
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Important / Important 2-5 Exhaust ventilation 6 Ventilation dâĂ©chappement 7 Accessories / Accessoires 8 Installation guide / Manuel dâinstallation 9-13 Electrical connection 14 Raccordement Ă©lectrique 15 Automatic functions 16 Fonctions automatiques 17 Cleaning / Nettoyage 18-19 Warranty conditions 20 Conditions de garantie 21 FCC Statement 22 ISED Notice 23 Pin Code / Code dâidentification 24 EN / FR EN FR EN / FR EN / FR EN FR EN FR EN / FR EN FR EN EN/ FR EN/FR Fan / Ventilateur Norte 2 EN: Read this! EN IMPORTANT! - READ AND SAVE THESE INSTRUCTIONS. (UL) - FOR USE IN ONE- AND TWO- FAMILY DWELLING ONLY. (UL) - INSTALL IN INTERIOR WALL/CEILING. (CSA/UL) - For General Ventilating Use Only. (UL) - Acceptable for use over bathtub or shower when installed in GFCI protected branch circuit. (UL) - SUITABLE FOR CEILING INSTALLATION OVE TUB OR SHOWER. (CSA) - The fan is designed for fixed installation and must be installed by a qualified electrician. - To reduce the risk of injury to persons, install fan at least 2,1 m (7 Feet) above floor. (UL) - MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2,1 METERS ABOVE FLOOR OR GRADE LEVEL. (CSA) - Automatically operated device. To reduce the risk of injury disconnect from power supply before servicing. (UL) - Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. (UL) - FOR USE IN NON FIRE RATED INSTALLATIONS ONLY. (UL) - DO NOT INSTALL IN COOKING AREA. (CSA) - For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. CAUTION User and installation instructions / Instructions dâinstallation et dâutilisation 3 FR FR : Ă lire attentivement! IMPORTANT! - LIRE ET CONSERVER CES INSTRUCTIONS. (UL) - UTILISATION CONVENANT Ă UN LOGEMENT DâUNE OU DE DEUX FAMILLES SEULEMENT. (UL) - INSTALLER SUR UN MUR INTĂRIEUR OU AU PLAFOND. (CSA/UL) - Aux fins de ventilation gĂ©nĂ©rale seulement. (UL) - Utilisation acceptable au-dessus dâune baignoire ou dâune douche lorsque raccordĂ© Ă un circuit terminal protĂ©gĂ© par disjoncteur diffĂ©rentiel de fuite Ă la terre (DDFT). (UL) - CONVIENT Ă UNE INSTALLATION AU PLAFOND, AU-DESSUS DE LA BAIGNOIRE OU DE LA DOUCHE. (CSA) - Ce ventilateur a Ă©tĂ© conçu pour ĂȘtre utilisĂ© Ă un emplacement fixe et doit ĂȘtre installĂ© par un Ă©lectricien qualifiĂ©. - Pour rĂ©duire le risque de dommages causĂ©s Ă des personnes, installer le ventilateur Ă une hauteur dâau moins 2,1 m du sol. (UL) - INSTALLER DE FAĂON Ă DISPOSER LES PIĂCES LES MOINS MOBILES Ă UNE HAUTEUR DâAU MOINS 2,1 M DU PLANCHER OU DU SOL. (CSA) - Appareil Ă fonctionnement automatique. Pour rĂ©duire le risque de blessure, le dĂ©brancher du module dâalimentation avant dâen effectuer lâentretien. (UL) - Ne pas utiliser pour Ă©venter des matiĂšres dangereuses ou des substances et des vapeurs explosives. (UL) - UTILISATION ADAPTĂE UNIQUEMENT AUX INSTALLATIONS NON RĂSISTANTES AU FEU. (UL) - NE PAS INSTALLER DANS UNE AIRE DE CUISINE. (CSA) - Aux fins de ventilation gĂ©nĂ©rale seulement. Ne pas utiliser pour Ă©venter des matiĂšres dangereuses ou des substances et des vapeurs explosives. ATTENTION User and installation instructions / Instructions dâinstallation et dâutilisation 4 EN: Read this! EN WARNING â TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of ga- ses through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturerâs guideline and safety standards such as those published by the National Fire Protection Associa- tion (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors. e) If this unit is to be installed over a tub or shower, it must be marked as app- ropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) â protected branch circuit. WARNING â TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being swit- ched on accidentally. When the service disconnecting means cannot be locked, securely fasten aprominent warning device, such as a tag, to the service panel. WARNINGWARNING WARNINGWARNING User and installation instructions / Instructions dâinstallation et dâutilisation 5 FR FR : Ă lire attentivement! AVERTISSEMENT â POUR RĂDUIRE LES RISQUES DâINCENDIE, DâĂLECTROCUTION OU DE DOMMAGES CAUSĂS Ă DES PERSONNES, RESPECTER CE QUI SUIT : a) Les travaux dâinstallation et de cĂąblage Ă©lectrique doivent ĂȘtre effectuĂ©s par des personnes qualifiĂ©es conformĂ©ment Ă tous les codes et Ă toutes les normes applicables, notamment en matiĂšre de construction rĂ©sistante au feu. b) Une quantitĂ© suffisante dâair est nĂ©cessaire pour assurer une combustion et une Ă©vacuation adĂ©quates par lâĂ©chappement (la cheminĂ©e) des gaz provenant des appareils Ă combustion afin dâĂ©viter un contre-tirage. Suivre les directives et les normes de sĂ©curitĂ© du fabricant de lâappareil de chauffage comme celles publiĂ©es par la NFPA (National Fire Protection Association), lâASHRAE (American Society for Heating, Refrigeration and Air Conditioning Engineers) et les autoritĂ©s locales de rĂ©glementation. c) Ne pas endommager le filage Ă©lectrique et autre Ă©quipement non visible pendant la coupe ou le perçage dans un mur ou au plafond. d) Les ventilateurs de conduit doivent toujours ĂȘtre canalisĂ©s vers lâextĂ©rieur. e) Si cet âŠ
Text truncated - open the document above for the full version.
Volution Sweden AB * the applicant must designate a contact located in the United States for purposes of acting as the applicantâs agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 10/23/2025 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BSES1565-1 FRN of applicant: 0037543741 Per section 2.911(d)(7) of the FCC rules, Volution Sweden AB (âthe applicantâ) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: EMCTEK FCC Registration Number (FRN): 0037012671 Physical U.S. Company Address: 11788 Big Canyon Lane San Diego, CA 92131 United States Contact Person: Fang Liu Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Andreas Lofstrand Title: Manager Company Name: Volution Sweden AB Date: 10/23/2025 Agent Signed (if different from Applicant): Signed: Printed name: Fang Liu Title: Manager Company Name: EMCTEK Date: 10/23/2025
Volution Sweden AB Covered Equipment Certification Attestation Letter 10/23/2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BSES1565-1 Volution Sweden AB (âthe applicantâ) certifies that the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not âcoveredâ equipment. Volution Sweden AB (âthe applicantâ) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing âcoveredâ equipment. Volution Sweden AB (âthe applicantâ) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Andreas Lofstrand Title: Manager Company Name: Volution Sweden AB Date: 10/23/2025
DATE: 2025.10.23 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commissionâs regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Volution Sweden AB, Smedjegatan 10, SE 35246 VĂ€xjö, Sweden (Applicant Name and address) Name: Andreas Lofstrand Title: Manager Applicant Company: Volution Sweden AB
DATE: 2025.10.23 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commissionâs regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Volution Sweden AB, Smedjegatan 10, SE 35246 VĂ€xjö, Sweden (Applicant Name and address) Name: Andreas Lofstrand Title: Manager Applicant Company: Volution Sweden AB
DATE: 2025.10.23 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: __2BSES1565-1 __ Product Name: __Pax Norte ETL__ Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissionâs rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality â for example ...) âą Schematics âą Block diagram âą Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name: Andreas Lofstrand Title: Manager Company: Volution Sweden AB
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn Page 1 of 3 External Photos Page 2 of 3 Page 3 of 3
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn Page 1 of 1 Label and Label Location (The location of the red box.) 1.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn Page 1 of 6 Internal Photos Page 2 of 6 Page 3 of 6 Page 4 of 6 Page 5 of 6 Page 6 of 6 BT Antenna
Page 1 of 2 Report No.: CTC2025596503 CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF NoïŒCTC-TR-066_A2 For anti-fake verification, please visit the official website of China Inspection And Testing Society : yz.cncaq.com Maximum Permissible Exposure Evaluation FCC ID: 2BSES1565-1 According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b). EUT Specification Product Name: Pax Norte ETL Trade Mark: Pax Model/Type Reference: 1565-1 Listed Model(s): / Model Differences: / Frequency Band (Operating) BT: 2402MHz ~ 2480MHz Device Category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Exposure Classification Occupational/Controlled exposure (S=5mW/cm 2 ) General Population/Uncontrolled exposure (S=1mW/cm 2 ) Antenna Diversity Single antenna Multiple antennas TX diversity RX diversity TX/RX diversity Antenna Gain (Max) BT: 3.42dBi Evaluation Applied MPE Evaluation SAR Evaluation Page 2 of 2 Report No.: CTC2025596503 CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF NoïŒCTC-TR-066_A2 For anti-fake verification, please visit the official website of China Inspection And Testing Society : yz.cncaq.com Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) (A) Limits for Occupational/Controlled Exposure 300-1500 -- -- F/300 <6 1500-100000 -- -- 5 <6 (B) Limits for General Population/Uncontrolled Exposure 300-1500 -- -- F/1500 <30 1500-100000 -- -- 1 <30 Calculation Method Friis transmission formula: Pd=(P out *G)/(4*Pi*R 2 ) Where: Pd= Power density in mW/cm 2 P out = output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm Pd limit of MPE is 1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Mode Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Tune Up Tolerance (dB) Max. Tune Up Power (dBm) Power Density at 20cm (mW/cm 2 ) Limit (mW/cm 2 ) BLE 2402 3.42 0.29 ±1 1.50 0.0006 1 Note: 1. Calculate in the worst-case mode. 2. Max. Tune Up Power is declared by manufacturer, and used to calculate. 3. For a more detailed features description, please refer to the RF Test Report. **********************THE END**********************
Prepared by: Xu Ying Approved by: Xu Kai TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2021. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Applicant Espressif Systems Product ESP ANT B Model ESP ANT B Report No. Y2302A0204-T1 Issue Date March 22, 2023 Only For Volution Sweden AB/CTC Laboratories OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test Facility ....................................................................................................................... 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 3 2. General Description of Equipment Under Test .............................................................................. 4 2.1. Applicant and Manufacturer Information ............................................................................ 4 2.2. General Information ........................................................................................................... 4 2.3. Test Date ........................................................................................................................... 4 2.4. Received Date ................................................................................................................... 4 2.5. Applied Standards ............................................................................................................. 5 3. Test Conditions .............................................................................................................................. 6 3.1. Test Configuration ............................................................................................................. 6 3.2. Test Measurement ............................................................................................................. 6 4. Test Results ................................................................................................................................... 7 4.1. Gain and Efficiency ............................................................................................................ 7 4.2. Voltage Standing Wave Ratio (VSWR) .............................................................................. 8 4.3. Antenna S11 ...................................................................................................................... 9 5. Equipment List ............................................................................................................................. 10 ANNEX A: 2-D Pattern Plots .................................................................................................................... 11 ANNEX B: The EUT Appearance and Test Configuration........................................................................ 17 B.1 EUT Appearance ................................................................................................................... 17 B.2 Test Configuration ................................................................................................................. 19 Only For Volution Sweden AB/CTC Laboratories OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test Facility A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] 1.4. Laboratory Environment Temperature Min. =19°CïŒMax. = 25°C Relative humidity Min. =40%ïŒMax. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5Ω Only For Volution Sweden AB/CTC Laboratories OTA Test Report Report No: Y2302A0204-T1 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 19 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment Under Test 2.1. Applicant and Manufacturer Information Applicant Name Espressif Systems Applicant address #101, Block 2, 690 Bibo Road, Zhang Jiang High-Tech Park, Shanghai, China Manufacturer Name Espressif Systems ManufacturâŠ
Text truncated - open the document above for the full version.
CTC Laboratories, Inc. $CNAS$ CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF NoïŒCTC-TR-058_A2 For anti-fake verification, please visit the official website of China Inspection And Testing Society : yz.cncaq.com TEST REPORT Report No. .................................... : CTC2025596502 FCC ID ........................................... : 2BSES1565-1 Applicant ...................................... : Volution Sweden AB Address .......................................... : Smedjegatan 10, SE 35246 VĂ€xjö, Sweden Manufacturer..................................: Volution Sweden AB Address..........................................: Smedjegatan 10, SE 35246 VĂ€xjö, Sweden Product Name .............................. : Pax Norte ETL Trade Mark .................................... : Pax Model/Type reference .................... : 1565-1 Listed Model(s) .............................. : / Standard ....................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 Test Report Form No ..................... : CTC-TR-058_A2 Master TRF .................................... : Dated 2025-05-12 Date of receipt of test sample........: Sept. 18, 2025 Date of testing..............................: Sept. 18, 2025 to Sept. 29, 2025 Date of issue................................: Oct. 31, 2025 Result............................................: PASS Compiled by: (Printed name+signature) Jim Jiang Supervised by: (Printed name+signature) Eric Zhang Approved by: (Printed name+signature) Totti Zhao $è±ææŁæ”ç« $ $Totti$ This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The Test Result in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Page 2 of 41 Report No.: CTC2025596502 CTC Laboratories, Inc. Room 107, 108, 207, 208, 303 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF NoïŒCTC-TR-058_A2 For anti-fake verification, please visit the official website of China Inspection And Testing Society : yz.cncaq.com Table of Contents Page 1. TEST SUMMARY ....................................................................................................................................................... 3 1.1. TEST STANDARDS .......................................................................................................................................................... 3 1.2. REPORT VERSION ......................................................................................................................................................... 3 1.3. TEST DESCRIPTION ........................................................................................................................................................ 3 1.4. TEST FACILITY .............................................................................................................................................................. 4 1.5. MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 1.6. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 5 2. GENERAL INFORMATION .......................................................................................................................................... 6 2.1. CLIENT INFORMATION ................................................................................................................................................... 6 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6 2.3. ACCESSORY EQUIPMENT INFORMATION ............................................................................................................................ 7 2.4. OPERATION STATE ........................................................................................................................................................ 8 2.5. MEASUREMENT INSTRUMENTS LIST ................................................................................................................................. 9 3. TEST ITEM AND RESULTS ........................................................................................................................................ 11 3.1. CONDUCTED EMISSION................................................................................................................................................ 11 3.2. RADIATED EMISSION ................................................................................................................................................... 14 3.3. BAND EDGE EMISSIONS (RADIATED) .............................................................................................................................. 22 3.4. BAND EDGE AND SPURIOUS EMISSIONS (CONDUCTED) ...................................................................................................... 27 3.5. DTS BANDWIDTH ...........................................................................................................................âŠ
Text truncated - open the document above for the full version.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn Page 1 of 2 Radiated Measurements 30MHz - 1GHz Above 1GHz Page 2 of 2 Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |