FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SkyConnex Communications Limited/
  3. 2BSIICD-10

2BSIICD-10DIGITAL TWO WAY RADIO

SkyConnex Communications Limited
DIGITAL TWO WAY RADIO - FCC ID 2BSIICD-10 - SkyConnex Communications Limited
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Apr 24, 2026
Application Purpose
Original Equipment
Equipment Note
DIGITAL TWO WAY RADIO
Frequency Range
400.00000000 - 406.00000000
Company
SkyConnex Communications Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CD-10 OPERATION MANUAL a、Terminal Introduction 1、PTT key: Press this key and speak into the microphone when transmitting; release this key when receiving; 2、 Status Indicator Lights; 3、 Power On/Off Key: Short press to switch channel/volume mode; Long press to power on/off; 4、 Side Key 1: Its function can be set via programming software; 5、 Side Key 2: Its function can be set via programming software; Notes:  Side Keys 1 and 2 are used by default for adjusting volume and selecting channel when short-pressed. 1. When you power on the device, pressing Side Keys 1 and 2 can be used to adjust the volume. 2. After you turn on the device, press the PTT key once, then press the side key 1/2 to select the channel.  When you have set the function of Side Keys 1 and 2 via programming software, you need to long-press Side Keys 1 and 2 to activate this function. 6、 Charging Port: Connect the charging cable to charge the device; 7、 Programming (Headphone) Port: Can be used to connect an externally purchased headset, or to connect a programming cable to perform read/write operations on the walkie-talkie via PC software; connect a charging cable to charge the device; b、Features General Features 1、High/Low Power Switching Function 2、 Area 3、 Transmission Allow 4、 Scan List 5、 Squelch Level 6、 Timeout (TOT) 7、 Chinese/English Voice Broadcast Function 8、 Power Saving Function 9、 Scanning Function 1 PTT key 2 Status Indicator Lights 3 Power Key 4 Side Key 1 5 Side Keys 2 6 Charging Port 7 Programming (Headphone) Port 10、Voice-activated VOX function 11、 Battery Level Indicator 12、 Standalone Operation Function 13、 Low Battery Reminder 14、Read/Write Frequency Password 15、 Channel Lock 16、 Programmable Keys Numeric Section 1、Contacts 2、 Straight-through Dual Timeslot 3、 Color Code 4、 Digital Alarm Function 5、 Voice Encryption 6、 Voice One-Call 7、 Voice Group Call 8、 Voice All Call 9、 Remote Kill 10、 Activate 11、 Call Prompt 12、 Remote Monitoring 13、 Walkie-Talkie Detection Analog Section 1、QT/DQT sub-audio 2、 Wide/Narrow Band Selectable 3、 End-Sound Cancellation 4、 Monitoring Function Programmable Keys Can Be Set to the Following Functions 1、Area Switching 2、 Scan On/Off 3、 High/Low Power Selection 4、 Monitoring 5、 Battery Level Announcement 6、 Strict / Normal Squelch 7、 Voice Control On/Off 8、 Encryption On/Off 9、 Unused Channel (Temporary) Delete 10、 Repeater / Offline 11、 Standalone Operation On/Off (Standalone Operation must be checked on the overall device parameter page) 12、 All Alarm Tones On/Off 13、 Emergency Alarm On 14、 Emergency Alarm Off 15、 One-Touch 1 16、 One-Touch 2 17、 One-Touch 3 18、One-Touch 4 19、 One-Touch 5 20、 One-Touch 6 21、No 22、CheckInquire about Direct Dual Timeslot Status 23、 Channel Lock 24、 All Sub-tones On/Off c、 Features ■ Advanced Encrypted Communication Digital mode supports three advanced encryption algorithms: ARC4, AES128, and AES256, which can encrypt voice and data signals, effectively ensuring the privacy of calls and the security of information. d、Product Specifications Transmitter Output Power ≤1.2W Power Tolerance Variation +2/-3dB (extreme conditions) Transmit Frequency Error ±1.0ppm FSK Error <5% 4FSK transmit bit error rate ≤1×10⁻⁴ 4FSK modulation frequency deviation error ≤10.0% Occupied bandwidth (DMR) ≤8.5kHz Power Rise/Fall Time ≤1.5ms Adjacent channel power (ACPR) ≤-50dB @12.5KHz Transient switching adjacent channel power (ACTR) ≤-50dB @12.5KHz FM modulation 11K0F3E @12.5kHz 4FSK digital modulation 12.5KHz(data only):7K60FXD 12.5KHz(data+voice):7K60FXE Audio Distortion ≤3% @ 40% deviation Audio Response +1 ~ -3dB FM hum and noise 40dB @12.5KHz 45dB @25KHz Transmit Spurious Emissions ≤-36dBm(9kHz~1GHz) ≤-30dBm(1GHz~12.75GHz) Receiver Sensitivity (Analog) 0.2μV(FM @ 12dB SINAD) Sensitivity (Digital) 0.22μV(typ.) (@ 5% BER) Adjacent Channel Selectivity 60dB @ 12.5kHz Intermodulation Response Immunity 60dB @ 12.5kHz Blocking 84dB @ 12.5kHz Co-channel Rejection -12dB@ 12.5kHz Spurious Emission Response Immunity 65dB @ 12.5kHz Audio Output Power 1.0W / 16Ω Conducted Transmit Spurious Emissions <-57dBm(9kHz~1GHz) <-47dBm(1GHz~12.75GHz) General Specifications Frequency Range 400~470MHz Channel Spacing 12.5KHz Channel Capacity 256 Area Capacity 8 (Maximum 32 channels per area) Power Requirements 3.8V (rated) Battery 950mAh Operating Time (5/5/90 duty cycles, high power transmit) Analog: 6.7 hours; Digital: 7.4 hours Vocoder Type AMBE+2 Frequency Stability ±1.0ppm Antenna Impedance 50Ω Dimensions 67mm*32.5mm*27.5mm Weight Approximately 42g Note: The above indicators are based on ETSI standard tests. Availability varies depending on the laws and regulations of each country. Unless otherwise stated, all specifications shown are typical and are subject to change without notice. e、Accessories Magnetic charging cable (Code: 29K-ZGCDX-2066 Material: Magnetic charging cable Specification: 2P-2.84 pitch magnetic cable) / Charging cable (Code: 29K-ZG05V-2069 Material: Switching power supply charging cable (USB) Zhizhen Specification: 2 core wires, 1A current (USB3.1 Type C), 3.5mm wire thickness) (Choose one) Switching power supply (Code: 29K-0K158-2064 Material: Standard switching power supply plug Specification: K158 5V/1A (GFBA00500100WA)) Headphones (Code: 29E-VEEJX-0022 Material: Headphone cable_TYPE-C Specification: CA type (private network)) FCC STATEMENT: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. RF Exposure Statement: This radio complies with IEEE and ICNIRP exposure limits for occupational/controlled RF exposure environment at operating duty cycle of up to 50% and is authorized by the FCC for occupational/controlled use only. An appropriate warning label is affixed to all units. In order to comply with RF exposure requir…

Text truncated - open the document above for the full version.

External Photos

Report No.: AGC15733260102AP02 Page 1 of 5 EXTERNAL PHOTOS All View of EUT Top View of EUT Report No.: AGC15733260102AP02 Page 2 of 5 Bottom View of EUT Front View of EUT Report No.: AGC15733260102AP02 Page 3 of 5 Back View of EUT Left View of EUT Report No.: AGC15733260102AP02 Page 4 of 5 Right View of EUT Port-1 View of EUT Report No.: AGC15733260102AP02 Page 5 of 5 Adapter View of EUT ****************************************End of Report*************************************

Test Setup Photos

Report No.: AGC15733260102AP01 Page 1 of 2 TEST SETUP PHOTOS Radiated Emission Test Setup Below 1GHz Radiated Emission Test Setup Above 1GHz Report No.: AGC15733260102AP01 Page 2 of 2 Conducted Test Setup ****************************************End of Report*************************************

Test Report

Report No.: AGC15733260102FR01 Page 43 of 50 12.3 Measurement Procedure According to TIA/EIA-603 2.2.19 requirement, as for the product different from PTT, we use test steps as follows: 1. Connect DUT into Test discriminator and Storage Oscilloscope and keep DUT stats ON; 2. Input 1kHz signal into DUT; 3. Set the modulation domain analyzer to trigger on the rising edge of the waveform in order to capture a 4. single-shot turn-on of the transmitter signals; 5. Keep DUT in OFF state and Key the PTT; 6. Observe the stored oscilloscope of modulation domain analyzer. The signal trace shall be maintained within the allowable limits during the periods t1 and t2,and shall also remain within limits following t2; 7. Adjust the modulation domain analyzer to trigger on the falling edge of the transmitter waveform in order to capture a single-shot turn-off transmitter of the transmitter signal. 8. Keep the digital portable radio in ON state and unkey the PTT; 9. Observe the stored oscilloscope of modulation domain analyzer, The signal trace shall be maintained within the allowable limits during the period t3. 10. Set the signal generator to the assigned transmitter frequency and modulate it with a 1 kHz tone at ±12.5 kHz deviation and set its output level to -100dBm. 11. Turn on the transmitter. 12. Supply sufficient attenuation via the RF attenuator to provide an input level to the stored oscilloscope that is 40 dB below the maximum allowed input power when the transmitter is operating at its rated power 13. level. Note this power level on the stored oscilloscope as P0. 14. Turn off the transmitter. 15. Adjust the RF level of the signal generator to provide RF power equal to P0. This signal generator RF level shall be maintained throughout the rest of the measurement. 16. Remove the attenuation, so the input power to the stored oscilloscope is increased by 30 dB when the transmitter is turned on. 17. Adjust the vertical amplitude control of the stored oscilloscope to display the 1000 Hz at ±4 divisions vertically centered on the display. Set trigger mode of the Spectrum Analyzer to “Video”, and tune the “trigger level” on suitable level. Then set the “tiger offset” to -10ms for turn on and -15ms for turn off. 18. Turn on the transmitter and the transient wave will be captured on the screen of Spectrum Analyzer. 19. Observe the stored display. The instant when the 1 kHz test signal is completely suppressed is considered to be ton. The trace should be maintained within the allowed divisions during the period t1 and t2. 20. Then turn off the transmitter, and another transient wave will be captured on the screen of Spectrum Analyzer. The trace should be maintained within the allowed divisions during the period t3. Report No.: AGC15733260102FR01 Page 44 of 50  Describe limit line of transmitter frequency behavior:  ton: The switch-on instant ton of a transmitter is defined by the condition when the output power, measured at the antenna terminal, exceeds 0,1 % of the full output power (-30 dBc).  t1: period of time starting at ton and finishing according to above 11.1  t2: period of time starting at the end of t1 and finishing according to above 11.1  toff: switch-off instant defined by the condition when the output power falls below 0,1 % of the full output power (-30 dBc).  t3: period of time that finishing at toff and starting according to above 11.1 Report No.: AGC15733260102FR01 Page 45 of 50 12.4 Measurement Result 12.5 kHz Channel Separation, Analog modulation, Assigned Frequency:406.125MHz-Turn On 12.5 kHz Channel Separation, Analog modulation, Assigned Frequency:406.125MHz-Turn Off Note: All the test frequencies was tested, but only the worst data be recorded in this part. Report No.: AGC15733260102FR01 Page 46 of 50 13. Audio Low Pass Filter Response 13.1 Provisions Applicable 2.1047(a): Voice modulated communication equipment. A curve or equivalent data showing the frequency response of the audio modulating circuit over a range of 100 to 5000 Hz shall be submitted. For equipment required to have an audio low-pass filter, a curve showing the frequency response of the filter or of all circuitry installed between the modulation limiter and the modulated stage shall be submitted. ANSI TIA/EIA 603-E:2016 3.2.15: Recommended audio filter attenuation characteristics are given below: For audio frequencies above 3000 Hz, the audio response of the post limiter low-pass filter shall meet or exceed the following requirements: a) For equipment operating on 20, 25 or 30 kHz channel bandwidth in the 25 MHz to 174 MHz range: At frequencies from 3000 Hz through 15,000 Hz the attenuation shall be greater than the attenuation at 1000 Hz by at least: 40 log10 (f / 3000) dB where: f is the audio frequency in Hz. At frequencies above 15,000 Hz, the attenuation shall be greater than the attenuation at 1000 Hz, by at least: 28 dB. b) For equipment operating with 25 kHz bandwidth channels between 406 and 512 MHz through 896 MHz, and between 929 MHz through 930 MHz: At frequencies from 3000 Hz through 20,000 Hz, the attenuation shall be greater than the attenuation at 1000 Hz by at least: 60 log10 (f / 3000) dB where: f is the audio frequency in Hz. At frequencies above 20,000 Hz the attenuation shall be greater than the attenuation at 1000 Hz by at least: 50 dB. c) For equipment operating on channels between 896 MHz through 901 MHz, between 935 MHz through 940 MHz, and 12.5 or 15 kHz spaced channels in the frequency range 138-174 MHz and 406-512 MHz. At frequencies from 3000 Hz through 20,000 Hz the attenuation shall be greater than the attenuation at 1000 Hz by at least: 100 log10 (f / 3000) dB where: f is the audio frequency in Hz. Report No.: AGC15733260102FR01 Page 47 of 50 13.2 Measurement Procedure The rated audio input signal was applied to the input of the audio low-pass filter (or of all modulation stages) using an audio oscillator, this input signal level and its corresponding output signal were then me…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 50 FCC Test Report FCC ID : 2BSIICD-10 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : DIGITAL TWO WAY RADIO BRAND NAME : MOHANTON, LISHENG, YSHON MODEL NAME : CD-10, D313, D2128, D325, D315, D317 APPLICANT : SkyConnex Communications Limited DATE OF ISSUE : Mar. 02, 2026 STANDARD(S) : FCC Part 90 Subpart I REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC15733260102FR01 Report No.: AGC15733260102FR01 Page 2 of 50 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Mar. 02, 2026 Valid Initial Release Report No.: AGC15733260102FR01 Page 3 of 50 Table of Contents 1. General Information ........................................................................................................................................ 5 2. Product Information ........................................................................................................................................ 6 2.1 Product Technical Description ................................................................................................................... 6 2.2 Test Frequency List ................................................................................................................................... 7 2.3 Related Submittal(S) / Grant (S) ............................................................................................................... 8 2.4 Test Methodology ...................................................................................................................................... 8 2.5 Calculation of Emission Indicators ............................................................................................................ 8 2.6 Special Accessories .................................................................................................................................. 8 2.7 Equipment Modifications ........................................................................................................................... 8 3. Test Environment ............................................................................................................................................ 9 3.1 Address of The Test Laboratory ................................................................................................................ 9 3.2 Test Facility ................................................................................................................................................ 9 3.3 Environmental Conditions ....................................................................................................................... 10 3.4 Measurement Uncertainty ....................................................................................................................... 10 3.5 List of Equipment Used ........................................................................................................................... 11 4.System Test Configuration ............................................................................................................................ 12 4.1 EUT Configuration ................................................................................................................................... 12 4.2 EUT Exercise ........................................................................................................................................... 12 4.3 Configuration of Tested System .............................................................................................................. 12 4.4 Equipment Used in Tested System ......................................................................................................... 12 4.5 Summary of Test Results ........................................................................................................................ 13 5. Description of Test Modes ........................................................................................................................... 14 6. Frequency Stability ....................................................................................................................................... 15 6.1 Provisions Applicable .............................................................................................................................. 15 6.2 Measurement Procedure ......................................................................................................................... 15 6.3 Measurement Setup ................................................................................................................................ 15 6.4 Measurement Result ............................................................................................................................... 16 7. 26dB Emission Bandwidth and 99% Occupied Bandwidth ...................................................................... 17 7.1 Provisions Applicable .............................................................................................................................. 17 7.2 Measurement Procedure ......................................................................................................................... 17 7.3 Measurement Setup ................................................................................................................................ 17 7.4 Measurement Result ............................................................................................................................... 18 8. Spurious Radiated Emission ......................................................................................................................... 21 8.1 Provisions Applicable .............................................................................................................................. 21 8.2 Measurement Procedure .............................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 44 SAR Test Report Report No.: AGC15733260102FH01 FCC ID : 2BSIICD-10 PRODUCT DESIGNATION : DIGITAL TWO WAY RADIO BRAND NAME : MOHANTON , LISHENG , YSHON MODEL NAME : CD-10, D313, D2128, D325, D315, D317 APPLICANT : SkyConnex Communications Limited DATE OF ISSUE : Mar. 12, 2026 STANDARD(S) : IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2019 REPORT VERSION : V1.0 Attestation of Global Compliance(Shenzhen) Co., Ltd. Report No.: AGC15733260102FH01 Page 2 of 44 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Mar. 12, 2026 Valid Initial Release Report No.: AGC15733260102FH01 Page 3 of 44 Test Report Applicant Name SkyConnex Communications Limited Applicant Address Room 3601, 36/F Lippo Centre, Tower Two, 89 Queensway, Hong Kong Manufacturer Name Lisheng Communications Co., Ltd. Manufacturer Address 5#, Chongxiang St., Econ & Tech. Area, Quanzhou, Fujian, China Factory Name Lisheng Communications Co., Ltd. Factory Address 5#, Chongxiang St., Econ & Tech. Area, Quanzhou, Fujian, China Product Designation DIGITAL TWO WAY RADIO Brand Name MOHANTON , LISHENG , YSHON Test Model CD-10 Series Model D313, D2128, D325, D315, D317 Declaration of Difference Except for the model name and trademark, everything else is identical. EUT Voltage DC 3.85V Applicable Standard IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2019 Date of receipt of test item Jan. 15, 2026 Test Date Jan. 30, 2026 Report Template AGCRT- US -PTT/SAR (2021-04-20) Note: The results of testing in this report apply to the product/system which was tested only. Prepared By Bibo Zhang (Project Engineer) Mar. 12, 2026 Reviewed By Jack Gui (Reviewer) Mar. 12, 2026 Approved By Angela Li (Authorized Officer) Mar. 12, 2026 Report No.: AGC15733260102FH01 Page 4 of 44 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ......................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................... 6 2.1. EUT DESCRIPTION......................................................................................................................................... 6 3. SAR MEASUREMENT SYSTEM ........................................................................................................................ 7 3.1. THE DASY5 SYSTEM USED FOR PERFORMING COMPLIANCE TESTS CONSISTS OF FOLLOWING ITEMS .................... 7 3.2. DASY5 E-FIELD PROBE ................................................................................................................................. 8 3.3. DATA ACQUISITION ELECTRONICS DESCRIPTION ............................................................................................... 8 3.4. ROBOT .......................................................................................................................................................... 9 3.5. LIGHT BEAM UNIT .......................................................................................................................................... 9 3.6. DEVICE HOLDER .......................................................................................................................................... 10 3.7. MEASUREMENT SERVER ............................................................................................................................... 10 3.8. PHANTOM ................................................................................................................................................. 11 4. SAR MEASUREMENT PROCEDURE ............................................................................................................ 12 4.1. SPECIFIC ABSORPTION RATE (SAR) .............................................................................................................. 12 4.2. SAR MEASUREMENT PROCEDURE ................................................................................................................ 13 5. TISSUE SIMULATING LIQUID ....................................................................................................................... 15 5.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID..................................................................................... 15 5.2. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS ............................................................... 15 5.3. TISSUE CALIBRATION RESULT ....................................................................................................................... 16 6. SAR SYSTEM CHECK PROCEDURE ........................................................................................................... 17 6.1. SAR SYSTEM CHECK PROCEDURES ............................................................................................................. 17 6.2. SAR SYSTEM CHECK ................................................................................................................................... 18 7. EUT TEST POSITION ...................................................................................................................................... 19 7.1. BODY WORN POSITION ................................................................................................................................ 19 8. SAR EXPOSURE LIMITS ............................................................................................................................... 20 9. TEST FACILITY .............................................................................................................................................. 21 10. TEST EQUIPMENT LIST .............................................................................................................................. 22 11. MEASUREMENT UNCERTAINTY ..........................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 18 CALIBRATION DATA PROBE CALIBRATION DATA Page 2 of 18 Page 3 of 18 Page 4 of 18 Page 5 of 18 Page 6 of 18 Page 7 of 18 Page 8 of 18 Page 9 of 18 Page 10 of 18 DAE CALIBRATION DATA Page 11 of 18 Page 12 of 18 Page 13 of 18 DIPOLE CALIBRATION DATA Page 14 of 18 Page 15 of 18 Page 16 of 18 Page 17 of 18 Page 18 of 18

Internal Photos

Report No.: AGC15733260102AP02 Page 1 of 6 INTERNAL PHOTOS Open View-1 of EUT Open View-2 of EUT Report No.: AGC15733260102AP02 Page 2 of 6 Internal View-1 of EUT Internal View-2 of EUT Report No.: AGC15733260102AP02 Page 3 of 6 Internal View-3 of EUT Internal View-4 of EUT UHF Antenna Report No.: AGC15733260102AP02 Page 4 of 6 Internal View-5 of EUT Internal View-6 of EUT Report No.: AGC15733260102AP02 Page 5 of 6 Internal View-7 of EUT Internal View-8 of EUT Report No.: AGC15733260102AP02 Page 6 of 6 Internal View-9 of EUT Internal View-10 of EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID Label Location 40mm*50mm FCC ID: 2BSIICD-10

Attestation Statements

2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: SkyConnex Communications Limited Address: Room 3601, 36/F Lippo Centre, Tower Two, 89 Queensway, Hong Kong FCC ID: 2BSIICD-10 Date: Mar. 02, 2026 2.911(d)(7) USA Designated Agent for Service of Process We, [SkyConnex Communications Limited] (“the applicant”) designate [Wedo Group] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Wedo Group Address: 710 Arabian Ln Walnut, CA 91789, United States FRN:0037730611 Contact Name: Jeffrey Chen Telephone No: (323) 528-1888 Email: [email protected] Applicant Company name: SkyConnex Communications Limited Address: Room 3601, 36/F Lippo Centre, Tower Two, 89 Queensway, Hong Kong FRN: 0037548153 Contact Name: Stone He Telephone No: +852-8404-7998 Email: [email protected] Signature: Signature:

Cover Letter(s)

SkyConnex Communications Limited Room 3601, 36/F Lippo Centre, Tower Two, 89 Queensway, Hong Kong Date:2026-04-17 FCC Part 90 Letter FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Declaration of compliance to the requirements of §90.203 FCC ID: 2BSIICD-10 Dear Sir/Madam, We, SkyConnex Communications Limited, acknowledge that this device will not be marketed to USA users with the frequency band which is not allowed by rule part 90.and it is a violation of FCC rules if this device is operated on unauthorized frequencies inside the U.S.A. This equipment meets the requirements of the FCC Rules, Parts 90.203(e) and (g), as applicable. Programming of this product transmit frequencies can be performed ONLY by the manufacturer or by service or by maintenance personal. The operator can’t program transmit frequencies using the equipment’s external operation controls. This is to certify that the requirements of 47 CFR Part 90.203(j)(4) and (5) spectrum efficiency are met by the SkyConnex Communications Limited demonstrated by the tests conducted on the sample radio provided. The tests show that the 4FSK data rate is in accordance with ETSI TS 102 361-1, that is 9600 bits per second in a 12.5 kHz bandwidth to satisfy the data rate requirement of 4800 bits per second per 6.25 kHz of channel bandwidth (7K60F1D emissions). Additionally, the radio uses the AMBE+2 half-rate vocoder to compress 60ms of normal bursts are sent in alternate 30ms TDMA slots and so comply with the equivalence of one voice channel per 6.25 kHz bandwidth (7K60F1W emission). Additionally, the radio also meets the requirement of one voice channel per 12.5 kHz of channel bandwidth for analogue speech (11k0F3E emission). Sincerely Yours, Signature: Name: Stone He Title: Manager

Cover Letter(s)

SkyConnex Communications Limited Room 3601, 36/F Lippo Centre, Tower Two, 89 Queensway, Hong Kong Date: 2026-04-17 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Extended Frequencies Justification for Certification of Transmitter FCC ID: 2BSIICD-10 Dear Sir/Madam, This transmitter was designed to o…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Stone. He
[email protected]Fax: /

Technical Contact

Wedo GroupJeffrey Chen
[email protected]

710 Arabian Ln · Walnut, California, 91789 · United States

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
19400 MHz - 406 MHz1.1092 W9K94F3E2.5ppm
29406.1 MHz - 470 MHz1.1092 W9K94F3E2.5ppm
39400 MHz - 406 MHz1.1324 W6K97F1D2.5ppm
49406.1 MHz - 470 MHz1.1324 W6K97F1D2.5ppm
59400 MHz - 406 MHz1.1324 W6K97F1W2.5ppm
69406.1 MHz - 470 MHz1.1324 W6K97F1W2.5ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Limbs and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 0 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR levels for Body-worn accessories and Limbs (10g-extremity SAR) exposure conditions are 0.17 W/kg and 0.74 W/kg, respectively when operating at 50% Duty Cycle.