FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ITP Technologies GmbH/
  3. 2BSB5-LZ1002010095

2BSB5-LZ1002010095rcB 2000, rcB 1400

ITP Technologies GmbH

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 24, 2025
Application Purpose
Original Equipment
Equipment Note
rcB 2000, rcB 1400
Frequency Range
2402.00000000 - 2480.00000000
Company
ITP Technologies GmbH
Country
Austria

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ITP Technologies GmbH Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2025-10-19 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BSB5-LZ1002010095 ITP Technologies GmbH (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, ______________________ Signature Printed Name: Philip Maier-Choc Title: Engineer Email: [email protected]

Attestation Statements

ITP Technologies GmbH Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2025-10-19 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BSB5-LZ1002010095 ITP Technologies GmbH (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely, ______________________ Signature Printed Name: Philip Maier-Choc Title: Engineer Email: [email protected]

Cover Letter(s)

TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 ITP Technologies GmbH Authority to Act as Agent Date: 2025-10-19 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with ITP Technologies GmbH, Ludersdorf 282, Ludersdorf-Wilfersdorf, 8200 Austria. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Agency Agreement Date: 2025-10-19 Agreement is valid for 12 months from the above date. Sincerely, ______________________ Signature Printed Name: Philip Maier-Choc Title: Engineer Email: [email protected]

Cover Letter(s)

ITP Technologies GmbH Difference description We ITP Technologies GmbH declare that our product rcB 1400(10020) and rcB 2000 (10095) are identical on circuitry design, PCB layout, electrical components used, internal wiring and functions, only different on the Battery Capacity and model’s name for marketing purpose. Here is difference between the 10020 and 10095. Product Name Model Battery Capacity rcB 1400 10020 DC 3.7V, 2800mAh rcB 2000 10095 DC 3.7V, 4000mAh Sincerely, ______________________ Signature Printed Name: Philip Maier-Choc Title: Engineer Email: [email protected]

ID Label/Location Info

Label location Label location 10095 10020

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25F1IZ 002 Auftrags-Nr.: Order no.: 168578210 Seite 1 von 7 Page 1 of 7 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-10-11 Auftraggeber: Client: ITP Technologies GmbH Ludersdorf 282, Ludersdorf-Wilfersdorf 8200, Austria Prüfgegenstand: Test item: rcB 2000, rcB 1400 Bezeichnung / Typ-Nr.: Identification / Type no.: 10095, 10020 (Trademark: LENZ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1093 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2025-10-16 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004065826-001~012 A004077747-001~003 Prüfzeitraum: Testing period: 2025-10-31 - 2025-11-05 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Lin Lin genehmigt von: authorized by: X Signed by: Hardy Suo Datum: Date: 2025-11-07 Ausstellungsdatum: Issue date: 2025-11-07 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BSB5-LZ1002010095 IC: 34630-L1002010095 HVIN: 10095, 10020 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25F1IZ 002 Test report no.: Seite 2 von 7 Page 2 of 7 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC …

Text truncated - open the document above for the full version.

