2BSPE-1HPWater Chiller

huizhoushizeyudianzishangwuyouxiangongsi
Water Chiller - FCC ID 2BSPE-1HP - huizhoushizeyudianzishangwuyouxiangongsi
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 25, 2025
Application Purpose
Original Equipment
Equipment Note
Water Chiller
Frequency Range
2412.00000000 - 2462.00000000
Company
huizhoushizeyudianzishangwuyouxiangongsi
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation and Use Manual Please read this manual carefully before using 18 A. Execute the startup and shutdown sequence according to the prescribed procedure every day. B. Record unit operating parameters at certain intervals. C. Check whether the pressure of the unit is within the normal range through the pressure gauge display on the unit. D. Check whether the appearance of the unit is intact, the surrounding environment is clean and dry, and the ventilation is good, and the components (water pump, compressor, etc.) operate normally. E. Attention should be paid to any shutdown failure and the reasons should be analyzed. Before notifying the company for processing, analysis in conjunction with the troubleshooting help of this manual may help resolve the problem. Scheduled maintenance Caution: In order to prevent casualties due to contact with moving parts or contact with live parts, disconnect the main power supply and hang a clear no-closing sign at the switch position before maintenance inspection! Periodic maintenance includes weekly, monthly, quarterly, and annual maintenance. According to the following contents, customers develop a scientific regular maintenance plan and carefully implement it, which can play a very important role in preventing problems. 1 Introduction Dear users: Thank you very much for choosing our energy saving products!We will be happy to serve you! Please read the instructions carefully before installing and using the product. Otherwise, the equipment may be damaged or the operator may be injured or injured. Installation and maintenance work. It must be operated by professional and technical personnel who have rich experience in installation and maintenance of this model. In case of property damage or casualties caused by violation of this requirement, our company. Will not accept any liability. In order for you to enjoy the service within the warranty period, please strictly follow the requirements of this manual when using the heat pump unit: when reading this manual, if you need technical advice, please contact the company or local agent. 17 6.1 Routine Maintenance This section describes the preventive maintenance and breakdown repair of the unit. Correct maintenance and timely maintenance are conducive to ensuring that the unit is always in the best condition, maintaining the highest efficiency, and extending the life of the unit. Maintenance refers to the preventive maintenance of the unit, and repair refers to the repair of the faulty unit. You are advised to formulate equipment maintenance regulations according to the requirements in this section, and appoint qualified equipment management engineers and dedicated unit operators to perform routine and periodic maintenance. Caution: Unit repairs resulting from incorrect maintenance during the unit warranty period will result in additional costs for the user. The most basic work of unit maintenance and maintenance is to record the operating parameters of the unit at an appropriate time interval every day (such as one hour) and fill in the unit operating parameter table. The true and complete operation parameter record helps to analyze the possible development trend of the unit operation, and helps to timely discover and predict the problems that may occur in the unit, so as to prevent them from happening. For example, through the analysis and comparison of the operation records of one month, it may be found that the difference between the coil temperature of the unit and the ambient temperature has a trend of increasing. This trend indicates that the fins of the unit have scale or dirty blockage, or the ventilation is poor, and personnel should be arranged to check and maintain in time. Note: It is very useful to keep a record of the parameters of the normal operation of the unit during commissioning. This record can be used as a benchmark to compare with subsequent operation records to find the trend of the problem. 6.2 Maintenance 2 Notice A. When installing the air source pool unit, please check whether the specifications and capacity of the power supply meet the requirements of the pool machine according to the nameplate of the unit. B. The power supply of the air source pool unit must be connected with a leakage protection switch, and the leakage protection switch capacity should be greater than the maximum electricity flow of the air source heat pump unit. C. The air source pool unit must have good grounding (grounding resistance ≤0.1Ω) and reliable lightning protection. D. The air source pool unit must be installed in an outdoor ventilated, easy to install and maintain the site. E. The air source pool unit will produce condensate water during operation, drainage pipes and exhaust valves should be designed and installed to ensure that the condensate is discharged in time. F. The air source pool unit must be installed before the water inlet filter, and please remove the air in the tube before use. G. The air source pool machine product is a pressure unit with strong air tightness, which needs to be careful in the process of transportation and hoisting, and can not roll, collide, shake and stack. 16 6. Maintenance and maintenance 3 H. For your safety, do not modify the air source heat pump unit. I. It is strictly prohibited to insert any tools or hard objects into the air source pool unit, so as not to damage the unit or cause accidents due to collision with the wind blade or evaporator. J. Do not use the air source pool unit in the state of removing the barrier or sheet metal and other protective devices, so as to avoid accidents or unit failures. K. When the unit is flooded, please contact the factory or local dealers immediately, must be checked by technicians before reuse the pool unit. L. Personnel without professional qualifications shall not adjust the switches, valves, controllers and other components inside the unit. 1. Product introduction 1.1 Unit Features A. Safe and reliable: the air so…

Text truncated - open the document above for the full version.

Attestation Statements

Huizhoushizeyudianzishangwuyouxiangongsi Covered Equipment Certification Attestation Letter 11/19/2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BSPE-1HP Huizhoushizeyudianzishangwuyouxiangongsi (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Huizhoushizeyudianzishangwuyouxiangongsi (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Huizhoushizeyudianzishangwuyouxiangongsi (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: zhou fei Title: Manager Company Name: Huizhoushizeyudianzishangwuyouxiangongsi Date: 11/19/2025

Attestation Statements

Huizhoushizeyudianzishangwuyouxiangongsi U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: November 19, 2025 Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BSPE-1HP Huizhoushizeyudianzishangwuyouxiangongsi(“the applicant”) certifies that, as of the date of the filing of the application, CLF Import and Export Limited (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. CLF Import and Export Limited ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: CLF Import and Export Limited FRN: 0033489683 Address: 1312 17th Street #692, Denver, CO 80202, United States Signature: Contact Person: David Chen Tel: +1 949 254 2565 Email: [email protected] Applicant Company Name: Huizhoushizeyudianzishangwuyouxiangongsi FRN: 0037589611 Address: jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo 2402haozhiyi huizhoushi guangdongsheng, China Signature: Contact Person: zhou fei Tel: +86-18823709181 Email: [email protected]

Cover Letter(s)

DATE: November 19, 2025 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BSPE-1HP Product Name: Water Chiller Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...)  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name: zhou fei Title: Manager Company: Huizhoushizeyudianzishangwuyouxiangongsi

Cover Letter(s)

Date: November 19, 2025 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, <Signature> Name: zhou fei Title: Manager Company: Huizhoushizeyudianzishangwuyouxiangongsi

Cover Letter(s)

DATE: November 19, 2025 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen CCUT Quality Technology Co., Ltd. (1F, Building 35, Changxing Technology Indstrl Park Changzhen Community, Yutang Street,Shenzhen,China) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Huizhoushizeyudianzishangwuyouxiangongsi (jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo2402haozhiyi huizhoushi guangdongsheng, China). <Signature> Name: zhou fei Title: Manager Company: Huizhoushizeyudianzishangwuyouxiangongsi

Cover Letter(s)

Huizhoushizeyudianzishangwuyouxiangongsi Model Difference Statement FCC ID: 2BSPE-1HP DATE: November 19, 2025 Dear Sir/Madam, Added models 0.5HP, 0.3HP basis of the original product 1HP.The color of appearance and model name of series models listed are different from the main model, but the circuit and the electronic construction are the same, declared by the manufacturer. Sincerely, Name: zhou fei Company name: Huizhoushizeyudianzishangwuyouxiangongsi Address: jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo2402haozhiyi huizhoushi guangdongsheng, China

External Photos

Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report Annex A. EUT External Photos Model: 1HP EUT View 1 EUT View 2 Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT View 3 EUT View 4 Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT View 5 EUT View 6

ID Label/Location Info

Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report Annex D. Label and Inf ormation FCC Label Sample FCC Label Specifications Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Where the EUT is constructed in two or more sections connected by wires and marketed together, the above statement is required to be affixed only to the main control unit. When the EUT is so small or for such use that it is not practicable to place the statement on it, the above information shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. FCC Label Location

Internal Photos

Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report Annex B. EUT Internal Photos Model: 1HP EUT Internal View 1 EUT Internal View 2 Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT Internal View 3 EUT Internal View 4 PCB ANT Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT Internal View 5 EUT Internal View 6 Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT Internal View 7 EUT Internal View 8 Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report EUT Internal View 9

RF Exposure Info

FCC ID: 2BSPE-1HP RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation WiFi mode Mode Output power to antenna (dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 12.93 12(±1) 13 19.95 0.004 1.0 PASS Remark: antenna gain= 0dBi

Test Report

Page 1 of 3 1. General Inf ormation 1.1 Antenna Information Manufacturer: huizhoushizeyudianzishangwuyouxiangongsi Address of Manufacturer: jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo2402haozhiyi huizhoushi guangdongsheng, China Product Name: 2.4GHz Antenna Model Name: 1HP Frequency Range: 2412MHz - 2462MHz Type of Antenna: PCB Antenna Antenna Gain: 0dBi (Max.) Impedance: 50 ohm Antenna View: Length * Width (18mm * 7.2mm) Page 2 of 3 2. Antenna Specification inf ormation 2.1 Gain Frequency Peak Gain (dBi) Polarity 2412MHz 0 Horizontal 2412MHz -0.47 Vertical 2437MHz -1.67 Horizontal 2437MHz -1.83 Vertical 2462MHz -1.98 Horizontal 2462MHz -2.09 Vertical Page 3 of 3 2.2 Radiation Pattern View

Test Report

Report No: SSP25100107-1E FCC Test Report Page 1 of 50 FCC TEST REPORT FCC ID: 2BSPE-1HP Report No. : SSP25100107-1E Applicant : huizhoushizeyudianzishangwuyouxiangongsi Product Name : Water Chiller Model Name : 1HP Test Standard : FCC Part 15.247 Date of Issue : 2025-10-31 Shenzhen CCUT Quality Technology Co., Ltd. 1F, Building 35, Changxing Technology Industrial Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China; (Tel.:+86-755-23406590 website: www.ccuttest.com) This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd. Report No: SSP25100107-1E FCC Test Report Page 2 of 50 Test Report Basic Information Applicant..................................: huizhoushizeyudianzishangwuyouxiangongsi Address of Applicant...............: jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo2402haozhiyi huizhoushi guangdongsheng, China Manufacturer..........................: huizhoushizeyudianzishangwuyouxiangongsi Address of Manufacturer........: jiangbei16haoxiaoqushuangzixingguojishangwudashaAzuo2402haozhiyi huizhoushi guangdongsheng, China Product Name.........................: Water Chiller Brand Name.............................: - Main Model..............................: 1HP Series Models..........................: 0.5HP, 0.3HP Test Standard..........................: FCC Part 15 Subpart C KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.4-2014 ANSI C63.10-2020/Cor 1-2023 Date of Test .............................: 2025-10-24 to 2025-10-29 Test Result...............................: PASS Tested By ................................: (Walker Wu) Reviewed By............................: (Lorzix Luo) Authorized Signatory............: (Lahm Peng) Note : This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen CCUT Quality Technology Co., Ltd.. All test data presented in this test report is only applicable to presented test sample. Report No: SSP25100107-1E FCC Test Report Page 3 of 50 CONTENTS 1. General Information ....................................................................................................................................................5 1.1 Product Information .............................................................................................................................................5 1.2 Test Setup Information..........................................................................................................................................6 1.3 Compliance Standards ...........................................................................................................................................7 1.4 Test Facilities ........................................................................................................................................................7 1.5 List of Measurement Instruments ..........................................................................................................................8 1.6 Measurement Uncertainty .....................................................................................................................................9 2. Summary of Test Results ........................................................................................................................................... 10 3. Antenna Requirement ............................................................................................................................................... 11 3.1 Standard and Limit.............................................................................................................................................. 11 3.2 Test Result .......................................................................................................................................................... 11 4. Conducted Emissions ................................................................................................................................................ 12 4.1 Standard and Limit.............................................................................................................................................. 12 4.2 Test Procedure.................................................................................................................................................... 12 4.3 Test Data and Results .......................................................................................................................................... 13 5. Radiated Emissions ................................................................................................................................................... 16 5.1 Standard and Limit.............................................................................................................................................. 16 5.2 Test Procedure.................................................................................................................................................... 16 5.3 Test Data and Results .......................................................................................................................................... 18 6. Band-edge Emissions(Radiated) ............................................................................................................................... 22 6.1 Standard and Limit.............................................................................................................................................. 22 6.2 Test Procedure.................................................................................................................................................... 22 6.3 Test Data and Results ..........................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report Annex C. Test Photos Conducted Emission Test View Radiated Emission Test View Below 1GHz Radiated Emission Test View Above 1GHz Report No: SSP25100107-1E FCC ID: 2BSPE-1HP Annex of Test Report

Contact Information

Applicant

zhou fei
[email protected]Fax: +86-18823709181

Test Firm

Shenzhen CCUT Quality Technology Co., Ltd.Lahm Peng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz19.64 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This device supports 20 and 40MHz bandwidth operation.