  2. GUANGZHOU YOKO ELECTRON CO.,LTD/
  3. 2BSR3TC6

2BSR3TC6Mobile Data Terminal

GUANGZHOU YOKO ELECTRON CO.,LTD

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Dec 11, 2025
Application Purpose
Original Equipment
Equipment Note
Mobile Data Terminal
Frequency Range
5180.00000000 - 5240.00000000
Company
GUANGZHOU YOKO ELECTRON CO.,LTD
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 14 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 15 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 16 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 17 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 18 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 19 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 20 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 21 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 22 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 23 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 24 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 25 of 53 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 26 of 53

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA, or any agency of the Federal Government. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included but no need marked. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 755-26503290 Web: www.atc-lab.com Rev:A/4.0(2024/11/01) Page 1 of 154 TR-4-E-R027 TEST REPORT Applicant Name: GUANGZHOU YOKO ELECTRON CO.,LTD Address: 1 Room301, 7th Huanbaosan Rd., Xintang Town, Zengcheng District, Guangzhou City 511340 Report Number: 2504X28433E-RF-00D FCC ID: 2BSR3TC6 Test Standard (s) FCC PART 15.407 Sample Description Product Name: Mobile Data Terminal Model No.: TC60 (Am) Trade Mark: N/A Date Received: 2025-07-28 Report Date: 2025-10-30 Test Result: The EUT complied with the standards above. Prepared and Checked By: Approved By: Roger Ling Bob.Liao EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-RF-00D Rev:A/4.0(2024/11/01) Page 2 of 154 TR-4-E-R027 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ................................................................................................................ 4 GENERAL INFORMATION ............................................................................................................................ 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ........................................................................ 5 OBJECTIVE ................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................... 5 TEST FACILITY .............................................................................................................................................. 6 MEASUREMENT UNCERTAINTY ....................................................................................................................... 6 SYSTEM TEST CONFIGURATION ............................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION......................................................................................................... 7 EUT EXERCISE SOFTWARE AND POWER LEVEL # ............................................................................................ 7 SPECIAL ACCESSORIES ................................................................................................................................. 7 EQUIPMENT MODIFICATIONS .......................................................................................................................... 8 SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................... 8 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................. 8 SUMMARY OF TEST RESULTS ................................................................................................................. 10 TEST EQUIPMENT LIST ............................................................................................................................. 11 RF EXPOSURE ............................................................................................................................................ 12 APPLICABLE STANDARD ............................................................................................................................... 12 TEST RESULT ............................................................................................................................................. 12 ANTENNA REQUIREMENT......................................................................................................................... 13 APPLICABLE STANDARD ............................................................................................................................... 13 ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................... 13 AC CONDUCTED EMISSIONS ................................................................................................................... 14 APPLICABLE STANDARD ............................................................................................................................... 14 EUT SETUP ................................................................................................................................................ 14 EMI TEST RECEIVER SETUP ........................................................................................................................ 14 TEST PROCEDURE ...................................................................................................................................... 14 CALCULATION ............................................................................................................................................. 15 UNDESIRABLE EMISSION ..................…

Text truncated - open the document above for the full version.

