Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RVLevelingSystem Installation&OperationManual SECTION1.Pre-InstallationRequirements 1.Selectamountingpositionwithin10ft(3m)ofthedriverâsseat,freefromlargemetallic obstructionssuchasrefrigerators,microwaves,oraluminumcabinetry.Anexteriorstorage compartmentispreferredforoptimalRFperformance. 2.TemporarilypowertheunitwithbatteriesandverifyBluetoothÂŽsignalstrengthatthedesired locationbeforepermanentmounting. SECTION2.MechanicalInstallation 1.Simultaneouslydepressthetwosidereleasetabsandliftoffthefrontcover. 2.Usingthesupplied#6Ă1â˛â˛screws,securetherearflangetothewallstructure(onescrewper hole).Theunitshouldbeapproximatelylevel;aprecisionlevelisnotrequiredbecausethesoftware willlaterzero-outanysmalloffset. 3.InserttwoAAalkalinebatteries,observingthepolaritydiagrammoldedinthebatterytray. Reinstallthecoveruntilanaudibleclickconfirmsfullengagement. --SECTION3.MobileApplication&Pairing 1.DownloadâRVLevelingSystemâfromtheAppleAppStoreorGooglePlay.Launchtheappand grantBluetoothpermissionswhenprompted. 2.TapâConnectâinsidetheappandselecttheserialnumberthatmatchesthelabelinthebattery compartment. GooglePlayAppStore SECTION4.DimensionalCalibration SettingsâTrailerSettings: a.TrailerWidth:Outside-to-outsidetiredistance(inches). b.TrailerLength: Trailers:centerofrearwheeltojackfoot. Motorhomes:centerofrearwheeltocenteroffrontwheel. PresstheblueSAVEbutton;awaittheâTrailerSettingsUpdatedâconfirmation. SECTION5.OrientationCalibration SettingsâDeviceSettingsâUnitInstallationLocation:choosethecardinaldirectionthelogofaces (Driver,Passenger,Front,orRear).IncorrectentrywillinverttheRoll/Pitchindications. SECTION6.Zero-LevelReferenceCalibration 1.PositiontheRVonlevelconcrete.Verifylevelwithamachinistâsorbullseyelevelboth longitudinallyandlaterally;deployslide-outs. 2.AdjustrampsorjacksuntilthecoachiswithinÂą0.25â˛â˛oftruelevel. 3.Intheapp,DeviceSettingsâSetAsLevelâConfirmtwice.RollandPitchshalldisplay0.00â˛â˛. WARNING:Recalibratingonunlevelgroundwillpermanentlyshiftthezero referenceandinvalidateallsubsequentreadings. SECTION7.RoutineLevelingWorkflow a.Side-to-Side(Roll):Placerampsunderthelowtireindicatedbythered/yellowgauge;slowly driveforwarduntilthedisplayreadsâ¤1.00â˛â˛(greenzone).Chockwheels. b.Front-to-Rear(Pitch):Raiseorlowerthetonguejack(orfronthydraulicjacks)untilthePitch screenreadsâ¤1.00â˛â˛. c.Whenbothaxesareâ¤1.00â˛â˛,thecoachisdeemedcamp-ready. SECTION8.TroubleshootingMatrix SymptomCorrectiveAction Devicenotdiscovered1.Replacebatteries 2.Android:enableLocationServices 3.Removebatteries10stoforcedisconnect ReadingsreversedVerifyâUnitInstallationLocationâmatches logo-facingdirection PersistentoffsetRe-enterdimensionsandrepeatzero-level calibrationonlevelground SECTION9.Maintenance&Storage Replacebatteriesannuallyorwhenthelow-batteryiconappears.Removebatteriesiftheunitwillbe stored>90days.Cleanthehousingwithalightlydampenedmicrofibercloth;donotusesolventsor abrasivepads. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ď -Reorient or relocate the receiving antenna. ď -Increase the separation between the equipment and receiver. ď -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ď -Consult the dealer or an experienced radio/TV technician for help. *RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
AttestationStatements Date:2025-11-19 TO:FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046,USA RE:AttestationStatementsPart2.911(d)(7)requestfor(FCCID:2BSQY-RVLS-25-A) JiuJiangKaiGaodianzishangwuCo.,Ltd.theundersigned,herebyauthorizeHOPEK CORPORATIONINC - toactasourdesignatedU.S.agentforserviceofprocess,JiuJiang KaiGaodianzishangwuCo.,Ltd.acceptstomaintainanagentfornolessthanone yearafterthegranteehasterminatedallmarketingandimportationortheconclusion ofanyCommission-relatedproceedinginvolvingtheequipment. HOPEKCORPORATIONINCacceptstheresponsibilitytoactasdesignatedU.S.agentfor serviceofprocess. ApplicantInformationďź Companyname:JiuJiangKaiGaodianzishangwuCo.,Ltd. ContactName:YinChao Address:9-E435,cross-bordere-commerceindustrialpark,ShunyiRoadNo.9,Jingkai district,Jiujiangcity,Jiangxiprovince TelephoneNo:18079282016 Email:[email protected] FRN:0037612355 Signature: YinChao U.S.AgentInformation: CompanyName:HOPEKCORPORATIONINC Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates FRN:0034562900 ContactName:PeterDavis TelephoneNo:561-235-6113 Email:[email protected] Signature: PeterDavis
Rev 1/26/2023 Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-11-19 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BSQY-RVLS-25-A Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. certifies that the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) ( Yin Chao) Rev 1/26/2023 Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-11-19 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BSQY-RVLS-25-A Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing âcoveredâ equipment. Sincerely, (Applicant signature) ( Yin Chao)
V . S .W . R < 1.4 Polarization Type V ertical & Horizontal Frequenc Range2400 ~ 2500GHz Input Impendence(ohm)50 Efficiency (dB) 6 0.2 % 6 0.2 % Maximum Power (dBm) 1.6 8(XZ-plane) Gain (dBi) 1.68 (Peak Gain XY-plane) Peak EIRP(dBm)1.2 Tot. Rad. Pwr. (dBm)-1.2 (Input pwr â loss pwr) Antenna Specification Quick Re ference Date Antenna modul e on the system board Ant. Port Input Pwr. (dBm)0 (Typ. BT class 2 output power) Directivity (dBi)1 (all dire ction antenna) Minimum Power (dBm ) -3.83(XZ-plane) Avg. Power (dBm)-0.48(XY-plane) All the technical data and information contained herein are subject to change without prio r notice Antenna Layout & module on the system board Antenna Gain Gain Table Unit in dBi @2.44GHzXY-planeXZ-planeYZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 1.68 1.35 -0.48 -3.83 1.11 -2.99 Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Ret urn Loss The Environment of Antenna Radiation Pattern 3D radiation pattern diagram XY -planeXZ-planeYZ-plane
Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: November 19, 2025 Subject; Request for Confidentiality FCC ID: 2BSQY-RVLS-25-A To Whom It May Concern, Pursuant to the provisions of the Commissionâs rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yin Chao Title: CEO
Effective Date: April 2, 2020 QSF 7.6.4-8 â Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Dateďź11/19/2025 Product Model Number: Rvls-25-A FCC IDďź2BSQY-RVLS-25-A To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: ⢠Testing ⢠Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Yin Chao Contact Listed on FCC Wesbite Title: CEO Email: [email protected] On behalf of: Jiu Jiang Kai Gao dian zi shang wu Co., Ltd.
Page 1 of 3 Report No.: FCS202510147 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: Rvls-25-A Photo 1 Photo 2 Page 2 of 3 Report No.: FCS202510147 Photo 3 Photo 4 Page 3 of 3 Report No.: FCS202510147 Photo 5 Photo 6
Label Size: 20mm * 45mm The label is silk-screen on the sample RV Leveling System Model: Rvls-25-A FCC ID:2BSQY-RVLS-25-A This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 1 of 2 Report No.: FCS202510147 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: Rvls-25-A Photo 1 Photo 2 BLE Antenna Page 2 of 2 Report No.: FCS202510147 Photo 3
FCC Test Report Report No: FCS202510147H01 Issued for Applicant: Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address: 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Product Name: RV Leveling System Brand Name: N/A Model Name: Rvls-25-A Series Model: N/A FCC ID: 2BSQY-RVLS-25-A Test Standard: FCC 47CFR §2.1091 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicantâs Name .................... : Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address .................................. : 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Manufacture's Name ............... : Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address .................................. : 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Product Description Product Name ......................... : RV Leveling System Brand Name ........................... : N/A Model Name ........................... : Rvls-25-A Series Model ........................... : N/A Test Standards ........................ : FCC 47CFR §2.1091 447498 D01 Interim General RF Exposure Guidance v06 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document. Date of Test ............................... : Date (s) of performance of tests : Oct. 17, 2025 ~ Oct. 29, 2025 Date of Issue .............................. : Oct. 29, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TABLE OF CONTENTS 1. GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST FACTORY 6 2. FCC 47CFR §2.1091 REQUIREMENT 7 2.1 TEST STANDARDS 7 2.2 LIMIT 7 2.3 TEST RESULT 9 Page 4 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Contents 00 Oct. 29, 2025 Initial Issue Page 5 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name RV Leveling System Brand N/A Model Number Rvls-25-A Series Model(s) N/A Model Difference N/A Product Description The EUT is RV Leveling System Operation Frequency: 2402~2480 MHz Modulation Type: BLE: GFSK Antenna gain: 1.68 dBi Antenna Designation: PCB antenna Power Supply DC 3V Hardware version number V1.0 Software version number V1.0 Page 6 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.2 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation numberďź5545.01 ISED Numberďź25801 CAB ID ďźCN0097 Page 7 of 9 Report No.: FCS202510147H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commissionâs guidelines. According to §1.1310 and §2.1091 RF exposure requirement KDB447498 D01v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of âŚ
Text truncated - open the document above for the full version.
FCC Test Report Report No: FCS202510147W01 Issued for Applicant: Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address: 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Product Name: RV Leveling System Brand Name: N/A Model Name: Rvls-25-A Series Model: N/A FCC ID: 2BSQY-RVLS-25-A Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicantâs Name ................... : Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address .................................. : 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Manufacture's Name .............. : Jiu Jiang Kai Gao dian zi shang wu Co., Ltd. Address .................................. : 9-E435, cross-border e-commerce industrial park, Shunyi Road No. 9, Jingkai district, Jiujiang city, Jiangxi province Product Description Product Name ........................ : RV Leveling System Brand Name ........................... : N/A Model Name ........................... : Rvls-25-A Series Model .......................... : N/A Test Standards ....................... : FCC Part15.247 Test Procedure ....................... : ANSI C63.10-2020 KDB558074 D01 15.247 Meas Guidance v05r02 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document. Date of Test ............................... : Date (s) of performance of tests : Oct. 17, 2025 ~ Oct. 29, 2025 Date of Issue .............................. : Oct. 29, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.5 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 14 4. RADIATED EMISSION MEASUREMENT 15 4.1 RADIATED EMISSION LIMITS 15 4.2 TEST PROCEDURE 17 4.3 TEST SETUP 18 4.4 EUT OPERATING CONDITIONS 18 4.5 FIELD STRENGTH CALCULATION 19 4.6 TEST RESULTS 20 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 25 5.1 LIMIT 25 5.2 TEST PROCEDURE 25 5.3 TEST SETUP 25 5.4 EUT OPERATION CONDITIONS 25 5.5 TEST RESULTS 25 6. POWER SPECTRAL DENSITY TEST 26 6.1 LIMIT 26 6.2 TEST PROCEDURE 26 Page 4 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents 6.3 TEST SETUP 26 6.4 EUT OPERATION CONDITIONS 26 6.5 TEST RESULTS 26 7. BANDWIDTH TEST 27 7.1 LIMIT 27 7.2 TEST PROCEDURE 27 7.3 TEST SETUP 27 7.4 EUT OPERATION CONDITIONS 27 7.5 TEST RESULTS 27 8. PEAK OUTPUT POWER TEST 28 8.1 LIMIT 28 8.2 TEST PROCEDURE 28 8.3 TEST SETUP 29 8.4 EUT OPERATION CONDITIONS 29 8.5 TEST RESULTS 29 9. ANTENNA REQUIREMENT 30 9.1 STANDARD REQUIREMENT 30 9.2 EUT ANTENNA 30 APPENDIX I:TEST RESULTS 31 DUTY CYCLE 31 MAXIMUM PEAK CONDUCTED OUTPUT POWER 34 -6DB BANDWIDTH 37 OCCUPIED CHANNEL BANDWIDTH 40 MAXIMUM POWER SPECTRAL DENSITY LEVEL 43 BAND EDGE 46 CONDUCTED RF SPURIOUS EMISSION 49 Page 5 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Contents 00 Oct. 29, 2025 Initial Issue Page 6 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) âN/Aâ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 52 Report No.: FCS202510147W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lakâŚ
Text truncated - open the document above for the full version.
Page 1 of 1 Report No.: FCS202510147 DTS Setup photo Model Number: Rvls-25-A DTS radiation L DTS radiation H
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.80 mW |