Test Report

Confidential ITP Antenna (model 10020 & 10095) Revision: 00 Datasheet First Release: 19.11.2025 page 1 / 5 Project: 2506 Updated: xx.xx.xxxx Released/updated by: PMC File Name: ITP Antenna 10020_10095 Datasheet Rev00.docx History Release Date Rev. Modification Page Released by 19.11.2025 00 First Release all Philip Maier-Choč Content General Information ............................................................................................................. 2 Basic properties of a quarterwave monopole antenna ..................................................... 2 Determining the length of the printed monopole antenna ................................................. 2 Electrical Properties ............................................................................................................. 3 PCBA ................................................................................................................................... 4 Footprint ........................................................................................................................... 4 Schematic ........................................................................................................................ 4 Dimension ........................................................................................................................ 4 Layout .............................................................................................................................. 5 Manufacturer: ITP Technologies GmbH Ludersdorf 282, Ludersdorf-Wilfersdorf 8200, Austria Confidential ITP Antenna (model 10020 & 10095) Revision: 00 Datasheet First Release: 19.11.2025 page 2 / 5 Project: 2506 Updated: xx.xx.xxxx Released/updated by: PMC File Name: ITP Antenna 10020_10095 Datasheet Rev00.docx General Information Basic properties of a quarterwave monopole antenna A quarterwave monopole is a ground plane dependent antenna that must be fed single- ended. The antenna must have a ground plane to be efficient, and ideally the ground plane should spread out at least a quarter wavelength, or more, around the feed-point of the antenna. The size of the ground plane influences the gain, resonance frequency and impedance of the antenna. The length of the monopole PCB trace mainly determines the resonant frequency of the antenna, but because of the very wide gain bandwidth of a quarterwave monopole, the antenna length is not too critical. But like any other antenna types, the gain of a quarterwave monopole will vary if parameters in the surroundings, such as case/box materials, distance to the ground plane, size of the ground plane, width and thickness of the PCB trace are varied. If any of these parameters are changed, a retuning of the monopole PCB trace length may be necessary for optimum performance in each application. Determining the length of the printed monopole antenna The antenna is fabricated on a standard 1.0mm FR4 substrate material. Typical dielectric constant of about 4.4 at 2.45GHz. The width of the monopole trace is about W =0.9mm. The wavelength in free air is λ0 = 122mm. It may be approximated that the guided wavelength λg on the FR4 substrate is about λg=~0.75∗λ0 λg=0.75∗122mm λg=~92푚푚 The approximate, physical length of a printed quarterwave monopole antenna is then 푙= λg 4 푙= 92mm 4 =23푚푚 Confidential ITP Antenna (model 10020 & 10095) Revision: 00 Datasheet First Release: 19.11.2025 page 3 / 5 Project: 2506 Updated: xx.xx.xxxx Released/updated by: PMC File Name: ITP Antenna 10020_10095 Datasheet Rev00.docx Electrical Properties Frequency Range : 2400 – 2500MHz Operating Temperature : -40 to +125 °C 2.4GHz Frequency (MHz) Efficiency (dB) Efficiency (%) Peak Gain (dB) 2400 -2.61 54.82 3.91 2402 -2.59 55.09 3.96 2405 -2.68 53.94 3.79 2410 -2.70 53.71 3.79 2415 -2.65 54.37 3.78 2420 -2.60 54.93 3.83 2425 -2.64 54.39 3.86 2430 -2.70 53.65 3.75 2435 -2.72 53.45 3.70 2440 -2.74 53.18 3.62 2441 -2.74 53.16 3.68 2445 -2.74 53.16 3.62 2450 -2.72 53.41 3.51 2455 -2.77 52.80 3.55 2460 -2.73 53.33 3.54 2465 -2.63 54.54 3.59 2470 -2.63 54.55 3.60 2475 -2.58 55.17 3.52 2480 -2.55 55.64 3.68 2485 -2.61 54.88 3.55 2490 -2.58 55.22 3.64 2495 -2.65 54.35 3.59 2500 -2.67 54.03 3.59 Confidential ITP Antenna (model 10020 & 10095) Revision: 00 Datasheet First Release: 19.11.2025 page 4 / 5 Project: 2506 Updated: xx.xx.xxxx Released/updated by: PMC File Name: ITP Antenna 10020_10095 Datasheet Rev00.docx PCBA Footprint Schematic Dimension Trace Width : 0.914mm Antenna length : 23mm

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN25F1IZ 001 Auftrags-Nr.: Order no.: 168578210 Seite 1 von 21 Page 1 of 21 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-10-11 Auftraggeber: Client: ITP Technologies GmbH Ludersdorf 282, Ludersdorf-Wilfersdorf 8200, Austria Prüfgegenstand: Test item: rcB 2000, rcB 1400 Bezeichnung / Typ-Nr.: Identification / Type no.: 10095, 10020 (Trademark: LENZ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 RSS-247 Issue 3 August 2023 RSS-Gen Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2025-10-16 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004065826-001~012 A004077747-001~003 Prüfzeitraum: Testing period: 2025-10-26 - 2025-11-05 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Lin Lin genehmigt von: authorized by: X Signed by: Hardy Suo Datum: Date: 2025-11-07 Ausstellungsdatum: Issue date: 2025-11-07 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BSB5-LZ1002010095 IC: 34630-L1002010095 HVIN: 10095, 10020 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN25F1IZ 001 Test report no.: Seite 2 von 21 Page 2 of 21 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Philip Maier-Choc
[email protected]Fax: 00433112389090

Technical Contact

Go Global Compliance, Inc.Peter Merguerian
[email protected]

4454 Crabapple Ct., Tracy · Crabapple Ct., Tracy, California, 95377 · United States

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C2.40 GHz - 2.48 GHz900.00 µW15.2470000000
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted.