature of applicant:

External Photos

Page 1 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix II external photos FCC ID: 2BRPU-GL-10 Page 2 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 4 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 5 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------

ID Label/Location Info

Label and Location Material: Silk-screen Font color: White Size: L: 2cm*W: 1cm Label and Location W FCC ID: 2BRPU-GL-10 Model No.: GL-10 L

Internal Photos

Page 1 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix III internal photos FCC ID: 2BRPU-GL-10 Page 2 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China BT ANT Page 4 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 5 of 5 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------

RF Exposure Info

Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China RF Exposure evaluation FCC ID: 2BRPU-GL-10 According to 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison According to 47 CFR § 2.1093, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. This device is classified as a portable device and is subject to SAR evaluation requirements unless it meets the exclusion thresholds. EDR: Worse case output power is as below: [2402MHz: 1.59dBm] Maximum output power is 1.59dBm (1.44 mW). (1.44 mW /5mm)·[√2.402(GHz)]= 0.45 <3.0 for 1-g SAR. Then SAR evaluation is not required.

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 85 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BRPU-GL-10 On Behalf of Shenzhen Donghaorong Technology Co., LTD wireless glasses Model No.: GL-10 Prepared for : Shenzhen Donghaorong Technology Co., LTD Address : Room 1002, Unit 1, No. 9, Fu’an Ge, Xintang Village, Jutang Community, Fucheng Street, Longhua District, Shenzhen Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2512248-C01-R01 Date of Receipt : December 31, 2025 Date of Test : December 31, 2025- January 9, 2026 Date of Report : January 9, 2026 Version Number : V0 Page 2 of 85 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. Summary Of Standards And Results ............................................................................................ 6 1.1. Description of Standards and Results ..................................................................................... 6 2. General Information ........................................................................................................................ 7 2.1. Description of Device (EUT) .................................................................................................... 7 2.2. Accessories of Device (EUT) .................................................................................................. 8 2.3. Tested Supporting System Details .......................................................................................... 8 2.4. Block Diagram of connection between EUT and simulators ................................................... 8 2.5. Test Mode Description ............................................................................................................. 8 2.6. Software test version and power setting information .............................................................. 9 2.7. Test Conditions ........................................................................................................................ 9 2.8. Test Facility .............................................................................................................................. 9 2.9. Measurement Uncertainty ..................................................................................................... 10 2.10. Test Equipment List ............................................................................................................... 11 3. Maximum Peak Output Power ..................................................................................................... 12 3.1. Limit ....................................................................................................................................... 12 3.2. Test Procedure ...................................................................................................................... 12 3.3. Test Setup .............................................................................................................................. 12 3.4. Test Result ............................................................................................................................. 12 4. Bandwidth ..................................................................................................................................... 13 4.1. Limit ....................................................................................................................................... 13 4.2. Test Procedure ...................................................................................................................... 13 4.3. Test Result ............................................................................................................................. 13 5. Carrier Frequency Separation ..................................................................................................... 25 5.1. Limit ....................................................................................................................................... 25 5.2. Test Procedure ...................................................................................................................... 25 5.3. Test Result ............................................................................................................................. 25 6. Number Of Hopping Channel ...................................................................................................... 27 6.1. Limit ....................................................................................................................................... 27 6.2. Test Procedure ...................................................................................................................... 27 6.3. Test Result ............................................................................................................................. 27 7. Dwell Time ..................................................................................................................................... 29 7.1. Test limit ................................................................................................................................. 29 7.2. Test Procedure ...................................................................................................................... 29 7.3. Test Result ............................................................................................…

Text truncated - open the document above for the full version.

Test Report

www.inpaq.com.tw Antenna Test Report 1 /Customer 蓝牙天线 Project Ver1.2Antenna Revision Zhu Haokui Prepared by Donghaorong manufacturer 2025/09/21Date: Shenzhen Surbaner Technology Co., Ltd. 2/F, Building B25, Hengfeng Industrial City, Hezhou Community, Xixiang Street, Baoan District, Shenzhen City. www.inpaq.com.tw 1. Product Overview & Dimension 2. Test system 3. Antenna Matching Network 4. Test Result 4.1 S11 Parameter-VSWR 4.2Gain & Efficiency 4.3 2D Pattern 5. Conclusion 2 Purpose This report is to measure the performance of antenna 蓝牙天线 .The antenna operating frequency at 2400-2500MHz All test data are showed as below. Content www.inpaq.com.tw 3 1.Product Overview & Dimension Antenna www.inpaq.com.tw equipmentTest ItemSequence Number Agilent 5071C & Agilent 5062A VSWRS parameter Agilent 8960 E5515C& Agilent 4438C&CMW500 &CMW270 ETS&SATIMO TRP&TISOTA Test ETS&SATIMO Agilent 5071C Gain & Efficiency Gain & Efficiency 4 2.Test System www.inpaq.com.tw 6 3. Test Result 250024502400Frequency -9.07-40.2-11.6S11 3.1 S11 Parameter-VSWR www.inpaq.com.tw 7 3. Test Result 3.2 Gain & Efficiency efficiencyGain dbifrequency 0.54771.62592400 0.55611.64922410 0.59122.04772420 0.59192.02592430 0.57412.0892440 0.57612.00952450 0.59831.93192460 0.56561.95422470 0.52271.97462480 0.50211.56732490 0.51281.55742500 www.inpaq.com.tw 8 3. Test Result 3.3 2D Pattern X-YZ-Y Z-X www.inpaq.com.tw 9

Test Setup Photos

Page 1 of 2 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2BRPU-GL-10 Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (>1G) Page 2 of 2 Report No.: psi2512248-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Conducted emission Test ------End------

Contact Information

Applicant

zhang xuandong
[email protected]Fax: +8613027941006

Technical Contact

BERDAM LLCLeonardo Lei
[email protected]

110 16TH ST STE 1400 DENVER CO CO 80202 US · DENVER, Colorado, 80202 · United States

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.44 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Shenzhen Donghaorong Technology Co., LTD

wireless glasses - FCC ID 2BRPU-GLASSES5 - Shenzhen Donghaorong Technology Co., LTD
2BRPU-GLASSES5

wireless glasses

Jan 23, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WIRELESS EARBUDS - FCC ID 2BRPU-R80 - Shenzhen Donghaorong Technology Co., LTD
2BRPU-R80

WIRELESS EARBUDS

Sep 29, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter