Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Shantou Huihengqi Electronic Technology Co., Ltd. Address: 501, 5/F, Block C, 301, 3/F, Block A, 14A Industrial Zone, Longhu District, 515000 Shantou, Guangdong, PEOPLE'S REPUBLIC OF CHINA Tel: +86-754-8889 3348 Email: [email protected] Statement of Differences To: TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch Our company is applying for certification for the electric breast pump product models, each model can be differentiated by the suffix "-x" to indicate different colors (x = blank, 1 to 12) Models: 598-x, 518-x (-x=blank, -1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -12, indicates different colour) FCC ID: 2BSODWBP518 Difference Explanation The two series models 598-x, 518-x are identical except the appearance. All models used same Bluetooth module. The same series models only different in their exterior color appearance. Their electrical structure, key components, circuit design, and Bluetooth module are completely identical. We hereby confirm that the content of this statement is true and accurate, and we assume full responsibility for any consequences arising from misrepresentation or omission. Declared by Company Name: Shantou Huihengqi Electronic Technology Co., Ltd. Date: December 13, 2025 Contact name: Pei Li E-mail: [email protected] Tel: +86-754-8889 3348
Report Number: 64.790.26.80037.01-RF Page 1 of 1 TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F, Communication Building,163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China TEL: +86 20 3832 0668 FAX: +86 20 3832 0478 RF exposure Estimation for 598-x, 518-x 1. Introduction 598-x, 518-x (-x=blank, -1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -12, indicates different colour) are electric breast pump, which contain Bluetooth function inside. FCC ID: 2BSODWBP518 2. Limit and Guidelines on Exposure to Electromagnetic Fields According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 Mobile Portable RF Exposure v06, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 3. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Tune up power = 1.995mW (3dBm) Distance = 5 mm f = 2.480 GHz [1.995/5] * SQRT(2.480) =0.63 0.63 ≤ 3.0 Therefore, excluded from SAR testing. TUV SUD China, Guangzhou Branch Reviewed by: Prepared By: Mike Zhuo / Project Reviewer Kevin Ouyang / Project Handler Date: 2025-12-22 Date: 2025-12-22
蓝牙天线规格 Specification for Bluetooth antennas 版权所有 不得复制 All rights reserved Shall not be copied 1 :Antenna Description Antenna Type PCB Antenna product model CRM528-1-PCB Antenna peak gain 0.5dBi Frequency range 2.402GHz~2.480GHz Connect type Direct Connect Manufacturer Crown Rich Technology Holding Ltd Address Room 4-F3, Building 1, Financial Services Technology Innovation Base, No. 8, Kefa Road, Science and Technology Park Community, Yuehai Sub-district, Nanshan District, Shenzhen City 2 :Antenna picture on the PCB borad 3 :Antenna radiation of 3D polar Solution frequency at 2.44G 3 :Antenne radiation pattern
Report Number: 64.790.26.80037.01 TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F,Communication Building,163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China TEL: +86 20 3832 0668 FAX: +86 20 3832 0478 Page 1 of 51 FCC - TEST REPORT Report Number : 64.790.26.80037.01 Date of Issue: 2025-12-24 Model/HVIN : 598-x, 518-x (-x=blank, -1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -12, indicates different colour) Product Type : Electric Breast Pump Applicant : Shantou Huihengqi Electronic Technology Co., Ltd. Address : 501, 5/F, Block C, 301, 3/F, Block A, 14A Industrial Zone, Longhu District, 515000 Shantou, Guangdong, PEOPLE'S REPUBLIC OF CHINA Manufacturer : Shantou Huihengqi Electronic Technology Co., Ltd. Address : 501, 5/F, Block C, 301, 3/F, Block A, 14A Industrial Zone, Longhu District, 515000 Shantou, Guangdong, PEOPLE'S REPUBLIC OF CHINA Factory : Shantou Huihengqi Electronic Technology Co., Ltd. Address : 501, 5/F, Block C, 301, 3/F, Block A, 14A Industrial Zone, Longhu District, 515000 Shantou, Guangdong, PEOPLE'S REPUBLIC OF CHINA Test Result : ◼ Positive Negative Total pages including Appendices : 51 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question. It does not imply a general statement regarding the quality of products from regular production. For further details please see Testing, Certification, Validation and Verification Regulations, chapter A- 3.3. Report Number: 64.790.26.80037.01 TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F,Communication Building,163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China TEL: +86 20 3832 0668 FAX: +86 20 3832 0478 Page 2 of 51 1 Table of Contents 1 Table of Contents ...................................................................................................................................................2 2 Details about the Test Laboratory ..........................................................................................................................3 3 Description of the Equipment Under Test ..............................................................................................................4 4 Summary of Test Standards ..................................................................................................................................5 5 Summary of Test Results .......................................................................................................................................6 6 General Remarks ...................................................................................................................................................7 7 Test Setups ............................................................................................................................................................8 7.1 Radiated test setups .......................................................................................................................................8 7.2 Conducted RF test setups ..............................................................................................................................9 7.3 AC Power Line Conducted Emission test setups ...........................................................................................9 8 Systems test configuration .................................................................................................................................. 10 9 Technical Requirement ....................................................................................................................................... 11 9.1 Conducted Emission .................................................................................................................................... 11 9.2 Conducted Output Power ............................................................................................................................ 14 9.3 6 dB Bandwidth ............................................................................................................................................ 17 9.4 Power spectral density ................................................................................................................................. 20 9.5 Spurious RF conducted emissions .............................................................................................................. 23 9.6 Band edge testing ........................................................................................................................................ 27 9.7 Spurious radiated emissions for transmitter ................................................................................................ 30 10 Test Equipment List ......................................................................................................................................... 50 11 System Measurement Uncertainty .................................................................................................................. 51 Report Number: 64.790.26.80037.01 TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F,Communication Building,163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China TEL: +86 20 3832 0668 FAX: +86 20 3832 0478 Page 3 of 51 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F & 8F East, Communication Building, No.163 Pingyun Road, Huangpu Ave. West Guangzhou 510656 P.R. China Telephone: 86 20 3815 3415 FCC Registration No.: 141693 FCC Designation Number: CN1408 Report Number: 64.790.26.80037.01 TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch 5F,Communication Building,163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China TEL: +86 20 3832 0668 FAX: +86 20 3832 0478 Page 4 of 51 3 Des…
Text truncated - open the document above for the full version.
1337 Massachusetts Avenue #158 Arlington, MA 02476 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.32 mW |