Test Report

HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen Antenna Report 1. Te s t L a b o ra t o r y 1.1 Test facility GTS Rayzone 2800 Microwave Anechoic Chamber :testing frequency ranges from 600MHz to 6GHz . 1.2 Laboratory Environment Temperature Min.= 19°C, Max.=25°C Relative humidity Min.=40%,Max.=72% Shield effect 0.6-7GHz >100dB Ground resistance <0.5Ω 2. General Description of Equipment Under Test 2.1 Applicant and Product information Applicant Name SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Applicant address 606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen Product Description LT E Rugged device Model Name G601-M 2.2 General Description of Equipment 2.3 Applied Standards HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen According to the specifications of the manufacturer,it must comply with the requirements of the following standards: Test Method:ANSI/IEEE Std 149-2008 3. Test Conditions 3.1 Test Configuration The method is used to measure the antenna 3D GAIN of EUT in OTA qualified anechoic chamber. Equipment Under Test(EUT) geometry centre vertical projection at the centre of platform, the distance from EUT to measurement antenna is 1m. 3.2 Test Measurement Spherical coordinate system Figure 1 Test coordinate system Note: Theta is from 0-180degree.Phi is from EUT and record the Date, the step of rotation is 15 degree. Te s t S e t u p EUT Description Product Name RayZone2800 Model GTS-ANT D-H HW Version RayZone2800 V1.0 SW Version MaxSign 100 Antenna Type PIFA Antenna Manufacturer Shenzhen General Test System Co., Ltd Room 301-303, Building 1399, Hengnan Road, Minhang District, Shanghai Test Frequency 700MHz-6GHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen 4. Test Results 4.1 Gain and Efficiency Technical Specification Band Mode Name Frequency (MHz) Antenna Type Antenna Max Gain GSM Band Band-5 GSM 850 824-894 PIFA -5.16 dBi Band-8 GSM 900 880-960 -4.93 Band-3 DCS 1800 1710-1880 1.27 Band-2 PCS 1900 1850-1990 1.04 UMTS Band Band-1 2100 IMT 1920-2170 PIFA 0.1 dBi Band-2 1900 FDD PCS 1850-1990 1.04 Band-4 1710 FDD PCS 1710-2170 -0.19 Band-5 850 CLR 824-894 -5.16 Band-8 900 E-GSM 880-960 -4.93 LT E Band Band-1 2100 FDD IMT 1920-2170 PIFA 0.1 dBi Band-2 1900 FDD PCS 1880-1990 1.04 Band-3 1800 FDD DCS 1710-1880 1.27 Band-4 1710 FDD PCS 1710-2170 -0.19 Band-5 850 FDD CLR 824-894 -5.16 Band-7 2600 FDD IMT-E 2500-2690 -0.88 Band-12 700 FDD APT 698-803 -7.18 Band-13 700 FDD APT 703-803 -5.37 Band-14 700 FDD APT 703-803 -6.8 Band-25 2170 FDD PCS 1710-2170 1.27 Band-26 850 FDD ECLR 814-894 -5.07 Band-28 700 FDD APT 703-803 -6.8 Band-30 2170 FDD PCS 1710-2170 1.27 Band-66 2170 FDD PCS 1710-2170 0.84 Band-71 600 FDD APT 600-700 -5.81 Band-38 2600 TDD IMT-E 2570-2620 -0.77 Band-40 2300 TDD S-Band 2300-2400 -1.51 Band-41 2500 TDD BRS 2496-2690 -0.77 WiFi 802.11b/g/n 2.4GHz Wi-Fi 4 2401-2495 PIFA 0.34 dBi 802.11a/n/ac 5GHz Wi-Fi 5 4910-5895 B1: -2.18 B4: -5.67 HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen BT Bluetooth 2400-2500 PIFA 0.34 dBi GPS Gps L1 Band 1575.42 PIFA -1.28 dBi HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen 5. Equipment List Type of Equipment Manufacture Model Number Network Analyzer Key sight E5071C Switch control System GTS RayZone2800 Software GTS MaxSign 100Patten Measurement software 3D Patten Plots Main: 680MHz 770 MHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen 930 MHz 1820 MHz 1960 MHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen 2140 MHz 2360 MHz 2600 MHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen G/W/B: 1575 MHz 2450 MHz 5300 MHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen AUX: 680 MHz 770 MHz 830 MHz HXT OTA Te s t Report SHENZHEN HENGXIANGTONG ANTENNA TECNOLOGY CO., LTD. Add:606, Building E, Enterprise Aviation Technology Innovation Research and Development Industrial Park, No. 1008, Songbai Road, Sunshine Community, Xili Street, Nanshan District, Shenzhen 930 MHz 1820 MHz 1960 MHz HXT OTA Te s t Report SHENZHEN HENGXIANG…

Text truncated - open the document above for the full version.

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 1 / 32 Test Plot 1#: GSM 850 Mid Head Left Cheek DUT: Mobile Data Terminal; Type: TC60 (Am); Serial: 3ABP-1 Communication System: Generic GPRS-4 slots (0); Frequency: 836.6 MHz; Duty Cycle: 1:2 Medium parameters used: f = 836.6 MHz; σ = 0.919 S/m; ε r = 41.886; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7441; ConvF(8.4, 8.36, 8.26) @836.6 MHz; Calibrated: 2025/09/11  Sensor-Surface: 1.4mm (Mechanical Surface Detection);  Electronics: DAE4 Sn1562; Calibrated: 2024/12/31  Phantom: Twin SAM; Type: QD000P40CD; Serial: 1744  Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.237 W/kg Zoom Scan (5x5x7) /Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.641 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.235 W/kg SAR(1 g) = 0.186 W/kg; SAR(10 g) = 0.164 W/kg Smallest distance from peaks to all points 3 dB below = 14.3 mm Ratio of SAR at M2 to SAR at M1 = 92.7% Maximum value of SAR (measured) = 0.225 W/kg 0 dB = 0.225 W/kg = -6.48 dBW/kg Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 2 / 32 Test Plot 2#: GSM 850 Mid Body Bottom DUT: Mobile Data Terminal; Type: TC60 (Am); Serial: 3ABP-1 Communication System: Generic GPRS-4 slots (0); Frequency: 836.6 MHz; Duty Cycle: 1:2 Medium parameters used: f = 836.6 MHz; σ = 0.919 S/m; ε r = 41.886; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7441; ConvF(8.4, 8.36, 8.26) @836.6 MHz; Calibrated: 2025/09/11  Sensor-Surface: 1.4mm (Mechanical Surface Detection);  Electronics: DAE4 Sn1562; Calibrated: 2024/12/31  Phantom: Twin SAM; Type: QD000P40CD; Serial: 1744  Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.584 W/kg Zoom Scan (5x5x7) /Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 18.59 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.628 W/kg SAR(1 g) = 0.409 W/kg; SAR(10 g) = 0.266 W/kg Smallest distance from peaks to all points 3 dB below = 11.2 mm Ratio of SAR at M2 to SAR at M1 = 65.2% Maximum value of SAR (measured) = 0.481 W/kg 0 dB = 0.481 W/kg = -3.18 dBW/kg Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 3 / 32 Test Plot 3#: GSM 1900 Mid Head Left Cheek DUT: Mobile Data Terminal; Type: TC60 (Am); Serial: 3ABP-1 Communication System: Generic GPRS-4 slots (0); Frequency: 1880 MHz; Duty Cycle: 1:2 Medium parameters used: f = 1880 MHz; σ = 1.399 S/m; ε r = 40.712; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7441; ConvF(6.94, 6.91, 6.83) @1880 MHz; Calibrated: 2025/09/11  Sensor-Surface: 1.4mm (Mechanical Surface Detection);  Electronics: DAE4 Sn1562; Calibrated: 2024/12/31  Phantom: Twin SAM; Type: QD000P40CD; Serial: 1744  Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.178 W/kg Zoom Scan (5x5x7) /Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 0.3386 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.137 W/kg SAR(1 g) = 0.127 W/kg; SAR(10 g) = 0.099 W/kg Smallest distance from peaks to all points 3 dB below = 14.9 mm Ratio of SAR at M2 to SAR at M1 = 82.8% Maximum value of SAR (measured) = 0.132 W/kg 0 dB = 0.132 W/kg = -8.79 dBW/kg Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 4 / 32 Test Plot 4#: GSM 1900 Mid Body Bottom DUT: Mobile Data Terminal; Type: TC60 (Am); Serial: 3ABP-1 Communication System: Generic GPRS-4 slots (0); Frequency: 1880 MHz; Duty Cycle: 1:2 Medium parameters used: f = 1880 MHz; σ = 1.399 S/m; ε r = 40.712; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7441; ConvF(6.94, 6.91, 6.83) @1880 MHz; Calibrated: 2025/09/11  Sensor-Surface: 1.4mm (Mechanical Surface Detection);  Electronics: DAE4 Sn1562; Calibrated: 2024/12/31  Phantom: Twin SAM; Type: QD000P40CD; Serial: 1744  Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.846 W/kg Zoom Scan (5x5x7) /Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 21.63 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.876 W/kg SAR(1 g) = 0.756 W/kg; SAR(10 g) = 0.504 W/kg Smallest distance from peaks to all points 3 dB below = 11.2 mm Ratio of SAR at M2 to SAR at M1 = 83.7% Maximum value of SAR (measured) = 0.840 W/kg 0 dB = 0.840 W/kg = -0.76 dBW/kg Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 5 / 32 Test Plot 5#: WCDMA Band 2 Mid Head Left Cheek DUT: Mobile Data Terminal; Type: TC60 (Am); Serial: 3ABP-1 Communication System: WCDMA (0); Frequency: 1880 MHz; Duty Cycle: 1:1 Medium parameters used: f = 1880 MHz; σ = 1.399 S/m; ε r = 40.712; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 - SN7441; ConvF(6.94, 6.91, 6.83) @1880 MHz; Calibrated: 2025/09/11  Sensor-Surface: 1.4mm (Mechanical Surface Detection);  Electronics: DAE4 Sn1562; Calibrated: 2024/12/31  Phantom: Twin SAM; Type: QD000P40CD; Serial: 1744  Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7501) Area Scan (8x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.133 W/kg Zoom Scan (5x5x7) /Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.091 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.111 W/kg SAR(1 g) = 0.104 W/kg; SAR(10 g) = 0.076 W/kg Smallest distance from peaks to all points 3 dB below = 13.8 mm Ratio of SAR at M2 to SAR at M1 = 83.6% Maximum value of SAR (measured) = 0.108 W/kg 0 dB = 0.108 W/kg = -9.67 dBW/kg S…

Text truncated - open the document above for the full version.

RF Exposure Info

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA, or any agency of the Federal Government. The information marked ―#‖ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included but no need marked. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 755-26503290 Web: www.atc-lab.com Rev:A/4.0(2024/11/01) Page 1 of 97 TR-4-E-R050 TEST REPORT Applicant Name: GUANGZHOU YOKO ELECTRON CO.,LTD Address: 1 Room301,7th Huanbaosan Rd., Xintang Town, Zengcheng District, Guangzhou City 511340 Report Number: 2504X28433E-SA FCC ID: 2BSR3TC6 Test Standard (s) FCC 47 CFR part 2.1093 Sample Description Product Type: Mobile Data Terminal Model No.: TC60 (Am) Multiple Model(s) No.: N/A Trade Mark: N/A Serial Number: 3ABP-1 Date Received: 2025-09-18 Date of Test: 2025-09-22~2025-10-23 Issue Date: 2025-11-06 Test Result: The EUT complied with the standards above. Prepared and Checked By: Approved By: Jack Yang Lance Li SAR Engineer SAR Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Rev:A/4.0(2024/11/01) Page 2 of 97 TR-4-E-R050 Mode Max. Reported SAR Level(s) (W/kg) Limit (W/kg) GSM 850 1g Head SAR 0.20 1.6 1g Body SAR 0.44 GSM 1900 1g Head SAR 0.13 1g Body SAR 0.79 WCDMA Band 2 1g Head SAR 0.11 1g Body SAR 1.09 WCDMA Band 4 1g Head SAR 0.39 1g Body SAR 1.19 WCDMA Band 5 1g Head SAR 0.08 1g Body SAR 0.23 LTE Band 2 1g Head SAR 0.12 1g Body SAR 0.74 LTE Band 5 1g Head SAR 0.08 1g Body SAR 0.14 LTE Band 7 1g Head SAR 0.08 1g Body SAR 0.47 LTE Band 12 1g Head SAR 0.04 1g Body SAR 0.11 LTE Band 13 1g Head SAR 0.07 1g Body SAR 0.21 LTE Band 41&38 1g Head SAR 0.13 1g Body SAR 0.27 LTE Band 66&4 1g Head SAR 0.53 1g Body SAR 1.17 LTE Band 71 1g Head SAR 0.01 1g Body SAR 0.15 WIFI 2.4G 1g Head SAR 0.22 1g Body SAR 0.06 WIFI 5.2G 1g Head SAR 0.24 1g Body SAR 0.12 WIFI 5.8G 1g Head SAR 0.30 1g Body SAR 0.23 Simultaneous 1g Head SAR 0.83 1g Body SAR 1.42 1g Body SAR 1.25(Hotspot) Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Rev:A/4.0(2024/11/01) Page 3 of 97 TR-4-E-R050 Applicable Standards FCC 47 CFR part 2.1093 Radiation exposure evaluation: portable devices RF Exposure Procedures: TCB WorkshopApril2019 IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques KDB procedures KDB 447498 D01 General RF Exposure Guidance v06 KDB 648474 D04 Handset SAR v01r03 KDB865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB865664 D02 RF Exposure Reporting v01r02 KDB 941225 D05 SAR for LTE Devices v02r05 KDB 941225 D05A LTE Rel.10 KDB Inquiry Sheet v01r02 KDB941225 D06 Hotspot Mode v02r01 KDB 248227 D01 802.11 Wi-Fi SAR v02r02 Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Unless otherwise stated there are no any additions to, deviations, or exclusions from the method. Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Rev:A/4.0(2024/11/01) Page 4 of 97 TR-4-E-R050 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ................................................................................................................ 5 EUT DESCRIPTION .......................................................................................................................................... 6 TECHNICAL SPECIFICATION........................................................................................................................................ 6 REFERENCE, STANDARDS, AND GUILDELINES ................................................................................... 7 SAR LIMITS ................................................................................................................................................................ 7 FACILITIES ........................................................................................................................................................ 8 DESCRIPTION OF TEST SYSTEM ............................................................................................................... 9 Recommended Tissue Dielectric Parameters for Head liquid .................................................................... 15 EQUIPMENT LIST AND CALIBRATION .................................................................................................... 16 SAR MEASUREMENT SYSTEM VERIFICATION..................................................................................... 17 LIQUID VERIFICATION ............................................................................................................................................... 17 SYSTEM ACCURACY VERIFICATION ......................................................................................................................... 20 EUT TEST STRATEGY AND METHODOLOGY ....................................................................................... 29 TEST POSITIONS FOR DEVICE OPERATING NEXT TO A PERSON…

Text truncated - open the document above for the full version.

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 1 of 11 APPENDIX D RETURN LOSS&IMPEDANCE MEASUREMENT D750V3 - SN:1194 Extended Dipole Calibrations Per FCC KDB 865664 D01, calibration intervals of up to 3 years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements. 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20 dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 3-year calibration period from calibration date. Calibrated Equipment: Verification Date Equipment Model S/N Calibration Date Calibration Due Date 2024/02/17 Simulated Tissue Liquid Head HBBL600-10000V6 220406-1 Each Time SAM Twin Phantom SAM-Twin V5.0 1744 NCR NCR Network Analyzer E5071B MY42403851 2024/01/12 2025/01/11 Network Analyzer Calibration Kit 85033E MY53402696 NCR NCR 2025/02/16 Simulated Tissue Liquid Head HBBL600-10000V6 2200808-2 Each Time SAM Twin Phantom SAM-Twin V5.0 1744 NCR NCR Network Analyzer E5071B MY42403851 2024/10/08 2025/10/07 Network Analyzer Calibration Kit 85033E MY53402696 NCR NCR Test Data: D750V3 - SN:1194 750MHz Head Date of Measurement Return Loss (dB) Delta (%) Real Impedence(Ω) Delta (Ω) Imaginary Impedence(Ω) Delta (Ω) 2023/2/17 -28.9 / 50.8 / -3.54 / 2024/2/17 -29.1 0.69 47.7 3.1 -2.59 0.95 2025/2/16 -29.2 1.04 47.0 3.8 -1.48 2.06 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 2 of 11 Calibrated By: Lance Li Calibrated By: Lance Li Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 3 of 11 D1800V2 - SN: 2d018 Extended Dipole Calibrations Per FCC KDB 865664 D01, calibration intervals of up to 3 years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements. 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20 dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 3-year calibration period from calibration date. Calibrated Equipment: Verification Date Equipment Model S/N Calibration Date Calibration Due Date 2024/09/25 Simulated Tissue Liquid Head HBBL600-10000V6 220406-1 Each Time SAM Twin Phantom SAM-Twin V5.0 1744 NCR NCR Network Analyzer E5071B MY42403851 2024/01/12 2025/01/11 Network Analyzer Calibration Kit 85033E MY53402696 NCR NCR 2025/09/24 Simulated Tissue Liquid Head HBBL600-10000V6 220406-1 Each Time SAM Twin Phantom SAM-Twin V5.0 1744 NCR NCR Network Analyzer E5071B MY42403851 2024/10/08 2025/10/07 Network Analyzer Calibration Kit 85033E MY53402696 NCR NCR Test Data: D1800V2 - SN: 2d018 1800MHz Head Date of Measurement Return Loss (dB) Delta (%) Real Impedence(Ω) Delta (Ω) Imaginary Impedence(Ω) Delta (Ω) 2023/9/26 -28.9 / 47.2 / -2.01 / 2024/9/25 -26.3 9.0 47.1 0.1 -3.69 1.69 2025/09/24 -26.7 7.6 47.3 0.1 -3.57 1.56 Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 4 of 11 Calibrated By: Lance Li Calibrated By: Lance Li Shenzhen Accurate Technology Co., Ltd. Report No.: 2504X28433E-SA Page 5 of 11 D2450V2 - SN:751 Extended Dipole Calibrations Per FCC KDB 865664 D01, calibration intervals of up to 3 years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements. 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20 dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 3-year calibration period from calibration date. Calibrated Equipment: Verification Date Equipment Model S/N Calibration Date Calibration Due Date 2024/09/25 Simulated Tissue Liquid Head HBBL600-10000V6 220406-1 Each Time SAM Twin Phantom SAM-Twin V5.0 1744 NCR NCR Network Analyzer E5071B MY42403851 2024/01/12 2025/01/11 Network Analyzer Calibration Kit 85033E MY53402696 NCR NCR 2025/09/24 Simulated Tissue Liquid Head HBBL600-10000V6 220406-1 Each Time SAM Twin Phant…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yongjun Zhang(General Manager)
[email protected]Fax: +86-13060899736

Test Firm

Shenzhen Accurate Technology Co., Ltd.Hazel Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz38.50 mW
215E5.75 GHz - 5.83 GHz46.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.30 W/kg, 0.23 W/kg, and 1.42 W/kg, respectively. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes.