FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. The Magic Home Network Technology Co.,Ltd./
  3. 2BS25-T3

2BS25-T3Vehicle Wireless Charger

The Magic Home Network Technology Co.,Ltd.
Vehicle Wireless Charger - FCC ID 2BS25-T3 - The Magic Home Network Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 10, 2026
Application Purpose
Original Equipment
Equipment Note
Vehicle Wireless Charger
Frequency Range
0.11000000 - 0.20500000
Company
The Magic Home Network Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

、Silver 20cm between the radiator & your body. should be installed and operated with minimum distance set forth for an uncontrolled environment. This equipment This equipment complies with FCC radiation exposure limits help. -Consult the dealer or an experienced radio/TV technician for from that to which the receiver is connected. -Connect the equipment into an outlet on a circuit different . -Increase the separation between the equipment and receiver -Reorient or relocate the receiving antenna. measures: try to correct the interference by one or more of the following turning the equipment off and on, the user is encouraged to to radio or television reception, which can be determined by installation. If this equipment does cause harmful interference guarantee that interference will not occur in a particular interference to radio communications. However, there is no used in accordance with the instructions, may cause harmful can radiate radio frequency energy and, if not installed and residential installation. This equipment generates uses and reasonable protection against harmful interference in a of the FCC Rules. These limits are designed to provide with the limits for a Class B digital device, pursuant to part 15 Note: This equipment has been tested and found to comply authority to operate the equipment. party responsible for compliance could void the user's Any Changes or modifications not expressly approved by the including interference that may cause undesired operation. (2) this device must accept any interference received, (1) This device may not cause harmful interference, and Operation is subject to the following two conditions: This device complies with part 15 of the FCC Rules.

Attestation Statements

Rev1/26/2023 TheMagicHomeNetworkTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:6-18-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BS25-T3 TheMagicHomeNetworkTechnologyCo.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. TheMagicHomeNetworkTechnologyCo.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (Applicantprintedname)songxusheng Rev1/26/2023 TheMagicHomeNetworkTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:6-18-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BS25-T3 TheMagicHomeNetworkTechnologyCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication, theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiaries oraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (Applicantprintedname)songxusheng

Attestation Statements

TheMagicHomeNetworkTechnologyCo.,Ltd. Room1401and1402A,No.150,HuangbianNorthRoad,HelongStreet,BaiyunDistrict,Guangzhou U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Jun.18,26 Ref: AttestationStatement–Part 2.911(d)(7)filing FCCID:2BS25-T3 TheMagicHomeNetworkTechnologyCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthe filingoftheapplication,[LOBOSIOWAINC](“theagent”)isourdesignatedU.S.agentforserviceof processfortheabovereferenceFCCID.Theapplicantacceptstomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment, whicheverislater.TheapplicantfurtheracknowledgesitisourresponsibilitytoinformtheFCC whenevertheagentinformationchanges. [LOBOSIOWAINC]("theagent)understanditistheagent'sobligationtoacceptserviceofprocess intheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agent CompanyName:LOBOSIOWAINC FRN:0036413961 Address:4623BittercreekDrColoradoSpringsco 80922Us Signature: ContactPerson:HarleyLi Tel:(818)818-0538Email:[email protected] Applicant CompanyName:TheMagicHomeNetworkTechnologyCo.,Ltd. FRN:0037636685 Address:Room1401and1402A,No.150,Huangbian NorthRoad,HelongStreet,BaiyunDistrict, Guangzhou Signature: ContactPerson:songxusheng Tel:18253230606Email:[email protected]

Cover Letter(s)

TheMagicHomeNetworkTechnologyCo.,Ltd. Date:6-18-2026 ProductModelNumber:T3 FCCID:2BS25-T3 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:songxusheng ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:18253230606 Onbehalfof:TheMagicHomeNetworkTechnologyCo.,Ltd.

Cover Letter(s)

TheMagicHomeNetworkTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:July1,2026 Subject;RequestforConfidentiality FCCID:2BS25-T3 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:songxusheng Title:Manager

External Photos

Page1of4 ReportNo.:FCS202605116 Externalphotos Photo1 Photo2 Page2of4 ReportNo.:FCS202605116 Photo3 Photo4 Page3of4 ReportNo.:FCS202605116 Photo5 Photo6 Page4of4 ReportNo.:FCS202605116 Photo7

ID Label/Location Info

LabelandLabelLocation FCCID:2BS25-T3 Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesired operation. L*W:3cm*2cm labelandWhitefont

Internal Photos

Page1of7ReportNo.:FCS202605116 Internalphotos Photo1 Photo2 Page2of7ReportNo.:FCS202605116 Photo3 Photo4 ANT

RF Exposure Info

FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com MPETestReport ReportNo:FCS202605116H01 Issuedfor Applicant: TheMagicHomeNetworkTechnologyCo.,Ltd. Address: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou ProductName: VehicleWirelessCharger BrandName: AtunusHome ModelName: T3 SeriesModel: N/A FCCID: 2BS25-T3 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName ...................... :TheMagicHomeNetworkTechnologyCo.,Ltd. Address......................................: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou Manufacture'sName ................ :TheMagicHomeNetworkTechnologyCo.,Ltd. Address......................................: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou ProductDescription ProductName ........................... :VehicleWirelessCharger BrandName.............................:AtunusHome ModelName..............................:T3 SeriesModel..............................:N/A TestStandards..........................: FCCCFR47part1,1.1307(b),1.1310,47CFRS2.1091: KDB680106WirelessPowerTransferD01V04 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests . :May14,2026~May27,2026 DateofIssue ................................. :May27,2026 TestResult.....................................:Pass Testedby: (orangeOuYang) Reviewedby : (jayden) Approvedby: ( JackWang ) Page3of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com ProductNameVehicleWirelessCharger TradeNameAtunusHome ModelNameT3 SeriesModelN/A ModelDifferenceN/A ChannelListPleaserefertotheNote2. Operationfrequency110-205kHz ModulationTypeMSK AntennaTypePlanarspiralcoilAntennawith0.0dBi Adapter Input:5V/2A;9V/1.67A Outputpower:15W/10W/7.5W/5W RatedvoltageDC9Vbyadapter TestvoltageDC9Vbyadapter HardwareversionnumberV1.1 SoftwareversionnumberV1.0 ConnectingI/OPort(s)PleaserefertotheUser'sManual Page4of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) 4TestSetup RFExposureEvaluation 1MeasuringStandard KDB680106WirelessPowerTransferD01V04 2Requirements AllrequirementsrefertoSection3ofKDB680106D01V04: 1.Thedevicesmaybeconsideredtomeetthe§2.1091-Mobileconditions(“generallybeusedinsucha waythataseparationdistanceofatleast20centimetersisnormallymaintainedbetweentheRF source'sradiatingstructure(s)and[thenearestperson]”) 2.DevicesOperatingatFrequenciesBelow4MHz. 3.For§2.1091-Mobiledevices,theMPElimitsbetween100kHzto300kHzaretobeconsideredthe sameasthoseat300kHzinTable1of§1.1310,thatis,614V/mand1.63A/m,fortheelectricfieldand magneticfield,respectively. Page5of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(20cmfromthetop)whichisbetween theedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E,F)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01WirelessPower Transferv04. 6. MeasurementUncertainty (95%confidencelevels,k=2) ItemUncertainty UncertaintyforH-Field2.36dB UncertaintyforE-Field2.42dB UncertaintyforconductedRFPower0.62dB Uncertaintyfortemperature0.2°C Uncertaintyforhumidity1.1% UncertaintyforDCandlowfrequencyvoltages0.06% 7.Equipmentlist TestEquipmentManufacturerModelNo.SN. Last calibration Calibrated until ElectricandMagnetic fieldprobe-Analyzer NardaEHP-200AN03565Aug25,2025Aug24,2026 Page6of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 9Necessaryaccessories EquipmentMfr/BrandModel/TypeNo.SerialNo.Note 1iPhone14promax Intelligent wirelesscharging fullfunctiontest module N/A Thisisfortestingonly inreport. PlacementMode1Photo 8Testmode ModeDescriptionRemark Mode1 5W 5% Mode250% Mode395% Mode4 7.5W 5% Mode550% Mode695% Mode7 10W 5% Mode850% Mode995% Mode10 15W 5% Mode1150% Mode1295% Page7of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page8of7ReportNo.:FCS202605116H01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-la…

Text truncated - open the document above for the full version.

Test Report

FCCTestReport ReportNo:FCS202605116W01 Issuedfor Applicant: TheMagicHomeNetworkTechnologyCo.,Ltd. Address: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou ProductName: VehicleWirelessCharger BrandName: AtunusHome ModelName: T3 SeriesModel: N/A FCCID: 2BS25-T3 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page 2 of 23 ReportNo.:FCS202605116W01 TESTRESULTCERTIFICATION Applicant’sName ...................... :TheMagicHomeNetworkTechnologyCo.,Ltd. Address......................................: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou Manufacture'sName ................ :TheMagicHomeNetworkTechnologyCo.,Ltd. Address......................................: Room1401and1402A,No.150,HuangbianNorthRoad, HelongStreet,BaiyunDistrict,Guangzhou ProductDescription ProductName ........................... :VehicleWirelessCharger BrandName.............................:AtunusHome ModelName..............................:T3 SeriesModel .............................. :N/A TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC TestProcedure..........................:ANSIC63.10:2020+Cor.1-2023 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests . :May14,2026~May27,2026 DateofIssue ................................. :May27,2026 TestResult.....................................:Pass Testedby: (orangeOuYang) Reviewedby : (jayden) Approvedby: ( JackWang ) FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page 3 of 23 ReportNo.:FCS202605116W01 TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................5 1.1TESTFACTORY................................................................................................................6 1.2MEASUREMENTUNCERTAINTY.....................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................8 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS..................9 2.4EQUIPMENTSLIST.........................................................................................................10 3CONDUCTEDEMISSIONMEASUREMENT..........................................................................11 3.1LIMIT.................................................................................................................................11 3.2TESTPROCEDURE........................................................................................................11 3.3TESTSETUP...................................................................................................................12 3.4TESTRESULTS...............................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................15 4.1LIMIT................................................................................................................................15 4.2TESTPROCEDURE........................................................................................................16 4.3TESTSETUP...................................................................................................................17 4.4TESTRESULTS...............................................................................................................18 (30MHZ-1000MHZ)................................................................................................................19 5.20DBBANDWIDTHTEST.....................................................................................................21 5.1LIMIT................................................................................................................................21 5.2TESTPROCEDURE........................................................................................................21 5.3TESTSETUP...................................................................................................................21 5.4TESTRESULTS...............................................................................................................22 6.ANTENNAREQUIREMENT...................................................................................................23 6.1STANDARDREQUIREMENT..........................................................................................23 6.2EUTANTENNA................................................................................................................23 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page 4 of 23 ReportNo.:FCS202605116W01 RevisionHistory Rev.IssueDateEffectPageContents 00May27,2026N/AN/A FluxComplianceServiceLabora…

Text truncated - open the document above for the full version.

Test Report

1.AntennaDescription FINEP/N:G50*0.8-20.5-0.15*24-10TS-6.5UH-L20MM+BJ Marketname/Modelname Φ 20MMX0.8MM ManufactureItonTechnologyCorp AntennaMax.Gain0dBi FrequencyRange110-205kHz ConnectTypeIntegerantenna VSWR1.1 2.Pictureofantenna 産品型號: DESC G50*0.8-20.5-0.15*24-10TS-6. 5UH-L20MM+BJ 版本 Rev:A.0 客戶CUST: 德福瑞林 客户料号CUSTP/N: 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATICDIAGRAM: A 50±0.5mm B 40.5±0.5mm C 20.5±0.5mm D 20±2mm E 3±2mm F 5.3±0.2mm K 2.3±0.15mm J 0.8±0.05mm I 注: 1. 交叉出线 ; 2. 线圈贴50mm双槽磁片,磁 片尺寸50 ±0.5mm, ,厚度为 0.8±0.05mm. 3. 磁片背面贴背胶 三、绕线参数WindingSpecification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 WindingDirection 1SF 丝包线 0.15*24P 10TsCCW 四、电气特性 ELECTRICALCHARACTERISTICS: 温度 TEMPERATURE:25±10°C, 湿度 RELATIVEHUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1IND.S-F 3.7uH±10%单独线圈 100KHz/1.0VLCZMETER1062B 2IND.S-F 6.5uH±10%加磁片 100KHz/1.0VLCZMETER1062B 3DCRS-F ≤85mΩ 100KHz/1.0VLCZMETER1062B 擬制/日期PREPAREDBY/DATE審核/日期CHECKEDBY/DATE 何立成2026.03.04

Test Setup Photos

Page 1 of2ReportNo.:FCS202605116 RE(30-1000MHz) RE(1000-6000MHz) Page 2 of2ReportNo.:FCS202605116 CEwirelesscharging

Contact Information

Applicant

song xusheng
[email protected]Fax: 18253230606

Technical Contact

LOBOS IOWA INCHarley Li
[email protected]

4623 Bittercreek Dr Colorado Springs co 80922 Us · United States

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term