2BRZZ-6220001PUThe product is the Xzense Power Unit, which receives control commands wirelessly from an associated Xzense Display Unit, either directly or via the Xzense Repeater, and regulates the chimney fan for fireplaces, stoves, and solid fuel boilers accordingly

Exodraft A/S
The product is the Xzense Power Unit, which receives control commands wirelessly from an associated Xzense Display Unit, either directly or via the Xzense Repeater, and regulates the chimney fan for fireplaces, stoves, and solid fuel boilers accordingly - FCC ID 2BRZZ-6220001PU - Exodraft A/S
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 11, 2026
Application Purpose
Original Equipment
Equipment Note
The product is the Xzense Power Unit, which receives control commands wirelessly from an associated Xzense Display Unit, either directly or via the Xzense Repeater, and regulates the chimney fan for fireplaces, stoves, and solid fuel boilers accordingly
Frequency Range
903.00000000 - 903.00000000
Company
Exodraft A/S
Country
Denmark

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Your energy. Optimized. Control US | Read and save these instructions! TypeID no. PasswordSerial number Pairing card (pin code) Power Unit ID Control panel serial no.* If you want an overview of your units’ ID numbers and passwords, you may note them here.. *The serial number is located on the back of the control panel. Your energy. Optimized. Control | Xzense Content Product information 7 Scope of supply 7 Accessories and spare parts 7 Regulatory information - FCC and ISED 8 Function - with temperature sensor activated 10 Function - with temperature sensor deactivated (ventilation) 10 Warranty 11 Setup and mounting 12 Mounting of sensor and Power Unit 12 Wiring diagram 14 Mounting of control panel 14 General use of the control panel 15 Generally add/delete devices 17 Add/pair with Power Unit 19 Test of communication/signal 24 Signal test 25 Language selection 26 Lighting and operation 27 Refire and Afterrun 28 Turn off the chimney fan 28 Ventilation 29 Weather station 30 System control 30 eXotelligence 31 Pairing with smartphone via Bluetooth 33 Basic features of the app 39 Ventilation with the app 43 Weather station in the app 44 Setup and history in the app 45 Accessories - Repeater 53 Accessories - XTP sensor 55 Technical specifications 57 Troubleshooting 57 User and service menu 59 Disposal Electrical and electronic equipment (EEE) often contain materials, components and substances that may harm the environment or be hazardous to your health. Products (WEEE) marked with the ‘crossed-out wheeled bin’ symbol should be disposed of separately from other waste at the end of its life. Though legislation may differ from country to country we strongly advise that electrical and electronic waste is separated from other waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste. How to use this manual This manual has been prepared based on the specific product and contains relevant technical information and installation guides. Accessories and spare parts are not covered by this manual. Please refer to the individual manuals of these components. This installation manual does not contain any system design documentation. Failure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the product. Errors and omissions excepted. Distributor in USA & Canada ENERVEX Inc. 1685 Bluegrass Lake Parkway Alpharetta GA 30004 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 [email protected] www.enervex.com Disposal Electrical and electronic equipment (EEE) often contain materials, components and substances that may harm the environment or be hazardous to your health. Products (WEEE) marked with the ‘crossed-out wheeled bin’ symbol should be disposed of separately from other waste at the end of its life. Though legislation may differ from country to country we strongly advise that electrical and electronic waste is separated from other waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste. How to use this manual This manual has been prepared based on the specific product and contains relevant technical information and installation guides. Accessories and spare parts are not covered by this manual. Please refer to the individual manuals of these components. This installation manual does not contain any system design documentation. Failure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the product. Errors and omissions excepted. Symbols The following symbols may be used in the manual to draw attention to danger or risk of personal injury or damage to the product. General prohibition Failure to observe instructions marked with the prohibited symbol may result in extreme danger or serious personal injury. General warning Failure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the product. General attention Marks a dangerous situation that, in the worst-case scenario, can cause serious personal injury or significant damage to the product. Electricity hazard/High Voltage Marks a situation in which caution is advised due to the risk of high voltage electric shock which can cause serious personal injury or significant damage to the product. Connect an earth terminal to the ground Failure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the product. Permitted and approved Permitted and approved method of installation. Prohibited and not approved Prohibited and not approved method of installation. US | 5 Warning To minimise the risk of fire, electric shock, personal injury and/or damage to the product please observe the following: • Please always read the manual and only use the product in accordance with the manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers. • All installations must be carried out by properly qualifi ed personnel in accordance with national legislation and regulations. • This product must be earthed. Get assistance from a qualifi ed electrician when in doubt. • This product must always be disconnected during the installation. • Prior to servicing the product, disconnect the power and ensure that it cannot accidentally be reconnected. • Exodraft always recommends the use of a smoke alarm when a solid fuel open fire is installed. • If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please ensure that the design meets the national legislation and regulations. If this cannot be achieved, a smoke alarm must be installed in the same room as the heat appliance. Your energy. Optimized. 6 | US US | 7 3112010_Xzense_US Warning To minimise the risk of fire, electric shock, personal injury and/or damage to the product please observe the following: • Please always read the manual and only use …

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Exodraft A/S Industrivej 10 DK-5550 Langeskov Tlf: +45 7010 2234 Fax: +45 7010 2235 [email protected] www.exodraft.dk Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02-04-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BRZZ-6220001PU Exodraft A/S (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Exodraft A/S (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, Anders Hoexbro Larsen x Rev 1/26/2023 Exodraft A/S Industrivej 10 DK-5550 Langeskov Tlf: +45 7010 2234 Fax: +45 7010 2235 [email protected] www.exodraft.dk Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04-02-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BRZZ-6220001PU Exodraft A/S (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Anders Hoexbro Larsen

Attestation Statements

Rev 1/26/2023 Exodraft A/S Industrivej 10 DK-5550 Langeskov Tlf: +45 7010 2234 Fax: +45 7010 2235 [email protected] www.exodraft.dk Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 04-02-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2BRZZ-6220001PU Applicant FRN: 0037463056 Exodraft A/S (“the applicant”) certifies that, as of the date of the filing of the application, FCC US AGENT, LLC.is our designated U.S. agent for service of process for the above referenced FCC ID. Exodraft A/S accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. FCC US AGENT, LLC.accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: FCC US AGENT, LLC. U.S. Agent FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Tel.: 708-571-3147 Email: [email protected] Sincerely, Exodraft A/S FCC US AGENT, LLC. Anders Hoexbro Larsen Tim Payne [U.S. Agent signature]

Cover Letter(s)

Rev 11/20/07 Exodraft A/S Industrivej 10 DK-5550 Langeskov Tlf: +45 7010 2234 Fax: +45 7010 2235 [email protected] www.exodraft.dk Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2BRZZ-6220001PU Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematic Schematic_radio_PU.pdf Schematic Schematic_controller_PU.pdf Block Diagram Block Diagram_6220001 Xzense Power Unit.pdf Operational Description Operational Description PU.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for 45 days: Exhibit Type File Name Internal photos Internal Photos_6220001 Power Unit.pdf Sincerely, Anders Hoexbro Larsen

ID Label/Location Info

Product system label on Power Unit: Production label: ETL Label on Power Unit: Power Unit – front Power Unit – left side O I Power Unit – right side PMN HVIN Serial no-LOT-date FCC ID ISED

RF Exposure Info

DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 © 2017 INTERTEK EXODRAFT RF EXPOSURE REPORT SCOPE OF WORK RF EXPOSURE CALCULATIONS – POWER UNIT (6220001) REPORT NUMBER 106266463ATL-008 ISSUE DATE REVISION DATE 11 November 2025 04 February 2026 PAGES 8 Non-Specific Radio Report Shell Rev. January 2025 Page 2 of 8 Exodraft / Power Unit RF EXPOSURE REPORT Report Number: 106266463ATL-008 Project Number: G106266463 Report Issue Date: 6220001 Report Revision Date: 04 February 2026 PMN: Xzense Power Unit Model/HVIN: 6220001 FVIN: V4.12 FCC ID: 2BRZZ-6220001PU IC: 34524-6220001PU Standards: FCC Title 47 CFR Part 1.1310 RSS-102, Issue 6 Test Location Client Intertek 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 USA FCC Designation: US1046 CAB Designator: US0128 Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Report prepared by Report reviewed by Jeremy Pickens / Senior Staff Engineer Michael Carlson / Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106266463ATL -008 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 3 of 8 Exodraft / Power Unit Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Evaluation Summary ........................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 FCC Routine Evaluation Exemption Criteria ..................................................................................... 6 6 ISED Routine Evaluation Exemption Criteria .................................................................................... 7 7 Revision History ................................................................................................................................... 8 Intertek Report Number: 106266463ATL -008 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 4 of 8 Exodraft / Power Unit 1 Introduction and Conclusion RF Exposure calculations were performed on the product constructed as described in Section 4. Information provided by the client including maximum output power, antenna gain(s), and minimum separation distance(s) was used to determine if the product under evaluation was exempt from routine evaluation. Any change in these stated values may invalidate these results. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product under evaluation is exempt from routine evaluation for each of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) evaluated. Intertek does not make any claims of compliance for samples or variants which were not evaluated. 2 Evaluation Summary Section Test full name Result 5 Routine Evaluation Exemption Criteria (FCC Title 47 CFR Part 1.1310) Compliant 6 ISED Routine Evaluation Exemption Criteria (RSS-102 Issue 6) Compliant Intertek Report Number: 106266463ATL -008 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 5 of 8 Exodraft / Power Unit 3 Client Information This evaluation was performed at the request of: Client: Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Contact: Christian Ahler Email: [email protected] 4 Description of Equipment Under Test and Variant Models Manufacturer: Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Equipment Under Test Description Manufacturer Model Number Serial Number Xzense Power Unit Exodraft a/s 6220001 Compliance Sys 2 Receive Date: 21 July 2025 Received Condition: Good Type: Production Description of Equipment Under Test (provided by client) The EUT was a fan powering unit for use in Exodraft’s Xzense wireless control system. Radio/Receiver Characteristics Frequency Range / Number of Channels 903MHz, 1 Channel Data Rate / Modulation Type(s) GFSK Channel Separation: NA Maximum Conducted Output Power: 12.28 dBm (16.90mW) Equipment Type Mobile – 20cm Separation Distance Antenna Type and Gain Board Mounted Antenna (Abracon, P/N: PRO-OB-471): +2.4dBi Intertek Report Number: 106266463ATL -008 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 6 of 8 Exodraft / Power Unit 5 FCC Routine Evaluation Exemption Criteria § 1.1310: The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of §2.1093 of this chapter. 5.1 Calculations (dBm)(W)(dBi)Numeric 90312.280.0172.41.7380.20.00590.602 Channel (MHz) Antenna Gain Measured Conducted Power Separation Distance (m) Result (mW/cm 2 ) Limit (mW…

Text truncated - open the document above for the full version.

Test Report

ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Features • Supports 868, 915 or 868+2400 MHz • Profile of 4.93 mm • Mixed Linear Polarization • Surface Mount • Durable-Shelf life of upto 10 years • Three different evaluation boards available: o “SMD 868” for 860-870 MHz o “SMD 915” for 902-928 MHz o “SMD 868+2400” for 860-870 + 2400-2500 MHz Applications • Wi-Fi/BT/LPWA/LoRA/SigFox/ISM • IoT, M2M o Industrial o Infrastructure o Medical • Remote Technology / Monitoring • Network devices • Consumer Tracking • Smart Metering Product Image ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Electrical Specification Note: All measurements were conducted on its evaluation board in free space. Performance will vary depending on the ground plane, application, and environment. Mechanical Specification Environmental Specification Parameter Specification Unit “SMD 868” “SMD 915” “SMD 868+2400” Operating Frequency 860 - 870 902 - 928 860 - 870 2400 - 2500 MHz Center Frequency 865 915 865 2450 Return Loss ˂ -9.9 ˂ -6.6 < -8.3 < -4.3 dB dB Polarization Mixed Linear Peak Gain 1.7 2.4 1 3.8 dBi Efficiency > 63 > 50 > 49 > 43 % Impedance 50 Ω Parameter Specification Antenna Dimension 34.00 x 11.53 x 4.93 mm Evaluation board Dimension “SMD 868” 120 x 50 mm Evaluation board Dimension “SMD 915” 120 x 50 mm Evaluation board Dimension “SMD 868+2400” 95 x 38 mm Mounting Type Surface Mount Parameter Specification Operating Temperature -40°C to +125°C Storage Temperature Maximum Temperature 400°C RoHS Compliance Yes Compliant with EU directive 2011/65/EU and 2015/863 Shelf life 10 years MSL Level 1, unlimited Mechanical resistance Immunity to vibrations IEC/EN 60068-2-6, Fc test Immunity to shock IEC/EN 60068-2-27, Ea test ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Product Dimension Unit : mm Antenna pins and keep-out block Unit : mm ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory PCB layout and antenna pin numbering The antenna uses PIFA technology and should thus be mounted on a ground plane. If there are several layers in the PCB, there is an advantage to add vias for smooth interconnection of the ground areas to avoid splits in the ground plane. It is also important that there is a ground clearance around the NC pads and the RF feed pad, through all layers of the PCB. It is recommended to implement a matching network to optimize the antenna impedance in your application. The components can be positioned under the antenna. See recommendations in the figures below. Pin configuration PCB Layout (from evaluation board) Clearance through all layers Unit: mm ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Measurement Setup The antenna measurements for 868 MHz were done with the OnBoard “SMD 868” evaluation board (PRO-EB-472, 120 x 50 mm) - measured in free space. The antenna measurements for 915 MHz were done with the OnBoard “ SMD 915” evaluation board (PRO-EB-476, 120 x 50 mm) - measured in free space. The antenna measurements for 868+2400 MHz were done with the OnBoard “SMD 868+2400” evaluation board (PRO-EB-531, 95 x 38 mm) - measured in free space. ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Reflection Characteristics “SMD 868” – Return Loss Total Radiation Efficiency “SMD 868” Maximum Radiation Gain “SMD 868” ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Reflection Characteristics “SMD 915” – Return Loss Total Radiation Efficiency “SMD 915” Maximum Radiation Gain “SMD 915” ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For terms and conditions of sales, please visit: www.abracon.com OnBoard 868/915/868+2400 MHz - Antenna PRO-OB-471 34.00 x 11.53 x 4.93 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory Reflection Characteristics “SMD 868+2400” – Return Loss Total Radiation Efficiency “SMD 868+2400” Maximum Radiation Gain “SMD 868+2400” ABRACON IS ISO9001-2015 CERTIFIED Hidden Creek Ln Spicewood TX 78669 5101 Phone: 512-371-6159 | Fax: 512-351-8858 REVISED: For ter…

Text truncated - open the document above for the full version.

Test Report

DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. January 2025 © 2025 INTERTEK EXODRAFT TEST REPORT SCOPE OF WORK RADIO TESTING – POWER UNIT (6220001) REPORT NUMBER 106266463ATL-005 ISSUE DATE REVISED DATE 11 November 2025 04 February 2026 PAGES 23 RADIO TEST REPORT Report Number: 106266463ATL-005 Project Number: G106266463 Report Issue Date: 11 November 2025 Report Revision Date: 04 February 2026 PMN: Xzense Power Unit Model/HVIN: 6220001 FVIN: V4.12 FCC ID: 2BRZZ-6220001PU IC: 34524-6220001PU Standards: 47 CFR Part 15 Subpart C, 15.247 RSS-247, Issue 4 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 RSS-GEN, Issue 5 Test Location Client Intertek 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 USA FCC Designation: US1046 CAB Designator: US0128 Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Report prepared by: Report reviewed by: Jeremy Pickens / Senior Staff Engineer Michael Carlson / Staff Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Report Number: 106266463ATL-005 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 3 of 23 Exodraft / Power Unit Table of Contents 1 Introduction and Conclusion .............................................................................................................. 4 2 Test Summary ...................................................................................................................................... 4 3 Client Information ................................................................................................................................ 5 4 Description of Equipment Under Test and Variant Models ............................................................. 5 5 Bandwidth ............................................................................................................................................. 7 6 Peak Output Power .............................................................................................................................. 9 7 Peak Power Spectral Density ........................................................................................................... 11 8 Conducted Spurious Emissions / Band Edge ................................................................................ 13 9 Radiated Spurious Emissions / Restricted Frequency Bands ...................................................... 15 10 AC Conducted Emissions ............................................................................................................. 20 11 Measurement Uncertainty ............................................................................................................. 22 12 Revision History ............................................................................................................................. 23 Intertek Report Number: 106266463ATL-005 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 4 of 23 Exodraft / Power Unit 1 Introduction and Conclusion The tests indicated in Section 2 were performed on the product constructed as described in Section 4. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. Intertek does not make any claims of compliance for samples or variants which were not tested. 2 Test Summary Section Test Description Test Specification Result FCC ISED 5 Occupied and DTS Bandwidth 15.247(a)(2) RSS-247 S5.2(a) RSS-GEN S6.7 Compliant 6 Peak Output Power 15.247(b)(3) RSS-247 S5.4(d) Compliant 7 Power Spectral Density 15.247(e) RSS-247 S5.2(b) Compliant 8 Conducted Spurious Emissions / Band Edge 15.247(d) RSS-247 S5.5 Compliant 9 Emissions in Restricted Frequency Bands 15.247(d) 15.205(a), 15.209(a) RSS-GEN S8.9-8.10 Compliant 10 AC Mains Conducted Emissions 15.207 RSS-GEN S8.8 Compliant NA Antenna Requirement 15.203 RSS-GEN S6.8 Compliant 1 1) The antenna is internal and not removable. Intertek Report Number: 106266463ATL-005 Revised: 04 February 2026 Non-Specific Radio Report Shell Rev. January 2025 Page 5 of 23 Exodraft / Power Unit 3 Client Information This evaluation was performed at the request of: Client: Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Contact: Christian Ahler Email: [email protected] 4 Description of Equipment Under Test and Variant Models Manufacturer: Exodraft A/S Industrivej 10, 5550 Langeskov, Denmark Equipment Under Test Description Manufacturer Model Number Serial Number Xzense Power Unit Exodraft a/s 6220001 Compliance Sys 2 Receive Date: 21 July 2025 Received Condition: Good Type: Production Description of Equipment Under Test (provided by …

Text truncated - open the document above for the full version.

Test Setup Photos

ExodraftA/S Test Setup Photographs FCC ID: 2BRZZ-6220001PU IC: 34524-6220001PU Antenna Port Conducted Emissions Radiated Spurious Emissions < 30MHz Radiated Spurious Emissions < 30MHz Radiated Spurious Emissions 30MHz-1GHz Radiated Spurious Emissions 30MHz-1GHz Radiated Spurious Emissions 1GHz-10GHz Radiated Spurious Emissions 1GHz-10GHz AC Conducted Emissions AC Conducted Emissions

Contact Information

Applicant

Anders Larsen(R&D manager)
[email protected]Fax: +45 7010 2235

Technical Contact

FCC US AGENT, LLC.Tim Payne
[email protected]

3722 Illinois Avenue · Saint Charles, Illinois, 60174 · United States

Test Firm

Intertek Testing Services NA Inc.Jeff Hiday
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 903 MHz16.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Other Applications from Exodraft A/S

The product is the Xzense XTP, a wireless pressure sensor designed to measure chimney draft for fireplaces, stoves, and solid fuel boilers. The XTP makes it possible to achieve a constant draft in the chimney, thereby ensuring optimum combustion. - FCC ID 2BRZZ-7501143XTP - Exodraft A/S
2BRZZ-7501143XTP

The product is the Xzense XTP, a wireless pressure sensor designed to measure chimney draft for fireplaces, stoves, and solid fuel boilers. The XTP makes it possible to achieve a constant draft in the chimney, thereby ensuring optimum combustion.

Feb 11, 2026

Equipment Class

DTS - Digital Transmission System
This product is a wireless Xzense Display Unit designed to control an external chimney fan for fireplaces, stoves and solid fuel boilers. - FCC ID 2BRZZ-6220000DURE - Exodraft A/S
2BRZZ-6220000DURE

This product is a wireless Xzense Display Unit designed to control an external chimney fan for fireplaces, stoves and solid fuel boilers.

Feb 04, 2026

Equipment Class

DTS - Digital Transmission System