Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shenzhen PICEA Robotics Co., Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2025-12-17 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BS3VRB05A01 FRN: 0037642212 [Shenzhen PICEA Robotics Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Lin Yu Title: Certification Engineer Address: NO. 145 of Yuhu Road,Yulv Substrict, Yutang st., Guangming Dist., Shenzhen, China Tel.: +86 18825151523 Email: [email protected]
Shenzhen PICEA Robotics Co., Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2025-12-17 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BS3VRB05A01 FRN: 0037642212 [Shenzhen PICEA Robotics Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Lin Yu Title: Certification Engineer Address: NO. 145 of Yuhu Road,Yulv Substrict, Yutang st., Guangming Dist., Shenzhen, China Tel.: +86 18825151523 Email: [email protected]
TCB Authority to Act as Agent Page 1 of 1 Authority to Act as Agent Date: 2025-11-17 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Shenzhen PICEA Robotics Co., Ltd. / No.5 of Bldg.C1&C2&C3, No.145 of Yuhu Road, Yulv Subdistrict, Yutang st., Guangming Dist., ShenZhen Guangdong P.R. China For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 2025-11-17 Agreement is valid for 12 months from the above date. By: __________________________ Lin Yu (Signature) (Print name) Certification Engineer +86 18825151523 (Title) (Telephone) On behalf of: Shenzhen PICEA Robotics Co., Ltd. (Company Name)
Shenzhen PICEA Robotics Co., Ltd MS-0044715 Page 1 of 1 Revision 1 Date: 2025-12-15 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BS3VRB05A01 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photos Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup Photos Short Term Permanent User’s Manual Short Term Permanent Part List Shenzhen PICEA Robotics Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of specify number of days not to exceed 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _______________________________________________ _________Lin Yu_______________ (Signature/Title) (Print name) Tel: 86-18825151523 Email: [email protected]
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25GSDI 005 Auftrags-Nr.: Order no.: 168569215 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-08-11 Auftraggeber: Client: Shenzhen PICEA Robotics Co., Ltd. 101&201&301&401&501 of bldg.C6, bldg.C1&C2, No.5 of Bldg.C1&C2&C3, No.145 of Yuhu Road, Yulv Subdistrict, Yutang st., Guangming Dist., ShenZhen Guangdong P.R. China Prüfgegenstand: Test item: Dyson Spot+Scrub Ai Bezeichnung / Typ-Nr.: Identification / Type no.: RB05-A (Trademark: Dyson) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1091 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2025-06-25 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004035862-001,004 A004027463-002~003 Prüfzeitraum: Testing period: 2025-08-22 - 2025-09-05 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2025-11-25 Ausstellungsdatum: Issue date: 2025-11-25 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BS3VRB05A01 IC: 34846-RB05A01 HVIN: RB05-A Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Bell Hu Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25GSDI 005 Test report no.: Seite 2 von 10 Page 2 of 10 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Inf…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 1 of 33 Appendix A: Test Results of Bluetooth LE APPENDIX A: TEST RESULTS OF BLUETOOTH LE ............................................................................................................. 1 APPENDIX A.1: TEST RESULTS OF 6DB BANDWIDTH ................................................................................................................... 2 Test Result..................................................................................................................................................................... 2 Test Graphs ................................................................................................................................................................... 3 APPENDIX A.2: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................... 4 Test Result..................................................................................................................................................................... 4 Test Graphs ................................................................................................................................................................... 5 APPENDIX A.3: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ..................................................................................... 6 Test Result..................................................................................................................................................................... 6 Test Graphs ................................................................................................................................................................... 7 APPENDIX A.4: TEST RESULTS OF BAND EDGE MEASUREMENTS ................................................................................................... 8 Test Result..................................................................................................................................................................... 8 Test Graphs ................................................................................................................................................................... 9 APPENDIX A.5: TEST RESULTS OF CONDUCTED SPURIOUS EMISSION ............................................................................................ 10 Test Result................................................................................................................................................................... 10 Test Graphs ................................................................................................................................................................. 11 APPENDIX A.6: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ............................................................................................. 14 30 MHz - 1GHz ............................................................................................................................................................ 14 1GHz - 18GHz .............................................................................................................................................................. 16 APPENDIX A.7: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ............................................................................. 28 APPENDIX A.8: TEST RESULTS OF CONDUCTED EMISSION ON AC MAINS...................................................................................... 32 Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 2 of 33 Appendix A.1: Test Results of 6dB Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.512 2401.728 2402.240 0.5 PASS 2440 0.504 2439.732 2440.236 0.5 PASS 2480 0.508 2479.732 2480.240 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 3 of 33 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 4 of 33 Appendix A.2: Test Results of 99% Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.96600 2401.4992 2402.4652 --- PASS 2440 0.96363 2439.5016 2440.4652 --- PASS 2480 0.99154 2479.4873 2480.4788 --- PASS Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 5 of 33 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 6 of 33 Appendix A.3: Test Results of Conducted Power Spectral Density Test Result TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -4.23 ≤8.00 PASS 2440 -4.73 ≤8.00 PASS 2480 -5.66 ≤8.00 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 7 of 33 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 8 of 33 Appendix A.4: Test Results of Band Edge Measurements Test Result TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 3.01 -39.61 ≤-16.99 PASS High 2480 3.75 -38.73 ≤-16.25 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 9 of 33 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN25GSDI 003 Page 10 of 33 Appendix A.5: Test Results of Conducted Spurious Emission Test Result TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference 3.05 3.05 --- PASS 30~1000 3.05 -37.05 ≤-16.95 PASS 1000~26500 3.05 -28.44 ≤-16.95 PASS 2440 Reference 4.71 4.71 --- PASS 30~1000 4.71 -34.6 ≤-15.29 PASS 1000~26500 4.71 -26.67 ≤-15.29 PASS 2480 Reference 3.78 3…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 1 of 65 Appendix B: Test Results of 2.4GHz Wi-Fi APPENDIX B: TEST RESULTS OF 2.4GHZ WI-FI ................................................................................................................ 1 APPENDIX B.1: TEST RESULTS OF 6DB BANDWIDTH .................................................................................................................... 2 Test Result..................................................................................................................................................................... 2 Test Graphs ................................................................................................................................................................... 3 APPENDIX B.2: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................... 7 Test Result..................................................................................................................................................................... 7 Test Graphs ................................................................................................................................................................... 8 APPENDIX B.3: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ................................................................................... 12 Test Result................................................................................................................................................................... 12 Test Graphs ................................................................................................................................................................. 13 APPENDIX B.4: TEST RESULTS OF BAND EDGE MEASUREMENTS.................................................................................................. 17 Test Result................................................................................................................................................................... 17 Test Graphs ................................................................................................................................................................. 18 APPENDIX B.5: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS .......................................................................................... 21 Test Result................................................................................................................................................................... 21 Test Graphs ................................................................................................................................................................. 22 APPENDIX B.6: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ............................................................................................. 34 30MHz - 1GHz ............................................................................................................................................................. 34 1GHz - 18GHz .............................................................................................................................................................. 36 APPENDIX B.7: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ............................................................................. 48 Wi-Fi 802.11 b mode ................................................................................................................................................... 48 Wi-Fi 802.11 g mode ................................................................................................................................................... 52 Wi-Fi 802.11 n(HT20) mode ........................................................................................................................................ 56 Wi-Fi 802.11 n(HT40) mode ........................................................................................................................................ 60 APPENDIX B.8: TEST RESULTS OF CONDUCTED EMISSION ON AC MAINS ...................................................................................... 64 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 2 of 65 Appendix B.1: Test Results of 6dB Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 10.120 2406.920 2417.040 0.5 PASS 2437 10.080 2431.960 2442.040 0.5 PASS 2462 10.120 2456.920 2467.040 0.5 PASS 11G Ant1 2412 16.520 2403.720 2420.240 0.5 PASS 2437 16.560 2428.680 2445.240 0.5 PASS 2462 16.520 2453.680 2470.200 0.5 PASS 11N20SISO Ant1 2412 17.720 2403.080 2420.800 0.5 PASS 2437 17.640 2428.160 2445.800 0.5 PASS 2462 17.720 2453.120 2470.840 0.5 PASS 11N40SISO Ant1 2422 36.400 2403.760 2440.160 0.5 PASS 2437 36.480 2418.760 2455.240 0.5 PASS 2452 36.400 2433.760 2470.160 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 3 of 65 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 4 of 65 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 5 of 65 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 6 of 65 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 7 of 65 Appendix B.2: Test Results of 99% Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 15.872 2404.0351 2419.9071 --- PASS 2437 15.959 2428.9696 2444.9286 --- PASS 2462 15.995 2453.9537 2469.9487 --- PASS 11G Ant1 2412 17.169 2403.3423 2420.5113 --- PASS 2437 17.090 2…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 21 of 65 Appendix B.5: Test Results of Conducted Spurious Emissions Test Result TestMode Antenna Channel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 3.76 3.76 --- PASS 30~1000 3.76 -37.14 ≤-16.24 PASS 1000~26500 3.76 -28.31 ≤-16.24 PASS 2437 Reference 5.30 5.30 --- PASS 30~1000 5.30 -36.77 ≤-14.7 PASS 1000~26500 5.30 -28.12 ≤-14.7 PASS 2462 Reference 5.15 5.15 --- PASS 30~1000 5.15 -36.37 ≤-14.85 PASS 1000~26500 5.15 -27.4 ≤-14.85 PASS 11G Ant1 2412 Reference 1.65 1.65 --- PASS 30~1000 1.65 -36.38 ≤-18.35 PASS 1000~26500 1.65 -28.11 ≤-18.35 PASS 2437 Reference 0.29 0.29 --- PASS 30~1000 0.29 -37.43 ≤-19.71 PASS 1000~26500 0.29 -28.75 ≤-19.71 PASS 2462 Reference 0.04 0.04 --- PASS 30~1000 0.04 -37.56 ≤-19.96 PASS 1000~26500 0.04 -28.53 ≤-19.96 PASS 11N20SISO Ant1 2412 Reference 0.41 0.41 --- PASS 30~1000 0.41 -37.46 ≤-19.59 PASS 1000~26500 0.41 -28.01 ≤-19.59 PASS 2437 Reference 0.05 0.05 --- PASS 30~1000 0.05 -37.01 ≤-19.95 PASS 1000~26500 0.05 -28.73 ≤-19.95 PASS 2462 Reference -0.01 -0.01 --- PASS 30~1000 -0.01 -37.02 ≤-20.01 PASS 1000~26500 -0.01 -29.14 ≤-20.01 PASS 11N40SISO Ant1 2422 Reference -2.96 -2.96 --- PASS 30~1000 -2.96 -37.47 ≤-22.96 PASS 1000~26500 -2.96 -28.54 ≤-22.96 PASS 2437 Reference -2.59 -2.59 --- PASS 30~1000 -2.59 -37.72 ≤-22.59 PASS 1000~26500 -2.59 -28.42 ≤-22.59 PASS 2452 Reference -3.18 -3.18 --- PASS 30~1000 -3.18 -37.48 ≤-23.18 PASS 1000~26500 -3.18 -27.92 ≤-23.18 PASS Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 22 of 65 Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 23 of 65 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 24 of 65 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 25 of 65 11G_Ant1_2412_0~Reference 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 26 of 65 11G_Ant1_2437_0~Reference 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 27 of 65 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 28 of 65 11N20SISO_Ant1_2412_0~Reference 11N20SISO_Ant1_2412_30~1000 11N20SISO_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 29 of 65 11N20SISO_Ant1_2437_0~Reference 11N20SISO_Ant1_2437_30~1000 11N20SISO_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 30 of 65 11N20SISO_Ant1_2462_0~Reference 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 31 of 65 11N40SISO_Ant1_2422_0~Reference 11N40SISO_Ant1_2422_30~1000 11N40SISO_Ant1_2422_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 32 of 65 11N40SISO_Ant1_2437_0~Reference 11N40SISO_Ant1_2437_30~1000 11N40SISO_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 33 of 65 11N40SISO_Ant1_2452_0~Reference 11N40SISO_Ant1_2452_30~1000 11N40SISO_Ant1_2452_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 34 of 65 Appendix B.6: Test Results of Radiated Spurious Emissions Note: 1) This testing was carried out on different modulations, but only the worst case was presented in this report. 2) Testing was carried out within frequency range 9kHz to the tenth harmonics. The measurement results below 30MHz and 18GHz - 26.5GHz were greater than 20dB below the limit, so only the radiated spurious emissions from 30MHz to 18GHz were reported. 30MHz - 1GHz EUT Information EUT Name: Robot Vacuum Cleaner Model: RB05-A Test Mode: WIFI 2.4G_11b_Ch11 Order No/Sample No: A004027463-003 Test Voltage: Battery Remark: Temp 23 Humi:43% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 10 20 30 40 50 60 30M 5060 80100M200300400500 8001G Level in dBμV/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 45.706539 16.43 40.00 23.57 100.0 H 64.0 -18.8 104.167692 14.20 43.50 29.30 100.0 H 301.0 -18.9 243.922308 15.27 46.00 30.73 100.0 H 349.0 -17.6 625.020385 26.69 46.00 19.31 100.0 H 245.0 -9.2 742.502308 29.17 46.00 16.83 100.0 H 56.0 -7.2 Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 35 of 65 EUT Information EUT Name: Robot Vacuum Cleaner Model: RB05-A Test Mode: WIFI 2.4G_11b_Ch11 Order No/Sample No: A004027463-003 Test Voltage: Battery Remark: Temp 23 Humi:43% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 10 20 30 40 50 60 30M 5060 80100M200300400500 8001G Level in dBμV/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 30.149231 19.55 40.00 20.45 100.0 V 203.0 -23.0 55.331923 15.46 40.00 24.54 100.0 V 165.0 -18.6 104.988462 14.49 43.50 29.01 100.0 V 96.0 -18.9 227.469615 14.67 46.00 31.33 100.0 V 20.0 -18.3 426.618077 20.20 46.00 25.80 100.0 V 96.0 -13.2 625.020385 28.88 46.00 17.12 100.0 V 165.0 -9.2 850.620000 27.71 46.00 18.29 100.0 V 0.0 -5.4 Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN25GSDI 003 Page 36 of 65 1GHz…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25GSDI 003 Auftrags-Nr.: Order no.: 168569215 Seite 1 von 24 Page 1 of 24 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-08-11 Auftraggeber: Client: Shenzhen PICEA Robotics Co., Ltd. 101&201&301&401&501 of bldg.C6, bldg.C1&C2, No.5 of Bldg.C1&C2&C3, No.145 of Yuhu Road, Yulv Subdistrict, Yutang st., Guangming Dist., ShenZhen Guangdong P.R. Chi…
Text truncated - open the document above for the full version.
1435 Arapahoe Ave Boulder CO 80302 · Boulder, Colorado, 80302 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.30 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 154.20 mW |
| 3 | 15C | 2.42 GHz - 2.45 GHz | 155.20 mW |