FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Fuan Yinmeijia Trading Co., Ltd./
  3. 2BSO8-YMJ-A7

2BSO8-YMJ-A7Massage Chair

Fuan Yinmeijia Trading Co., Ltd.
Massage Chair - FCC ID 2BSO8-YMJ-A7 - Fuan Yinmeijia Trading Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 25, 2025
Application Purpose
Original Equipment
Equipment Note
Massage Chair
Frequency Range
2402.00000000 - 2480.00000000
Company
Fuan Yinmeijia Trading Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Massage Chair Us er Manual Thank you for purchasing our massager product. This massage chair adopts ergonomic design to achieve massage of the back, waist, buttocks, legs, arms and other parts. It has a variety of massage methods, warm - compress, air - bag squeeze massage and other functions. It is a high - end luxury massage chair. Before use, please read this manual carefully and pay special attention to the safety precautions to ensure correct operation and use of this product. Keep the user manual in a safe place so that you can refer to it when necessary. Tableofcontents ☀S afetyPrecautions....................................................................................................................................................01-04 ☀ Productparametersandmaincomponents......................................................05 ☀MassageChairPlacement.............................................................................................................06 ☀ Instructionsbeforeuse................................................................................................................................... 07-09 ☀ MassageChairInstallation................................................................................................................10-11 ☀ MassageProgramOperationInstructions........................................................12-13 ☀ MaintenanceandRepair....................................................................................................................................14 ☀ After-salesservice................................................................................................................................................................15 13 Thisproductmustbegrounded.Intheeventofamalfunction,groundingcan reducetheriskofelecric shock.-Beforeuse,pleasemakesurethatthelocal powersupplyvoltageandfrequencyareconsistentwiththeratedvoltage parametersofthemachine. PleasedonotuseapowersupplyotherthanAC110V. Pleasestopusingifthepowercordandpowerplugaredamagedorthe socket connectorisbose.-Lifthecapebeforeusingthemassagechairto checkwhetherthefabricinthecenterofthebackcushionandthe urroundingleatherarecacked. Beforeinsertingthepowerplugintothesocket,pleasemakesurethatthe main powerswitchisinthe"off"state. Pleasefullyinsertthepowerplugintothesockettoensuregoodcontact.-Before use,pleasetumonallswitchesinsequenceaccordingtotheinstructionsto confirmthatthemachineisoperatingnormally. Forsafetyreasons,pleaseadjustthepositionofthemassageballbeforeuse andthensitdownslowly。 Pleasereadthesafetyprecautionscarefullybeforeusetousethemassage chaircorrecty.Inordertoavoidcausingphysicalorpropertydamagetothe userandothers,thisinstructionmanualcontainsimportantcontents,please readcarefully. Prohibition aMandatory PowerGrounding Prohibition Mandatory Precautionsforuseenvironment Donotusethemassagechairinahumiderwvironment(suchasabathroom orsauna)toavoidaccidentssuchaselectricshockcaused bymoisture. Donotusethemassagechairinanenvironmentwheretheroom temperatureisabove40degreesCelsius. Donotplacethemassagechairnearaheaterorstove,asthismaycause thepartsinsidethemassagechairtooverheatandcauseafire. Pleaseplacethemassagechaironaflatsurfacetoavoidaccidentssuchas tippingover. Donotusethemassagechairiftheleathercoverisdamaged. PrecautionsBeforeuse Prohibition Pleasedonotusethefollowing: Prohibition Iftheuserhasthefollowingconditions,pleaselistentothedoctor'sadviceand instructionsbeforeuse AMandatory Mandatory Donotusethisproductwithothertherapeuticdevicesorelectricblankets. Donotmovethemassagechairwhensomeoneissittingonit. Donotsitdirectlyonthemassagechairaftersteppingonthefootrest. Donotuseaccessoriesotherthantheaccessorieswhenusingthisproduct. Usergroups Peoplewhocannotmassageaccordingtodoctor'sadvice,such as:thrombosis,severeaneurysm,acutevaricosevein,variousskin inflammationsandskininfections. Peoplesuspectedofacutecervical spondylosisandheadtremor. Thosewhoarereceivingtreatmentorfeelabnormal Havemalignanttumors Womenwhoarepregnantorhavejustbeenpregnant, Haveunhealedskinandboneinjuriesontheirfeet Peopleneedtorest Whenyouhaveahighfeverandareveryweak Peoplewithseveresensoryimpairmentoftheperipheralnervoussystem causedbydiabetes,peoplewithheartdiseaseorimplantedmedicalelectrical devicessuchaspacemakers, Patientswithabnormalortwistedspines,andpeoplewhohavefracturesin relatedpartsthathavenothealed Eveniftherearenoobvioussymptoms,theelderlyorpeoplewith osteoporosisneedtoconsultadoctorbeforeuse.-Thismachinehasa heatingfunction,andthesurfaceofthedeviceishot Peoplewhoaresensitivetoheatshouldbecarefulwhenusingit Precautionsforuse Beforeloweringthestand,makesurethattherearenochildrenorpetsplaying underthestandtoavoidtheriskof injury. Whenadjustingthebackrestangle,makesurethattherearenopeopleor obstaclesbehindthe unitandthatthereisenoughspacebeforeadjusting. Donotplaceanyobjectsbehindthebackrestandunderthestand. Donoterectthewholebodyforceontheroller,duringtheuseoffootmassage,so asnottodamagethefunctionoffootmassage. Donotallowinfantsandchidrentouseorplayonthemassagechairtoavoid therisk ofinjury. Donotusethemassagechairwhen yourbodyiswet.-Donotuseitnakedto avoidtheriskofinjury. Donotuseitwhenwearnghardheadwearorwithyourhairdrapedoveryour back,asthemovementofthemassagewheelmaycausethehairtobepulledand causenjury. Donotbend,control,ortwistthepowercordorplaceheavyobjects onthepowercordorpowerplug. Donotuseitwhenthesocketisloosetoavoidsparks,short circuits,etc.causedbypoorcontact,eadingto accidents Donotputyourhandsintotheworkingpartsofthemassagechairtoavoidthe riskofinjury. Donotsitonthebackrest,armrestsorfootresttoavoidinjuriesduetounstable centerofgravityordamageto relatedparts. Donotuseitforalongtimetoavoidexcessivestimulationofmusclesand nerves.Itis recommendedtouseitfor15-20minuteseachtime.Donotputyour fingersintothemetalpartsundertheseattoavoidtheriskofnjury. Donotpresshardorplacehardobjectsonthemovingpartsofthemassagewheel toavoidmachinemalfunction. Prohibition Note Dono…

Text truncated - open the document above for the full version.

Attestation Statements

FuanYinmeijiaTradingCo.,Ltd. Address:No.668XueyuanRoad,FuanCity,FujianProvinceChina. Date:2025-11-19 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BSO8-YMJ-A7,FRN:0037610797 FuanYinmeijiaTradingCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication, ANTEKSERVICEINCisourdesignatedU.S.agentforserviceofprocessfortheabove referencedFCCID.FuanYinmeijiaTradingCo.,Ltd.acceptstomaintainanagentfornoless thanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanyCommission-relatedproceedinginvolvingtheequipment. ANTEKSERVICEINCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:ANTEKSERVICEINC Address:901NPENNSYLVANIASTSTE0DENVERCO80203UnitedStates FRN:0033437609 ContactPerson:ShirleyKwok Tel.:(303)800-6306 Email:[email protected] Sincerely, SignedonbehalfofSignedonbehalfof FuanYinmeijiaTradingCo.,Ltd. ANTEKSERVICEINC Name:WenbinXueName:ShirleyKwok Title:ManagerTitle:Manager Signature:Signature: Date:2025-11-19Date:2025-11-19

Attestation Statements

Rev1/26/2023 FuanYinmeijiaTradingCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025-11-19 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BSO8-YMJ-A7 FuanYinmeijiaTradingCo.,Ltd.certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. FuanYinmeijiaTradingCo.,Ltd.certifiesthattheequipmentforwhichauthorizationissoughtdoesnot includecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature) (WenbinXue) Rev1/26/2023 FuanYinmeijiaTradingCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025-11-19 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:FCCID:2BSO8-YMJ-A7 FuanYinmeijiaTradingCo.,Ltd.certifiesthat,asofthedateofthefilingoftheapplication,theapplicant isnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates) asanentityproducing“covered”equipment. Sincerely, (Applicantsignature) (WenbinXue)

Cover Letter(s)

Zhuhai Jieli Technology Co., LTD Zhuhai Jieli Technology Co., LTD 333 Kexing Road, Xiangzhou District, Zhuhai City Type Antenna PCB Antenna Zhuhai Jieli Technology Co., LTD 333 Kexing Road, Xiangzhou District, Zhuhai City Zhuhai Jieli Technology Co., LTD 333 Kexing Road, Xiangzhou District, Zhuhai City

Cover Letter(s)

FuanYinmeijiaTradingCo.,Ltd. Date:11/19/2025 ProductModelNumber:YMJ-A7,YMJ-A8,YMJ-A9,YMJ-A10,YMJ-A17, YMJ-A18,YMJ-19,YMJ-A20,YMJ-A27,YMJ-A28,YMJ-A29,YMJ-A30 FCCID:2BSO8-YMJ-A7 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: Title:Manager Email:[email protected] Telephone:19925803635 Onbehalfof:FuanYinmeijiaTradingCo.,Ltd.

Cover Letter(s)

FuanYinmeijiaTradingCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2025/11/19 Subject;RequestforConfidentiality FCCID:2BSO8-YMJ-A7 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Nam e:WenbinXue Title: Manager

Cover Letter(s)

FuanYinmeijiaTradingCo.,Ltd. ProductSimilarityDeclaration Productname:MassageChair Modelname:YMJ-A7,YMJ-A8,YMJ-A9,YMJ-A10,YMJ-A17, YMJ-A18,YMJ-19,YMJ-A20,YMJ-A27,YMJ-A28,YMJ-A29,YMJ-A30 FCCID:2BSO8-YMJ-A7 We(FuanYinmeijiaTradingCo.,Ltd.)herebystatethatallthe modelsareelectricalidenticalincludingthesamesoftware parameterandhardwaredesign(i.e.,circuitdesign,PCBLayout, RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureand design(includingproductenclosure,materials,etc.,),theonly differenceisthemodelname. Signature: Name:WenbinXue Title:Manage Place,date:Shenzhen,2025.11.19

External Photos

FCCID:2BSO8-YMJ-A7ExternalEUTphotos

ID Label/Location Info

Size:20cm*10cm

Internal Photos

FCCID:2BSO8-YMJ-A7InternalEUTphotos BTAnt

RF Exposure Info

FCCID:2BSO8-YMJ-A7 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 , UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≤50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≤3.0for1-gSAR,and≤7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, SoaSARtestisnotrequired ModeFreque ncy (MHz) Max Power (dBm) Target power W/ tolerance (dBm) Maxtune uppower tolerance (dBm) Max Power (mW) Min. Distanc e (mm) Calc. threshol ds limit GFSK 24020.26 0 ± 1 11.25895.000.39023.0 2441-0.01 0 ± 1 11.25895.000.39343.0 2480-0.140±111.25895.000.39653.0 Π /4-DQ PSK 24021.021±121.58495.000.49133.0 24410.78 1 ± 1 21.58495.000.49523.0 24800.62 1 ± 1 21.58495.000.49923.0 8DPSK 24021.521±121.58495.000.49133.0 24411.27 1±1 21.58495.000.49523.0 24801.13 1 ± 1 21.58495.000.49923.0

Test Report

FCCID:2BSO8-YMJ-A7 TableofContents 1.DutyCycle.....................................................................................................................................................................2 2.-20dBBandwidth..........................................................................................................................................................7 3.99%OccupiedBandwidth..........................................................................................................................................12 4.PeakOutputPower.....................................................................................................................................................17 5.SpuriousEmissions.....................................................................................................................................................22 6.Bandedge....................................................................................................................................................................31 7.CarrierFrequenciesSeparation(Hopping).................................................................................................................44 8.NumberofHoppingChannel(Hopping)....................................................................................................................49 9.DwellTime(Hopping).................................................................................................................................................51 Page2of59 FCCIDBR-EDR FCC_BT(Part15.247)TestData 1.DutyCycle ConditionAntennaRateFrequency(MHz)Dutycycle(%)Duty_factor NVNTANT11-DH12402.0030.165.21 NVNTANT11-DH12441.0030.165.21 NVNTANT11-DH12480.0030.165.21 NVNTANT12-DH12402.0031.754.98 NVNTANT12-DH12441.0032.264.91 NVNTANT12-DH12480.0030.165.21 NVNTANT13-DH12402.0030.165.21 NVNTANT13-DH12441.0031.754.98 NVNTANT13-DH12480.0032.264.91 Duty_Cycle_NVNT_ANT1_1-DH1_2402 Duty_Cycle_NVNT_ANT1_1-DH1_2441 Page3of59 Duty_Cycle_NVNT_ANT1_1-DH1_2480 Duty_Cycle_NVNT_ANT1_2-DH1_2402 Page4of59 Duty_Cycle_NVNT_ANT1_2-DH1_2441 Duty_Cycle_NVNT_ANT1_2-DH1_2480 Page5of59 Duty_Cycle_NVNT_ANT1_3-DH1_2402 Duty_Cycle_NVNT_ANT1_3-DH1_2441 Page6of59 Duty_Cycle_NVNT_ANT1_3-DH1_2480 Page7of59 2.-20dBBandwidth ConditionAntennaModulationFrequency(MHz)-20dBBW(MHz)iflargerthanCFS NVNTANT11-DH12402.001.033Yes NVNTANT11-DH12441.001.040Yes NVNTANT11-DH12480.001.034Yes NVNTANT12-DH12402.001.301Yes NVNTANT12-DH12441.001.290Yes NVNTANT12-DH12480.001.285Yes NVNTANT13-DH12402.001.268Yes NVNTANT13-DH12441.001.267Yes NVNTANT13-DH12480.001.266Yes -20dB_Bandwidth_NVNT_ANT1_1-DH1_2402_00 -20dB_Bandwidth_NVNT_ANT1_1-DH1_2441_00 Page8of59 -20dB_Bandwidth_NVNT_ANT1_1-DH1_2480_00 -20dB_Bandwidth_NVNT_ANT1_2-DH1_2402_00 -20dB_Bandwidth_NVNT_ANT1_2-DH1_2441_00 Page9of59 -20dB_Bandwidth_NVNT_ANT1_2-DH1_2480_00 -20dB_Bandwidth_NVNT_ANT1_3-DH1_2402_00 Page10of59 -20dB_Bandwidth_NVNT_ANT1_3-DH1_2441_00 -20dB_Bandwidth_NVNT_ANT1_3-DH1_2480_00 Page11of59 Page12of59 3.99%OccupiedBandwidth ConditionAntennaModulationFrequency(MHz)99%%BW(MHz) NVNTANT11-DH12402.000.936 NVNTANT11-DH12441.000.965 NVNTANT11-DH12480.000.972 NVNTANT12-DH12402.001.217 NVNTANT12-DH12441.001.220 NVNTANT12-DH12480.001.216 NVNTANT13-DH12402.001.193 NVNTANT13-DH12441.001.197 NVNTANT13-DH12480.001.197 99%_Occupied_Bandwidth_NVNT_ANT1_1-DH1_2402_00 99%_Occupied_Bandwidth_NVNT_ANT1_1-DH1_2441_00 Page13of59 99%_Occupied_Bandwidth_NVNT_ANT1_1-DH1_2480_00 99%_Occupied_Bandwidth_NVNT_ANT1_2-DH1_2402_00 99%_Occupied_Bandwidth_NVNT_ANT1_2-DH1_2441_00 Page14of59 99%_Occupied_Bandwidth_NVNT_ANT1_2-DH1_2480_00 99%_Occupied_Bandwidth_NVNT_ANT1_3-DH1_2402_00 Page15of59 99%_Occupied_Bandwidth_NVNT_ANT1_3-DH1_2441_00 99%_Occupied_Bandwidth_NVNT_ANT1_3-DH1_2480_00 Page16of59 Page17of59 4.PeakOutputPower ConditionAntennaModulation Frequency (MHz) Max.Conducted Power(dBm) Max.Conducted Power(mW) Limit(mW)Result NVNTANT11-DH12402.000.261.06125Pass NVNTANT11-DH12441.00-0.011.00125Pass NVNTANT11-DH12480.00-0.140.97125Pass NVNTANT12-DH12402.001.021.27125Pass NVNTANT12-DH12441.000.781.20125Pass NVNTANT12-DH12480.000.621.15125Pass NVNTANT13-DH12402.001.521.42125Pass NVNTANT13-DH12441.001.271.34125Pass NVNTANT13-DH12480.001.131.30125Pass Peak_Output_Power_NVNT_ANT1_1-DH1_2402_00 Peak_Output_Power_NVNT_ANT1_1-DH1_2441_00 Page18of59 Peak_Output_Power_NVNT_ANT1_1-DH1_2480_00 Peak_Output_Power_NVNT_ANT1_2-DH1_2402_00 Peak_Output_Power_NVNT_ANT1_2-DH1_2441_00 Page19of59 Peak_Output_Power_NVNT_ANT1_2-DH1_2480_00 Peak_Output_Power_NVNT_ANT1_3-DH1_2402_00 Page20of59 Peak_Output_Power_NVNT_ANT1_3-DH1_2441_00 Peak_Output_Power_NVNT_ANT1_3-DH1_2480_00 Page21of59 Page22of59 5.SpuriousEmissions ConditionAntennaModulationTXModeRef_level(dBm) Spurious MAX.Value(dBm) LimitResult NVNTANT11-DH12402.000.018-42.878-19.982Pass NVNTANT11-DH12441.00-0.324-37.045-20.324Pass NVNTANT11-DH12480.00-0.499-44.043-20.499Pass NVNTANT12-DH12402.00-0.022-43.714-20.022Pass NVNTANT12-DH12441.00-0.306-46.380-20.306Pass NVNTANT12-DH12480.00-0.547-48.664-20.547Pass NVNTANT13-DH12402.000.013-46.208-19.987Pass NVNTANT13-DH12441.00-0.308-44.536-20.308Pass NVNTANT13-DH12480.00-0.475-46.952-20.475Pass 1_Reference_Level_NVNT_ANT1_1-DH1_2402_00 2_Spurious_Emissions_NVNT_ANT1_1-DH1_2402_00 Page23of59 1_Reference_Level_NVNT_ANT1_1-DH1_2441_00 2_Spurious_Emissions_NVNT_ANT1_1-DH1_2441_00 1_Reference_Level_NVNT_ANT1_1-DH1_2480_00 Page24of59 2_Spurious_Emissions_NVNT_ANT1_1-DH1_2480_00 1_Reference_Level_NVNT_ANT1_2-DH1_2402_00 Page25of59 2_Spurious_Emissions_NVNT_ANT1_2-DH1_2402_00 1_Reference_Level_NVNT_ANT1_2-DH1_2441_00 Page26of59 2_Spurious_Emissions_NVNT_ANT1_2-DH1_2441_00 1_Reference_Level_NVNT_ANT1_2-DH1_2480_00 Page27of59 2_Spurious_Emissions_NVNT_ANT1_2-DH1_2480_00 1_Reference_Level_NVNT_ANT1_3-DH1_2402_00 Page28of59 2_Spurious_Emissions_NVNT_ANT1_3-DH1_2402_00 1_Reference_Level_NVNT_ANT1_3-DH1_2441_00 Page29of59 2_Spurious_Emissions_NVNT_ANT1_3-DH1_2441_00 1_Reference_Level_NVNT_…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 37 Hotline:400-8868-419Fax:86-755-27790922http://www.ncttesting.cn FCCTESTREPORT FCCID:2BSO8-YMJ-A7 Product: MassageChair ModelName: YMJ-A7,YMJ-A8,YMJ-A9,YMJ-A10, YMJ-A17,YMJ-A18,YMJ-19,YMJ-A20, YMJ-A27,YMJ-A28,YMJ-A29,YMJ-A30 Brand: N/A ReportNo.:NCT25047653E Preparedfor FuanYinmeijiaTradingCo.,Ltd. No.668XueyuanRoad,FuanCity,FujianProvince,China. Preparedby ShenzhenNCTTestingTechnologyCo.,Ltd. A101&2FB2,Fuqiao6thArea,XintianCommunity,FuhaiStreet,BaoanDistrict, Shenzhen,People’sRepublicofChina TEL:400-8868-419 FAX:86-755-27790922 ReportNo.:NCT25047653E Page 2 of 37 Hotline:400-8868-419Fax:86-755-27790922http://www.ncttesting.cn 1TESTRESULTCERTIFICATION Applicant’sname:FuanYinmeijiaTradingCo.,Ltd. Address: No.668XueyuanRoad,FuanCity,FujianProvince,China. Manufacture'sname:FuanYinmeijiaTradingCo.,Ltd. Address: No.668XueyuanRoad,FuanCity,FujianProvince,China. Productname:MassageChair Modelname:YMJ-A7 Additionalmodel: YMJ-A8,YMJ-A9,YMJ-A10,YMJ-A17,YMJ-A18,YMJ-19,YMJ-A20, YMJ-A27,YMJ-A28,YMJ-A29,YMJ-A30 Standards:FCCCFR47Part15Section15.247 Testprocedure:ANSIC63.10:2020 TestDate:Oct.21,2025toOct.31,2025 DateofIssue:Oct.31,2025 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyNCT,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicable onlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofNCT,this documentmaybealteredorrevisedbyNCT,personalonly,andshallbenotedintherevision ofthedocument. TestEngineer: KevenWu/Engineer TechnicalManager: HenryWang/Manager ReportNo.:NCT25047653E Page 3 of 37 Hotline:400-8868-419Fax:86-755-27790922http://www.ncttesting.cn Contents Page 1TESTRESULTCERTIFICATION...............................................................................................................................2 2TESTSUMMARY..........................................................................................................................................................5 3TESTFACILITY.............................................................................................................................................................6 4GENERALINFORMATION..........................................................................................................................................7 4.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................7 4.2CHANNELLIST.....................................................................................................................................................8 4.3TESTSETUPCONFIGURATION............................................................................................................................9 4.4TESTCONFIGURATION.........................................................................................................................................9 5EQUIPMENTDURINGTEST....................................................................................................................................10 5.1EQUIPMENTSLIST.............................................................................................................................................10 5.2MEASUREMENTUNCERTAINTY.........................................................................................................................12 5.3DESCRIPTIONOFSUPPORTUNITS...................................................................................................................12 6CONDUCTEDEMISSION..........................................................................................................................................13 6.1E.U.T.OPERATION............................................................................................................................................13 6.2EUTSETUP.......................................................................................................................................................13 6.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).................................................................................14 6.4MEASUREMENTPROCEDURE:...........................................................................................................................14 6.5CONDUCTEDEMISSIONLIMIT...........................................................................................................................14 6.6MEASUREMENTDESCRIPTION..........................................................................................................................14 6.7CONDUCTEDEMISSIONTESTRESULT.............................................................................................................14 7RADIATEDSPURIOUSEMISSIONS......................................................................................................................17 7.1EUTOPERATION...............................................................................................................................................17 7.2TESTSETUP......................................................................................................................................................18 7.3SPECTRUMANALYZERSETUP..........................................................................................................................19 7.4TESTPROCEDURE.............................................................................................................................................20 7.5SUMMARYOFTESTRESULTS...........................................................................................................................21 8MAXIMUMPEAKOUTPUTPOWERTEST............................................................................................................30 8.1TESTSTANDARDANDLIMIT..........................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BSO8-YMJ-A7TestPhoto

Contact Information

Applicant

Wenbin Xue(Manager)
[email protected]Fax: N/A

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.42 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.