FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhuimeng Intelligent Technology (Dongguan) Co., Ltd./
  3. 2BS2W-VERO

2BS2W-VEROmassager

Zhuimeng Intelligent Technology (Dongguan) Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 09, 2025
Application Purpose
Original Equipment
Equipment Note
massager
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhuimeng Intelligent Technology (Dongguan) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

FCC ID LABEL: Ca. 50mm x 20mm Label Location FCC ID: 2BS2W-VERO

RF Exposure Info

FCC RF Exposure EUT Description: massager Model No.: Vero FCC ID: 2BS2W-VERO 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation Frequency (MHz) Output power (dBm) Tune Up Power (dBm) Max Tune Up power (mW) Min test separation distance mm Result Limit SAR Test Exclusion BLE 2480 1.88 1±1(2) 1.585 5 0.499 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2510145622-E, antenna gain = 0.8dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. The test exclusion threshold is 0.499 which is<= 3, SAR testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm

Test Report

  2.4G FPC Antenna      Model No: %))1;;%/ Description: * )3&$QWHQQD,3(;&RQQHFWRUZLWK5*&DEOH PP/HQJWK Features: 2400-2500MHz IPEX-1 connector Structure: 360º Omnidirectional Radiation Cable Type˖5* Cable Length˖PP Dimension PP [ PP RoHS & REACH Complaint   %$7:,5(/(66    $17(11$    '$7$6+((7 ZZZEDWZLUHOHVVFRP     $SULO$ CONTENTS       %$7:,5(/(66       ZZZEDWZLUHOHVVFRP        VSWR Return Loss Gain Efficiency Gain & Efficiency Description Specifications Product Picture Mechanical Drawing Test Equipment Performance Data    Radiation Patterns  2D Radiation Patterns 3D Radiation Patterns         Bat Wireless BF2.4FNX26X10B1L120 is a widely used wireless communication product that uses a flexible substrate that can be bent, folded, and installed on curved surfaces or in narrow spaces.Flexible substrates (such as polyimide) enable circuits to adapt to complex spatial layouts and are suitable for wearable devices, folding screen mobile phones, etc. The thickness is usually 0.1~0.3mm which reduces the weight of the device and improves portability. 2.4G FPC has high- frequency performance, flexibility and high Classic application scenarios: Consumer electronics: Bluetooth headsets, smart watches, drone remote controls Industrial: RFID tags, wireless sensors Automotive electronics: tire pressure monitoring, vehicle antennas integration as its core advantages, and is a key component for miniaturization and high performance of wireless devices. 'HVFULSWLRQ $SULO$ ZZZEDWZLUHOHVVFRP      Bat Wireless provides customized services to optimize your device, we have a mature R&D team that can respond quickly to meet your needs. If you have any requirements, please contact our sales and FAE.     Part Number Description   %)  &RPSDQ\  %DW :LUHOHVV    )UHTXHQF\0+] )    1DPH)3& $QWHQQD 1    7\SH,QWHUQDO ;    &RQVWDQW   ; ; $SSUR[LPDWH 'LPHQVLRQV % ;PP   ,3(;,3(;&RQQHFWRU /    /HQJWK  /HQJWK      :LUH /HQJWK PP %))1;;%/  %$7:,5(/(66 ,3(; Connector ,3(;,3(;,3(;,3(;60$  Customizable Cable Length  Customizable Cable Type 5*5*5* 5*5*5* Customizable  Selection table     3DUDPHWHUV     7\S8QLWHV   1RWHV   $QWHQQD 7\SH   )3& $QWHQQD )UHTXHQF\ 5DQJH0+]    ,QSXW ,PSHQGHQFH Ÿ    96:5     *DLQ  G%L       3RODUL]DWLRQ 7\SH9HUWLFDO 3RZHU &DSDFLW\:   /LJKWQLQJ 3URWHFWLRQ    '& 9ROWDJH9   5DGLDWRU    [ 'LPHQVLRQV  PP  &RQQHFWRU 7\SH   ,3(;˄Customizable˅   5*˄Customizable &DEOH 7\SH ˅ P ˄Customizable &DEOH /HQJWK ˅ P  0RXQW ZD\   Crimp Connection &RORU   )3 Black 0HWHULDO &    :HLJKW  J   :DWHUSURRI 5DWLQJ   52+6 &RPSODLQW   a Conform 2SHUDWLQJ 7HPSHUDWXUH  ȭ   a 6WRUDJH 7HPSHUDWXUH  ȭ  6SHFLILFDWLRQ $SULO$ ZZZEDWZLUHOHVVFRP      (OHFWULFDO &KDUDFWHULVWLFV   0HFKDQLFDO &KDUDFWHULVWLFV   (QYLURQPHQWDO &KDUDFWHULVWLFV     %$7:,5(/(66 *Note: The above data is for reference only. Since the antenna function is relatively sensitive, please inform us for evaluation if there are any changes to the structural components around the main body of the antenna.    3URGXFW3LFWXUH $SULO$ ZZZEDWZLUHOHVVFRP       %$7:,5(/(66 * Product images are for reference only  0HFKDQLFDO 'UDZLQJ $SULO$ ZZZEDWZLUHOHVVFRP       %$7:,5(/(66     7HVWLQJ &DSDELOLW\   'HVFULSWLRQ     $FWLYH PHDVXUHPHQW   &DSDELOLW\ 753澝7,6澝(,53澝(,6 HWF 0RGH ****澝:L)L EJQDDFD[澝%7澝1%,27澝&DW0 H07& 澝*36%(,'28*/21$66澝=LJ%HH澝/R5D 1RQ 6LJQDOLQJ HWF       3DVLYH PHDVXUHPHQW 7HVW FDWHJRU*DLQ澝(IILFLHQF\澝' SDWWHUQ澝' SDWWHUQ澝 3DWWHUQ URXQGQHVV澝$[LDO 5DWLR (&&3KDVH FHQWHU HWF 3RODUL]DWLRQ &LUFXODU SRODUL]DWLRQ OLQHDU SRODUL]DWLRQ HOOLSWLFDO SRODUL]DWLRQ   6SHFLILFDWLRQ '7 'DWDVKHHW 'HVFULSWLRQ  0+]*0+ 7HVW )UHTXHQF\ ]   / : +    6\VWHP 6L]H P   3UREH  OLQN1XPEHU RI 3UREHV   ,QWHUYDO $QJOH ž  P 6DPSOLQJ 'LDPHWHU P  ʉN &DUULQJ &DSDFLW\ J   7HVW (TXLSPHQW .H\VLJKW(&Network Analyzer5 6&0:Comprehensive tester5 660%9%Signal Source $SULO$ ZZZEDWZLUHOHVVFRP       %$7:,5(/(66 5)/LQNGLDUDPRIPXOWLSUREHVSKHULFDOQHDUILHOGWHVWLQJV\VWHP    L 5) /LQN 2YHUYLHZ Q  $SULO$ ZZZEDWZLUHOHVVFRP  5) /LQN 2YHUYLHZ   5) /LQN RI 3DVVLYH PHDVXUHPHQW         %$7:,5(/(66 ZZZEDWZLUHOHVVFRP  $SULO$  96:5    5HWXUQ /RVV      %$7:,5(/(66  3HUIRUPDQFH 'DWD  3HUIRUPDQFH 'DWD ZZZEDWZLUHOHVVFRP   $SULO$  *DLQ   (IILFLHQF\      %$7:,5(/(66  )UHTXHQF\ 0+]      *DLQ G%L   (IILFLHQF\    Antenna Gain & Efficiency  5DGLDWLRQ 3DWWHUQV $SULO$ ZZZEDWZLUHOHVVFRP    ' 5DGLDWLRQ 3DWWHUQV      %$7:,5(/(66 $SULO$ ZZZEDWZLUHOHVVFRP   ' 5DGLDWLRQ 3DWWHUQV²0+]ǃ0+]     ' 5DGLDWLRQ 3DWWHUQV²0+]ǃ0+]      %$7:,5(/(66 BATWIRELESS S henzhenBatWirelessTechnologyCo,.Ltd Office Add澿Room 1301, 13th Floor, No. 8 Langhua Road, Xinshi Community, Dalang Street, Longhua District, Shenzhen Tel澿 Email澿 marketing@batwire…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 43 Report No.: HK2510145622-E FCC Test Report Test Report On Behalf of Zhuimeng Intelligent Technology (Dongguan) Co., Ltd. For massager Model No.: Vero FCC ID: 2BS2W-VERO Prepared For: Zhuimeng Intelligent Technology (Dongguan) Co., Ltd. Room 301, Building 11, No. 1 Xuefu Road, Songshan Lake Science and Technology Industrial Park, Dongguan City, Guangdong Province, China Prepared By: Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Oct. 10, 2025 ~ Nov. 10, 2025 Date of Report: Nov. 10, 2025 Report Number: HK2510145622-E Page 2 of 43 Report No.: HK2510145622-E Test Result Certification Applicant’s Name ................... : Zhuimeng Intelligent Technology (Dongguan) Co., Ltd. Address .................................... : Room 301, Building 11, No. 1 Xuefu Road, Songshan Lake Science and Technology Industrial Park, Dongguan City, Guangdong Province, China Manufacturer's Name ............. : Zhuimeng Intelligent Technology (Dongguan) Co., Ltd. Address .................................... : Room 301, Building 11, No. 1 Xuefu Road, Songshan Lake Science and Technology Industrial Park, Dongguan City, Guangdong Province, China Product Description Trade Mark ................................. : N/A Product Name ............................ : massager Model and/or Type Reference .. : Vero Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10: 2020 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of Performance of Tests ............... : Oct. 10, 2025 ~ Nov. 10, 2025 Date of Issue ............................................. : Nov. 10, 2025 Test Result ................................................. : Pass Testing Engineer Len Liao Technical Manager Sliver Wan Authorized Signatory Jason Zhou Page 3 of 43 Report No.: HK2510145622-E Contents Page 1 Summary ......................................................................................................................................................... 5 1.1 Test Procedures and Results .................................................................................................................... 5 1.2 Measurement Uncertainty ......................................................................................................................... 6 1.3 Information of the Test Laboratory ............................................................................................................ 6 2 General Information ....................................................................................................................................... 7 2.1 General Description of EUT ...................................................................................................................... 7 2.2 Description of Test Conditions .................................................................................................................. 9 2.3 Description of Test Setup ........................................................................................................................ 10 2.4 Description of Support Units .................................................................................................................... 11 3 Equipments List for All Test Items ............................................................................................................. 12 4 Test Result .................................................................................................................................................... 13 4.1 Antenna Requirement.............................................................................................................................. 13 4.2 AC Conduction Emissions Measurement ................................................................................................ 14 4.3 Radiated Emissions Measurement .......................................................................................................... 18 4.4 Maximum Peak Output Power Measurement ......................................................................................... 27 4.5 Power Spectral Density ........................................................................................................................... 28 4.6 6dB Bandwidth ........................................................................................................................................ 31 4.7 Occupied Bandwidth ................................................................................................................................ 34 4.8 Band Edge ............................................................................................................................................... 35 4.9 Conducted Spurious Emissions .............................................................................................................. 37 5 Test Setup Photos of the EUT .................................................................................................................... 41 6 Photos of the EUT ........................................................................................................................................ 43 Page 4 of 43 Report No.: HK2510145622-E ** Modified History ** Revision Description Issued Date Remark Revision 1.0 Initial Test Report Release Nov. 10, 2025 Jason Zhou Page 5 of 43 Report No.:…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Model: Vero Radiated Emission AC Conducted Emission RF Conducted Emission

Contact Information

Applicant

Xuan Qiu
[email protected]Fax: +86 18182122544

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.54 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Zhuimeng Intelligent Technology (Dongguan) Co., Ltd.

2BS2W-MIRA

massager

Dec 04, 2025

Equipment Class

DTS - Digital Transmission System